Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 140(13): 1061-1069, 2019 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-31466479

RESUMEN

BACKGROUND: Atrial arrhythmias are common in patients with implantable cardioverter-defibrillator (ICD). External shocks and internal cardioversion through commanded ICD shock for electrical cardioversion are used for rhythm-control. However, there is a paucity of data on efficacy of external versus internal cardioversion and on the risk of lead and device malfunction. We hypothesized that external cardioversion is noninferior to internal cardioversion for safety, and superior for successful restoration of sinus rhythm. METHODS: Consecutive patients with ICD undergoing elective cardioversion for atrial arrhythmias at 13 centers were randomized in 1:1 fashion to either internal or external cardioversion. The primary safety end point was a composite of surrogate events of lead or device malfunction. Conversion of atrial arrhythmia to sinus rhythm was the primary efficacy end point. Myocardial damage was studied by measuring troponin release in both groups. RESULTS: N=230 patients were randomized. Shock efficacy was 93% in the external cardioversion group and 65% in the internal cardioversion group (P<0.001). Clinically relevant adverse events caused by external or internal cardioversion were not observed. Three cases of pre-existing silent lead malfunction were unmasked by internal shock, resulting in lead failure. Troponin release did not differ between groups. CONCLUSIONS: This is the first randomized trial on external vs internal cardioversion in patients with ICDs. External cardioversion was superior for the restoration of sinus rhythm. The unmasking of silent lead malfunction in the internal cardioversion group suggests that an internal shock attempt may be reasonable in selected ICD patients presenting for electrical cardioversion. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03247738.


Asunto(s)
Arritmias Cardíacas/terapia , Fibrilación Atrial/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Anciano , Anciano de 80 o más Años , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Riesgo
2.
Artif Organs ; 43(7): 656-665, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30589446

RESUMEN

Endoluminal left atrial appendage occlusion is an emerging therapy to treat patients suffering from atrial fibrillation with contraindications against oral anticoagulation. Different occlusion devices have been introduced into the clinical setting while comparative studies between the devices are sparse. This in vitro study compares several endoluminal left atrial appendage occlusion systems regarding 2 mechanical properties: radial (RF) and tug force (TF). Seven different occluder systems of various sizes (24 in total) underwent testing throughout their recommended sizing range. RF was measured in a commercial RF tester. TF was assessed according to a recently published bench test. RF increased with compression of the devices: The LAmbre 2228 device exerted the highest RF (8.6 N) at maximum compression of 16 mm. The lowest RF of 0.1 N was exhibited by the 27 mm Occlutech occluder at minimal compression. The highest TFs were exerted by the WaveCrest devices at maximum compression with 4.6 and 3.6 N for the 22 mm and the 27 mm device, respectively. The lowest TFs were measured for the first-generation Occlutech devices, particularly for the 24 mm device with 1.1 N at maximum compression and 0.4 N at minimum compression. A strong positive correlation was found between the number of hooks per millimeter circumference of an occluder and its tug force (r = 0.87, P < 0.01). The analysis revealed device stability to be more dependent on anchoring structures than on RF. The wide range of mechanical properties makes comparison of current LAA occluders difficult and emphasizes the need for standardized preclinical testing to prompt clinical compatibility.


Asunto(s)
Apéndice Atrial/cirugía , Dispositivo Oclusor Septal , Fibrilación Atrial/cirugía , Humanos , Fenómenos Mecánicos , Diseño de Prótesis , Implantación de Prótesis
3.
Pacing Clin Electrophysiol ; 41(1): 22-27, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29211301

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) has become a widely accepted therapy in patients suffering from symptomatic atrial fibrillation (AF). HYPOTHESIS: AF-free survival differs in patients with left common pulmonary vein (LCPV) after PVI with second-generation cryoballoon. METHODS: We included patients scheduled for first PVI for paroxysmal or persistent AF. Symptomatic and/or documented arrhythmia episodes (>30 seconds) were defined as AF recurrence, excluding a 3-month blanking period. RESULTS: We observed a LCPV in 37 of 270 consecutive patients (13.7%). Analyses were performed in a 1:1 propensity score matched cohort of 68 patients. During a median follow-up of 77.0 weeks, 37 patients (54.4%) had recurrent AF. The prevalence of LCPV was numerically higher in patients with AF recurrence (62.2% vs 35.5%, P  =  0.051) and Kaplan-Meier analysis showed lower AF-free survival in patients with existence of a LCPV (P  =  0.028). At 1-year follow-up, 70.6% of patients without versus 55.1% of patients with LCPV were free of AF. Multivariate Cox regression analysis revealed presence of a LCPV (hazard ratio [HR]: 2.996), chronic heart failure (HR: 3.423), and mitral regurgitation > I° (HR: 2.571) as predictors of AF recurrence. CONCLUSION: Patients with LCPV had significantly reduced AF-free survival after ablation with the second-generation cryoballoon, despite similar acutely successful PVIs.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico por imagen , Angiografía Coronaria , Ecocardiografía , Femenino , Fluoroscopía , Alemania , Humanos , Masculino , Puntaje de Propensión , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
4.
Biochem Biophys Res Commun ; 493(1): 604-610, 2017 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-28867191

RESUMEN

BACKGROUND: During aging a mosaic of normal cells and cells with mitochondrial deficiency develops in various tissues including the heart. Whether this contributes to higher susceptibility for arrhythmia following myocardial infarction (MI) is unknown. METHODS AND RESULTS: Myocardial cryoinfarction was performed in 12-month-old transgenic mice with accelerated accumulation of deletions in mitochondrial DNA. Occurrence and pathogenesis of arrhythmia was investigated after two weeks. Holter-ECG recordings revealed higher rates of premature ventricular complexes (incidence > 10/24 h: 100% vs. 20%; p = 0.048) and more severe spontaneous arrhythmia during stress test in mutant mice with MI as compared to control mice with MI. Mice with mitochondrial dysfunction exhibited longer spontaneous AV-blocks (467 ± 26 ms vs. 377 ± 24 ms; p = 0.013), an increased probability for induction of ventricular tachycardia during in vivo electrophysiological investigation (22% vs. 9%; p = 0.044), and a reduced conduction velocity in the infarct borderzone (38.5 ± 0.5 cm/s vs. 55.3 ± 0.9 cm/s; p = 0.001). Furthermore, mutant mice exhibited a significant reduction of the phospho-Cx43/Cx43 ratio in right (0.59 ± 0.04 vs. 0.85 ± 0.01; p = 0.027) and left ventricular myocardium (0.72 ± 0.01 vs. 0.86 ± 0.02; p = 0.023). CONCLUSIONS: Aging-related cardiac mosaic respiratory chain dysfunction facilitates the occurrence of spontaneous and inducible cardiac arrhythmia after myocardial infarction and is associated with slowing of electrical impulse propagation in the infarct borderzone.


Asunto(s)
Envejecimiento , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Mitocondrias Cardíacas , Enfermedades Mitocondriales/fisiopatología , Infarto del Miocardio/fisiopatología , Animales , Femenino , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Enfermedades Mitocondriales/complicaciones , Infarto del Miocardio/complicaciones
5.
Biochem Biophys Res Commun ; 490(3): 643-649, 2017 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-28634079

RESUMEN

BACKGROUND: Relaxin-2 (RLX) is a peptide hormone that exerts beneficial anti-fibrotic and anti-inflammatory effects in diverse models of cardiovascular disease. The goal of this study was to determine the effects of RLX treatment on the susceptibility to atrial fibrillation (AF) after myocardial infarction (MI). METHODS: Mice with cryoinfarction of the left anterior ventricular wall were treated for two weeks with either RLX (75 µg/kg/d) or vehicle (sodium acetate) delivered via subcutaneously implanted osmotic minipumps. RESULTS: RLX treatment significantly attenuated the increase in AF-inducibility following cryoinfarction and reduced the mean duration of AF episodes. Furthermore, epicardial mapping of both atria revealed an increase in conduction velocity. In addition to an attenuation of atrial hypertrophy, chronic application of RLX reduced atrial fibrosis, which was linked to a significant reduction in atrial mRNA expression of connective tissue growth factor. Transcript levels of the pro-inflammatory cytokines interleukin-6 and interleukin-1ß were reduced in RLX treated mice, but macrophage infiltration into atrial myocardium was similar in the vehicle and RLX treated groups. CONCLUSION: Treatment with RLX in mice after MI reduces susceptibility to AF due to anti-inflammatory and anti-fibrotic properties. Because to these favorable actions, RLX may become a new therapeutic option in the treatment of AF, even when complicating MI.


Asunto(s)
Antiinflamatorios/uso terapéutico , Fibrilación Atrial/etiología , Fibrilación Atrial/prevención & control , Atrios Cardíacos/efectos de los fármacos , Infarto del Miocardio/complicaciones , Relaxina/uso terapéutico , Animales , Antiinflamatorios/administración & dosificación , Fibrilación Atrial/fisiopatología , Cardiomegalia/etiología , Cardiomegalia/fisiopatología , Cardiomegalia/prevención & control , Femenino , Atrios Cardíacos/fisiopatología , Masculino , Ratones , Relaxina/administración & dosificación
6.
J Electrocardiol ; 50(5): 603-609, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28499628

RESUMEN

BACKGROUND: The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool to protect patients with increased risk of sudden cardiac death (SCD). We sought to characterize WCD patients and to analyze predictors of ventricular arrhythmia (VA) occurrence and WCD shock delivery. METHODS AND RESULTS: One hundred fourteen patients with WCD use were included in the study. Indications were mainly ischemic cardiomyopathy (ICM; 31.6%), non-ICM (45.6%) and explantation of implantable cardioverter defibrillator due to device infection (11.4%). We observed sustained VA in 9.6% of the study population and 6.1% received an appropriate shock. VA occurred in 16.7% of ICM, 3.8% of non-ICM and 15.4% of patients with device infection. CONCLUSIONS: Our data demonstrate a very high rate of sustained VA in patients at risk for SCD during WCD use. ICM patients, including those with recent MI, bore the highest risk.


Asunto(s)
Cardiomiopatías/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/instrumentación , Dispositivos Electrónicos Vestibles , Adulto , Anciano , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad
8.
Pacing Clin Electrophysiol ; 39(10): 1099-1107, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27484618

RESUMEN

BACKGROUND: Visually guided laserballoon (LB) ablation has recently been introduced for pulmonary vein (PV) isolation (PVI). We analyzed efficacy and safety results of the newly introduced LB ablation technique in patients with persistent and longstanding persistent atrial fibrillation (AF), and compared this with an established standard method using the cryoballoon (CB). METHODS: A total of 35 patients with symptomatic persistent AF underwent LB ablation and were followed-up for 1 year. Results were compared to 35 patients who underwent CB ablation at the same institution and case matched for age, sex, CHA2 DS2 -VASc score, and left atrial volume. RESULTS: Complete isolation of all PVs was achieved in 68.6% in the LB and 97.1% in the CB group (P < 0.01). No significant differences were found for AF-free survival after 12 months in the complete cohort of all patients (LB: 53.3% vs CB: 70.4%; P = n.s.) and after excluding patients without complete PVI (LB: 57.8% vs CB: 72.5%; P = n.s.). LB ablation resulted in longer procedure (158.5 ± 37.9 minutes vs 110.9 ± 26.5 minutes; P < 0.01) and fluoroscopy durations (28.4 ± 11.1 minutes vs 23.5 ± 9.4 minutes; P = 0.04.), and a trend toward more major complications (14.3% vs 2.9%; P = n.s.). Procedure durations and complications declined over time and were level with CB-treated patients when reaching the last quartile of the LB patients. CONCLUSION: PVI in patients with persistent AF using the LB or the CB resulted in comparable success rates. Initial prolongations in procedure and safety parameters as a result of a learning curve effect for the LB have to be considered before starting to use this technique.


Asunto(s)
Angioplastia de Balón Asistida por Láser , Fibrilación Atrial/cirugía , Criocirugía/métodos , Venas Pulmonares/cirugía , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
9.
J Cardiovasc Electrophysiol ; 25(8): 859-865, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24724724

RESUMEN

INTRODUCTION: Right phrenic nerve palsy (PNP) is a typical complication of cryoballoon ablation of the right-sided pulmonary veins (PVs). Phrenic nerve function can be monitored by palpating the abdomen during phrenic nerve pacing from the superior vena cava (SVC pacing) or by fluoroscopy of spontaneous breathing. We sought to compare the sensitivity of these 2 techniques during cryoballoon ablation for detection of PNP. METHODS AND RESULTS: A total of 133 patients undergoing cryoballoon ablation were monitored with both SVC pacing and fluoroscopy of spontaneous breathing during ablation of the right superior PV. PNP occurred in 27/133 patients (20.0%). Most patients (89%) had spontaneous recovery of phrenic nerve function at the end of the procedure or on the following day. Three patients were discharged with persistent PNP. All PNP were detected first by fluoroscopic observation of diaphragm movement during spontaneous breathing, while diaphragm could still be stimulated by SVC pacing. In patients with no recovery until discharge, PNP occurred at a significantly earlier time (86 ± 34 seconds vs. 296 ± 159 seconds, P < 0.001). No recovery occurred in 2/4 patients who were ablated with a 23 mm cryoballoon as opposed to 1/23 patients with a 28 mm cryoballoon (P = 0.049). CONCLUSION: Fluoroscopic assessment of diaphragm movement during spontaneous breathing is more sensitive for detection PNP as compared to SVC pacing. PNP as assessed by fluoroscopy is frequent (20.0%) and carries a high rate of recovery (89%) until discharge. Early onset of PNP and use of 23 mm cryoballoon are associated with PNP persisting beyond hospital discharge.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Diafragma/inervación , Monitoreo Intraoperatorio/métodos , Parálisis/diagnóstico , Traumatismos de los Nervios Periféricos/diagnóstico , Nervio Frénico/lesiones , Venas Pulmonares/cirugía , Respiración , Adulto , Anciano , Puntos Anatómicos de Referencia , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Eléctrica , Femenino , Fluoroscopía , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Palpación , Parálisis/diagnóstico por imagen , Parálisis/etiología , Parálisis/fisiopatología , Alta del Paciente , Traumatismos de los Nervios Periféricos/diagnóstico por imagen , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/fisiopatología , Nervio Frénico/fisiopatología , Nervio Frénico/cirugía , Valor Predictivo de las Pruebas , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Recuperación de la Función , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
Circ Res ; 111(12): 1528-38, 2012 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-22982984

RESUMEN

RATIONALE: The gap junctional protein connexin (Cx) 45 is strongly expressed in the early embryonic myocardium. In the adult hearts of mice and humans, the expression mainly is restricted to the cardiac conduction system. Cx45 plays an essential role for development and function of the embryonic heart because general and cardiomyocyte-directed deficiencies of Cx45 in mice lead to embryonic lethality attributable to morphological and functional cardiovascular defects. The function of Cx45 in the adult mouse has not yet been cleared. OBJECTIVE: To clarify the function of Cx45 in the adult mouse heart. METHODS AND RESULTS: To circumvent the embryonic lethality resulting from Cx45 deficiency, mice were generated in which deletion of Cx45 specifically was induced in cardiomyocytes of adult mice. These Cx45-deficient mice were viable but showed a decrease in atrioventricular nodal conductivity. In addition, the Cx30.2 protein that is coexpressed with Cx45 in the cardiac conduction system was posttranscriptionally reduced by 70% in mutant hearts. Furthermore, deletion of both Cx45 and Cx30.2 resulted in viable mice that, however, showed stronger impairment of atrioventricular nodal conduction than the single Cx45-deficient mice. CONCLUSIONS: Cx45 is required for optimal impulse propagation in the atrioventricular node and stabilizes the level of the coexpressed Cx30.2 protein in the adult mouse heart. In contrast to the embryo, Cx45 is not essential for the viability of adult mice.


Asunto(s)
Nodo Atrioventricular/embriología , Nodo Atrioventricular/metabolismo , Conexinas/fisiología , Corazón/embriología , Corazón/fisiología , Animales , Conexinas/deficiencia , Conexinas/genética , Sistema de Conducción Cardíaco/embriología , Sistema de Conducción Cardíaco/metabolismo , Ratones , Ratones Noqueados
11.
Cell Mol Life Sci ; 70(3): 527-43, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22945801

RESUMEN

Cyclase-associated proteins are highly conserved proteins that have a role in the regulation of actin dynamics. Higher eukaryotes have two isoforms, CAP1 and CAP2. To study the in vivo function of CAP2, we generated mice in which the CAP2 gene was inactivated by a gene-trap approach. Mutant mice showed a decrease in body weight and had a decreased survival rate. Further, they developed a severe cardiac defect marked by dilated cardiomyopathy (DCM) associated with drastic reduction in basal heart rate and prolongations in atrial and ventricular conduction times. Moreover, CAP2-deficient myofibrils exhibited reduced cooperativity of calcium-regulated force development. At the microscopic level, we observed disarrayed sarcomeres with development of fibrosis. We analyzed CAP2's role in actin assembly and found that it sequesters G-actin and efficiently fragments filaments. This activity resides completely in its WASP homology domain. Thus CAP2 is an essential component of the myocardial sarcomere and is essential for physiological functioning of the cardiac system, and a deficiency leads to DCM and various cardiac defects.


Asunto(s)
Cardiomiopatía Dilatada/metabolismo , Proteínas Portadoras/metabolismo , Actinas/metabolismo , Secuencia de Aminoácidos , Animales , Calcio/metabolismo , Cardiomiopatía Dilatada/patología , Proteínas Portadoras/química , Proteínas Portadoras/genética , Femenino , Fibrosis , Corazón/anatomía & histología , Corazón/fisiopatología , Frecuencia Cardíaca/fisiología , Heterocigoto , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Datos de Secuencia Molecular , Fenotipo , Estructura Terciaria de Proteína , Sarcómeros/metabolismo
12.
Clin Res Cardiol ; 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38358420

RESUMEN

INTRODUCTION: Cryoballoon (CB) ablation has become a popular method for pulmonary vein isolation (PVI) in atrial fibrillation (AF) treatment. This study aimed to compare the intraprocedural ablation characteristics of two cryoballoons, Arctic Front Advance Pro™ (AFA-Pro, Medtronic) and POLARx™ (Boston Scientific). METHODS AND RESULTS: In this retrospective single-center study, 230 symptomatic paroxysmal or persistent AF patients underwent CB ablation with either AFA-Pro or POLARx. Propensity-score matching resulted in two cohorts of 114 patients each. Baseline and procedural characteristics were comparable between both CBs. POLARx achieved lower minimal temperatures (e.g., left superior pulmonary vein, LSPV: AFA-Pro - 49.0 °C vs. POLARx - 59.5 °C) and lower temperatures at time-to-isolation (TTI). Additionally, POLARx reached lower temperatures faster, as evidenced by lower temperatures after 40 and 60 s, and a larger mean temperature change between 20 and 40 s. POLARx also had a greater area under the curve below 0 °C and a longer thawing phase. Both CBs achieved comparable high rates of final PV-isolation. TTI, minimal esophagus temperature, and first-pass isolation rates were similar between groups. Periprocedural complications, including phrenic nerve injuries, were comparable. Troponin levels in the left atrium were elevated with both systems. Values and change in troponin were numerically higher in the POLARx group (delta troponin: AFA-Pro 36.3 (26.4, 125.4) ng/L vs. POLARx 104.9 (49.5, 122.2) ng/L), p = 0.077). CONCLUSION: AFA-Pro and POLARx are both highly effective and safe CB systems for PVI. POLARx exhibited significant faster and lower freezing characteristics, and numerically higher troponin levels might indicate greater myocardial injury. However, these differences did not translate into improved performance, procedural efficiency, or safety.

13.
Nature ; 450(7171): 819-24, 2007 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-18064002

RESUMEN

Ventricular tachyarrhythmias are the main cause of sudden death in patients after myocardial infarction. Here we show that transplantation of embryonic cardiomyocytes (eCMs) in myocardial infarcts protects against the induction of ventricular tachycardia (VT) in mice. Engraftment of eCMs, but not skeletal myoblasts (SMs), bone marrow cells or cardiac myofibroblasts, markedly decreased the incidence of VT induced by in vivo pacing. eCM engraftment results in improved electrical coupling between the surrounding myocardium and the infarct region, and Ca2+ signals from engrafted eCMs expressing a genetically encoded Ca2+ indicator could be entrained during sinoatrial cardiac activation in vivo. eCM grafts also increased conduction velocity and decreased the incidence of conduction block within the infarct. VT protection is critically dependent on expression of the gap-junction protein connexin 43 (Cx43; also known as Gja1): SMs genetically engineered to express Cx43 conferred a similar protection to that of eCMs against induced VT. Thus, engraftment of Cx43-expressing myocytes has the potential to reduce life-threatening post-infarct arrhythmias through the augmentation of intercellular coupling, suggesting autologous strategies for cardiac cell-based therapy.


Asunto(s)
Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/prevención & control , Conexina 43/metabolismo , Infarto del Miocardio/complicaciones , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/trasplante , Animales , Arritmias Cardíacas/patología , Arritmias Cardíacas/fisiopatología , Conexina 43/genética , Embrión de Mamíferos/citología , Corazón/fisiología , Corazón/fisiopatología , Humanos , Ratones , Ratones Transgénicos , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Miocardio/citología , Miocardio/patología , Perfusión
15.
Int J Cardiol Heart Vasc ; 44: 101168, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36620202

RESUMEN

Aims: Na+/Ca2+ exchanger (NCX) upregulation in cardiac diseases like heart failure promotes as an independent proarrhythmic factor early and delayed afterdepolarizations (EADs/DADs) on the single cell level. Consequently, NCX inhibition protects against EADs and DADs in isolated cardiomyocytes. We here investigate, whether these promising cellular in vitro findings likewise apply to an in vivo setup. Methods/Results: Programmed ventricular stimulation (PVS) and isoproterenol were applied to a murine heterozygous NCX-knockout model (KO) to investigate ventricular arrhythmia initiation and perpetuation compared to wild-type (WT). KO displayed a reduced susceptibility towards isoproterenol-induced premature ventricular complexes. During PVS, initiation of single or double ectopic beats was similar between KO and WT. But strikingly, perpetuation of ventricular tachycardia (VT) was significantly increased in KO (animals with VT - KO: 82 %; WT: 47 %; p = 0.0122 / median number of VTs - KO: 4.5 (1.0, 6.25); WT: 0.0 (0.0, 4.0); p = 0.0039). The median VT duration was prolonged in KO (in s; KO: 0.38 (0.19, 0.96); WT: 0.0 (0.0, 0.60); p = 0.0239). The ventricular refractory period (VRP) was shortened in KO (in ms; KO: 15.1 ± 0.7; WT: 18.7 ± 0.7; p = 0.0013). Conclusions: Not the initiation, but the perpetuation of provoked whole-heart in vivo ventricular arrhythmia was increased in KO. As a potential mechanism, we found a significantly reduced VRP, which may promote perpetuation of reentrant ventricular arrhythmia. On a translational perspective, the antiarrhythmic concept of therapeutic NCX inhibition seems to be ambivalent by protecting from initiating afterdepolarizations but favoring arrhythmia perpetuation in vivo at least in a murine model.

16.
J Cardiovasc Electrophysiol ; 23(11): 1254-7, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22486804

RESUMEN

The risk of atrioesophageal fistula after cryoballoon pulmonary vein isolation is thought to be much lower than after radiofrequency ablation, seeing that no data exist on this complication so far. We report for the first time on the occurrence of an atrioesophageal fistula 4 weeks after cryoballoon ablation at the site of the left inferior pulmonary vein. We suggest that even when using cryothermal ablation technique, an imaging modality to assess the proximity of esophagus and left atrium should be routinely performed to avoid this fatal complication.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Criocirugía/efectos adversos , Criocirugía/instrumentación , Fístula Esofágica/etiología , Fístula/etiología , Cardiopatías/etiología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Embolia Aérea/etiología , Fístula Esofágica/diagnóstico por imagen , Fístula Esofágica/cirugía , Fístula/diagnóstico por imagen , Fístula/cirugía , Atrios Cardíacos/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Humanos , Masculino , Estado Vegetativo Persistente/etiología , Venas Pulmonares/diagnóstico por imagen , Reoperación , Accidente Cerebrovascular/etiología , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
J Cardiovasc Electrophysiol ; 23(3): 247-55, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21955059

RESUMEN

OBJECTIVE: Since predictors of recurrence of atrial fibrillation (AF) after ablation procedures are poorly defined, this prospective study was conducted to assess the value of left atrial (LA) deformation imaging with two-dimensional speckle-tracking (2D-ST) to predict AF recurrences after successful ablation procedures. METHODS AND RESULTS: One hundred and three consecutive patients (age 58.1 ± 16.6 years, 72.8% male) with AF (76 paroxysmal, 27 persistent) and 30 matched controls underwent transthoracic echocardiography and 2D-ST-LA-deformation analysis with assessment of LA-radial and LA-longitudinal strain (Sr, Sl), and velocities derived from the apical 4- and 2-chamber views (4CV, 2CV). AF recurrence was assessed during 6 months of follow-up. For determination of AF-related LA changes, AF patients were compared to controls and patients with AF recurrences after ablation procedures (n = 30, 29.1%) were compared with patients who maintained sinus rhythm (n = 73, 70.9%). Atrial deformation capabilities were significantly reduced (P < 0.0005) in patients with AF (4CVSl 17.8 ± 13.5%; 4CVSr 22.3 ± 14.9%; 4CV-velocities 2.53 ± 0.97 seconds) when compared with controls (4CVSl 31.3 ± 12.4%; 4CVSr 30.3 ± 9.1%; 4CV-velocities 3.48 ± 1.01 cm/s). Independent predictors for AF recurrence after ablation procedures were 2CV-LA-global-strain (Sr, P = 0.03; Sl, P = 0.003), 4CV-LA-gobal-strain (Sr, P = 0.03; Sl, P = 0.02), and regional LA-septal wall-Sl (P = 0.008). LA-global-strain parameters were superior to regional LA function analysis for the prediction of AF recurrences, with cutoff values (cov), hazard ratios (HR), positive and negative predictive values (PPV, NPV) were: 4CVSl cov, 10.79% (HR 27.8, P < 0.0005; PPV 78.8%, NPV 93.9%), 4CVSr cov, -16.65% (HR 24.8, P < 0.0005; PPV 69.4%, NPV 96.6%), 2CVSl cov, 12.31% (HR 22.7, P < 0.0005; PPV 75.8%, NPV 95.3%), and 2CVSr cov, -14.9% (HR 12.9, P < 0.0005; PPV 64.3%, NPV 93.2%). CONCLUSION: Compared with controls, AF itself seems to decrease LA deformation capabilities. The assessment of global LA strain with 2D-ST identifies patients with high risk for AF recurrence after ablation procedures. This imaging technique may help to improve therapeutic guiding for patients with AF.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Anciano , Función del Atrio Izquierdo , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Recurrencia , Reproducibilidad de los Resultados
18.
Crit Care ; 16(4): R152, 2012 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-22889197

RESUMEN

INTRODUCTION: Cardiogenic shock (CS) remains the leading cause of death in patients hospitalized for myocardial infarction (MI). Systemic inflammation with inappropriate vasodilatation is observed in many patients with CS and may contribute to an excess mortality rate. The purpose of this study was to determine the predictive role of serial measurements of Nt-proBNP, interleukin-6 (IL-6), and procalcitonin (PCT) for 30-day mortality in patients with CS due to MI. METHODS: The present study is a prospective single-center study including 87 patients with MI complicated by CS treated with acute revascularization and intraaortic balloon counterpulsation (IABP) support. Predictive values of plasma levels at admission (T0), after 24 hours (T1), and after 72 hours (T2) were examined according to 30-day mortality. RESULTS: Significant differences between survivors (n = 59) and nonsurvivors (n = 28) were seen for Nt-proBNP at T0, for IL-6 at T0 and T1, and for PCT at T1 and T2. According to ROC analyses, the highest accuracy predicting 30-day mortality was seen at T0 for IL-6, at T1 for PCT, and at T2 for PCT. In univariate analysis, significant values were found for Nt-proBNP at T1, and for IL-6 and PCT at all points in time. Within the multivariate analysis, age, creatinine, and IL-6 were significant determinants of 30-day mortality, in which IL-6 showed the highest level of significance. CONCLUSIONS: In patients with MI complicated by CS, IL-6 represented a reliable independent early prognostic marker of 30-day mortality. PCT revealed a significant value at later points in time, whereas Nt-proBNP seemed to be of lower relevance.


Asunto(s)
Calcitonina/sangre , Mortalidad Hospitalaria , Interleucina-6/sangre , Infarto del Miocardio/complicaciones , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Precursores de Proteínas/sangre , Choque Cardiogénico/sangre , Choque Cardiogénico/mortalidad , Lesión Renal Aguda/complicaciones , Anciano , Análisis de Varianza , Biomarcadores/sangre , Péptido Relacionado con Gen de Calcitonina , Creatinina/sangre , Femenino , Hemodinámica , Humanos , Unidades de Cuidados Intensivos , Contrapulsador Intraaórtico , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/cirugía , Revascularización Miocárdica , Estudios Prospectivos , Sensibilidad y Especificidad , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía
19.
Pacing Clin Electrophysiol ; 35(11): e334-6, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22845556

RESUMEN

Transcatheter ablation of the pulmonary veins (PVs) has been established as a therapeutic option for patients with symptomatic atrial fibrillation. Cryothermal energy is an alternative energy source that has been developed to overcome some of the disadvantages of radiofrequency ablation. The major complication of the cryoballoon technique seems to be right-sided phrenic nerve injury (PNI) following ablation of the right superior PV. This case report describes a left-sided PNI after cryoballoon ablation of the left superior PV.


Asunto(s)
Angioplastia de Balón/efectos adversos , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Sistema de Conducción Cardíaco/cirugía , Traumatismos de los Nervios Periféricos/etiología , Nervio Frénico/lesiones , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/complicaciones , Humanos , Masculino , Traumatismos de los Nervios Periféricos/diagnóstico , Resultado del Tratamiento
20.
Pacing Clin Electrophysiol ; 34(6): 684-9, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21303390

RESUMEN

BACKGROUND: Little is known about the prevalence of upper extremity vein obstruction or anomalies in patients before first implantation of implantable cardioverter defibrillator (ICD). It remains unclear in which patients contrast venography is warranted before implantation procedure. METHODS: Results of clinical data and contrast venography of 302 consecutive patients scheduled for first ICD implantation were analyzed. RESULTS: Prevalence of upper vein obstruction was 6.6% (20/302 patients) in a typical patient population undergoing first ICD implantation. Age, left ventricular ejection fraction, underlying heart disease, prior open-heart surgery, or cardiopulmonary resuscitation were not predictors of obstruction. Patients with previous cardiac pacemaker implantation had a higher rate of obstruction, though this was not statistically significant (20% vs 15.7%, P = 0.54). Persistent left vena cava was found in 0.7%. CONCLUSION: There is no clinical parameter sufficient enough to predict upper extremity venous obstruction. Contrast venography may be considered in patients with previous pacemaker placement but should not be a routine diagnostic tool in unselected patients prior to first ICD-implantation procedure.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Falla de Prótesis , Implantación de Prótesis/estadística & datos numéricos , Extremidad Superior/irrigación sanguínea , Insuficiencia Venosa/epidemiología , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Medición de Riesgo , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA