Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Q J Nucl Med Mol Imaging ; 63(2): 207-215, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28478666

RESUMEN

BACKGROUND: The aim of this study was to evaluate the role of metabolic and morphologic parameters derived from simultaneous hybrid PET/MRI in correlation to clinical criteria for an image-based characterization of musculoskeletal, esophagus and lymph node involvement in systemic sclerosis (SSc). METHODS: Between November 2013 and May 2015, simultaneous whole-body hybrid PET/MRI was performed in 13 prospectively recruited patients with SSc. A mean dose of 241.3 MBq 2-deoxy-2-[18F]fluoro-D-glucose (FDG) was injected. SUVmean and SUVmax values were measured in the spinal bone marrow, spleen, joints, muscles, fasciae, mediastinal lymph nodes and esophagus. MRI abnormalities were scored as 0 (absent), 1 (moderate) and 2 (marked). In addition, organ and skin involvement were graded with clinical sum score (CSS) and modified Rodnan skin score (mRSS), respectively. RESULTS: Results indicate positive correlations between mRSS and fascial FDG-uptake values (fascia summed SUVmax ρ=0.67; fascia summed SUVmean ρ=0.66) that performed better than the MRI sum score (ρ=0.50). Fascial FDG-uptake is also useful in the differentiation between diffuse and limited SSc. Additionally, FDG-PET detected patients with active mediastinal lymphadenopathy and MRI proved to be useful for the delineation of esophagus involvement. CONCLUSIONS: Fascial FDG-uptake has a strong correlation with mRSS and can discriminate between limited and diffuse SSc. These results and the detection of active lymphadenopathy and esophagus involvement can identify patients with advanced scleroderma. Combined PET/MRI therefore provides complementary information on the complex pathophysiology and may integrate several imaging procedures in one.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Esclerodermia Sistémica/metabolismo , Esclerodermia Sistémica/patología , Adulto , Transporte Biológico , Biomarcadores/sangre , Femenino , Fluorodesoxiglucosa F18/metabolismo , Humanos , Masculino , Esclerodermia Sistémica/sangre , Esclerodermia Sistémica/diagnóstico por imagen
2.
Strahlenther Onkol ; 194(8): 719-726, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29564483

RESUMEN

PURPOSE: The purpose of this study was to demonstrate the feasibility of voxel-wise multiparametric characterization of head and neck squamous cell carcinomas (HNSCC) using hybrid multiparametric magnetic resonance imaging and positron emission tomography with [18F]-fluorodesoxyglucose (FDG-PET/MRI) in a radiation treatment planning setup. METHODS: Ten patients with locally advanced HNSCC were examined with a combined FDG-PET/MRI in an irradiation planning setup. The multiparametric imaging protocol consisted of FDG-PET, T2-weighted transverse short tau inversion recovery sequence (STIR) and diffusion-weighted MRI (DWI). Primary tumours were manually segmented and quantitative imaging parameters were extracted. PET standardized uptake values (SUV) and DWI apparent diffusion coefficients (ADC) were correlated on a voxel-wise level. RESULTS: Images acquired in this specialised radiotherapy planning setup achieved good diagnostic quality. Median tumour volume was 4.9 [1.1-42.1] ml. Mean PET SUV and ADC of the primary tumours were 5 ± 2.5 and 1.2 ± 0.3 10-3 mm2/s, respectively. In voxel-wise correlation between ADC values and corresponding FDG SUV of the tumours, a significant negative correlation was observed (r = -0.31 ± 0.27, p < 0.05). CONCLUSION: Multiparametric voxel-wise characterization of HNSCC is feasible using combined PET/MRI in a radiation planning setup. This technique may provide novel insights into tumour biology with regard to radiation therapy in the future.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/radioterapia , Imagen de Difusión por Resonancia Magnética , Neoplasias de Oído, Nariz y Garganta/diagnóstico por imagen , Neoplasias de Oído, Nariz y Garganta/radioterapia , Tomografía de Emisión de Positrones , Planificación de la Radioterapia Asistida por Computador , Anciano , Carcinoma de Células Escamosas/patología , Estudios de Cohortes , Imagen de Difusión por Resonancia Magnética/instrumentación , Diseño de Equipo , Estudios de Factibilidad , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias de Oído, Nariz y Garganta/patología , Proyectos Piloto , Tomografía de Emisión de Positrones/instrumentación , Estudios Prospectivos , Radioterapia Adyuvante , Estadística como Asunto
3.
Eur J Nucl Med Mol Imaging ; 45(1): 95-101, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28831583

RESUMEN

PURPOSE: The aim of the study was to evaluate if 18F-FDG-PET has the potential to detect complete responders to PD1-therapy in patients with unresectable metastasized melanoma two weeks after therapy initiation. METHODS: Between September 2014 and May 2016, ten patients (four females; 65 ± 12 y) received a whole-body 18F-FDG-PET/MRI examination at three time points: Before therapy start (t0, base-line), two weeks (t1, study examination) and three months after treatment initiation (t2, reference standard). Therapy response was assessed with PET response criteria in solid tumors (PERCIST). Time to progression and overall survival (OS) were obtained for all patients. RESULTS: Three patients with partial metabolic response in PET at t1 turned out to have complete response at t2. No tumor relapse was observed in those patients so far (observation period: 265, 511 and 728 days, respectively). At t2, progressive metabolic disease (PMD) was seen in six patients from whom four showed PMD and two showed stable metabolic disease (SMD) at t1. OS in patients with PMD at t2 varied between 148 and 814 days. SMD at both t1 and t2 was seen in one patient, tumor progress was observed after 308 days. CONCLUSION: Our study indicates that whole-body 18F-FDG-PET might be able to reliably identify complete responders to PD1-therapy as early as two weeks after therapy initiation in stage IV melanoma patients. This might help to shorten therapy regimes and avoid unnecessary side effects in the future.


Asunto(s)
Anticuerpos Monoclonales Humanizados/uso terapéutico , Antineoplásicos Inmunológicos/uso terapéutico , Melanoma/diagnóstico por imagen , Tomografía de Emisión de Positrones , Anciano , Femenino , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética , Masculino , Melanoma/tratamiento farmacológico , Persona de Mediana Edad , Imagen Multimodal , Radiofármacos
4.
Eur Radiol ; 28(8): 3372-3383, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29484459

RESUMEN

OBJECTIVES: The aim of this study was to compare the diagnostic performance of simultaneous multislice diffusion-weighted imaging (DWI-SMS) with that of standard DWI (DWI-STD) in whole-body 3-T PET/MRI examination protocols in oncological patients. METHODS: In a phantom study, we evaluated the apparent diffusion coefficients (ADC) from the two techniques. In ten volunteers, we assessed ADC values in different organs. In 20 oncological patients, we evaluated subjective image quality (Likert scale, 5 indicating excellent) and artefacts in different body regions. We also rated the conspicuity and acquired the ADC values of PET-positive tumorous lesions. RESULTS: The scan time for the whole-body DWI-SMS examinations was 40% shorter than the scan time for the DWI-STD examinations (84 s vs. 140 s per table position). The phantom and volunteer studies showed lower ADC values from DWI-SMS in the liver and muscle (psoas muscle 1.4 vs. 1.3). In patients, DWI-SMS provided poorer subjective image quality in the thoracoabdominal region (3.0 vs. 3.8, p = 0.02) and overall more artefacts (138 vs. 105). No significant differences regarding conspicuity and ADC values of lesions were found. CONCLUSIONS: DWI-SMS seems to provide reliable conspicuity and ADC values of tumorous lesions similar to those provided by DWI-STD. Therefore, although providing poorer image quality in certain regions, DWI-SMS can clearly reduce PET/MRI scan times in oncological patients. KEY POINTS: • DWI-SMS can reduce PET/MRI scan times in oncological patients. • DWI-SMS provides reliable ADC values and good lesion conspicuity similar to those provided by DWI-STD. • DWI-SMS may provide poorer image quality in regions with low signal.


Asunto(s)
Neoplasias/patología , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Humanos , Hígado/anatomía & histología , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
5.
Eur Radiol ; 28(4): 1504-1511, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29134353

RESUMEN

OBJECTIVES: To investigate the feasibility of simultaneous multislice-accelerated diffusion-weighted imaging (sms-DWI) of the pancreas with different acceleration factors and its influence on image quality, acquisition time and apparent diffusion coefficients (ADCs) in comparison to conventional sequences. METHODS: DWI of the pancreas was performed at 1.5T in ten healthy volunteers and 20 patients with sms-accelerated echo-planar DWI using two different sms-acceleration factors of 2 and 3 (sms2/3-DWI). These DWI sequences were compared to conventional DWI (c-DWI) in terms of image quality parameters (5-point Likert scale) and ADC measurements. RESULTS: c-DWI and sms2-DWI offered equivalently high overall image quality (4 [1; 5]) with scan time reduction to one-third (c-DWI: 173 s, sms2-DWI: 56 s). Sms3-DWI showed significantly poorer overall image quality (3 [1; 5]; p < 0.0001). ADC values were significantly lower in sms3-DWI compared to c-DWI in the pancreatic body and tail (body: c-DWI 1.4 x 10-3 mm2/s, sms3-DWI 1.0 x 10-3 mm2/s, p = 0.028; tail: c-DWI 1.3 x 10-3 mm2/s and sms3-DWI 1.0 x 10-3 mm2/s, p = 0.014). CONCLUSIONS: Accelerated multislice DWI of the pancreas offers high image quality with a substantial reduction of acquisition time. Lower ADC values in multislice DWI should be considered in diagnostic reading. KEY POINTS: • Simultaneous multislice-accelerated diffusion-weighted imaging (sms-DWI) promises scan time minimisation. • Sms-DWI of the pancreas offers diagnostic image quality in volunteers and patients. • Sms-DWI with an acceleration factor of 2 offers high image quality. • Higher acceleration factors in sms-DWI do not provide sufficient diagnostic image quality. • ADC values may be lower in sms-DWI.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Páncreas/diagnóstico por imagen , Enfermedades Pancreáticas/diagnóstico , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
6.
Radiol Med ; 123(11): 860-870, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29961229

RESUMEN

PURPOSE: To evaluate fast non-enhanced protocols for abdominal PET/MRI in comparison to contrast-enhanced PET/CT with somatostatin receptor (SSR)-specific radiotracers regarding effectiveness of lesion detection in NET patients. METHODS: This was a retrospective analysis of 29 patients (12 male, 57 ± 13 years) who underwent PET/CT and subsequently PET/MRI at the same day. Two readers evaluated independently four PET/MRI setups: (I) PET + T2 Half Fourier Acquisition Single Shot Turbo Spin Echo (T2 HASTE), (II) PET + T2 HASTE + T2-weighted spin-echo sequence (T2 TSE), III) PET + T2 HASTE + Diffusion Weighted Imaging (DWI) and (IV) PET + T2 HASTE + T2 TSE + DWI. A consensus reading of PET/MRI and PET/CT including follow-up examinations served as the reference standard for lesion-based analysis. Lesion sizes were assessed. RESULTS: Setup IV provided comparable overall detection rates as PET/CT in both readers: PET/MRI 91.5%/92.9% versus 89.7% in PET/CT. In liver and bone lesions (mean diameter: 1.9 and 1.5 cm), PET/MRI was equal or superior to PET/CT: 98%/98% versus 85% in PET/CT; 100%/95% versus 100% in PET/CT, but inferior in pancreatic lesions, small bowel lesions and lymph node metastases (mean diameter: 1.3, 0.5 and 1.8 cm). CONCLUSION: A non-enhanced MR protocol comprising T2 HASTE, T2 TSE and DWI for SSR-PET/MRI seems to provide comparable effectiveness in lesions detection as multiphase contrast-enhanced PET/CT. It might, therefore, serve as valid alternative, e.g., for follow-up examinations in patients with unresectable NET and kidney failure.


Asunto(s)
Imagen por Resonancia Magnética , Imagen Multimodal , Tumores Neuroendocrinos/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Abdomen , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Retrospectivos
7.
Magn Reson Med ; 78(2): 632-644, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27667730

RESUMEN

PURPOSE: To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS: We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A partial Fourier-like constraint compacts the sampling space to one half of k-space. The central k-space line is periodically acquired to allow an extraction of a self-navigated respiration signal used to populate a k-space of multiple breathing positions. The randomness of the acquisition (induced by periodic breathing pattern) yields a subsampled k-space that is reconstructed using compressed sensing. Local image evaluations (coefficient of variation and slope steepness through organs) reveal information about motion resolvability. Image quality is inspected by a blinded reading. Sequence and reconstruction method are made publicly available. RESULTS: The method is able to capture and reconstruct 4D images with high image quality and motion resolution within a short scan time of less than 2 min. These findings are supported by restricted-isometry-property analysis, local image evaluation, and blinded reading. CONCLUSION: The proposed method provides a clinical feasible setup to capture periodic respiratory motion with a fast acquisition protocol and can be extended by further surrogate signals to capture additional periodic motions. Retrospective parametrization allows for flexible tuning toward the targeted applications. Magn Reson Med 78:632-644, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Movimiento/fisiología , Torso/diagnóstico por imagen , Algoritmos , Humanos , Respiración , Estudios Retrospectivos
8.
Eur J Nucl Med Mol Imaging ; 43(13): 2283-2289, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27565153

RESUMEN

PURPOSE: To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined 18F-FDG-PET/MRI in pediatric oncology. METHODS: 30 18F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUVmean and SUVmax) as well as SUV variation (SUVvar) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal 18F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. RESULTS: Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUVmean and SUVmax were below 5 % at 18F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg 18F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg 18F-FDG or higher. Administration of 18F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. CONCLUSION: Significant reduction in administered 18F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of 18F-FDG or other tracers for specific clinical questions have to be further established in selected patient populations.


Asunto(s)
Fluorodesoxiglucosa F18/administración & dosificación , Imagen por Resonancia Magnética/métodos , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Exposición a la Radiación/prevención & control , Protección Radiológica/métodos , Adolescente , Niño , Preescolar , Relación Dosis-Respuesta a Droga , Estudios de Factibilidad , Femenino , Humanos , Lactante , Masculino , Imagen Multimodal/métodos , Dosis de Radiación , Exposición a la Radiación/análisis , Radiofármacos/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Imagen de Cuerpo Entero/métodos , Recuento Corporal Total/métodos
9.
J Magn Reson Imaging ; 43(4): 824-32, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26348708

RESUMEN

PURPOSE: To introduce and evaluate a method for signal-to-noise ratio (SNR) improvement and T2 shine-through effect reduction in diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHODS: The proposed method uses quantitative information given by the voxel apparent diffusion coefficient (ADC) to derive voxelwise-computed DWI (vcDWI). Behavior of signal intensity variations was simulated and correlated with measurements using a dedicated phantom for DWI allowing for independent adjustment of T2 -relaxivity and diffusivity. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured and compared to the method of computed DWI (cDWI). Image signal was correlated with ADCs to appreciate the extent of T2 shine-through effects. Additionally, the proposed method was retrospectively applied to whole-body DWI data of 20 patients with metastatic malignancies. vcDWI was compared to cDWI and measured DWI with respect to image quality, lesion detectability, and lesion diffusivity assessment. RESULTS: Theoretically predicted signal intensity variations showed a high correlation with measured phantom data (r > 0.96). The proposed method yielded lower background signal intensity variation and higher contrast (+144%) and CNR (+358%) for diffusion-restricted phantom compartments than cDWI. Signal intensities of vcDWI showed an increased inverse correlation with phantom ADC values compared to cDWI (r = -0.86 vs. r = -0.73). Application to patient data showed higher image quality (P < 0.001) and lesion detectability (P = 0.011) using vcDWI compared to cDWI, and higher confidence for the correct identification of diffusion-restricted lesions compared to measured DWI (80/80 vs. 60/81; P = 0.013). CONCLUSION: vcDWI is a promising approach for the reduction of T2 shine-through effects and improvement of SNR and CNR in DWI. The clinical significance of these improvements, especially regarding lesion detection, needs to be evaluated in larger prospective clinical studies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias/diagnóstico por imagen , Relación Señal-Ruido , Adolescente , Adulto , Anciano , Algoritmos , Medios de Contraste/química , Imagen Eco-Planar , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Fantasmas de Imagen , Estudios Retrospectivos , Adulto Joven
10.
J Magn Reson Imaging ; 44(4): 865-79, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26919580

RESUMEN

PURPOSE: To systematically evaluate image characteristics of simultaneous-multislice (SMS)-accelerated diffusion-weighted imaging (DWI) of the liver using different breathing schemes in comparison to standard sequences. MATERIALS AND METHODS: DWI of the liver was performed in 10 healthy volunteers and 12 patients at 1.5T using an SMS-accelerated echo planar imaging sequence performed with respiratory-triggering and free breathing (SMS-RT, SMS-FB). Standard DWI sequences served as reference (STD-RT, STD-FB). Reduction of scan time by SMS-acceleration was measured. Image characteristics of SMS-DWI and STD-DWI with both breathing schemes were analyzed quantitatively (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR]) and qualitatively (5-point Likert scale, 5 = excellent). Qualitative and quantitative parameters were compared using Friedman test and Dunn-Bonferroni post-hoc method with P-values < 0.05 considered statistically significant. RESULTS: SMS-DWI provided diagnostic image quality in volunteers and patients both with RT and FB with a reduction of scan time of 70% (0:56 vs. 3:20 min in FB). Overall image quality did not significantly differ between FB and RT acquisition in both STD and SMS sequences (median STD-RT 5.0, STD-FB 4.5, SMS-RT: 4.75; SMS-FB: 4.5; P = 0.294). SNR in the right hepatic lobe was comparable between the four tested sequences. ADC values were significantly lower in SMS-DWI compared to STD-DWI irrespective of the breathing scheme (1.2 ± 0.2 × 10(-3) mm(2) /s vs. 1.0 ± 0.2 × 10(-3) mm(2) /s; P < 0.001). CONCLUSION: SMS-acceleration provides considerable scan time reduction for hepatic DWI with equivalent image quality compared to the STD technique both using RT and FB. Discrepancies in ADC between STD-DWI and SMS-DWI need to be considered when transferring the SMS technique to clinical routine reading. J. MAGN. RESON. IMAGING 2016;44:865-879.


Asunto(s)
Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Hígado/diagnóstico por imagen , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Algoritmos , Contencion de la Respiración , Femenino , Humanos , Hígado/anatomía & histología , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados , Mecánica Respiratoria , Sensibilidad y Especificidad
11.
MAGMA ; 29(5): 739-49, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27038935

RESUMEN

OBJECTIVE: To evaluate simultaneous multislice (sms) accelerated diffusion-weighted imaging (DWI) of the liver in comparison to conventional sequences. MATERIALS AND METHODS: Ten volunteers underwent DWI of the liver at 1.5 T. Four different sms-accelerated sequences with monopolar and bipolar gradient preparation (MP, BP) and acceleration factors 2 and 3 (sms2-DWI, sms3-DWI) were compared to conventional DWI (c-DWI). Image quality criteria rated on a 5-point Likert scale (5 = excellent), image quality sum scores (maximum 120), and ADC were compared using Friedman test and Dunn-Bonferroni post hoc test. Bland-Altman plots were calculated for ADC comparison. p values <0.05 were considered significant. RESULTS: Sms2-DWI offered scan time minimization of 67 % without significant difference in image quality (sum score: sms2-DWI MP/BP: 97 ± 8/92 ± 9; c-DWI MP/BP: 99 ± 8/97 ± 8). Sms3-DWI offered slight additional scan time minimization with significantly inferior image quality (sum score: sms3-DWI MP/BP: 75 ± 14/69 ± 14; p < 0.001). MP preparation provided slightly higher image quality in sms-DWI without statistical significance. ADC in sms-DWI were significantly lower (sms2-DWI MP 1.01 × 10(-3) mm(2)/s; c-DWI MP 1.20 × 10(-3) mm(2)/s; p < 0.001). CONCLUSION: Sms2-DWI provides considerable scan time minimization without significant shortcomings in image quality. Sms3-DWI provides significantly inferior image quality without further scan time minimization. Potentially lower ADC in sms-DWI should be considered in clinical routine.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Adulto , Femenino , Voluntarios Sanos , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Factores de Tiempo
12.
Hell J Nucl Med ; 19(1): 15-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26929936

RESUMEN

OBJECTIVE: Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. METHODS: (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. RESULTS: (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose-reduced datasets based on clinical (18)F-FDG PET data demonstrated the clinical applicability of the proposed data. CONCLUSION: Simulation of PET tracer dose reduction is possible with retrospective undersampling of list-mode data. Resulting simulated low-dose images have equivalent characteristics with PET images actually measured at lower doses and can be used to derive optimal tracer dose regimes.


Asunto(s)
Algoritmos , Radioisótopos de Flúor/farmacocinética , Interpretación de Imagen Asistida por Computador/métodos , Modelos Biológicos , Tomografía de Emisión de Positrones/métodos , Protección Radiológica/métodos , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Modelos Estadísticos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Dosis de Radiación , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tamaño de la Muestra , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
13.
NMR Biomed ; 28(7): 914-22, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26014883

RESUMEN

Multiparametric medical imaging data can be large and are often complex. Machine learning algorithms can assist in image interpretation when reliable training data exist. In most cases, however, knowledge about ground truth (e.g. histology) and thus training data is limited, which makes application of machine learning algorithms difficult. The purpose of this study was to design and implement a learning algorithm for classification of multidimensional medical imaging data that is robust and accurate even with limited prior knowledge and that allows for generalization and application to unseen data. Local prostate cancer was chosen as a model for application and validation. 16 patients underwent combined simultaneous [(11) C]-choline positron emission tomography (PET)/MRI. The following imaging parameters were acquired: T2 signal intensities, apparent diffusion coefficients, parameters Ktrans and Kep from dynamic contrast-enhanced MRI, and PET standardized uptake values (SUVs). A spatially constrained fuzzy c-means algorithm (sFCM) was applied to the single datasets and the resulting labeled data were used for training of a support vector machine (SVM) classifier. Accuracy and false positive and false negative rates of the proposed algorithm were determined in comparison with manual tumor delineation. For five of the 16 patients rates were also determined in comparison with the histopathological standard of reference. The combined sFCM/SVM algorithm proposed in this study revealed reliable classification results consistent with the histopathological reference standard and comparable to those of manual tumor delineation. sFCM/SVM generally performed better than unsupervised sFCM alone. We observed an improvement in accuracy with increasing number of imaging parameters used for clustering and SVM training. In particular, including PET SUVs as an additional parameter markedly improved classification results. A variety of applications are conceivable, especially for imaging of tissues without easily available histopathological correlation.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Aprendizaje Automático , Imagen por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico , Anciano , Anciano de 80 o más Años , Algoritmos , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Eur J Nucl Med Mol Imaging ; 42(4): 634-43, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25573632

RESUMEN

Non-small-cell lung cancer is the most common type of lung cancer and one of the leading causes of cancer-related death worldwide. For this reason, advances in diagnosis and treatment are urgently needed. With the introduction of new, highly innovative hybrid imaging technologies such as PET/CT, staging and therapy response monitoring in lung cancer patients have substantially evolved. In this review, we discuss the role of FDG PET/CT in the management of lung cancer patients and the importance of new emerging imaging technologies and radiotracer developments on the path to personalized medicine.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Imagen Multimodal , Tomografía de Emisión de Positrones , Radiofármacos , Animales , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Humanos , Neoplasias Pulmonares/diagnóstico , Imagen por Resonancia Magnética , Radiofármacos/farmacocinética , Tomografía Computarizada por Rayos X
15.
J Magn Reson Imaging ; 42(4): 1048-56, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25683203

RESUMEN

BACKGROUND: To analyze the regional composition of bone marrow (BM) in correlation with metabolic activity and diffusivity using simultaneous positron emission tomography (PET)/MRI. METHODS: Retrospective analysis of 18F-FDG-PET/MR scans of 110 patients was performed. A three-dimensional gradient-echo sequence with Dixon-based fat-water separation was used for fat quantification. Dixon images, diffusion-weighted images (DWI) and 18F-FDG-PET were co-registered. Mean values of fat fraction (FF), standardized uptake value (SUV), and apparent diffusion coefficient (ADC) of BM were measured in different anatomical regions. Correlation of FF, SUV, and ADC and association of BM fat content and metabolic activity with anthropometric data was analyzed (Pearson). BM fat content and metabolic activity was compared in patients with and without chemotherapy (t-test). RESULTS: Regional differences in BM were found with highest fat content (93 ± 8%) and lowest ADC (0.22 ± 0.18 × 10(-3) mm(2) /s) in the peripheral skeleton and highest SUV in the spine (1.77 ± 0.6). There was a significant inverse correlation between FF and SUV (r = -0.73; P < 0.0001) and a significant inverse correlation between FF and ADC (r = -0.62; P < 0.0001). In patients with chemotherapy, a tendency to higher fat content and lower metabolic activity was observed in the proximal skeleton, although no statistical significance was reached. CONCLUSION: BM shows distinct regional variations in FF, SUV, and ADC. The inverse correlation of FF and SUV in BM suggests that BM adipose tissue does not have a comparable high metabolic activity as brown adipose tissue.


Asunto(s)
Tejido Adiposo/metabolismo , Médula Ósea/metabolismo , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Neoplasias/metabolismo , Tomografía de Emisión de Positrones/métodos , Tejido Adiposo/patología , Adiposidad , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antropometría/métodos , Peso Corporal , Médula Ósea/patología , Niño , Preescolar , Medios de Contraste/farmacocinética , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Neoplasias/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
16.
Acta Radiol ; 56(8): 908-16, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25182804

RESUMEN

BACKGROUND: Previous studies have shown a benefit of magnetic resonance (MR)-diffusion-weighted imaging (DWI) for follow-up after liver radiofrequency (RF) ablation. However, no data are available concerning acute changes of DWI characteristics immediately after RF ablation. PURPOSE: To analyze and compare the MR-diffusion characteristics of pre-interventional hepatic malignancies and the ablation zone during successful MR-guided RF ablation. MATERIAL AND METHODS: This retrospective study was conducted in accordance with the guidelines of the local institutional review board. Forty-seven patients with 29 HCC (24 patients) and 30 hepatic metastases (23 patients) underwent MR-guided radiofrequency ablation including DWI before and immediately after ablation (b = 0, 400, 800 s/mm(2)). Two reviewers (A and B) analyzed DWI with focus on detectability of the tumor before ablation and characteristics of the coagulative area after treatment. Mean apparent diffusion coefficient (ADC) was compared between liver, untreated tumor, and hyperintense areas in post-ablative DWI (b = 800 s/mm(2)) with the paired Student's t-test. RESULTS: Pre-ablative: the reviewers classified 19/29 (A) and 23/29 (B) HCC and 25/30 (A and B) metastases as detectable in DWI. Post-ablative: a hyperintense rim surrounding the ablation zone was observed in 28/29 treated HCC and 30/30 treated metastases (A and B). A homogenous hypointense central ablation zone was found in 18/29 (A) and 20/29 (B) treated HCC and 17/30 (A & B) treated metastases in DWI. ADC of the rim was significantly lower than ADC of the liver (P < 0.001). CONCLUSION: DWI enables visualization of the target tumor in MR-guided liver radiofrequency ablation in most cases. A common post-ablative DWI finding is a hyperintense rim with decreased ADC surrounding the ablation zone.


Asunto(s)
Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Cuidados Posoperatorios/métodos , Cuidados Preoperatorios/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
17.
Radiology ; 273(1): 220-31, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24877983

RESUMEN

PURPOSE: To compare positron emission tomography (PET)/magnetic resonance (MR) imaging and PET/computed tomography (CT) for lesion detection and interpretation, quantification of fluorine 18 ((18)F) fluorodeoxyglucose (FDG) uptake, and accuracy of MR-based PET attenuation correction in pediatric patients with solid tumors. Materials and Methods This prospective study had local ethics committee and German Federal Institute for Drugs and Medical Devices approval. Written informed consent was obtained from all patients and legal guardians. Twenty whole-body (18)F-FDG PET/CT and (18)F-FDG PET/MR examinations were performed in 18 pediatric patients (median age, 14 years; range, 11-17 years). (18)F-FDG PET/CT and (18)F-FDG PET/MR data were acquired sequentially on the same day for all patients. PET standardized uptake values (SUVs) were quantified with volume of interest measurements in lesions and healthy tissues. MR-based PET attenuation correction was compared with CT-derived attenuation maps (µ-maps). Lesion detection was assessed with separate reading of PET/CT and PET/MR data. Estimates of radiation dose were derived from the applied doses of (18)F-FDG and CT protocol parameters. Descriptive statistical analyses were performed to report correlation coefficients and relative deviations for comparison of SUVs, rates of lesion detection, and percentage reductions in radiation dose. RESULTS: PET SUVs showed strong correlations between PET of PET/CT (PETCT) and PET of PET/MR (PETMR) (r > 0.85 for most tissues). Apart from drawbacks of MR-based PET attenuation correction in osseous structures and lungs, similar SUVs were found on PET images corrected with CT-based µ-maps (13.1% deviation of SUVs for bone marrow and <5% deviation for other tissues). Lesion detection rate with PET/MR imaging was equivalent to that with PET/CT (61 areas of focal uptake on PETMR images vs 62 areas on PETCT images). Advantages of PET/MR were observed especially in soft-tissue regions. Furthermore, PET/MR offered significant dose reduction (73%) compared with PET/CT. CONCLUSION: Pediatric oncologic PET/MR is technically feasible, showing satisfactory performance for PET quantification with SUVs similar to those of PET/CT. Compared with PET/CT, PET/MR demonstrates equivalent lesion detection rates while offering markedly reduced radiation exposure. Thus, PET/MR is a promising modality for the clinical work-up of pediatric malignancies. Online supplemental material is available for this article.


Asunto(s)
Imagen por Resonancia Magnética , Imagen Multimodal , Neoplasias/diagnóstico , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Imagen de Cuerpo Entero , Adolescente , Niño , Medios de Contraste , Femenino , Humanos , Masculino , Neoplasias/diagnóstico por imagen , Estudios Prospectivos , Dosis de Radiación
18.
Magn Reson Med ; 72(2): 459-63, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24123316

RESUMEN

PURPOSE: To design a phantom for diffusion-weighted imaging (DWI) with defined apparent diffusion coefficients (ADC) and T2 relaxation times. METHODS: Varying concentrations of polyethylene glycol (PEG) were used for the adjustment of diffusivity. T2 relaxation times were tuned by adding of the MR contrast agent gadobutrol. Relaxation times and apparent diffusion coefficients were quantified using a multiecho spin echo sequence and an echo planar imaging (EPI) DWI sequence, respectively, on a 3T clinical scanner. RESULTS: Increasing concentrations of PEG led to a marked impairment of diffusivity accompanied by only moderate changes of T2 relaxation times. Adding gadobutrol to the PEG solutions allowed for adjustment of transverse relaxation times to predefined values. Thus, a broad range of defined ADC values and T2 relaxation times could be accurately achieved in the final phantom. CONCLUSION: The proposed phantom allows for standardized in vitro studies of DWI methods and protocols. The obtained MR image contrasts are similar to a variety of biological tissues, which can contribute to optimization of imaging techniques with respect to specific clinical questions. Due to the simplicity of design and the accessibility of the contained compounds, this phantom may also serve as a tool for standardization and calibration.


Asunto(s)
Biomimética/instrumentación , Imagen de Difusión por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Magn Reson Med ; 71(1): 294-301, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23400875

RESUMEN

PURPOSE: To improve the visualization of fibrous tissues as tendons, ligaments and fibrocartilage structures as menisci by positive contrast using a new 3D Double Echo Steady State (DESS) sequence. METHODS: The proposed 3D DESS sequence works with separate acquisition of a first echo with an echo time (TE1 ) of 1.2 ms followed by a more heavily T2 -weighted second echo recorded at time TE2 . Subtraction of images from both echoes leads to positive signal from fibrous tissues, whereas in other tissues as musculature and fat the subtraction signal nearly vanishes due to almost similar signal strength in both echoes. Systematic measurements in healthy volunteers with different sets of pulse repetition time (TR), TE1 , readout bandwidth and flip angle were performed to determine optimal sequence parameters. RESULTS: The presented 3D sequence with Cartesian readout requires relatively short measuring time, provides reasonable signal-to-noise ratio and can be easily implemented in protocols for clinical musculoskeletal MR imaging. Degenerative changes or tears of tendons, ligaments and fibrocartilage are known to cause increased water content and therefore prolongation of transverse relaxation times, which leads to reduced signal intensities in the "subtraction images." CONCLUSION: Positive contrast of fibrous tissue as demonstrated by the proposed sub-DESS approach provides improved conspicuity and allows for three-dimensional reconstruction especially of structures with curved geometry.


Asunto(s)
Articulación de la Rodilla/anatomía & histología , Ligamentos/anatomía & histología , Imagen por Resonancia Magnética/métodos , Meniscos Tibiales/anatomía & histología , Técnica de Sustracción , Tendones/anatomía & histología , Algoritmos , Medios de Contraste , Voluntarios Sanos , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Magn Reson Imaging ; 40(5): 1121-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24923481

RESUMEN

PURPOSE: To characterize peritoneal carcinomatosis (PC) of different histologically proven primary tumors based on diffusion-weighted imaging (DWI) and (18) F-FDG positron emission tomography (PET). MATERIALS AND METHODS: Forty-one patients underwent simultaneous MR/PET after clinically indicated (18) F-FDG-PET/CT. For all patients, histology of the primary tumor was obtained. MR protocol comprised anatomical imaging and axial DWI. Apparent diffusion coefficient (ADC) maps and FDG-PET were co-registered for evaluation of ADC and standard uptake value (SUV) of peritoneal lesions. Both lesion- and patient-based analysis was performed. Up to four peritoneal lesions were evaluated per patient. Mean and maximum standard uptake value (SUVmean , SUVmax ), mean and minimum ADC (ADCmean , ADCmin ) of each lesion were assessed. Spearman rank correlation (rs ) of ADC and SUV were calculated. SUV and ADC of ovarian and colorectal cancer lesions were compared using Wilcoxon test. RESULTS: Measurable lesions (n = 52) were found in 20 of 41 PC patients. Moderate, but significant correlation existed between ADC and SUV in the lesion-based as well as the patient-based analysis (lesion-based: SUVmean versus ADCmean rs = -0.58; SUVmax versus ADCmin rs = -0.56, all P < 0.0001; patient-based: SUVmean versus ADCmean rs = -0.64, P = 0.002; SUVmax versus ADCmin rs = -0.60, P = 0.005). ADC and SUV differed significantly between ovarian and colorectal cancer lesions (ADCmin : P < 0.0001; ADCmean : P < 0.0001; SUVmax : P = 0.002; SUVmean : P = 0.005). Overall, mucinous tumor entities showed a tendency to higher ADC and lower SUV. CONCLUSION: PC lesions showed significant differences in glucose uptake and diffusion characteristics depending on primary tumor histology. These differences should be considered when interpreting FDG-PET and DWI in PC patients.


Asunto(s)
Carcinoma/diagnóstico , Neoplasias Colorrectales/diagnóstico , Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Neoplasias Ováricas/diagnóstico , Neoplasias Peritoneales/diagnóstico , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA