Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Pediatr Cardiol ; 34(4): 907-11, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23143349

RESUMEN

Coronary artery anomalies may increase the risk of sudden death. Despite awareness of this association with certain congenital heart anomalies such as tetralogy of Fallot and transposition of the great arteries, it is thought to be an infrequent finding in cases of isolated patent ductus arteriosus (PDA). The authors report their experience with coronary anomalies in PDA patients. This study aimed to estimate the incidence of coronary artery anomalies in patients with PDA. The study reviewed 206 angiograms of PDA patients obtained between 1999 and 2011 to determine the origin of the coronary arteries. In 102 angiograms (49.5 %), the origin of the coronary arteries could be adequately visualized. An anomalous origin of coronary arteries was detected in 11 of the 102 patients (10.8 %). Seven of these patients had a single common coronary artery origin (6.8 %). One patient had an aberrant origin of the left coronary artery from the noncoronary sinus, and three patients had an aberrant origin of the right coronary artery: two from the left coronary sinus and one from the noncoronary sinus. These findings suggest that the incidence of coronary artery anomalies in association with an isolated PDA may be considerably higher than expected and previously reported. In view of the increased risk for sudden death with coronary anomalies, a reasonable approach is to determine the coronary artery origin and pathway after the diagnosis of an isolated PDA.


Asunto(s)
Anomalías de los Vasos Coronarios/complicaciones , Conducto Arterioso Permeable/complicaciones , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Distribución de Chi-Cuadrado , Niño , Preescolar , Angiografía Coronaria , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/epidemiología , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/epidemiología , Femenino , Humanos , Incidencia , Lactante , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Estadísticas no Paramétricas
2.
Front Cardiovasc Med ; 8: 817299, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35155617

RESUMEN

BACKGROUND: Cryoballoon ablation (CBA) for pulmonary vein isolation (PVI) is a standard in atrial fibrillation (AF) ablation but might not be enough in complex atrial arrhythmias (AA). An open three-dimensional wide-band dielectric imaging system (3D-WBDIS) has been introduced to guide CBA. MATERIAL AND METHODS: Pilot study evaluating feasibility and safety of 3D-WBDIS in combination with CBA and optional radiofrequency ablation (RFA) in patients with complex AA defined as (1) history of persistent AF, (2) additional atrial tachycardia/flutter, or (3) previous left atrial ablation. RESULTS: Prospectively, seventeen patients, 68.9 ± 12.2 years of age, with complex AA were enrolled. In 70 pulmonary veins (PV), balloon positioning maneuvers (n = 129) were guided additionally by the occlusion tool (1.84/PV). Compared to angiography, its sensitivity and specificity was 94.5, and 85%, respectively. CBA-PVI was achieved in 100% of PVs including variants. In 68 maps, the median number of mapping points was 251.0 (interquartile range (IQR) 298.0) with a median map volume of 52.8 (IQR 83.9) mL. Following CBA, six additional arrhythmias (two right and two left atrial flutter, one left atrial appendage tachycardia, and one atrioventricular nodal reentry tachycardia) were identified and successfully ablated by means of RFA in five patients (29.4%). Left atrial and fluoroscopy times were 88 (IQR 40) and 20 (IQR 10) minutes, respectively. Dose area product was 1,100 (IQR 1252) cGyxcm2. Freedom from AA after 6 months follow-up time and 90 days blanking period was documented in 10/17 (59%) patients, and 8/17 (47%) without a blanking period. No major complication was observed. CONCLUSION: The combined use of CBA with optional RFA guided by a novel 3D-WBDIS is feasible and safe in patients suffering from complex AA. The occlusion tool shows high sensitivity and specificity for assessment of the balloon occlusion. Additional arrhythmias were successfully mapped and ablated. Short-term outcome is promising, and subsequent prospective, larger outcome studies are necessary to confirm our observations.

3.
Heart Rhythm ; 16(12): 1883-1889, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31255845

RESUMEN

BACKGROUND: Catheter navigation and 3-dimensional (3D) cardiac mapping are essential components of minimally invasive electrophysiological procedures. OBJECTIVE: The purpose of this study was to develop a novel 3D mapping system (KODEX - EPD, EPD Solutions, Best, The Netherlands) that measures changing electric field gradients induced on intracardiac electrodes to enable catheter localization and real-time 3D cardiac mapping. METHODS: We first validated the accuracy of the system's measurement and localization capabilities by comparing known and KODEX - EPD-measured distances and locations at 12 anatomical landmarks in both the atria and ventricles of 4 swine. Next, in vivo images of 3D porcine cardiac anatomy generated by KODEX - EPD and widely used CARTO 3 system (Biosense Webster, Inc., Diamond Bar, CA) were compared with gold standard computed tomography images acquired from the same animals. Finally, 3D maps of atrial anatomy were created for 22 patients with paroxysmal atrial fibrillation (Dielectric Unravelling of Radiofrequency ABLation Effectiveness trial). RESULTS: First, the mean error between known and measured distances was 1.08 ± 0.11 mm (P < .01) and the overall standard deviation between known and measured locations in 12 areas of the porcine heart was 0.35 mm (P < .01). Second, an expert comparison of 3D image quality revealed that KODEX - EPD is noninferior to CARTO 3. Third, the system enabled 3D imaging of atrial anatomy in humans, provided real-time images of atrioventricular valves, and detected important anatomical variations in a subset of patients. CONCLUSION: The KODEX - EPD system is a novel 3D mapping system that accurately detects catheter location and can generate high-resolution images without the need for preacquired imaging, specialty catheters, or a point-by-point mapping procedure.


Asunto(s)
Fibrilación Atrial , Mapeo del Potencial de Superficie Corporal , Ablación por Catéter , Cirugía Asistida por Computador , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/instrumentación , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Precisión de la Medición Dimensional , Técnicas Electrofisiológicas Cardíacas/instrumentación , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Atrios Cardíacos/diagnóstico por imagen , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Evaluación de Resultado en la Atención de Salud , Ajuste de Prótesis/instrumentación , Ajuste de Prótesis/métodos , Venas Pulmonares/cirugía , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Porcinos
4.
Harefuah ; 145(9): 654-5, 703, 2006 Sep.
Artículo en Hebreo | MEDLINE | ID: mdl-17078425

RESUMEN

Contemporary catheterization techniques allow effective percutaneous transcatheter treatment of congenital heart defects as an attractive alternative to open heart surgery. This case report describes transcatheter treatment of congenital pulmonary valve stenosis and secundum atrial septal defect which were diagnosed in a 31 year old woman who presented with cyanosis. This illustrates difficulties in the diagnosis of congenital heart disease in adult patients and demonstrates that transcatheter techniques in the treatment of these congenital anomalies are effective.


Asunto(s)
Ablación por Catéter/métodos , Cianosis/etiología , Cardiopatías Congénitas/terapia , Adulto , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Resultado del Tratamiento
5.
J Am Coll Cardiol ; 40(6): 1067-74; discussion 1075-8, 2002 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-12354429

RESUMEN

OBJECTIVE: The purpose of this study was to validate electromechanical viability parameters with combined myocardial perfusion and metabolic imaging and echocardiography. BACKGROUND: The NOGA System is a catheter-based, non-fluoroscopic, three-dimensional endocardial mapping system. This unique technique allows accurate simultaneous assessment of both local electrical activity and regional contractility. METHODS: The results of NOGA, myocardial single-photon emission computed tomography (SPECT), positron emission tomography, and echocardiography in 51 patients with coronary artery disease and a pathologic SPECT study were transcribed in a nine-segment bull's-eye projection and compared. The local shortening of normally contracting segments, as shown by echocardiography, was 9.2 +/- 5.1%, which decreased to 6.6 +/- 5.0% and 4.1 +/- 5.2% in hypokinetic and akinetic segments. The highest unipolar voltage (11.2 +/- 5.0 mV) and local shortening (8.2 +/- 5.0%) characterized normally perfused segments. Fixed perfusion defects with normal or limited 18-fluoro-2-deoxy-D-glucose uptake indicating viability had a significantly higher unipolar voltage than did scar tissue (7.25 +/- 2.7 vs. 5.0 +/- 3.1 mV, p = 0.029). CONCLUSION: Electromechanical parameters sufficiently defined the viability state of the myocardium and showed good concordance with the findings by nuclear perfusion and metabolism imaging and echocardiography. The NOGA technique provides all the relevant information immediately after coronary angiography and enables the physician to proceed with therapy in the same setting.


Asunto(s)
Supervivencia Celular/fisiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Ecocardiografía , Contracción Miocárdica/fisiología , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada de Emisión , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Electromiografía , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
6.
Rambam Maimonides Med J ; 2(3): e0052, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23908810

RESUMEN

Surprisingly, an utterly imaginative "portrait" has become synonymous with Maimonides forever. How and when did this particular portrait become associated with Maimonides? This and many other intriguing questions regarding this portrait are systematically addressed, and its origins, possible inspiration, and hidden objectives are revealed.

9.
Congenit Heart Dis ; 3(1): 47-53, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18373749

RESUMEN

BACKGROUND: Right-to-left interatrial shunts through an atrial septal defect or patent foramen ovale may result from congenital and acquired conditions. Right-to-left shunts may occur with normal pulmonary artery pressure and resistance as in right ventricular outflow tract obstruction leading to hypertrophy and reduced diastolic function, in right ventricle ischemia, myocarditis or cardiomyopathy and in orthodeoxia-platypnea syndrome. METHODS: We have tested the tolerance of trans-catheter closure of right-to-left interatrial shunts in 5 selected patients in whom the morphology and hemodynamics implied that it would be well-tolerated and improve functional capacity. Right-to-left shunt was demonstrated in 5 profoundly cyanotic patients by trans-thoracic and trans-esophageal echocardiography with intravenous injection of agitated saline. The patients were catheterized for hemo-dynamic study and tested for tolerance of transient balloon occlusion of the defects. RESULTS: Diastolic right ventricular dysfunction with elevated end-diastolic pressure was the primary cause of right-to-left shunt. Most shunts occur via atrial septal defects. Patients' ability to tolerate temporary balloon occlusion of the defects predicted a favorable outcome following permanent device occlusion. Cyanosis resolved in all patients following closure of the defects without congestive right heart failure. A marked improvement in functional capacity was observed in 4 patients. One died of preinterventional hypoxic brain damage. CONCLUSION: Transcatheter closure of right-to-left shunts is well-tolerated and a rewarding approach. It should be applied in selected patients following careful morphologic and hemodynamic evaluation. Tolerance of temporary occlusion of the defect is predictive of a favorable procedural outcome.


Asunto(s)
Oclusión con Balón , Cateterismo Cardíaco , Circulación Coronaria , Foramen Oval Permeable/terapia , Defectos del Tabique Interatrial/terapia , Hemodinámica , Hipoxia/etiología , Adulto , Anciano , Cianosis/etiología , Cianosis/fisiopatología , Cianosis/cirugía , Femenino , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/patología , Foramen Oval Permeable/fisiopatología , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/patología , Defectos del Tabique Interatrial/fisiopatología , Humanos , Hipoxia/complicaciones , Hipoxia/patología , Hipoxia/fisiopatología , Hipoxia/cirugía , Recién Nacido , Masculino , Selección de Paciente , Resultado del Tratamiento , Presión Ventricular
10.
J Invasive Cardiol ; 19(1): 16-8, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17297179

RESUMEN

We evaluate the yield and safety of coronary angiography (CA) in adult patients who underwent cardiac catheterization for percutaneous transcatheter closure of secundum atrial septal defect (ASD) or patent foramen ovale (PFO). Out of 268 patients, 180 were adults; 82 were adults with ASD and 98 were adults with PFO. CA was performed in 23 patients who were suspected for coronary artery disease. Of these patients, 5 (21.7%) had coronary angiographic findings that altered the planned treatment strategy. No complications associated with coronary angiography were observed. CA should be considered a part of cardiac catheterization in selected patients referred for transcatheter closure of secundum ASD or PFO.


Asunto(s)
Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia , Adolescente , Adulto , Niño , Estudios de Evaluación como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Sensibilidad y Especificidad , Resultado del Tratamiento
11.
Heart Fail Rev ; 8(3): 237-45, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12878832

RESUMEN

Recent experimental studies based on innovative hypothesis utilizing cell therapy for the damaged myocardium are recently becoming increasingly promising. The naturally occurring myocardial reparative process is apparently complex and relatively inefficient. It consists of up-regulation of progenitor cell release from the bone marrow after myocardial infarction, homing of these cells to the injured tissue, and differentiation of these progenitor cells into vascular cells and cardiomyocytes within the infarcted tissue. Accordingly, there are two main strategies to regenerate myocardium with autologous stem cells: (1) Extracting stem cells from the bone marrow and injecting these cells into the damaged area, (2) Increasing the efficiency of the naturally occurring reparative process by increasing the mobilization of bone marrow-derived stem cells after myocardial infarction. This review summarizes the growing field of autologous stem cell utilization over the past decade and outlines scientific and clinical hurdles that need to be overcome before this therapy can fully reach its clinical potential.


Asunto(s)
Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/cirugía , Miocardio/patología , Trasplante de Células Madre , Insuficiencia Cardíaca/cirugía , Humanos , Miocardio/citología , Miocitos Cardíacos/fisiología , Miocitos Cardíacos/trasplante , Regeneración , Trasplante de Células Madre/tendencias , Trasplante Autólogo/tendencias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA