Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Strahlenther Onkol ; 200(1): 19-27, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37429949

RESUMEN

PURPOSE: To analyze tumor characteristics derived from pelvic magnetic resonance imaging (MRI) of patients with squamous cell carcinoma of the anus (SCCA) before and during chemoradiotherapy (CRT), and to compare the changes in these characteristics between scans of responders vs. nonresponders to CRT. METHODS: We included 52 patients with a pelvic 3T MRI scan prior to CRT (baseline scan); 39 of these patients received an additional scan during week 2 of CRT (second scan). Volume, diameter, extramural tumor depth (EMTD), and external anal sphincter infiltration (EASI) of the tumor were assessed. Mean, kurtosis, skewness, standard deviation (SD), and entropy values were extracted from apparent diffusion coefficient (ADC) histograms. The main outcome was locoregional treatment failure. Correlations were evaluated with Wilcoxon's signed rank-sum test and Pearson's correlation coefficient, quantile regression, univariate logistic regression, and area under the ROC curve (AUC) analyses. RESULTS: In isolated analyses of the baseline and second MRI scans, none of the characteristics were associated with outcome. Comparison between the scans showed significant changes in several characteristics: volume, diameter, EMTD, and ADC skewness decreased in the second scan, although the mean ADC increased. Small decreases in volume and diameter were associated with treatment failure, and these variables had the highest AUC values (0.73 and 0.76, respectively) among the analyzed characteristics. CONCLUSION: Changes in tumor volume and diameter in an early scan during CRT could represent easily assessable imaging-based biomarkers to eliminate the need for analysis of more complex MRI characteristics.


Asunto(s)
Neoplasias del Ano , Neoplasias del Recto , Humanos , Neoplasias del Recto/patología , Imagen por Resonancia Magnética/métodos , Resultado del Tratamiento , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias del Ano/diagnóstico por imagen , Neoplasias del Ano/terapia , Quimioradioterapia/métodos , Estudios Retrospectivos
2.
J Appl Clin Med Phys ; 25(4): e14192, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37962032

RESUMEN

OBJECTIVE: This study assesses the robustness of first-order radiomic texture features namely interquartile range (IQR), coefficient of variation (CV) and standard deviation (SD) derived from computed tomography (CT) images by varying dose, reconstruction algorithms and slice thickness using scans of a uniform water phantom, a commercial anthropomorphic liver phantom, and a human liver in-vivo. MATERIALS AND METHODS: Scans were acquired on a 16 cm detector GE Revolution Apex Edition CT scanner with variations across three different nominal slice thicknesses: 0.625, 1.25, and 2.5 mm, three different dose levels: CTDIvol of 13.86 mGy for the standard dose, 40% reduced dose and 60% reduced dose and two different reconstruction algorithms: a deep learning image reconstruction (DLIR-high) algorithm and a hybrid iterative reconstruction (IR) algorithm ASiR-V50% (AV50) were explored, varying one at a time. To assess the effect of non-linear modifications of images by AV50 and DLIR-high, images of the water phantom were also reconstructed using filtered back projection (FBP). Quantitative measures of IQR, CV and SD were extracted from twelve pre-selected, circular (1 cm diameter) regions of interest (ROIs) capturing different texture patterns across all scans. RESULTS: Across all scans, imaging, and reconstruction settings, CV, IQR and SD were observed to increase with reduction in dose and slice thickness. An exception to this observation was found when using FBP reconstruction. Lower values of CV, IQR and SD were observed in DLIR-high reconstructions compared to AV50 and FBP. The Poisson statistics were more stringently noted in FBP than DLIR-high and AV50, due to the non-linear nature of the latter two algorithms. CONCLUSION: Variation in image noise due to dose reduction algorithms, tube current, and slice thickness show a consistent trend across phantom and patient scans. Prospective evaluation across multiple centers, scanners and imaging protocols is needed for establishing quality assurance standards of radiomics.


Asunto(s)
Algoritmos , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Agua , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos
3.
J Appl Clin Med Phys ; 25(4): e14309, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38386922

RESUMEN

OBJECTIVE: This study identifies key characteristics to help build a physical liver computed tomography (CT) phantom for radiomics harmonization; particularly, the higher-order texture metrics. MATERIALS AND METHODS: CT scans of a radiomics phantom comprising of 18 novel 3D printed inserts with varying size, shape, and material combinations were acquired on a 64-slice CT scanner (Brilliance 64, Philips Healthcare). The images were acquired at 120 kV, 250 mAs, CTDIvol of 16.36 mGy, 2 mm slice thickness, and iterative noise-reduction reconstruction (iDose, Philips Healthcare, Andover, MA). Radiomics analysis was performed using the Cancer Imaging Phenomics Toolkit (CaPTk), following automated segmentation of 3D regions of interest (ROI) of the 18 inserts. The findings were compared to three additional ROI obtained of an anthropomorphic liver phantom, a patient liver CT scan, and a water phantom, at comparable imaging settings. Percentage difference in radiomic metrics values between phantom and tissue was used to assess the biological equivalency and <10% was used to claim equivalent. RESULTS: The HU for all 18 ROI from the phantom ranged from -30 to 120 which is within clinically observed HU range of the liver, showing that our phantom material (T3-6B) is representative of biological CT tissue densities (liver) with >50% radiomic features having <10% difference from liver tissue. Based on the assessment of the Neighborhood Gray Tone Difference Matrix (NGTDM) metrics it is evident that the water phantom ROI show extreme values compared to the ROIs from the phantom. This result may further reinforce the difference between a structureless quantity such as water HU values and tissue HU values found in liver. CONCLUSION: The 3-D printed patterns of the constructed radiomics phantom cover a wide span of liver tissue textures seen in CT images. Using our results, texture metrics can be selectively harmonized to establish clinically relevant and reliable radiomics panels.


Asunto(s)
Radiómica , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Tomógrafos Computarizados por Rayos X , Fantasmas de Imagen , Hígado/diagnóstico por imagen , Agua , Procesamiento de Imagen Asistido por Computador/métodos
4.
Surg Endosc ; 37(12): 9283-9290, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37880446

RESUMEN

BACKGROUND AND AIMS: The functional luminal imaging probe (FLIP) can provide measurements of lower esophageal sphincter (LES) distensibility. Studies report that use of intraoperative FLIP examination during peroral endoscopic myotomy (POEM) for achalasia is associated with treatment success, but evidence is limited and inconsistent. The main aim of the present study was to assess associations between intraoperative FLIP values and 1-year outcomes. Additionally, associations between 1-year FLIP measurements and other 1-year outcome variables were studied. METHODS: We performed a single-center prospective study of consecutive achalasia patients treated with POEM with a standardized 1-year follow-up. The inclusion period was from June 2017 to January 2020. We compared 1-year outcomes (FLIP measurement values, Eckardt score (ES), reflux esophagitis, timed barium esophagogram (TBE), and lower esophageal sphincter resting pressure (LES-rp)) in patients with and without intraoperative FLIP examination. We also assessed associations between intraoperative FLIP values, 1-year FLIP values, and other 1-year outcomes. Results are given as median (IQR), and non-parametrical statistical analyses were applied. RESULTS: Sixty-two patients (27 females) with median age 45 years (35-54) were included. Baseline characteristics were similar in patients with (n = 32) and without (n = 30) intraoperative FLIP examination. In patients with intraoperative FLIP, ES was 2 (1-3) and LES distensibility index (DI) 3.7 (2.6-5.4) after 1 year, compared with ES 2 (1-3) and DI 4.0 (3.1-6.8)) in patients without intraoperative FLIP (ns). Intraoperative DI was not correlated with 1-year ES or DI. One-year DI correlated significantly with 1-year ES (rs - 0.42), TBE (rs - 0.34), and LES-rp (rs - 0.29). CONCLUSIONS: Use of intraoperative FLIP measurements in POEM for achalasia is not associated with improved 1-year outcome, and the clinical value of intraoperative FLIP in POEM for achalasia is questioned. Follow-up FLIP measurements are moderately associated with symptomatic outcome, and may serve as an additional diagnostic modality in post-treatment evaluation.


Asunto(s)
Acalasia del Esófago , Cirugía Endoscópica por Orificios Naturales , Femenino , Humanos , Persona de Mediana Edad , Acalasia del Esófago/diagnóstico , Estudios de Seguimiento , Estudios Prospectivos , Cirugía Endoscópica por Orificios Naturales/métodos , Esfínter Esofágico Inferior/cirugía , Resultado del Tratamiento , Esofagoscopía/métodos
5.
Acta Orthop ; 94: 207-214, 2023 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-37114404

RESUMEN

BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is the gold standard for migration analysis, but computed tomography analysis methods (CTRSA) have shown comparable results in other joints. We attempted to validate precision for CT compared with RSA for a tibial implant. MATERIAL AND METHODS: RSA and CT were performed on a porcine knee with a tibial implant. Marker-based RSA, model-based RSA (MBRSA), and CT scans from 2 different manufacturers were compared. CT analysis was performed by 2 raters for reliability evaluation. RESULTS: 21 double examinations for precision measurements for RSA and CT-based Micromotion Analysis (CTMA) were analysed. Mean (95% confidence interval) precision data for maximum total point motion (MTPM) using marker-based RSA was 0.45 (0.19-0.70) and 0.58 (0.20-0.96) using MBRSA (F-statistic 0.44 [95% CI 0.18-1.1], p = 0.07). Precision data for total translation (TT) for CTMA was 0.08 (0.03-0.12) for the GE scanner and 0.11 (0.04-0.19) for the Siemens scanner (F-statistic 0.37 [0.15-0.91], p = 0.03). When comparing the aforementioned precision for both RSA methods with both CTMA analyses, CTMA was more precise (p < 0.001). The same pattern was seen for other translations and migrations. Mean effective radiation doses were 0.005 mSv (RSA) (0.0048-0.0050) and 0.08 mSv (CT) (0.078-0.080) (p < 0.001). Intra- and interrater reliability were 0.79 (0.75-0.82) and 0.77 (0.72-0.82), respectively. CONCLUSION: CTMA is more precise than RSA for migration analysis of a tibial implant, has overall good intra- and interrater reliability but higher effective radiation doses in a porcine cadaver.


Asunto(s)
Prótesis de Cadera , Análisis Radioestereométrico , Porcinos , Animales , Análisis Radioestereométrico/métodos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Cadáver
6.
Acta Orthop ; 94: 550-544, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37909103

RESUMEN

BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is the gold standard for evaluation of migration of implants. CT-RSA has been shown to have precision at the level of RSA in hip, shoulder, and knee joint replacements. We aimed to assess the impact of dose reduction on precision of CT-RSA on tibial implants, comparing it with previously published data on precision of standard dose CT-RSA on tibial implants. MATERIAL AND METHODS: We performed a total knee arthroplasty on a porcine knee cadaver, and subsequent CT-RSA with low effective doses (0.02 mSv). We compared the results with previously published CT-RSA data with standard (0.08 mSv) dose. The primary outcome variable was the difference in precision of the maximum total translation (MTT). Secondary variables included ratios of variances and standard deviations, and precision of peripheral point translations, center-of-mass translations, and rotations. A difference of more than 0.1 mm in precision was defined as clinically relevant. Our hypothesis was that precisions of low and standard CT-RSA doses were equal. RESULTS: Low dose (mean 0.07, 95% confidence interval [CI] 0.06-0.08) and standard dose CT-RSA (0.08, CI 0.07-0.09) achieve similar precision, with difference in precision of MTT of 0.01, CI 0.00-0.02 mm. The F-statistic (0.99, CI 0.63-1.55) and sdtest (1.05, CI 0.43-2.58) also supported this. CONCLUSION: We conclude that the precision of low dose CT-RSA for tibial implants on a porcine cadaver is equal to standard dose CT-RSA. However, these findings should be confirmed in clinical trials.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Análisis Radioestereométrico , Porcinos , Animales , Análisis Radioestereométrico/métodos , Reducción Gradual de Medicamentos , Tomografía Computarizada por Rayos X/métodos , Cadáver
7.
HPB (Oxford) ; 24(7): 1055-1062, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34924292

RESUMEN

BACKGROUND: Many patients undergoing resection for colorectal liver metastases (CRLM) recur with poor survival. Overall survival (OS) following liver transplantation (LT) for CRLM is reported to be about 80% at 5 years. In this study, survival following resection versus transplantation for CRLM in patients with moderate (6-70 cm3) metabolic tumor volume (MTV) from the preoperative positron emission tomography (PET) was compared. METHODS: Disease-free survival (DFS), OS and post recurrence survival (PRS) following resection (n = 18) and LT (n = 12) was compared by using the Kaplan Meier method and log rank test for patients with moderate MTV. RESULTS: Patients undergoing LT had unresectable metastases, significantly lower age, higher tumor burden score and number of liver metastases, longer time from diagnosis to surgery, and more patients received neoadjuvant chemotherapy. OS at 5 years was 39% in the resection group and 83% in the LT group (P = 0.012). PRS was significantly improved in patients treated with LT compared to resection with 71% alive at 5 years from recurrence compared to 17% in the resection group (P = 0.017). CONCLUSION: LT for selected patients seems to be superior to resection as treatment for CRLM for patients with moderate MTV.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Trasplante de Hígado , Neoplasias Colorrectales/patología , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Trasplante de Hígado/efectos adversos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Estudios Retrospectivos , Carga Tumoral
8.
Emerg Radiol ; 28(1): 37-46, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32686046

RESUMEN

PURPOSE: To evaluate whether an arterial phase scan improves the diagnostic performance of computed tomography to identify pelvic trauma patients who received angiographic intervention on demand of the trauma surgeon. METHODS: This retrospective single-center study was performed at an academic Scandinavian trauma center with approximately 2000 trauma admissions annually. Pelvic trauma patients with arterial and portal venous phase CT from 2009 to 2015 were included. The patients were identified from the institutional trauma registry. Images were interpreted by two radiologists with more than 10 years of trauma radiology experience. Positive findings for extravasation on portal venous phase alone or on both arterial and portal venous phase were compared, with angiographic intervention as clinical outcome. RESULTS: One hundred fifty-seven patients (54 females, 103 males) with a median age of 45 years were enrolled. Sixteen patients received angiographic intervention. Positive CT findings on portal venous phase only had a sensitivity and specificity of 62% and 86%, vs. 56% and 93% for simultaneous findings on arterial and portal venous phase. Specificity was significantly higher for positive findings in both phases compared with portal venous phase only. Applying a threshold > 0.9 cm of extravasation diameter to portal venous phase only resulted in sensitivity and specificity identical to those of both phases. CONCLUSION: Arterial phase scan in addition to portal venous phase scan did not improve patient selection for angiography. Portal venous phase extravasation size alone may be used as an imaging-based biomarker of the need for angiographic intervention.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Huesos Pélvicos/lesiones , Heridas no Penetrantes/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Puntaje de Gravedad del Traumatismo , Yopamidol/análogos & derivados , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Sensibilidad y Especificidad , Centros Traumatológicos
9.
Acta Radiol ; 60(3): 356-366, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29860889

RESUMEN

BACKGROUND: Texture analysis has been done on several radiological modalities to stage, differentiate, and predict prognosis in many oncologic tumors. PURPOSE: To determine the diagnostic accuracy of discriminating glioblastoma (GBM) from single brain metastasis (MET) by assessing the heterogeneity of both the solid tumor and the peritumoral edema with magnetic resonance imaging (MRI) texture analysis (MRTA). MATERIAL AND METHODS: Preoperative MRI examinations done on a 3-T scanner of 43 patients were included: 22 GBM and 21 MET. MRTA was performed on diffusion tensor imaging (DTI) in a representative region of interest (ROI). The MRTA was assessed using a commercially available research software program (TexRAD) which applies a filtration histogram technique for characterizing tumor and peritumoral heterogeneity. The filtration step selectively filters and extracts texture features at different anatomical scales varying from 2 mm (fine) to 6 mm (coarse). Heterogeneity quantification was obtained by the statistical parameter entropy. A threshold value to differentiate GBM from MET with sensitivity and specificity was calculated by receiver operating characteristic (ROC) analysis. RESULTS: Quantifying the heterogeneity of the solid part of the tumor showed no significant difference between GBM and MET. However, the heterogeneity of the GBMs peritumoral edema was significantly higher than the edema surrounding MET, differentiating them with a sensitivity of 80% and specificity of 90%. CONCLUSION: Assessing the peritumoral heterogeneity can increase the radiological diagnostic accuracy when discriminating GBM and MET. This will facilitate the medical staging and optimize the planning for surgical resection of the tumor and postoperative management.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Imagen de Difusión Tensora/métodos , Glioblastoma/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Metástasis de la Neoplasia/diagnóstico por imagen , Adulto , Anciano , Edema Encefálico/diagnóstico por imagen , Edema Encefálico/patología , Neoplasias Encefálicas/patología , Diagnóstico Diferencial , Femenino , Glioblastoma/patología , Humanos , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia/patología , Sensibilidad y Especificidad , Programas Informáticos
11.
Acta Radiol ; 59(9): 1038-1044, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29350048

RESUMEN

Background Split-bolus computed tomography (CT) is a recent development in trauma imaging. Instead of multiple scans in different contrast phases after a single contrast bolus, split-bolus protocols consist of one single scan of the thorax and abdomen after two or three contrast injections at different points of time. Purpose To evaluate and compare image quality and injury findings of a new triple-split-bolus CT (TS-CT) protocol of thorax and abdomen with those of a portal venous phase CT (PV-CT) in the same patient group. Material and Methods Trauma patients in 2009-2012 who underwent both the TS-CT initially and a PV-CT during the next six weeks were included. The TS-CT examination was performed as one CT run after application of three contrast boluses (total 175 mL) to enhance renal pelvis and urinary tract, the abdominal organs, and the large arterial vessels. The PV-CT had a fixed delay of 85 s. We measured attenuation in Hounsfield units (HU), evaluated possible organ injury and assessed image quality on a 5-point scale. Results Thirty-five patients were included. Attenuation measurements of major abdominal vessels, organs, and renal pelvis were significantly higher with the TS-CT protocol. Performance in organ injury diagnosis and image quality was equal in both protocols. Conclusion The overall performance of the TS-CT protocol is similar to the standard PV-CT. Excellent visualization of the arterial tree and the collecting system may eliminate the need for separate scans.


Asunto(s)
Medios de Contraste/administración & dosificación , Yopamidol/análogos & derivados , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Heridas y Lesiones/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Yopamidol/administración & dosificación , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
Acta Radiol ; 57(9): 1040-8, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26622057

RESUMEN

BACKGROUND: Meticulous imaging of colorectal liver metastases (CRLM) is mandatory to optimize outcome after liver resection. However, the detection of CRLM is still challenging. PURPOSE: To evaluate prospectively if magnetic resonance imaging (MRI) with diffusion-weighted and Gd-EOB-DTPA-enhanced sequences had a better diagnostic performance for CRLM compared to computed tomography (CT) and fluorine-18 fluorodeoxyglucose positron emission tomography (PET/CT). MATERIAL AND METHODS: Forty-six patients scheduled for resection of suspected CRLM were evaluated prospectively from September 2011 to January 2013. None of the patients had undergone previous treatment for their CRLM. Multiphase CT, liver MRI with diffusion-weighted and dynamic Gd-EOB-DTPA-enhanced sequences and low-dose PET/CT were performed. Two independent, blinded readers evaluated the examinations. The reference standard was histopathological confirmation (81/140 CRLM) or follow-up. RESULTS: A total of 140 CRLM and 196 benign lesions were identified. On a per-lesion basis, MRI had the significantly highest sensitivity overall and for CRLM < 10 mm (P < 0.001). Overall sensitivity/specificity and PPV/NPV were 68%/94% and 89%/81% for CT, 90%/87% and 82%/93% for MRI, and 61%/99% and 97%/78% for PET/CT. For CRLM < 10 mm it was 16%/96% and 54%/80% for CT, 74%/88% and 64%/93% for MRI, and 9%/98% and 57%/79% for PET/CT. CONCLUSION: MRI had the significantly highest sensitivity compared with CT and PET/CT, particularly for CRLM < 10 mm. Therefore, detection of CRLM should be based on MRI.


Asunto(s)
Neoplasias Colorrectales/patología , Imagen de Difusión por Resonancia Magnética , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Fluorodesoxiglucosa F18 , Gadolinio DTPA , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Radiofármacos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
14.
Acta Radiol Open ; 13(5): 20584601241241523, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38645439

RESUMEN

Background: In staging early rectal cancers (ERC), submucosal tumor depth is one of the most important features determining the possibility of local excision (LE). The micro-enema (Bisacodyl) induces submucosal edema and may hypothetically improve the visualization of tumor depth. Purpose: To test the diagnostic performance of MRI to identify ERC suitable for LE when adding a pre-procedural micro-enema and concurrent use of a modified classification system. Material and Methods: In this prospective study, we consecutively included 73 patients with newly diagnosed rectal tumors. Two experienced radiologists independently interpreted the MRI examinations, and diagnostic performance was calculated for local tumors eligible for LE (Tis-T1sm2, n = 43) and non-local tumors too advanced for LE (T1sm3-T3b, n = 30). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were registered for each reader. Inter- and intra-reader agreements were assessed by kappa statistics. Lymph node status was derived from the clinical MRI reports. Results: Reader1/reader2 achieved sensitivities of 93%/86%, specificities of 90%/83%, PPV of 93%/88%, and NPV of 90%/81%, respectively, for identifying tumors eligible for LE. Rates of overstaging of local tumors were 7% and 14% for the two readers, and kappa values for the inter- and intra-reader agreement were 0.69 and 0.80, respectively. For tumors ≤T2, all metastatic lymph nodes were smaller than 3 mm on histopathology. Conclusion: MRI after a rectal micro-enema and concurrent use of a modified staging system achieved good diagnostic performance to identify tumors suitable for LE. The rate of overstaging of local tumors was comparable to results reported in previous endorectal ultrasound (ERUS) studies.

15.
J Exp Orthop ; 10(1): 83, 2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37584812

RESUMEN

PURPOSE: Ligament balancing is a prerequisite for good function and survival in total knee arthroplasty (TKA). Various balancing techniques exist, but none have shown superior results. The pie-crusting technique by Bellemans of the medial collateral ligament is commonly utilized; however, it can be difficult to achieve repeatable ligament lengthening with this technique. Therefore, we invented a novel instrument to standardize the pie-crusting technique of the superficial and deep medial collateral ligament (hereafter MCL). The purpose was to examine if pie-crusting with the instrument could produce repeatable ligament lengthening. METHODS: The MCL was isolated in 16 human cadaveric knees, and subjected to axial tension. The instrument was composed of a specific grid of holes in rows, used to guide sequential pie-crusting puncturing of the MCL with a Ø1.6 mm end-cutting cannula. Ligament lengthening was measured after each row of punctures. Regression analysis was performed on the results. RESULTS: Mean lengthening ± SD in human cadaveric MCL for puncturing of row 1 in the instrument was 0.06 ± 0.09 mm, 0.06 ± 0.04 mm for row 2, 0.09 ± 0.08 mm for row 3, 0.06 ± 0.05 mm for row 4 and 0.06 ± 0.04 mm for row 5, giving a mean total lengthening of 0.33 ± 0.20 mm. Linear regression revealed that MCLs were repeatably lengthened by 0.07 mm per row when punctured using the instrument. CONCLUSIONS: MCLs showed linear lengthening in human cadavers for subsequent use of the instrument. Our instrument shows promising results for repeatable ligament lengthening.

16.
Acta Radiol ; 53(10): 1081-7, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23081954

RESUMEN

BACKGROUND: Surgical treatment is the only option for long-term survival in patients with colorectal liver metastasis (CRLM). Contrast-enhanced CT and MRI are usually used for preoperative liver imaging. The initial surgical strategy for liver resection is based upon these findings. Further optimization of the surgical strategy by contrast-enhanced intraoperative ultrasound (CE-IOUS) might further improve the surgical outcome. PURPOSE: To evaluate the current impact of CE-IOUS with SonoVue(®) on the initial surgical strategy for CRLM. MATERIAL AND METHODS: Eighty-six consecutive patients undergoing open liver resection for CRLM were evaluated retrospectively over a 2.5-year period. The patients underwent 97 operations. Preoperative staging was performed with contrast-enhanced CT in all patients and MRI was available in 66 of 86 patients. CE-IOUS was performed in all patients according to a standardized examination technique. Curved array and linear transducers were used. CRLM were identified in venous phase as hypovascular lesions. CE-IOUS findings were compared with preoperative staging. RESULTS: Combined CT/MRI identified preoperatively 328 CRLM (mean 3.4, range 0-14). Seventy-two additional lesions (18%) were identified in 38 patients during the operation. Intraoperatively 41 additional CRLM in 20 patients were identified by inspection, palpation, and CE-IOUS (10%), and another 31 CRLM in 17 patients were identified by CE-IOUS alone (8%). All additional CRLM detected by CE-IOUS were confirmed by histology if resection was performed. CE-IOUS changed planned operation strategy in 29.9% of operations. A larger resection was necessary in 13.4% of the cases, reduced liver resection was found sufficient in 11.3%, and 5.2% were found inoperable. For patients diagnosed preoperatively with solitary lesions CE-IOUS changed operation strategy in 19% and radical tumor resection would have failed in 4.8% without CE-IOUS. CONCLUSION: CE-IOUS is essential to ensure optimal and complete tumor resection both in patient with solitary CRLM and multiple metastases.


Asunto(s)
Neoplasias Colorrectales/patología , Medios de Contraste , Cuidados Intraoperatorios/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Hígado/cirugía , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fosfolípidos , Estudios Retrospectivos , Hexafluoruro de Azufre
18.
Eur J Radiol Open ; 9: 100418, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35391822

RESUMEN

Background: A novel deep learning image reconstruction (DLIR) algorithm for CT has recently been clinically approved. Purpose: To assess low-contrast detectability and dose reduction potential for CT images reconstructed with the DLIR algorithm and compare with filtered back projection (FBP) and hybrid iterative reconstruction (IR). Material and methods: A customized upper-abdomen phantom containing four cylindrical liver inserts with low-contrast lesions was scanned at CT dose indexes of 5, 10, 15, 20 and 25 mGy. Images were reconstructed with FBP, 50% hybrid IR (IR50), and DLIR of low strength (DLL), medium strength (DLM) and high strength (DLH). Detectability was assessed by 20 independent readers using a two-alternative forced choice approach. Dose reduction potential was estimated separately for each strength of DLIR using a fitted model, with the detectability performance of FBP and IR50 as reference. Results: For the investigated dose levels of 5 and 10 mGy, DLM improved detectability compared to FBP by 5.8 and 6.9 percentage points (p.p.), and DLH improved detectability by 9.6 and 12.3 p.p., respectively (all p < .007). With IR50 as reference, DLH improved detectability by 5.2 and 9.8 p.p. for the 5 and 10 mGy dose level, respectively (p < .03). With respect to this low-contrast detectability task, average dose reduction potential relative to FBP was estimated to 39% for DLM and 55% for DLH. Relative to IR50, average dose reduction potential was estimated to 21% for DLM and 42% for DLH. Conclusions: Low-contrast detectability performance is improved when applying a DLIR algorithm, with potential for radiation dose reduction.

19.
Eur J Radiol Open ; 8: 100341, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33898653

RESUMEN

BACKGROUND: Following an episode of acute diverticulitis, surgical guidelines commonly advise routine colonic follow-up to rule out underlying malignancy. However, as a CT of the abdomen is frequently performed during clinical work-up, the routine need for colonic follow-up has become debated. PURPOSE: To evaluate the need for routine CT colonography after an episode of CT-verified uncomplicated sigmoid diverticulitis to rule out underlying colorectal malignancy. MATERIAL AND METHODS: This study retrospectively evaluated 312 patients routinely referred to colonic evaluation by CT colonography following an episode of acute diverticulitis. Patients were excluded if lacking diagnostic CT of the abdomen at time of diagnosis, if presenting with atypical colonic involvement, or if CT findings were suggestive of complicated disease (e.g., abscess or perforation). CT colonography exams were routinely reviewed by experienced abdominal radiology consultants on the day of the procedure. If significant polyps were detected, or if colorectal malignancy could not be excluded, patients were referred to same-day optical colonoscopy. For these patients, medical records were reviewed for optical colonoscopy results and histology reports if applicable. RESULTS: Among 223 patients with CT-verified uncomplicated sigmoid diverticulitis, no patients were found to have underlying colorectal malignancy. 27 patients were referred to optical colonoscopy based on CT colonography findings. 18 patients consequently underwent polypectomy, all with either hyperplastic or adenomatous histology. CONCLUSIONS: This study indicates that routine colonic evaluation by CT colonography following an episode of CT-verified uncomplicated sigmoid diverticulitis may be unwarranted, and should arguably be reserved for patients with protracted or atypical clinical course.

20.
Ann Med ; 53(1): 2225-2233, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34806501

RESUMEN

BACKGROUND AND AIMS: Peroral endoscopic myotomy (POEM) is an established therapy for achalasia, but outcome evaluation has often been limited to Eckardt score (ES). The present study was aimed to improve knowledge about outcome evaluation and predictive outcome factors by performing a comprehensive objective evaluation of achalasia patients treated by POEM. METHODS: This single centre prospective study reports outcome data 12 months after POEM in treatment-naive achalasia patients. A predefined follow-up protocol included ES, high resolution manometry, 24-h pH measurement, upper endoscopy and timed barium esophagogram (TBE). Univariate and multivariate regression analyses were performed to analyze association between post-POEM variables and identify predictive factors for objective outcome. RESULTS: Fifty patients were included with a drop-out rate of <5%. ES, lower oesophageal sphincter pressures, TBE heights and maximal oesophageal diameter were all reduced after POEM (p < .001), and 28% (13/47) of the patients had a positive 24-h pH registration. An oesophageal diameter >3 cm after POEM was associated with treatment failure assessed by ES (p = .04) and TBE (p = .03). Advanced achalasia stage (p = .02) and long symptom duration (p = .04) were identified as independent predictive factors for poor outcome assessed by TBE. CONCLUSIONS: The present study confirms that POEM is an efficient therapy for achalasia. The comprehensive objective evaluation after POEM demonstrates that long symptom duration and major changes in oesophageal anatomy at diagnosis imply poor treatment outcome, and a post-POEM dilated oesophagus is associated with treatment failure.Key messagesPeroral endoscopic myotomy (POEM) is established as a safe and effective therapy for achalasia.Timed barium esophagogram offers objective variables that are valuable in treatment response evaluation. Advanced achalasia stage and long symptom duration are predictive factors for poor objective treatment response after POEM.


Asunto(s)
Acalasia del Esófago/cirugía , Esfínter Esofágico Inferior/cirugía , Esofagoscopía/métodos , Miotomía/métodos , Cirugía Endoscópica por Orificios Naturales/métodos , Adulto , Anciano , Bario , Acalasia del Esófago/diagnóstico por imagen , Esfínter Esofágico Inferior/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Cirugía Endoscópica por Orificios Naturales/efectos adversos , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA