Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiothorac Vasc Anesth ; 38(2): 417-422, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38114369

RESUMEN

OBJECTIVES: The IKORUS system (Vygon, Écouen, France) allows continuous monitoring of the urethral perfusion index (uPI) using a photoplethysmographic sensor mounted near the base of the balloon of a dedicated urinary catheter. We aimed to test the hypothesis that the uPI decreases during off-pump coronary artery bypass (OPCAB) surgery and to investigate the relationship between the uPI and macrocirculatory variables. DESIGN: Prospective observational study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PARTICIPANTS: Twenty patients having OPCAB surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was changes in the uPI during OPCAB surgery. We additionally investigated associations between the uPI and cardiac output, mean arterial pressure, heart rate, and point-of-care variables. Twenty patients with 24,137 uPI measurements were included. Overall, there was a high interindividual variability in the uPI. Compared with the preparation phase (during which the median [interquartile range] uPI was 7.7 [5.6-12.0]), the uPI decreased by 14% (95% CI 13%-15%) during the bypass grafting phase, by 35% (95% CI 34%-36%) during the cardiac positioning phase, and by 7% (95% CI 6%-9%) during hemostasis. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. CONCLUSIONS: The uPI decreases during OPCAB surgery, specifically during the cardiac positioning phase. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. It, therefore, remains to be determined whether intraoperative uPI decreases are clinically important, reflect alterations in intra-abdominal tissue perfusion that are not reflected by systemic macrohemodynamics, and can help clinicians guide therapeutic interventions.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Humanos , Presión Arterial , Gasto Cardíaco/fisiología , Frecuencia Cardíaca/fisiología , Índice de Perfusión , Estudios Prospectivos
2.
BMC Med Educ ; 24(1): 226, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38438991

RESUMEN

BACKGROUND: During the crucial stage of the COVID-19 pandemic, face-to-face undergraduate medical education was disrupted and replaced with online teaching activities. Based on its emphasized impact on several outcomes, a deeper insight into the pandemic related effects on medical students´ motivation is aspirational. Therefore, this study aimed to assess the motivational changes that took place during the pandemic in medical students and explored, how motivation of medical students is influenced. METHODS: Using a mixed method inter-cohort study design, 4th year medical students´ motivation, assessed pre- and post-pandemic were compared. In subsequent qualitative analyses underlying variables that may have contributed to both- medical students´ motivation and pandemic related changes were identified. These variables were then systematically explored- both individually and in combination. In a final step, the results were embedded within the Self-Determination Theory. RESULTS: Students who were affected by the university lockdown reported significantly higher levels of less self-determined motivation and amotivation. The qualitative analysis identified determinants that influence medical students´ motivation. The common core of these determinants is lacking social interaction and support, with a great emphasis on the interaction with the lecturer and patients. CONCLUSION: This study emphasizes the crucial role of medical educators, patient contact, social interactions and personal support on students´ motivation. Students need to be strengthened in their beliefs about their abilities, the value of their task at hand and receive encouragement in their efforts. All this will result in an increased identification with the task and less detrimental outcomes.


Asunto(s)
COVID-19 , Estudiantes de Medicina , Humanos , COVID-19/epidemiología , Estudios de Cohortes , Control de Enfermedades Transmisibles , Pandemias , Universidades
3.
Anesth Analg ; 135(1): 71-78, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35452017

RESUMEN

BACKGROUND: Cardiac output (CO) is a key determinant of oxygen delivery, but choosing the optimal method to obtain CO in pediatric patients remains challenging. The pressure recording analytical method (PRAM), implemented in the MostCareUp system (Vygon), is an invasive uncalibrated pulse wave analysis (PWA) method to measure CO. The objective of this study is to compare CO measured by PRAM (PRAM-CO; test method) with CO simultaneously measured by transesophageal Doppler echocardiography (TEE-CO; reference method) in pediatric patients. METHODS: In this prospective observational method comparison study, PRAM-CO and TEE-CO were assessed in pediatric elective cardiac surgery patients at 2 time points: after anesthesia induction and after surgery. The study was performed in a German university medical center from March 2019 to March 2020. We included pediatric patients scheduled for elective cardiac surgery with arterial catheter and TEE monitoring. PRAM-CO and TEE-CO were compared using Bland-Altman analysis accounting for repeated measurements per subject, and the percentage error (PE). RESULTS: We included 52 PRAM-CO and TEE-CO measurement pairs of 30 patients in the final analysis. Mean ± SD TEE-CO was 2.15 ± 1.31 L/min (range 0.55-6.07 L/min), and mean PRAM-CO was 2.21 ± 1.38 L/min (range 0.55-5.90 L/min). The mean of the differences between TEE-CO and PRAM-CO was -0.06 ±0.38 L/min with 95% limits of agreement (LOA) of 0.69 (95% confidence interval [CI], 0.53-0.82 L/min) to -0.80 L/min (95% CI, -1.00 to -0.57 L/min). The resulting PE was 34% (95% CI, 27%-41%). CONCLUSIONS: With a PE of <45%, PRAM-CO shows clinically acceptable agreement with TEE-CO in hemodynamically stable pediatric patients before and after cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Transesofágica , Gasto Cardíaco , Niño , Ecocardiografía Doppler , Ecocardiografía Transesofágica/métodos , Humanos , Análisis de la Onda del Pulso , Reproducibilidad de los Resultados , Termodilución
4.
Anesth Analg ; 134(2): 322-329, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34854823

RESUMEN

BACKGROUND: Cardiac output is an important hemodynamic variable and determines oxygen delivery. In contrast to blood pressure, cardiac output is rarely measured even in high-risk surgical patients, suggesting that clinicians consider blood pressure to be a reasonable indicator of systemic blood flow. However, the relationship depends on constant vascular tone and volume, both of which routinely vary during anesthesia and surgery. We therefore tested the hypothesis that there is no clinically meaningful correlation between mean arterial pressure and cardiac index in major abdominal surgery patients. METHODS: In this prospective observational study, we assessed the relationship between mean arterial pressure and cardiac index in 100 patients having major abdominal surgery under general anesthesia. RESULTS: The pooled within-patient correlation coefficient calculated using meta-analysis methods was r = 0.34 (95% confidence interval, 0.28-0.40). Linear regression using a linear mixed effects model of cardiac index on mean arterial pressure revealed that cardiac index increases by 0.014 L·min-1·m-2 for each 1 mm Hg increase in mean arterial pressure. The 95% Wald confidence interval of this slope was 0.011 to 0.018 L·min-1·m-2·mm Hg-1 and thus within predefined equivalence margins of -0.03 and 0.03 L·min-1·m-2·mm Hg-1, thereby demonstrating lack of clinically meaningful association between mean arterial pressure and cardiac index. CONCLUSIONS: There is no clinically meaningful correlation between mean arterial pressure and cardiac index in patients having major abdominal surgery. Intraoperative blood pressure is thus a poor surrogate for cardiac index.


Asunto(s)
Abdomen/cirugía , Presión Arterial/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Gasto Cardíaco/fisiología , Monitoreo Intraoperatorio/métodos , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
Artículo en Inglés | MEDLINE | ID: mdl-36216331

RESUMEN

BACKGROUND: Systemic inflammation due to cardiogenic shock is associated with vasoplegia leading to organ hypoperfusion, right heart failure, and poor clinical outcome. Extracorporeal cytokine hemoadsorption emerged to attenuate excessive levels of inflammatory cytokines, potentially improving patient outcomes. Nevertheless, its prognostic impact during high-risk left ventricular assist device (LVAD) implantation remains unknown. METHODS: In total, 40 consecutive patients with advanced heart failure underwent continuous-flow LVAD implantation at our institution between 2018 and 2020. Out of 25 high-risk patients in cardiogenic shock (Interagency Registry for Mechanically Assisted Circulatory Support profile 1 and 2), 9 patients (CytoSorb group) underwent LVAD implantation with and 16 patients (control group) without simultaneous cytokine hemoadsorption during cardiopulmonary bypass. Besides preoperative patient characteristics, postoperative lactate clearance, vasopressor administration and mean arterial pressure, perioperative complication, and 30-day mortality rates were retrospectively analyzed. RESULTS: Apart from an increased rate of reoperations within the CytoSorb group, baseline characteristics including the severity of ventricular dysfunction and consecutive signs of end-organ failure were similar in both groups. Preoperative short-term mechanical circulatory support bridging was comparable (66.7 vs. 75%; p = 0.66) prior to LVAD implantation. Procedural characteristics including intraoperative volume management and postoperative vasopressor administration were similar in both groups. There was no difference regarding postoperative lactate clearance, although postoperative mean arterial pressure was significantly higher in the control group (71.3 vs. 57.4 mm Hg; p < 0.01). Furthermore, the 30-day mortality rate was significantly higher in the CytoSorb group (33.3 vs. 0.0%; p = 0.01). CONCLUSION: Extracorporeal cytokine hemoadsorption during high-risk LVAD implantation was not associated with a decrease of postoperative vasopressor support, improved hemodynamics, or an accelerated lactate clearance.

6.
Eur J Anaesthesiol ; 39(8): 695-700, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35792895

RESUMEN

BACKGROUND: The new noninvasive finger sensor system NICCI (Getinge; Gothenburg, Sweden) allows continuous cardiac output monitoring. We aimed to investigate its cardiac output measurement performance. OBJECTIVES: To investigate the NICCI system's cardiac output measurement performance. DESIGN: Prospective method comparison study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PATIENTS: Fifty-one patients after cardiac surgery. MAIN OUTCOME MEASURES: We performed a method comparison study in 51 patients after cardiac surgery to compare NICCI cardiac output (CO NICCI ) and NICCI cardiac output calibrated to pulmonary artery thermodilution cardiac output measurement (CO NICCI-CAL ) with pulmonary artery thermodilution cardiac output (CO PAT ). As a secondary analysis we also compared CNAP cardiac output (CO CNAP ) and externally calibrated CNAP cardiac output (CO CNAP-CAL ) with CO PAT . RESULTS: We analysed 299 cardiac output measurement pairs. The mean of the differences (95% limits of agreement) between CO NICCI and CO PAT was 0.6 (-1.8 to 3.1) l min -1 with a percentage error of 48%. The mean of the differences between CO NICCI-CAL and CO PAT was -0.4 (-1.9 to 1.1) l min -1 with a percentage error of 29%. The mean of the differences between CO CNAP and CO PAT was 1.0 (-1.8 to 3.8) l min -1 with a percentage error of 53%. The mean of the differences between CO CNAP-CAL and CO PAT was -0.2 (-2.0 to 1.6) l min -1 with a percentage error of 35%. CONCLUSION: The agreement between CO NICCI and CO PAT is not clinically acceptable. TRIAL REGISTRATION: The study was registered in the German Clinical Trial Register (DRKS00023189) after inclusion of the first patient on October 2, 2020.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Termodilución , Gasto Cardíaco , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Monitoreo Fisiológico/métodos , Reproducibilidad de los Resultados , Termodilución/métodos
7.
BMC Health Serv Res ; 21(1): 254, 2021 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-33743698

RESUMEN

BACKGROUND: ERAS (Enhanced Recovery After Surgery) is a multidisciplinary and integrative approach with the goal of optimizing the postoperative recovery. We aimed to analyze the economic impact of a newly established ERAS protocol in minimally invasive heart valve surgery at our institution. METHODS: ERAS protocol was implemented in 61 consecutive patients who were referred for elective minimally-invasive aortic or mitral valve surgery, between February 1, 2018 and March 31, 2019 (ERAS-group). Another 69 patients who underwent elective minimally-invasive heart valve surgery during the same time period were managed according to the hospital standards (Control-group). A detailed cost comparison analysis was carried out from a hospital perspective using a micro-costing approach. RESULTS: The total in-hospital stay was significantly shorter in the ERAS-group compared to the Control-group (6.1 ± 2.6 vs 7.7 ± 3.8 days; p = 0.008) resulting in significant cost savings of €1087.2 per patient (p = 0.003). Due to the intensified physiotherapy in the ERAS protocol, the costs for physiotherapy were €94.3 higher compared to the Control-group (p < 0.001). The total costs in the ERAS cohort were €11,200.0 ± 3029.6/patient compared to € 13,109.8 ± 4527.5/patient in the Control-Group resulting in cost savings of €1909.8 patient due to the implementation of the ERAS protocol (p = 0.006). CONCLUSION: Implementation of an ERAS-protocol in minimally-invasive cardiac surgery can be carried out safely with a fast postoperative recovery of the patient. ERAS results in a financial benefit of up to €1909 per patient and therefore will play a key role in modern cardiac surgery in the near future.


Asunto(s)
Recuperación Mejorada Después de la Cirugía , Procedimientos Quirúrgicos Electivos , Humanos , Tiempo de Internación , Procedimientos Quirúrgicos Mínimamente Invasivos , Complicaciones Posoperatorias/epidemiología , Periodo Posoperatorio
8.
BMC Med Educ ; 21(1): 353, 2021 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-34158030

RESUMEN

BACKGROUND: Many efforts of the past years aimed to build a safer health care system and hereby, non-technical skills (NTS) have been recognised to be responsible for over 70 % of preventable medical mishaps. In order to counteract those mishaps, several simulation-based trainings have been implemented in health care education to convey NTS. Still, the best and effective way to foster NTS in simulation-based training is not known. Due to the importance of NTS, this gap in knowledge needs to be filled. A possible approach to convey NTS effectively during simulation-based medical education (SBME), might be the use of the flipped learning approach. The benefits of flipped learning regarding the improvement of human factors (NTS), have not been investigated yet. Therefore, the authors introduced flipped learning as an experimental intervention into their SBME emergency trainings and aimed to analyse, whether flipped learning improved students´ NTS performance compared to lecture-based learning (LBL). METHODS: In a randomized controlled trial, 3rd year medical students participated in a SBME training and then received either a further SBME training with integrated flipped learning on NTS (intervention), or a further SBME training and an accompanying lecture on NTS (control). NTS performance was assessed on three skill dimensions with a validated behavioural marker system. RESULTS: The authors analysed NTS performance of 102 students, prior and after their allocation to each teaching method. The baseline NTS performance of both groups did not differ, whereas the intervention group enhanced significantly on all three skill dimensions (t (44) = 5.63, p < .001; t (44) = 4.47, p < .001; t (44) = 4.94, p < .001). CONCLUSION: The integration of flipped learning into SBME yields a significant improvement of NTS performance and therefore medical educators should consider the application of flipped learning to convey complex human factors and skills.


Asunto(s)
Educación Médica , Entrenamiento Simulado , Estudiantes de Medicina , Competencia Clínica , Humanos , Aprendizaje
9.
Crit Care ; 24(1): 172, 2020 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-32331527

RESUMEN

Arterial blood pressure (BP) is a fundamental cardiovascular variable, is routinely measured in perioperative and intensive care medicine, and has a significant impact on patient management. The clinical reference method for BP monitoring in high-risk surgical patients and critically ill patients is continuous invasive BP measurement using an arterial catheter. A key prerequisite for correct invasive BP monitoring using an arterial catheter is an in-depth understanding of the measurement principle, of BP waveform quality criteria, and of common pitfalls that can falsify BP readings. Here, we describe how to place an arterial catheter, correctly measure BP, and identify and solve common pitfalls. We focus on 5 important steps, namely (1) how to choose the catheter insertion site, (2) how to choose the type of arterial catheter, (3) how to place the arterial catheter, (4) how to level and zero the transducer, and (5) how to check the quality of the BP waveform.


Asunto(s)
Presión Arterial , Determinación de la Presión Sanguínea/métodos , Dispositivos de Acceso Vascular , Determinación de la Presión Sanguínea/instrumentación , Enfermedad Crítica/terapia , Guías como Asunto , Humanos , Unidades de Cuidados Intensivos/organización & administración , Monitoreo Fisiológico/métodos , Posicionamiento del Paciente/instrumentación , Posicionamiento del Paciente/métodos , Ultrasonografía Intervencional/métodos
10.
Crit Care ; 24(1): 374, 2020 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-32576244

RESUMEN

An amendment to this paper has been published and can be accessed via the original article.

11.
Nature ; 509(7502): 641-4, 2014 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-24747400

RESUMEN

Despite the introduction of antiproliferative drug-eluting stents, coronary heart disease remains the leading cause of death in the United States. In-stent restenosis and bypass graft failure are characterized by excessive smooth muscle cell (SMC) proliferation and concomitant myointima formation with luminal obliteration. Here we show that during the development of myointimal hyperplasia in human arteries, SMCs show hyperpolarization of their mitochondrial membrane potential (ΔΨm) and acquire a temporary state with a high proliferative rate and resistance to apoptosis. Pyruvate dehydrogenase kinase isoform 2 (PDK2) was identified as a key regulatory protein, and its activation proved necessary for relevant myointima formation. Pharmacologic PDK2 blockade with dichloroacetate or lentiviral PDK2 knockdown prevented ΔΨm hyperpolarization, facilitated apoptosis and reduced myointima formation in injured human mammary and coronary arteries, rat aortas, rabbit iliac arteries and swine (pig) coronary arteries. In contrast to several commonly used antiproliferative drugs, dichloroacetate did not prevent vessel re-endothelialization. Targeting myointimal ΔΨm and alleviating apoptosis resistance is a novel strategy for the prevention of proliferative vascular diseases.


Asunto(s)
Aorta/lesiones , Arterias/lesiones , Constricción Patológica/prevención & control , Ácido Dicloroacético/farmacología , Ácido Dicloroacético/uso terapéutico , Túnica Íntima/efectos de los fármacos , Túnica Íntima/patología , Angioplastia de Balón/efectos adversos , Animales , Aorta/efectos de los fármacos , Aorta/patología , Apoptosis/efectos de los fármacos , Arterias/efectos de los fármacos , Arterias/patología , Proliferación Celular/efectos de los fármacos , Constricción Patológica/patología , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/lesiones , Vasos Coronarios/patología , Modelos Animales de Enfermedad , Activación Enzimática/efectos de los fármacos , Técnicas de Silenciamiento del Gen , Humanos , Hiperplasia/tratamiento farmacológico , Hiperplasia/patología , Arteria Ilíaca/efectos de los fármacos , Arteria Ilíaca/lesiones , Arteria Ilíaca/patología , Arterias Mamarias/efectos de los fármacos , Arterias Mamarias/lesiones , Arterias Mamarias/patología , Potencial de la Membrana Mitocondrial/efectos de los fármacos , Mitocondrias Cardíacas/efectos de los fármacos , Mitocondrias Cardíacas/metabolismo , Miocitos del Músculo Liso/efectos de los fármacos , Miocitos del Músculo Liso/patología , Proteínas Serina-Treonina Quinasas/antagonistas & inhibidores , Proteínas Serina-Treonina Quinasas/deficiencia , Proteínas Serina-Treonina Quinasas/genética , Piruvato Deshidrogenasa Quinasa Acetil-Transferidora , Conejos , Ratas , Prevención Secundaria , Stents/efectos adversos , Porcinos , Túnica Íntima/lesiones
12.
Eur J Anaesthesiol ; 37(10): 920-925, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32398582

RESUMEN

BACKGROUND: Invasive pulse wave analysis is used in peri-operative settings to estimate cardiac output (CO). The 'pressure recording analytical method' (PRAM) implemented in the MostCareUp CO monitor is an invasive pulse wave analysis method using high-frequency sampling and analysis of the pulse wave to directly estimate the arterial impedance as a key variable of the proprietary CO estimation algorithm. OBJECTIVE: To compare CO estimated by PRAM (PRAM-CO; test method) with CO measured by pulmonary artery thermodilution (PATD-CO; reference method). DESIGN: Prospective observational method comparison study. PRAM-CO and PATD-CO were assessed simultaneously at five time points with at least 20 min between measurements. Arterial pressure waveforms were carefully checked for damping artefacts and a proprietary electronic filter of the MostCareUp CO monitor was used to optimise waveform quality. SETTING: ICU of a German university hospital from August 2018 until April 2019. PATIENTS: We included adult patients admitted to the ICU after elective off-pump coronary artery bypass surgery who were monitored with a radial arterial catheter and a pulmonary artery catheter. Patients with severe heart valve insufficiency or persistent arrhythmia were excluded. MAIN OUTCOME MEASURES AND ANALYSIS: PATD-CO and PRAM-CO were compared using Bland-Altman analysis accounting for repeated measurements, the percentage error and trending analysis (four-quadrant plot, concordance rate). RESULTS: We analysed 195 paired CO values of 41 patients. Mean PATD-CO and PRAM-CO were 4.99 ±â€Š1.02 and 4.92 ±â€Š1.05 l min, respectively. PATD-CO and PRAM-CO ranged from 3.04 to 8.74 and 2.79 to 8.01 l min, respectively. The mean of the differences between PATD-CO and PRAM-CO was -0.08 ±â€Š0.74 l min with 95% limits of agreement of -1.55 to +1.40 l min. The percentage error was 29.8%. The concordance rate in four-quadrant plot analysis was 92%. CONCLUSION: Using the system's electronic waveform filter PRAM-CO shows good agreement and trending ability compared with PATD-CO in adults after off-pump coronary artery bypass surgery.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Termodilución , Adulto , Gasto Cardíaco , Humanos , Arteria Pulmonar , Análisis de la Onda del Pulso , Reproducibilidad de los Resultados
13.
BMC Med Educ ; 20(1): 351, 2020 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-33032572

RESUMEN

BACKGROUND: Non-technical skills (NTS) are an indispensable element of emergency care and need to be prevalent alongside with good technical skills. Though, questions of how to teach (instructional design) and improve NTS effectively remain unresolved. One adjustment screw to enhance performance of NTS, which is detached from instructional designs and learning efforts might be motivation. Theoretical models and observational studies suggest that high levels of intrinsic (situational) motivation result in better performance and better learning. Therefore, this study analyzed the influence of motivation on performance of NTS, by exploring if high levels of intrinsic motivation lead to better performance of NTS in medical students. METHODS: In this prospective cross-sectional cohort study, the authors assessed the correlation of situational motivation and performance of NTS within a cohort of 449 undergraduates in their 1st to 4th year of medical studies, in a total of 101 emergency simulation trainings. Situational motivation was measured with the validated Situational Motivation Scale (SIMS), which was completed by every undergraduate directly before each simulation training. The NTS were evaluated with the Anesthesiology Students´ Non-Technical skills (AS-NTS) rating tool, a validated taxonomy, especially developed to rate NTS of undergraduates. RESULTS: Student situational motivation was weakly correlated with their performance of NTS in simulation-based emergency trainings. CONCLUSION: Although motivation has been emphasized as a determining factor, enhancing performance in different fields and in medicine in particular, in our study, student situational motivation was independent from their performance of NTS in simulation-based emergency trainings (SBET).


Asunto(s)
Entrenamiento Simulado , Estudiantes de Medicina , Competencia Clínica , Estudios Transversales , Humanos , Motivación , Estudios Prospectivos
14.
Thorax ; 74(3): 219-228, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30636196

RESUMEN

BACKGROUND: In acute respiratory distress syndrome (ARDS), pulmonary perfusion failure increases physiologic dead space ventilation (VD/VT), leading to a decline of the alveolar CO2 concentration [CO2]iA. Although it has been shown that alveolar hypocapnia contributes to formation of atelectasis and surfactant depletion, a typical complication in ARDS, the underlying mechanism has not been elucidated so far. METHODS: In isolated perfused rat lungs, cytosolic or mitochondrial Ca2+ concentrations ([Ca2+]cyt or [Ca2+]mito, respectively) of alveolar epithelial cells (AECs), surfactant secretion and the projected area of alveoli were quantified by real-time fluorescence or bright-field imaging (n=3-7 per group). In ventilated White New Zealand rabbits, the left pulmonary artery was ligated and the size of subpleural alveoli was measured by intravital microscopy (n=4 per group). Surfactant secretion was determined in the bronchoalveolar lavage (BAL) by western blot. RESULTS: Low [CO2]iA decreased [Ca2+]cyt and increased [Ca2+]mito in AECs, leading to reduction of Ca2+-dependent surfactant secretion, and alveolar ventilation in situ. Mitochondrial inhibition by ruthenium red or rotenone blocked these responses indicating that mitochondria are key players in CO2 sensing. Furthermore, ligature of the pulmonary artery of rabbits decreased alveolar ventilation, surfactant secretion and lung compliance in vivo. Addition of 5% CO2 to the inspiratory gas inhibited these responses. CONCLUSIONS: Accordingly, we provide evidence that alveolar hypocapnia leads to a Ca2+ shift from the cytosol into mitochondria. The subsequent decline of [Ca2+]cyt reduces surfactant secretion and thus regional ventilation in lung regions with high VD/VT. Additionally, the regional hypoventilation provoked by perfusion failure can be inhibited by inspiratory CO2 application.


Asunto(s)
Hipocapnia/etiología , Mitocondrias/fisiología , Surfactantes Pulmonares/metabolismo , Síndrome de Dificultad Respiratoria/etiología , Volumen de Ventilación Pulmonar/fisiología , Animales , Modelos Animales de Enfermedad , Alveolos Pulmonares/irrigación sanguínea , Ratas , Síndrome de Dificultad Respiratoria/metabolismo , Síndrome de Dificultad Respiratoria/fisiopatología
15.
BMC Med Educ ; 19(1): 205, 2019 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-31196070

RESUMEN

BACKGROUND: Non-Technical Skills (NTS) are becoming more important in medical education. A lack of NTS was identified as a major reason for unsafe patient care, favouring adverse events and team breakdown. Therefore, the training of NTS should already be implemented in undergraduate teaching. The goal of our study was to develop and validate the Anaesthesiology Students' Non-Technical Skills (AS-NTS) as a feasible rating tool to assess students' NTS in emergency and anaesthesiology education. METHODS: The development of AS-NTS was empirically grounded in expert- and focus groups, field observations and data from NTS in medical fields. Validation, reliability and usability testing was conducted in 98 simulation scenarios, during emergency and anaesthesiology training sessions. RESULTS: AS-NTS showed an excellent interrater reliability (mean 0.89), achieved excellent content validity indexes (at least 0.8) and was rated as feasible and applicable by educators. Additionally, we could rule out the influence of the raters' anaesthesiology and emergency training and experience in education on the application of the rating tool. CONCLUSIONS: AS-NTS provides a structured approach to the assessment of NTS in undergraduates, providing accurate feedback. The findings of usability, validity and reliability indicate that AS-NTS can be used by anaesthesiologists in different year of postgraduate training, even with little experience in medical education.


Asunto(s)
Anestesiología/educación , Competencia Clínica , Evaluación Educacional , Estudiantes de Medicina , Adulto , Cuidados Críticos , Educación Médica , Femenino , Alemania , Humanos , Entrevistas como Asunto , Masculino
16.
Anesth Analg ; 136(6): e27-e28, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37205810
18.
J Clin Monit Comput ; 32(2): 235-244, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28540614

RESUMEN

The CNAP technology (CNSystems Medizintechnik AG, Graz, Austria) allows continuous noninvasive arterial pressure waveform recording based on the volume clamp method and estimation of cardiac output (CO) by pulse contour analysis. We compared CNAP-derived CO measurements (CNCO) with intermittent invasive CO measurements (pulmonary artery catheter; PAC-CO) in postoperative cardiothoracic surgery patients. In 51 intensive care unit patients after cardiothoracic surgery, we measured PAC-CO (criterion standard) and CNCO at three different time points. We conducted two separate comparative analyses: (1) CNCO auto-calibrated to biometric patient data (CNCObio) versus PAC-CO and (2) CNCO calibrated to the first simultaneously measured PAC-CO value (CNCOcal) versus PAC-CO. The agreement between the two methods was statistically assessed by Bland-Altman analysis and the percentage error. In a subgroup of patients, a passive leg raising maneuver was performed for clinical indications and we present the changes in PAC-CO and CNCO in four-quadrant plots (exclusion zone 0.5 L/min) in order to evaluate the trending ability of CNCO. The mean difference between CNCObio and PAC-CO was +0.5 L/min (standard deviation ± 1.3 L/min; 95% limits of agreement -1.9 to +3.0 L/min). The percentage error was 49%. The concordance rate was 100%. For CNCOcal, the mean difference was -0.3 L/min (±0.5 L/min; -1.2 to +0.7 L/min) with a percentage error of 19%. In this clinical study in cardiothoracic surgery patients, CNCOcal showed good agreement when compared with PAC-CO. For CNCObio, we observed a higher percentage error and good trending ability (concordance rate 100%).


Asunto(s)
Gasto Cardíaco , Procedimientos Quirúrgicos Cardíacos/métodos , Monitoreo Fisiológico/instrumentación , Arteria Pulmonar/patología , Anciano , Algoritmos , Calibración , Cateterismo , Cuidados Críticos , Enfermedad Crítica , Femenino , Hemodinámica , Humanos , Unidades de Cuidados Intensivos , Masculino , Periodo Posoperatorio , Reproducibilidad de los Resultados , Tamaño de la Muestra , Termodilución
20.
J Clin Anesth ; 95: 111459, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599161

RESUMEN

STUDY OBJECTIVE: Processed electroencephalography (pEEG) may help clinicians optimize depth of general anesthesia. Avoiding excessive depth of anesthesia may reduce intraoperative hypotension and the need for vasopressors. We tested the hypothesis that pEEG-guided - compared to non-pEEG-guided - general anesthesia reduces the amount of norepinephrine needed to keep intraoperative mean arterial pressure above 65 mmHg in patients having vascular surgery. DESIGN: Randomized controlled clinical trial. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PATIENTS: 110 patients having vascular surgery. INTERVENTIONS: pEEG-guided general anesthesia. MEASUREMENTS: Our primary endpoint was the average norepinephrine infusion rate from the beginning of induction of anesthesia until the end of surgery. MAIN RESULT: 96 patients were analyzed. The mean ± standard deviation average norepinephrine infusion rate was 0.08 ± 0.04 µg kg-1 min-1 in patients assigned to pEEG-guided and 0.12 ± 0.09 µg kg-1 min-1 in patients assigned to non-pEEG-guided general anesthesia (mean difference 0.04 µg kg-1 min-1, 95% confidence interval 0.01 to 0.07 µg kg-1 min-1, p = 0.004). Patients assigned to pEEG-guided versus non-pEEG-guided general anesthesia, had a median time-weighted minimum alveolar concentration of 0.7 (0.6, 0.8) versus 0.8 (0.7, 0.8) (p = 0.006) and a median percentage of time Patient State Index was <25 of 12 (1, 41) % versus 23 (3, 49) % (p = 0.279). CONCLUSION: pEEG-guided - compared to non-pEEG-guided - general anesthesia reduced the amount of norepinephrine needed to keep mean arterial pressure above 65 mmHg by about a third in patients having vascular surgery. Whether reduced intraoperative norepinephrine requirements resulting from pEEG-guided general anesthesia translate into improved patient-centered outcomes remains to be determined in larger trials.


Asunto(s)
Anestesia General , Electroencefalografía , Norepinefrina , Procedimientos Quirúrgicos Vasculares , Vasoconstrictores , Humanos , Anestesia General/métodos , Norepinefrina/administración & dosificación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Electroencefalografía/efectos de los fármacos , Procedimientos Quirúrgicos Vasculares/efectos adversos , Vasoconstrictores/administración & dosificación , Hipotensión/prevención & control , Presión Arterial/efectos de los fármacos , Monitoreo Intraoperatorio/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA