RESUMEN
PURPOSE OF REVIEW: In the ever-evolving field of medical imaging, this review highlights significant advancements in preoperative and postoperative imaging for Tetralogy of Fallot (TOF) and double outlet right ventricle (DORV) over the past 18âmonths. RECENT FINDINGS: This review showcases innovations in echocardiography such as 3D speckle tracking echocardiography (3DSTE) for assessing right ventricle-pulmonary artery coupling (RVPAC) and Doppler velocity reconstruction (DoVeR) for intracardiac flow fields evaluation. Furthermore, advances in assessment of cardiovascular anatomy using computed tomography (CT) improve the integration of imaging in ablation procedures. Additionally, the inclusion of cardiac magnetic resonance (CMR) parameters as risk score predictors for morbidity, and mortality and for timing of pulmonary valve replacement (PVR) indicates its significance in clinical management. The utilization of 4D flow techniques for postoperative hemodynamic assessment promises new insights into pressure mapping. Lastly, emerging technologies such as 3D printing and 3D virtual reality are expected to improve image quality and surgical confidence in preoperative planning. SUMMARY: Developments in multimodality imaging in TOF and DORV are poised to shape the future of clinical practice in this field.
Asunto(s)
Ventrículo Derecho con Doble Salida , Imagen Multimodal , Tetralogía de Fallot , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/diagnóstico por imagen , Humanos , Imagen Multimodal/métodos , Ventrículo Derecho con Doble Salida/diagnóstico por imagen , Ventrículo Derecho con Doble Salida/cirugía , Tomografía Computarizada por Rayos X/métodosRESUMEN
BACKGROUND: Cardiac MRI feature tracking (FT) allows objective assessment of segmental left ventricular (LV) function following a myocardial infarction (MI), but its utilization in sheep, where interventions can be tested, is lacking. PURPOSE: To apply and validate FT in a sheep model of MI and describe post-MI LV remodeling. STUDY TYPE: Animal model, longitudinal. ANIMAL MODEL: Eighteen lambs (6 months, male, n = 14; female, n = 4; 25.2 ± 4.5 kg). FIELD STRENGTH/SEQUENCE: Two-dimensional balanced steady-state free precession (bSSFP) and 3D inversion recovery fast low angle shot (IR-FLASH) sequences at 3 T. ASSESSMENT: Seven lambs underwent test-retest imaging to assess FT interstudy reproducibility. MI was induced in the remaining 11 by coronary ligation with MRI being undertaken before and 15 days post-MI. Injury size was measured by late gadolinium enhancement (LGE) and LV volumes, LV mass, ejection fraction (LVEF), and wall thickness (LVWT) were measured, with FT measures of global and segmental radial, circumferential, and longitudinal strain. STATISTICAL TESTS: Sampling variability, inter-study, intra and interobserver reproducibility were assessed using Pearson's correlation, Bland-Altman analyses, and intra-class correlation coefficients (ICC). Diagnostic performance of segmental strain to predict LGE was assessed using receiver operating characteristic curve analysis. Significant differences were considered P < 0.05. RESULTS: Inter-study reproducibility of FT was overall good to excellent, with global strain being more reproducible than segmental strain (ICC = 0.89-0.98 vs. 0.77-0.96). MI (4.0 ± 3.7% LV mass) led to LV remodeling, as evident by significantly increased LV volumes and LV mass, and significantly decreased LVWT in injured regions, while LVEF was preserved (54.9 ± 6.9% vs. 55.6 ± 5.7%; P = 0.778). Segmental circumferential strain (CS) correlated most strongly with LGE. Basal and mid- CS increased significantly, while apical CS significantly decreased post-MI. DATA CONCLUSION: FT is reproducible and compensation by hyperkinetic remote myocardium may manifest as overall preserved global LV function. EVIDENCE LEVEL: N/A TECHNICAL EFFICACY: Stage 2.
RESUMEN
Increasing placental perfusion (PP) could improve outcomes of growth-restricted fetuses. One way of increasing PP may be by using phosphodiesterase (PDE)-5 inhibitors, which induce vasodilatation of vascular beds. We used a combination of clinically relevant magnetic resonance imaging (MRI) techniques to characterize the impact that tadalafil infusion has on maternal, placental and fetal circulations. At 116-117 days' gestational age (dGA; term, 150 days), pregnant ewes (n = 6) underwent fetal catheterization surgery. At 120-123 dGA ewes were anaesthetized and MRI scans were performed during three acquisition windows: a basal state and then â¼15-75 min (TAD 1) and â¼75-135 min (TAD 2) post maternal administration (24 mg; intravenous bolus) of tadalafil. Phase contrast MRI and T2 oximetry were used to measure blood flow and oxygen delivery. Placental diffusion and PP were assessed using the Diffusion-Relaxation Combined Imaging for Detailed Placental Evaluation-'DECIDE' technique. Uterine artery (UtA) blood flow when normalized to maternal left ventricular cardiac output (LVCO) was reduced in both TAD periods. DECIDE imaging found no impact of tadalafil on placental diffusivity or fetoplacental blood volume fraction. Maternal-placental blood volume fraction was increased in the TAD 2 period. Fetal D O 2 ${D_{{{\mathrm{O}}_2}}}$ and V Ì O 2 ${\dot V_{{{\mathrm{O}}_2}}}$ were not affected by maternal tadalafil administration. Maternal tadalafil administration did not increase UtA blood flow and thus may not be an effective vasodilator at the level of the UtAs. The increased maternal-placental blood volume fraction may indicate local vasodilatation of the maternal intervillous space, which may have compensated for the reduced proportion of UtA D O 2 ${D_{{{\mathrm{O}}_2}}}$ .
Asunto(s)
Oxígeno , Placenta , Circulación Placentaria , Tadalafilo , Arteria Uterina , Animales , Femenino , Tadalafilo/farmacología , Tadalafilo/administración & dosificación , Embarazo , Ovinos , Arteria Uterina/efectos de los fármacos , Placenta/efectos de los fármacos , Placenta/irrigación sanguínea , Circulación Placentaria/efectos de los fármacos , Oxígeno/sangre , Flujo Sanguíneo Regional/efectos de los fármacos , Inhibidores de Fosfodiesterasa 5/farmacología , Inhibidores de Fosfodiesterasa 5/administración & dosificación , Imagen por Resonancia Magnética , Feto/irrigación sanguínea , Feto/efectos de los fármacosRESUMEN
BACKGROUND: To investigate the ability of a delayed respiratory-navigated, electrocardiographically-gated three-dimensional inversion recovery-prepared flash low angle shot (3D IR FLASH) sequence to evaluate the lower airways in children undergoing routine cardiovascular magnetic resonance (CMR). METHODS: This retrospective study included pediatric patients (0-18 years) who underwent clinical CMR where a delayed 3D IR FLASH sequence was performed between July 2020 and April 2021. The airway image quality and extent of lower airway visibility was graded by two blinded readers using a four-point ordinal scale (0-3). Lower airway anatomical variants and abnormalities were recorded. RESULTS: 180 patients were included with a median age of 11.7 (4.6-15.3) years. 51/180 (28%) were under general anesthesia (GA). Overall, the median grading of airway image quality was 3 (2-3) and extent of lower airway visibility was 3 (3-3). Interrater agreement was almost perfect (κ = 0.867 and κ = 0.956, respectively). Image quality correlated with extent of lower airway visibility (r = 0.62, p < 0.01). Delayed 3D IR FLASH was able to characterize the segmental bronchi in 137/180 (76%) and lobar bronchi in 172/180 (96%) of patients. Lower airway abnormalities were identified in 37/180 (21%) of patients and in 33/129 (26%) with congenital heart disease (CHD). Identified abnormalities included tracheobronchial branching anomalies in 6/180 (3%), abnormal tracheobronchial situs in 6/180 (3%), and extrinsic vascular compression in 25/180 (14%). CONCLUSIONS: Delayed 3D IR FLASH has excellent performance for evaluation of the lower airway anatomy and can simultaneously assess for myocardial late gadolinium enhancement. Lower airway abnormalities are not infrequently seen in children undergoing routine CMR for CHD.
RESUMEN
AIM: To examine whether antenatal diagnosis modifies relationships between neonatal brain volumes and 18-month neurodevelopmental outcomes in children with transposition of the great arteries (TGA). METHOD: In a retrospective cohort of 139 children with TGA (77 antenatally diagnosed), we obtained total brain volumes (TBVs) on pre- (n = 102) and postoperative (n = 112) magnetic resonance imaging. Eighteen-month neurodevelopmental outcomes were assessed using the Bayley Scales of Infant and Toddler Development, Third Edition. Generalized estimating equations with interaction terms were used to determine whether antenatal diagnosis modified associations between TBVs and neurodevelopmental outcomes accounting for postmenstrual age at scan, brain injury, and ventricular septal defect. RESULTS: Infants with postnatal diagnosis had more preoperative hypotension (35% vs 14%, p = 0.004). The interactions between antenatal diagnosis and TBVs were significantly related to cognitive (p = 0.003) outcomes. Specifically, smaller TBVs were associated with lower cognitive scores in infants diagnosed postnatally; this association was attenuated in those diagnosed antenatally. INTERPRETATION: Antenatal diagnosis modifies associations between neonatal brain volume and 18-month cognitive outcome in infants with TGA. These findings suggest that antenatal diagnosis may be neuroprotective, possibly through improved preoperative clinical status. These data highlight the need to improve antenatal diagnosis rates. WHAT THIS PAPER ADDS: Antenatal diagnosis of transposition of the great arteries modified relationships between neonatal brain volume and neurodevelopment. Smaller brain volumes related to poorer cognitive scores with postnatal diagnosis only. There was more preoperative hypotension in the postnatal diagnosis group.
Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Diagnóstico Prenatal , Transposición de los Grandes Vasos , Humanos , Transposición de los Grandes Vasos/diagnóstico por imagen , Femenino , Estudios Retrospectivos , Encéfalo/diagnóstico por imagen , Encéfalo/crecimiento & desarrollo , Encéfalo/patología , Masculino , Lactante , Recién Nacido , Trastornos del Neurodesarrollo/diagnóstico por imagen , Trastornos del Neurodesarrollo/etiología , Trastornos del Neurodesarrollo/diagnóstico , Desarrollo Infantil/fisiología , EmbarazoRESUMEN
OBJECTIVES: We evaluated fetal cardiovascular physiology and mode of cardiac failure in premature miniature piglets on a pumped artificial placenta (AP) circuit. METHODS: Fetal pigs were cannulated via the umbilical vessels and transitioned to an AP circuit composed of a centrifugal pump and neonatal oxygenator and maintained in a fluid-filled biobag. Echocardiographic studies were conducted to measure ventricular function, umbilical blood flow, and fluid status. In utero scans were used as control data. RESULTS: AP fetuses (n = 13; 102±4d gestational age [term 115d]; 616 ± 139 g [g]; survival 46.4 ± 46.8 h) were tachycardic and hypertensive with initially supraphysiologic circuit flows. Increased myocardial wall thickness was observed. Signs of fetal hydrops were present in all piglets. Global longitudinal strain (GLS) measurements increased in the left ventricle (LV) after transition to the circuit. Right ventricle (RV) and LV strain rate decreased early during AP support compared with in utero measurements but recovered toward the end of the experiment. Fetuses supported for >24 h had similar RV GLS to in utero controls and significantly higher GLS compared to piglets surviving only up to 24 h. CONCLUSIONS: Fetuses on a pump-supported AP circuit experienced an increase in afterload, and redistribution of blood flow between the AP and systemic circulations, associated with elevated end-diastolic filling pressures. This resulted in heart failure and hydrops. These preterm fetuses were unable to tolerate the hemodynamic changes associated with connection to the current AP circuit. To better mimic the physiology of the native placenta and preserve normal fetal cardiovascular physiology, further optimization of the circuit will be required.
Asunto(s)
Órganos Artificiales , Ecocardiografía , Placenta , Porcinos Enanos , Animales , Femenino , Porcinos , Embarazo , Placenta/diagnóstico por imagen , Placenta/irrigación sanguínea , Ecocardiografía/métodos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Animales Recién Nacidos , Fenómenos Fisiológicos Cardiovasculares , Hidropesía Fetal/diagnóstico por imagen , Hidropesía Fetal/fisiopatologíaRESUMEN
Babies born with fetal growth restriction (FGR) are at higher risk of developing cardiometabolic diseases across the life course. The reduction in substrate supply to the developing fetus that causes FGR not only alters cardiac growth and structure but may have deleterious effects on metabolism and function. Using a sheep model of placental restriction to induce FGR, we investigated key cardiac metabolic and functional markers that may be altered in FGR. We also employed phase-contrast magnetic resonance imaging MRI to assess left ventricular cardiac output (LVCO) as a measure of cardiac function. We hypothesized that signalling molecules involved in cardiac fatty acid utilisation and contractility would be impaired by FGR and that this would have a negative impact on LVCO in the late gestation fetus. Key glucose (GLUT4 protein) and fatty acid (FATP, CD36 gene expression) substrate transporters were significantly reduced in the hearts of FGR fetuses. We also found reduced mitochondrial numbers as well as abundance of electron transport chain complexes (complexes II and IV). These data suggest that FGR diminishes metabolic and mitochondrial capacity in the fetal heart; however, alterations were not correlated with fetal LVCO. Overall, these data show that FGR alters fetal cardiac metabolism in late gestation. If sustained ex utero, this altered metabolic profile may contribute to poor cardiac outcomes in FGR-born individuals after birth. KEY POINTS: Around the time of birth, substrate utilisation in the fetal heart switches from carbohydrates to fatty acids. However, the effect of fetal growth restriction (FGR) on this switch, and thus the ability of the fetal heart to effectively metabolise fatty acids, is not fully understood. Using a sheep model of early onset FGR, we observed significant downregulation in mRNA expression of fatty acid receptors CD36 and FABP in the fetal heart. FGR fetuses also had significantly lower cardiac mitochondrial abundance than controls. There was a reduction in abundance of complexes II and IV within the electron transport chain of the FGR fetal heart, suggesting altered ATP production. This indicates reduced fatty acid metabolism and mitochondrial function in the heart of the FGR fetus, which may have detrimental long-term implications and contribute to increased risk of cardiovascular disease later in life.
RESUMEN
Late gestational supine positioning reduces maternal cardiac output due to inferior vena caval (IVC) compression, despite increased collateral venous return. However, little is known about the impact of maternal position on oxygen (O2 ) delivery and consumption of the gravid uterus, fetus, placenta and lower limbs. We studied the effects of maternal positioning on these parameters in 20 healthy pregnant subjects at 36 ± 2 weeks using magnetic resonance imaging (MRI); a follow-up MRI was performed 6-months postpartum (n = 16/20). MRI techniques included phase-contrast and T1/T2 relaxometry for blood flow and oximetry imaging, respectively. O2 transport was measured in the following vessels (bilateral where appropriate): maternal abdominal descending aorta (DAoabdo ), IVC, ovarian, paraspinal veins (PSV), uterine artery (UtA) and external iliacs, and umbilical. Maternal cardiac output was measured by summing DAothoracic and superior vena cava flows. Supine mothers (n = 6) had lower cardiac output and O2 delivery in the DAoabdo , UtA and external iliac arteries, and higher PSV flow than those in either the left (n = 8) or right (n = 6) lateral positions during MRI. However, O2 consumption in the gravid uterus, fetus, placenta and lower limbs was unaffected by maternal positioning. The ratio of IVC/PSV flow decreased in supine mothers while ovarian venous flow and O2 saturation were unaltered, suggesting a major route of pelvic venous return unaffected by maternal position. Placental-fetal O2 transport and consumption were similar between left and right lateral maternal positions. In comparison to non-pregnant findings, DAoabdo and UtA O2 delivery and pelvic O2 consumption increased, while lower-limb consumption remained constant , despite reduced external iliac artery O2 delivery in late gestation. KEY POINTS: Though sleeping supine during the third trimester is associated with an increased risk of antepartum stillbirth, the underlying biological mechanisms are not fully understood. Maternal cardiac output and uteroplacental flow are reduced in supine mothers due to inferior vena caval compression from the weight of the gravid uterus. This MRI study provides a comprehensive circulatory assessment, demonstrating reduced maternal cardiac output and O2 delivery (uteroplacental, lower body) in supine compared to lateral positioning; however, O2 consumption (gravid uterus, fetus, placenta, lower limbs) was preserved. Unlike other mammalian species, the ovarian veins conduct substantial venous return from the human pregnant uterus that is unaffected by maternal positioning. Lumbar paraspinal venous flow increased in supine mothers. These observations may have important considerations during major pelvic surgery in pregnancy (i.e. placenta percreta). Future studies should address the importance of maternal positioning as a potential tool to deliver improved perinatal outcomes in pregnancies with compromised uteroplacental O2 delivery.
Asunto(s)
Placenta , Vena Cava Superior , Femenino , Humanos , Embarazo , Estudios de Factibilidad , Feto/diagnóstico por imagen , Feto/irrigación sanguínea , Imagen por Resonancia Magnética , Oxígeno , Consumo de Oxígeno , Placenta/diagnóstico por imagenRESUMEN
OBJECTIVES: To assess abnormal liver enhancement on 15-20 min delayed 3D high-resolution late gadolinium enhancement (3D HR LGE) sequence in patients with Fontan circulation. METHODS: Retrospective study of pediatric Fontan patients (< 18 years old) with combined cardiac-liver MRI from January 2018 to August 2021. Abnormal hepatic enhancement was graded (0-3) for each lobe, summed for a total liver enhancement score (0-6), and compared to repaired tetralogy of Fallot (rTOF) patients. Correlations with other hepatic imaging biomarkers were performed. Temporal relationships of enhancement compared to traditional early portal venous and 5-7-min delayed phase liver imaging were analyzed. RESULTS: The Fontan group (n = 35, 13 ± 3.4 years old, median time from Fontan 10 (9-12) years) had 23/35 (66%) with delayed 3D HR LGE total liver enhancement score > 0 (range 0-5), with greater involvement of the right lobe (1 (0-1) vs 0 (0-1), p < 0.01). The rTOF group (n = 35, 14 ± 2.6 years old) had no abnormal enhancement. In the Fontan group, total liver enhancement was 3 (2-4) in the early portal venous phase, lower at 1 (1-2) in the 5-7-min delayed phase (p < 0.01), and lowest at 1 (0-2) in the 15-20-min delayed phase (p = 0.03). 3D HR LGE enhancement correlated inversely with portal vein flow (rs = - 0.42, p = 0.01) and positively with left lobe stiffness (rs = 0.51, p < 0.01). The enhancement score decreased in 13/35 (37%) between the 5-7- and 15-20-min delayed phases. CONCLUSIONS: Liver fibrosis can be assessed on 3D HR LGE sequences in patients with Fontan circulation, correlates with other imaging biomarkers of Fontan liver disease, and may add information for hepatic surveillance in this population. KEY POINTS: ⢠Abnormal liver enhancement on 3D HR LGE sequences in Fontan patients likely represents liver fibrosis and is seen in up to 66% of children and adolescents with variable distribution and severity. ⢠The degree of 3D HR LGE liver enhancement correlates with decreased portal vein flow and increased left hepatic lobe stiffness.
Asunto(s)
Procedimiento de Fontan , Tetralogía de Fallot , Humanos , Niño , Adolescente , Medios de Contraste , Gadolinio , Estudios Retrospectivos , Cirrosis Hepática/diagnóstico por imagen , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Imagen por Resonancia Magnética/métodos , BiomarcadoresRESUMEN
BACKGROUND: This study compares three-dimensional (3D) high-resolution (HR) late gadolinium enhancement (LGE; 3D HR-LGE) imaging using a respiratory navigated, electrocardiographically-gated inversion recovery gradient echo sequence with conventional LGE imaging using a single-shot phase-sensitive inversion recovery (PSIR) balanced steady-state free precession (bSSFP; PSIR-bSSFP) sequence for routine clinical use in the pediatric population. METHODS: Pediatric patients (0-18 years) who underwent clinical cardiovascular magnetic resonance (CMR) with both 3D HR-LGE and single-shot PSIR-bSSFP LGE between January 2018 and June 2020 were included. Image quality (0-4) and detection of LGE in the left ventricle (LV) (per 17 segments), in the right ventricle (RV) (per 3 segments), as endocardial fibroelastosis (EFE), at the hinge points, and at the papillary muscles was analyzed by two blinded readers for each sequence. Ratios of the mean signal intensity of LGE to normal myocardium (LGE:Myo) and to LV blood pool (LGE:Blood) were recorded. Data is presented as median (1st-3rd quartiles). Wilcoxon signed rank test and chi-square analyses were used as appropriate. Inter-rater agreement was analyzed using weighted κ-statistics. RESULTS: 102 patients were included with median age at CMR of 8 (1-13) years-old and 44% of exams performed under general anesthesia. LGE was detected in 55% of cases. 3D HR LGE compared to single-shot PSIR-bSSFP had longer scan time [4:30 (3:35-5:34) vs 1:11 (0:47-1:32) minutes, p < 0.001], higher image quality ratings [3 (3-4) vs 2 (2-3), p < 0.001], higher LGE:Myo [23.7 (16.9-31.2) vs 5.0 (2.9-9.0), p < 0.001], detected more segments of LGE in both the LV [4 (2-8) vs 3 (1-7), p = 0.045] and RV [1 (1-1) vs 1 (0-1), p < 0.001], and also detected more cases of LGE with 13/56 (23%) of patients with LGE only detectable by 3D HR LGE (p < 0.001). 3D HR LGE specifically detected a greater proportion of RV LGE (27/27 vs 17/27, p < 0.001), EFE (11/11 vs 5/11, p = 0.004), and papillary muscle LGE (14/15 vs 4/15, p < 0.001). Inter-rater agreement for the recorded variables ranged from 0.42 to 1.00. CONCLUSIONS: 3D HR LGE achieves greater image quality and detects more LGE than conventional single-shot PSIR-bSSFP LGE imaging, and should be considered an alternative to conventional LGE sequences for routine clinical use in the pediatric population.
Asunto(s)
Medios de Contraste , Cardiopatías Congénitas , Humanos , Niño , Lactante , Preescolar , Adolescente , Gadolinio , Estudios de Factibilidad , Valor Predictivo de las Pruebas , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/patología , Miocardio/patología , Imagen por Resonancia Magnética/métodosRESUMEN
Advances in cardiac surgical techniques taking place over the past 50 years have resulted in the vast majority of children born with congenital cardiac malformations now surviving into adulthood. As the focus shifts from survival to the functional outcomes of our patients, it is increasingly being recognized that a significant proportion of patients undergoing infant cardiac repair experience adverse neurodevelopmental (ND) outcomes. The etiology of abnormal brain development in the setting of congenital heart disease is poorly understood, complex, and likely multifactorial. Furthermore, the efficacy of therapies available for the learning disabilities, attention deficit, and hyperactivity disorders and other ND deficits complicating congenital heart disease is currently uncertain. This situation presents a challenge for prenatal counseling as current antenatal testing does not usually provide prognostic information regarding the likely ND trajectories of individual patients. However, we believe it is important for parents to be informed about potential issues with child development when a new diagnosis of congenital heart disease is disclosed. Parents deserve a comprehensive and thoughtful approach to this subject, which conveys the uncertainties involved in predicting the severity of any developmental disorders encountered, while emphasizing the improvements in outcomes that have already been achieved in infants with congenital heart disease. A balanced approach to counseling should also discuss what local arrangements are in place for ND follow-up. This review presents an up-to-date overview of ND outcomes in patients with congenital heart disease, providing possible approaches to communicating this information to parents during prenatal counseling in a sensitive and accurate manner.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Lactante , Niño , Humanos , Femenino , Embarazo , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Desarrollo Infantil , Pronóstico , ConsejoRESUMEN
Unplanned reinterventions following pulmonary artery banding (PAB) in single ventricle patients are common before stage 2 palliation (S2P) but associated risk factors are unknown. We hypothesized that reintervention is more common when PAB is placed at younger age and with a looser band, reflected by lower PAB pressure gradient. Retrospective single center study of single ventricle patients undergoing PAB between Jan 2000 and Dec 2020. The association with reintervention and successful S2P was modeled using exploratory cause-specific hazard regression. A multivariable model was developed adjusting for clinical and statistically relevant predictors. The cumulative proportion of patients undergoing reintervention were summarized using a competing risk model. 77 patients underwent PAB at median (IQR) 47 (24-66) days and 3.73 (3.2-4.5) kg. Within18 months of PAB, 60 (78%) reached S2P, 9 (12%) died, 1 (1%) transplanted and 7 (9%) were alive without S2P. Within 18 months of PAB 10 (13%) patients underwent reintervention related to pulmonary blood flow modification: PAB adjustment (n = 6) and conversion to Damus-Kaye-Stansel/Blalock-Taussig-Thomas shunt (n = 4). 6/10 (60%) reached S2P following reintervention. A trend toward higher intervention in patients with a genetic syndrome (p-0.06) and weight < 3 kg (p-0.057) at time of PAB was noted. Only genetic syndrome was a risk factor associated with poor outcome (p-0.025). PAB has a reasonable outcome in SV patients with unobstructed systemic and pulmonary blood flow, but with a high reintervention rate. Only a quarter of patients with genetic syndromes reach S2P and further study is required to explore the benefits from an alternative palliative strategy.
Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Corazón Univentricular , Humanos , Niño , Lactante , Arteria Pulmonar/cirugía , Cardiopatías Congénitas/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Ventrículos Cardíacos/cirugía , Cuidados PaliativosRESUMEN
OBJECTIVES: To evaluate the impact of fetal haemodynamics on surgical and neurodevelopmental outcomes in severe Ebstein anomaly and tricuspid valve dysplasia. METHODS: Thirty-four fetuses with Ebstein anomaly/tricuspid valve dysplasia were referred from 2013 to 2019 for fetal echocardiography and clinical management. Nineteen fetuses with Ebstein anomaly/tricuspid valve dysplasia and 30 controls underwent cardiovascular magnetic resonance to quantify the fetal blood flow and to calculate cerebral oxygen delivery (cDO2) and consumption (cVO2). The 3D steady-state free precession acquisition was used to measure fetal brain volume. Surgical outcome, brain MRI, and neurodevelopmental follow-up were reviewed. RESULTS: Twenty-six fetuses were live born (76%) and survival (65%) at a mean follow-up of 4 years. Nine fetuses had a brain MRI before discharge, and all had clinically silent injuries and volume loss. At 18 months, five single-ventricle patients had a neurodevelopmental delay in cognition and language (mean percentile: 11th), with gross-motor skills more affected than fine-motor skills (mean percentiles: 4th and 34th). Fetuses with Ebstein anomaly/tricuspid valve dysplasia had smaller brains, lower combined ventricular output, ascending aorta, superior caval vien and umbilical vein flows, lower oxygen saturation in ascending aorta and superior caval vien, lower cDO2 and cVO2 (p < 0.05). Superior caval vien/combined ventricular output and descending aorta/combined ventricular output ratios were lower in fetuses with circular shunt (p < 0.05). Fetuses requiring the Starnes procedure tended to have smaller brains, lower combined ventricular output, superior caval vien, descending aorta, and umbilical vein flows. CONCLUSIONS: All patients with Ebstein anomaly/tricuspid valve dysplasia are at high risk of neurodevelopmental delay and warrant follow-up. Fetal cardiovascular magnetic resonance revealed impaired brain growth with diminished cerebral blood flow and cDO2, the extenting dependent on the severity of the haemodynamic compromise.
Asunto(s)
Anomalía de Ebstein , Cardiopatías Congénitas , Femenino , Humanos , Anomalía de Ebstein/complicaciones , Anomalía de Ebstein/diagnóstico por imagen , Anomalía de Ebstein/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/anomalías , Vena Cava Superior , Estudios Retrospectivos , Hemodinámica , FetoRESUMEN
KEY POINTS: The margin of human viability has extended to the extremes of gestational age (<24 weeks) when the lungs are immature and ventilator-induced lung injury is common. Artificial placenta technology aims to extend gestation ex utero in order to allow the lungs additional time to develop prior to entering an air-breathing environment. We compared the haemodynamics and cerebral oxygenation of piglets in the immediate period post-oxygenator (OXY) transition against both paired in utero measures and uniquely against piglets transitioned onto mechanical ventilation (VENT). Post-transition, OXY piglets became hypotensive with reduced carotid blood flow in comparison with both paired in utero measures and VENT piglets. The addition of a pump to the oxygenator circuit may be required to ensure haemodynamic stability in the immediate post-transition period. ABSTRACT: Gestational age at birth is a major predictor of wellbeing; the lower the gestational age, the greater the risk of mortality and morbidity. At the margins of human viability (<24 weeks gestation) immature lungs combined with the need for early ventilatory support means lung injury and respiratory morbidity is common. The abrupt haemodynamic changes consequent on birth may also contribute to preterm-associated brain injury, including intraventricular haemorrhage. Artificial placenta technology aims to support oxygenation, haemodynamic stability and ongoing fetal development ex utero until mature enough to safely transition to a true ex utero environment. We aimed to characterize the impact of birth transition onto either an oxygenator circuit or positive pressure ventilation on haemodynamic and cerebral oxygenation of the neonatal piglet. At 112 days gestation (term = 115 days), fetal pigs underwent instrumentation surgery and transitioned onto either an oxygenator (OXY, n = 5) or ventilatory support (VENT, n = 8). Blood pressure (BP), carotid blood flow and cerebral oxygenation in VENT piglets rose from in utero levels to be significantly higher than OXY piglets post-transition. OXY piglet BP, carotid blood flow and carotid oxygen delivery (DO2 ) decreased from in utero levels post-transition; however, cerebral regional oxygen saturation (rSO2 ) was maintained at fetal-like levels. OXY piglets became hypoxaemic and retained CO2 . Whether OXY piglets are able to maintain cerebral rSO2 under these conditions for a prolonged period is yet to be determined. Improvements to OXY piglet oxygenation may lie in maintaining piglet BP at in utero levels and enhancing oxygenator circuit flow.
Asunto(s)
Pulmón , Respiración Artificial , Animales , Femenino , Edad Gestacional , Hemodinámica , Oxigenadores , Embarazo , PorcinosRESUMEN
KEY POINTS: Human placental function is evaluated using non-invasive Doppler ultrasound of umbilical and uterine artery pulsatility indices as measures of resistance in placental vascular beds, while measurement of placental oxygen consumption ( VO2 ) is only possible during Caesarean delivery. This study shows the feasibility of using magnetic resonance imaging (MRI) in utero to measure blood flow and oxygen content in uterine and umbilical vessels to calculate oxygen delivery to and VO2 by the gravid uterus, uteroplacenta and fetus. Normal late gestational human uteroplacental VO2 by MRI was â¼4 ml min-1 kg-1 fetal weight, which was similar to our MRI measurements in sheep and to those previously measured using invasive techniques. Our MRI approach can quantify uteroplacental VO2 , which involves the quantification of maternal- and fetal-placental blood flows, fetal oxygen delivery and VO2 , and the oxygen gradient between uterine- and umbilical-venous blood, providing a comprehensive assessment of placental function with clinical potential. ABSTRACT: It has not been feasible to perform routine clinical measurement of human placental oxygen consumption ( VO2 ) and in vitro studies do not reflect true metabolism in utero. Here we propose an MRI method to non-invasively quantify in utero placental and fetal oxygen delivery ( DO2 ) and VO2 in healthy humans and sheep. Women (n = 20) and Merino sheep (n = 10; 23 sets of measurements) with singleton pregnancies underwent an MRI in late gestation (36 ± 2 weeks and 128 ± 9 days, respectively; mean ± SD). Blood flow (phase-contrast) and oxygen content (T1 and T2 relaxometry) were measured in the major uterine- and umbilical-placental vessels, allowing calculation of uteroplacental and fetal DO2 and VO2 . Maternal DO2 (ml min-1 kg-1 fetus) to the gravid uterus was similar in humans and sheep (human = 54 ± 15, sheep = 53 ± 21, P = 0.854), while fetal DO2 (human = 25 ± 4, sheep = 22 ± 5, P = 0.049) was slightly lower in sheep. Uteroplacental and fetal VO2 (ml min-1 kg-1 fetus; uteroplacental: human = 4.1 ± 1.5, sheep = 3.5 ± 1.9, P = 0.281; fetus: human = 6.8 ± 1.3, sheep = 7.2 ± 1.7, P = 0.426) were similar between species. Late gestational uteroplacental:fetal VO2 ratio did not change with age (human, P = 0.256; sheep, P = 0.121). Human umbilical blood flow (ml min-1 kg-1 fetus) decreased with advancing age (P = 0.008), while fetal VO2 was preserved through an increase in oxygen extraction (P = 0.046). By contrast, sheep fetal VO2 was preserved through stable umbilical flow (ml min-1 kg-1 ; P = 0.443) and oxygen extraction (P = 0.582). MRI derived measurements of uteroplacental and fetal VO2 between humans and sheep were similar and in keeping with prior data obtained using invasive techniques. Taken together, these data confirm the reliability of our approach, which offers a novel clinical 'placental function test'.
Asunto(s)
Placenta , Circulación Placentaria , Animales , Femenino , Feto/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Placenta/diagnóstico por imagen , Embarazo , Reproducibilidad de los Resultados , Ovinos , Útero/diagnóstico por imagenRESUMEN
Restriction of fetal substrate supply has an adverse effect on surfactant maturation in the lung and thus affects the transition from in utero placental oxygenation to pulmonary ventilation ex utero. The effects on surfactant maturation are mediated by alteration in mechanisms regulating surfactant protein and phospholipid synthesis. This study aimed to determine the effects of late gestation maternal undernutrition (LGUN) and LGUN plus fetal glucose infusion (LGUN+G) compared to Control on surfactant maturation and lung development, and the relationship with pulmonary blood flow and oxygen delivery ( DO2 ) measured by magnetic resonance imaging (MRI) with molecules that regulate lung development. LGUN from 115 to 140 days' gestation significantly decreased fetal body weight, which was normalized by glucose infusion. LGUN and LGUN+G resulted in decreased fetal plasma glucose concentration, with no change in fetal arterial PO2 compared to control. There was no effect of LGUN and LGUN+G on the mRNA expression of surfactant proteins (SFTP) and genes regulating surfactant maturation in the fetal lung. However, blood flow in the main pulmonary artery was significantly increased in LGUN, despite no change in blood flow in the left or right pulmonary artery and DO2 to the fetal lung. There was a negative relationship between left pulmonary artery flow and DO2 to the left lung with SFTP-B and GLUT1 mRNA expression, while their relationship with VEGFR2 was positive. These results suggest that increased pulmonary blood flow measured by MRI may have an adverse effect on surfactant maturation during fetal lung development. KEY POINTS: Maternal undernutrition during gestation alters fetal lung development by impacting surfactant maturation. However, the direction of change remains controversial. We examined the effects of maternal late gestation maternal undernutrition (LGUN) on maternal and fetal outcomes, signalling pathways involved in fetal lung development, pulmonary haemodynamics and oxygen delivery in sheep using a combination of molecular and magnetic resonance imaging (MRI) techniques. LGUN decreased fetal plasma glucose concentration without affecting arterial PO2 . Surfactant maturation was not affected; however, main pulmonary artery blood flow was significantly increased in the LGUN fetuses. This is the first study to explore the relationship between in utero MRI measures of pulmonary haemodynamics and lung development. Across all treatment groups, left pulmonary artery blood flow and oxygen delivery were negatively correlated with surfactant protein B mRNA and protein expression in late gestation.
Asunto(s)
Desnutrición , Circulación Pulmonar , Animales , Femenino , Feto , Imagen por Resonancia Magnética , Intercambio Materno-Fetal , Oxígeno , Placenta , Embarazo , Ovinos , TensoactivosRESUMEN
BACKGROUND: Phase contrast MRI in the great vessels is a potential clinical tool for managing fetal pathologies. One challenge is the uncontrollable fetal motion, potentially corrupting flow quantifications. PURPOSE: To demonstrate improvements in fetal blood flow quantification in great vessels using retrospectively motion-corrected golden-angle radial phase contrast MRI relative to Cartesian phase contrast MRI. STUDY TYPE: Method comparison. PHANTOM/SUBJECTS: Computer simulation. Seventeen pregnant volunteers. FIELD STRENGTH/SEQUENCE: 1.5T and 3T. Cartesian and golden-angle radial phase contrast MRI. ASSESSMENT: Through computer simulations, radial (with and without retrospective motion correction) and Cartesian phase contrast MRI were compared using flow deviations. in vivo Cartesian and radial phase contrast MRI measurements and reconstruction qualities were compared in pregnancies. Cartesian data were reconstructed into gated reconstructions (CINEs) after cardiac gating with metric optimized gating (MOG). For radial data, real-time reconstructions were performed for motion correction and MOG followed by CINE reconstructions. STATISTICAL TESTS: Wilcoxon signed-rank test. Linear regression. Bland-Altman plots. Student's t-test. RESULTS: Simulations showed significant improvements (P < 0.05) in flow accuracy and reconstruction quality with motion correction ([mean/peak] flow errors with ±5 mm motion corruption: Cartesian [35 ± 1/115 ± 7] mL/s, motion uncorrected radial [25 ± 1/75 ± 2] mL/s and motion-corrected radial [1.0 ± 0.5/-5 ± 1] mL/s). in vivo Cartesian reconstructions without motion correction had lower quality than the motion-corrected radial reconstructions (P < 0.05). Across all fetal mean flow measurements, the bias [limits of agreement] between the two measurements were -0.2 [-76, 75] mL/min/kg, while the linear regression coefficients were (Mradial = 0.81 × MCartesian + 29.8 [mL/min/kg], r2 = 0.67). The corresponding measures for the peak fetal flows were -23 [-214, 167] mL/min/kg and (Pradial = 0.95 × PCartesian -1.2 [mL/min/kg], r2 = 0.80). Cartesian reconstructions of low quality showed significantly higher estimated mean and peak (P < 0.05) flows than the corresponding radial reconstructions. DATA CONCLUSION: Simulations showed that radial phase contrast MRI with motion compensation improved flow accuracy. For fetal measurements, motion-corrected radial reconstructions showed better image quality than, and different flow values from, Cartesian reconstructions. Level of Evidence 1. Technical Efficacy Stage 1. J. MAGN. RESON. IMAGING 2021;53:540-551.
Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Simulación por Computador , Femenino , Humanos , Movimiento (Física) , Embarazo , Reproducibilidad de los Resultados , Estudios RetrospectivosRESUMEN
NEW FINDINGS: What is the central question of this study? Uterine artery blood flow helps to maintain fetal oxygen and nutrient delivery. We investigated the effects of increased uterine artery blood flow mediated by resveratrol on fetal growth, haemodynamics, blood pressure regulation and oxygenation in pregnant sheep. What is the main finding and its importance? Fetuses from resveratrol-treated ewes were significantly larger and exhibited a haemodynamic profile that might promote peripheral growth. Absolute uterine artery blood flow was positively correlated with umbilical vein oxygen saturation, absolute fetal oxygen delivery and fetal growth. Increasing uterine artery blood flow with compounds such as resveratrol might have clinical significance for pregnancy conditions in which fetal growth and oxygenation are compromised. ABSTRACT: High placental vascular resistance hinders uterine artery (UtA) blood flow and fetal substrate delivery. In the same group of animals as the present study, we have previously shown that resveratrol (RSV) increases UtA blood flow, fetal weight and oxygenation in an ovine model of human pregnancy. However, the mechanisms behind changes in growth and the effects of increases in UtA blood flow on fetal circulatory physiology have yet to be investigated. Twin-bearing ewes received s.c. vehicle (VEH, n = 5) or RSV (n = 6) delivery systems at 113 days of gestation (term = 150 days). Magnetic resonance imaging was performed at 123-124 days to quantify fetal volume, blood flow and oxygen saturation of major fetal vessels. At 128 days, i.v. infusions of sodium nitroprusside and phenylephrine were administered to study the vascular tone of the fetal descending aorta. Maternal RSV increased fetal body volume (P = 0.0075) and weight (P = 0.0358), with no change in brain volume or brain weight. There was a positive relationship between absolute UtA blood flow and umbilical vein oxygen saturation, absolute fetal oxygen delivery and combined fetal twin volume (all P ≤ 0.05). There were no differences between groups in fetal haemodynamics or blood pressure regulation except for higher blood flow to the lower body in RSV fetuses (P = 0.0170). The observed increase in fetal weight might be helpful in pregnancy conditions in which fetal growth and oxygen delivery are compromised. Further preclinical investigations on the mechanism(s) accounting for these changes and the potential to improve growth in complicated pregnancies are warranted.
Asunto(s)
Placenta , Arteria Uterina , Animales , Presión Sanguínea , Femenino , Feto , Hemodinámica , Embarazo , Resveratrol/farmacología , Ovinos , Arteria Uterina/fisiologíaRESUMEN
BACKGROUND: The extent and significance in of cardiac remodeling in Fontan patients are unclear and were the subject of this study. METHODS: This retrospective cohort study compared cardiovascular magnetic resonance (CMR) imaging markers of cardiac function, myocardial fibrosis, and hemodynamics in young Fontan patients to controls. RESULTS: Fifty-five Fontan patients and 44 healthy controls were included (median age 14 years (range 7-17 years) vs 13 years (range 4-14 years), p = 0.057). Fontan patients had a higher indexed end-diastolic ventricular volume (EDVI 129 ml/m2 vs 93 ml/m2, p < 0.001), and lower ejection fraction (EF 45% vs 58%, p < 0.001), circumferential (CS - 23.5% vs - 30.8%, p < 0.001), radial (6.4% vs 8.2%, p < 0.001), and longitudinal strain (- 13.3% vs - 24.8%, p < 0.001). Compared to healthy controls, Fontan patients had higher extracellular volume fraction (ECV) (26.3% vs 20.6%, p < 0.001) and native T1 (1041 ms vs 986 ms, p < 0.001). Patients with a dominant right ventricle demonstrated larger ventricles (EDVI 146 ml/m2 vs 120 ml/m2, p = 0.03), lower EF (41% vs 47%, p = 0.008), worse CS (- 20.1% vs - 25.6%, p = 0.003), and a trend towards higher ECV (28.3% versus 24.1%, p = 0.09). Worse EF and CS correlated with longer cumulative bypass (R = - 0.36, p = 0.003 and R = 0.46, p < 0.001), cross-clamp (R = - 0.41, p = 0.001 and R = 0.40, p = 0.003) and circulatory arrest times (R = - 0.42, p < 0.001 and R = 0.27, p = 0.03). T1 correlated with aortopulmonary collateral (APC) flow (R = 0.36, p = 0.009) which, in the linear regression model, was independent of ventricular morphology (p = 0.9) and EDVI (p = 0.2). The composite outcome (cardiac readmission, cardiac reintervention, Fontan failure or any clinically significant arrhythmia) was associated with increased native T1 (1063 ms vs 1026 ms, p = 0.029) and EDVI (146 ml/m2 vs 118 ml/m2, p = 0.013), as well as decreased EF (42% vs 46%, p = 0.045) and worse CS (- 22% vs - 25%, p = 0.029). APC flow (HR 5.5 CI 1.9-16.2, p = 0.002) was independently associated with the composite outcome, independent of ventricular morphology (HR 0.71 CI 0.30-1.69 p = 0.44) and T1 (HR1.006 CI 1.0-1.13, p = 0.07). CONCLUSIONS: Pediatric Fontan patients have ventricular dysfunction, altered myocardial mechanics and increased fibrotic remodeling. Cumulative exposure to cardiopulmonary bypass and increased aortopulmonary collateral flow are associated with myocardial dysfunction and fibrosis. Cardiac dysfunction, fibrosis, and collateral flow are associated with adverse outcomes.
Asunto(s)
Ventrículos Cardíacos , Imagen por Resonancia Cinemagnética , Adolescente , Niño , Fibrosis , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/cirugía , Humanos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Función Ventricular IzquierdaRESUMEN
BACKGROUND: Cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) requires identification of the normal myocardial nulling time using inversion time (TI)-scout imaging sequence. Although TI-scout images are not primarily used for myocardial assessment, they provide information regarding different signal recovery patterns of normal and abnormal myocardium facilitating identification of LGE in instances where standard LGE images alone are not diagnostic. We aimed to assess the diagnostic performance of TI-scout as compared to that of standard LGE images. METHODS: CMR studies with LGE imaging in 519 patients (345 males, 1-17 years) were reviewed to assess the diagnostic performance of LGE imaging in terms of the location of LGE and the pathologic entities. The diagnostic performance of the TI-scout and standard LGE imaging was classified into four categories: (1) equally diagnostic, (2) TI-scout superior to standard LGE, (3) standard LGE superior to TI-scout, and (4) complementary, by the consensus of the two observers. RESULTS: The study cohort consisted of 440 patients with negative LGE and 79 with evidence for LGE. For a negative diagnosis of LGE, TI-scout and standard LGE images were equally diagnostic in 75% of the cases and were complementary in 12%. For patients with LGE, TI-scout images were superior to standard LGE images in 52% of the cases and were complementary in 19%. The diagnostic performance of TI-scout images was superior to that of standard LGE images in all locations. TI-scout images were superior to standard LGE images in 11 of 12 (92%) cases with LGE involving the papillary muscles, in 7 /12 (58%) cases with subendocardial LGE, and in 4/7 (57%) cases with transmural LGE. TI-scout images were particularly useful assessing the presence and extent of LGE in hypertrophic cardiomyopathy (HCM). TI-scout was superior to standard LGE in 6/10 (60%) and was complementary in 3/10 (30%) of the positive cases with HCM. CONCLUSIONS: TI-scout images enhance the diagnostic performance of LGE imaging in children.