Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Biomed Opt ; 26(10)2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34689443

RESUMEN

SIGNIFICANCE: Peripheral pitting edema is a clinician-administered measure for grading edema. Peripheral edema is graded 0, 1 + , 2 + , 3 + , or 4 + , but subjectivity is a major limitation of this technique. A pilot clinical study for short-wave infrared (SWIR) molecular chemical imaging (MCI) effectiveness as an objective, non-contact quantitative peripheral edema measure is underway. AIM: We explore if SWIR MCI can differentiate populations with and without peripheral edema. Further, we evaluate the technology for correctly stratifying subjects with peripheral edema. APPROACH: SWIR MCI of shins from healthy subjects and heart failure (HF) patients was performed. Partial least squares discriminant analysis (PLS-DA) was used to discriminate the two populations. PLS regression (PLSR) was applied to assess the ability of MCI to grade edema. RESULTS: Average spectra from edema exhibited higher water absorption than non-edema spectra. SWIR MCI differentiated healthy volunteers from a population representing all pitting edema grades with 97.1% accuracy (N = 103 shins). Additionally, SWIR MCI correctly classified shin pitting edema levels in patients with 81.6% accuracy. CONCLUSIONS: Our study successfully achieved the two primary endpoints. Application of SWIR MCI to monitor patients while actively receiving HF treatment is necessary to validate SWIR MCI as an HF monitoring technology.


Asunto(s)
Insuficiencia Cardíaca , Imagen Molecular , Análisis Discriminante , Edema/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Análisis de los Mínimos Cuadrados
2.
Environ Sci Technol ; 37(6): 1189-97, 2003 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-12680674

RESUMEN

We describe the development of a novel method for real-time in situ characterization of polycyclic aromatic hydrocarbons (PAHs) in submerged freshwater sediments. Laser-induced fluorescence (LIF) spectroscopy, a mature technique for PAH characterization in terrestrial sediments, was adapted for shipboard use. A cone penetrometer-type apparatus was designed for probe penetration at a constant rate (1 cm/s) to a depth of 3 m. A field-portable LIF system was used for in situ measurements in which the output of a pulsed excimer laser was transmitted by optical fiber to a sapphire window (6.4-mm o.d.) in the probe wall; fluorescent emission was collected by a separate optical fiber for transmission to the spectrometer on deck. Four wavelengths (340, 390, 440, 490 nm) were selected via optical delay lines, and multiple-wavelength waveforms were created. These multiple-wavelength waveforms contain information on the fluorescence frequency, intensity, and emission decay rate. Field testing was conducted at 10 sites in Milwaukee Harbor (total PAH concentrations ranged from approximately 10 to 650 microg/g); conventional sediment core samples were collected concurrently. The core samples were analyzed by EPA methods 3545 (pressurized fluid extraction, PFE) and 8270C (gas chromatography-mass spectrometry, GC-MS) for PAHs. A partial least-squares regression (PLSR) model wasthen created based on laboratory LIF measurements and PFE-GC-MS of the core samples. The PLSR model was applied to the in situ field test data, and 13 of the 16 EPA-regulated PAHs were quantified with a relative error of <30% overall (the remaining three PAHs were found at levels insufficient to quantify). We additionally describe preliminary source apportionment relationships that were revealed by the PLSR model for the in situ LIF measurements.


Asunto(s)
Monitoreo del Ambiente/métodos , Contaminantes Ambientales/análisis , Sedimentos Geológicos/química , Modelos Teóricos , Hidrocarburos Policíclicos Aromáticos/análisis , Cromatografía de Gases y Espectrometría de Masas , Rayos Láser , Sensibilidad y Especificidad , Espectrometría de Fluorescencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA