Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38450808

RESUMEN

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Asunto(s)
Remoción de Dispositivos , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Masculino , Femenino , Remoción de Dispositivos/efectos adversos , Anciano , Resultado del Tratamiento , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Desfibriladores Implantables , Factores de Tiempo , Marcapaso Artificial , Anciano de 80 o más Años , Dispositivos de Terapia de Resincronización Cardíaca
2.
J Cardiovasc Electrophysiol ; 34(5): 1111-1118, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37036297

RESUMEN

INTRODUCTION: Hemodynamic decompensation during catheter ablation occurs due to prolonged procedure time and irrigant delivery directly into the cardiac chambers. Real-time hemodynamic monitoring of patients undergoing catheter ablation procedures may identify patients at risk of decompensation; we set out to assess the feasibility of a novel, real-time, intracardiac pressure monitoring system using a standard irrigated ablation catheter. METHODS: We studied 13 consecutive who underwent pressure measurement of the left atrium (LA) and left ventricle (LV) via transeptal access with a Swan Ganz (SG) catheter followed by two commercially available irrigated ablation catheters. Pressure waveform data was extracted to compare LA peak pressure, LV peak systolic pressure, LV end-diastolic pressure, and waveform analysis. RESULTS: Comparison between the SG and ablation catheters (AblA; AblB) demonstrated that LV systolic pressure (0.61-16.8 mmHg; 1.32-18.2 mmHg), and LV end-diastolic pressure (-3.4 to 2.8 mmHg; -3.0 to 3.35 mmHg) were well correlated and had accepted repeatability. Ablation waveforms demonstrated an 89.9 ± 6.4% correlation compared to SG waveforms. CONCLUSION: Pressure measurements derived from an irrigated ablation catheter are accurate and reliable when compared to an SG catheter. Further studies are needed to determine how real-time pressure monitoring can improve outcomes during ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Hemodinámica , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702135

RESUMEN

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
4.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38000900

RESUMEN

AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.


Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Falla de Equipo , Estudios Retrospectivos
5.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38006390

RESUMEN

AIMS: The mechanisms of transition from regular rhythms to ventricular fibrillation (VF) are poorly understood. The concordant to discordant repolarization alternans pathway is extensively studied; however, despite its theoretical centrality, cannot guide ablation. We hypothesize that complex repolarization dynamics, i.e. oscillations in the repolarization phase of action potentials with periods over two of classic alternans, is a marker of electrically unstable substrate, and ablation of these areas has a stabilizing effect and may reduce the risk of VF. To prove the existence of higher-order periodicities in human hearts. METHODS AND RESULTS: We performed optical mapping of explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Signals recorded from the right ventricle endocardial surface were processed to detect global and local repolarization dynamics during rapid pacing. A statistically significant global 1:4 peak was seen in three of six hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of Periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. CONCLUSION: We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.


Asunto(s)
Ventrículos Cardíacos , Corazón , Humanos , Arritmias Cardíacas , Fibrilación Ventricular/cirugía , Potenciales de Acción/fisiología
6.
Ann Noninvasive Electrocardiol ; 28(5): e13073, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37515396

RESUMEN

BACKGROUND: The use of a Left Ventricular Assist Device (LVAD) in patients with advanced heart failure refractory to optimal medical management has progressed steadily over the past two decades. Data have demonstrated reduced LVAD efficacy, worse clinical outcome, and higher mortality for patients who experience significant ventricular tachyarrhythmia (VTA). We hypothesize that a novel prophylactic intra-operative VTA ablation protocol at the time of LVAD implantation may reduce the recurrent VTA and adverse events postimplant. METHODS: We designed a prospective, multicenter, open-label, randomized-controlled clinical trial enrolling 100 patients who are LVAD candidates with a history of VTA in the previous 5 years. Enrolled patients will be randomized in a 1:1 fashion to intra-operative VTA ablation (n = 50) versus conventional medical management (n = 50) with LVAD implant. Arrhythmia outcomes data will be captured by an implantable cardioverter defibrillator (ICD) to monitor VTA events, with a uniform ICD programming protocol. Patients will be followed prospectively over a mean of 18 months (with a minimum of 9 months) after LVAD implantation to evaluate recurrent VTA, adverse events, and procedural outcomes. Secondary endpoints include right heart function/hemodynamics, healthcare utilization, and quality of life. CONCLUSION: The primary aim of this first-ever randomized trial is to assess the efficacy of intra-operative ablation during LVAD surgery in reducing VTA recurrence and improving clinical outcomes for patients with a history of VTA.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Taquicardia Ventricular , Humanos , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Electrocardiografía , Arritmias Cardíacas , Taquicardia Ventricular/etiología , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 32(2): 484-490, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33251698

RESUMEN

BACKGROUND: Data on the management of Micra transcatheter pacing system (TPS) at the time of an upgrade or during battery depletion is limited. OBJECTIVE: We sought to evaluate the management patterns of patients implanted with a Micra TPS during long-term follow-up. METHODS: We retrospectively identified patients who underwent Micra implantation from April 2014 to November 2019. We identified patients who underwent extraction (n = 11) or had an abandoned Micra (n = 12). RESULTS: We identified 302 patients who received a Micra during the period of the study. Mean age was 72.7 ± 15.4 years, 54.6% were men, and left ventricular ejection fraction was 51.9 ± 5.2%. Mean follow-up was 1105.5 ± 529.3 days. Procedural complications included pericardial tamponade (n = 1) treated with pericardiocentesis, significant rise in thresholds (n = 6) treated with reimplantation (n = 4), and major groin complications (n = 2). Indications for extraction included an upgrade to cardiac resynchronization therapy (CRT) device (n = 3), bridging after extraction of an infected transvenous system (n = 3), elevated thresholds (n = 3), and non-Micra-related bacteremia (n = 2). The median time from implantation to extraction was 78 days (interquartile range: 14-113 days), with the longest extraction occurring at 1442 days. All extractions were successful, with no procedural or long-term complications. Indications for abandonment included the need for CRT (n = 6), battery depletion (n = 2), increasing thresholds/failure to capture (n = 3), and pacemaker syndrome (n = 1). All procedures were successful, with no procedural or long-term complications. CONCLUSION: In this large single-center study, 6% of patients implanted with a Micra required a system modification during long-term follow-up, most commonly due to the requirement for CRT pacing. These patients were managed successfully with extraction or abandonment.


Asunto(s)
Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Animales , Diseño de Equipo , Humanos , Estadios del Ciclo de Vida , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
8.
J Cardiovasc Electrophysiol ; 31(12): 3176-3186, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32966681

RESUMEN

BACKGROUND: Women undergoing atrial fibrillation catheter ablation (AFCA) have higher rates of vascular complications and major bleeding. However, most studies have been underpowered to detect differences in rarer complications such as stroke/transient ischemic attack (TIA) and procedural mortality. METHODS: We performed a systematic review of databases (PubMed, World of Science, and Embase) to identify studies published since 2010 reporting AFCA complications by sex. Six complications of interest were (1) vascular/groin complications; (2) pericardial effusion/tamponade; (3) stroke/TIA; (4) permanent phrenic nerve injury; (5) major bleeding; and (6) procedural mortality. For meta-analysis, random effects models were used when heterogeneity between studies was ≥50% (vascular complications and major bleeding) and fixed effects models for other endpoints. RESULTS: Of 5716 citations, 19 studies met inclusion criteria, comprising 244,353 patients undergoing AFCA, of whom 33% were women. Women were older (65.3 ± 11.2 vs. 60.4 ± 13.2 years), more likely hypertensive (60.6% vs. 55.5%) and diabetic (18.3% vs. 16.5%), and had higher CHA2 DS2 -VASc scores (3.0 ± 1.8 vs. 1.4 ± 1.4) (p < .0001 for all comparisons). The rates of all six complications were significantly higher in women. However, despite statistically significant differences, the overall incidences of major complications were very low in both sexes: stroke/TIA (women 0.51% vs. men 0.39%) and procedural mortality (women 0.25% vs. men 0.19%). CONCLUSION: Women experience significantly higher rates of AFCA complications. However, the incidence of major procedural complications is very low in both sexes. The higher rate of complications in women may be partially attributable to older age and a higher prevalence of comorbidities at the time of ablation. More detailed studies are needed to better define the mechanisms of increased risk in women and to identify strategies for closing the sex gap.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Hemorragia , Humanos , Ataque Isquémico Transitorio/diagnóstico , Ataque Isquémico Transitorio/epidemiología , Ataque Isquémico Transitorio/etiología , Masculino , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
9.
J Cardiovasc Electrophysiol ; 30(8): 1313-1318, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31045296

RESUMEN

BACKGROUND: Implantation of the MICRA Leadless pacemaker requires the use of a 27 French introducer, blunt delivery system and device fixation to the myocardium via nitinol tines. While prior studies have proven its safety, it is unclear whether performing this procedure with uninterrupted anticoagulation exposes patients to increased risks. We sought to investigate the feasibility and safety of continuing therapeutic anticoagulation during the periprocedural period. METHODS: We evaluated all patients undergoing MICRA placement at our institution between April 2014 and August 2018 with complete follow-up data (n = 170). Patients were stratified into two groups: those on active anticoagulation (OAC, n = 26), defined as having an International normalized ratio >2.0 or having continued a direct oral anticoagulant, and those not anticoagulated (Off-OAC, n = 144). We evaluated for a composite outcome of all major complications, including access site complications and pericardial effusion. RESULTS: OAC and Off-OAC groups had similar mean age (74 ± 13 vs 75 ± 13 years; P = .914). The OAC group had a nonsignificantly lower prevalence of end-stage renal disease (8% vs 17%; P = .375) and aspirin use (27% vs 47%; P = .131). Those in the OAC group were more likely to be on warfarin than those in the Off-OAC group (81% vs 30%; P < .001). The rate of the composite endpoint was similar between the OAC and Off-OAC groups (3.8 % vs 1.4%, respectively; P = .761). Length of stay was similar between groups (1.3 ± 2.6 vs 2.3 ± 3.4 days; P = 0.108). CONCLUSION: Continuation of therapeutic anticoagulation during MICRA implantation appears to be feasible, safe and associated with shorter hospitalization among appropriately selected individuals.


Asunto(s)
Anticoagulantes/administración & dosificación , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Esquema de Medicación , Diseño de Equipo , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
Europace ; 19(12): 1994-2000, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28065887

RESUMEN

AIMS: End-stage renal disease (ESRD) increases the risk of implantable cardioverter-defibrillator (ICD) infection. We sought to define outcomes of lead extraction in patients with ESRD. METHODS AND RESULTS: Implantable cardioverter-defibrillator lead extractions at our institution from January 2006 to March 2014 were stratified by absence (Control-Ex, n = 465) or presence (ESRD-Ex, n = 43) of ESRD. Procedural outcomes and survival were determined by medical records review. Survival in the ESRD-Ex group was compared with a contemporaneous cohort with ESRD undergoing ICD lead implantation (ESRD-I, n = 127). Among extraction patients, those with ESRD were more likely to be extracted for infection (74.4% vs. 28.6%, P < 0.001). Extraction procedure success (Control-Ex: 97% vs. ESRD-Ex: 93%, P = 0.17) and procedural deaths (Control-Ex: 1.1% vs. ESRD-Ex: 2.3%, P = 0.413) were similar. Survival 1 year following extraction was worse in the ESRD-Ex group compared with the Control-Ex, with a survival rate of 65.6% vs. 92.6% (P < 0.001); these curves continued to diverge through year 3. One-year survival in the ESRD-Ex group was worse than among ESRD patients undergoing ICD implant (ESRD-I), but these curves converged and survival was similar by year 3. CONCLUSIONS: Implantable cardioverter-defibrillator lead extraction can be performed safely and effectively in patients with ESRD. However, despite high rates of procedural success, long-term mortality following extraction in ESRD patients is substantial. Much of the long-term mortality risk appears to be accounted for by the presence of ESRD and an indication for an ICD.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Fallo Renal Crónico/complicaciones , Falla de Prótesis , Infecciones Relacionadas con Prótesis/cirugía , Adulto , Anciano , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/mortalidad , Cardioversión Eléctrica/mortalidad , Femenino , Georgia , Humanos , Estimación de Kaplan-Meier , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/mortalidad , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Pacing Clin Electrophysiol ; 40(5): 467-475, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28224629

RESUMEN

OBJECTIVES: This study compared risks associated with magnetic resonance imaging (MRI) in patients with non-MRI conditional and MRI conditional pacing and defibrillator systems with particular attention to clinically actionable outcomes. BACKGROUND: While recipients of new MRI conditional pacemaker and defibrillator systems may undergo MRI scanning with very low risk, safety and regulatory concerns persist regarding such scanning in recipients of non-MRI conditional systems. METHODS: Patients with any cardiac device who were referred for MRI were prospectively enrolled at a single center and underwent scanning at 1.5 Tesla. Pre- and postscan lead characteristic changes, system integrity, and symptoms were analyzed. A comparison was made between non-MRI conditional and MRI conditional devices. RESULTS: 105 patients were evaluated allowing for comparison of 97 scans with non-MRI conditional devices and 16 scans with MRI conditional devices. The cohort included those with pacemaker dependency, defibrillator, and cardiac resynchronization devices. Small, nonsignificant changes were observed in lead characteristics following scanning, and there was no significant difference when comparing non-MRI and MRI conditional devices. Lead parameter changes did not require lead revision or programming changes. No device reset, failures, or premature scan termination was observed. CONCLUSIONS: 1.5 T MRI scanning in patients with MRI conditional and non-MRI conditional cardiac devices was performed with similar, low clinical risk.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Traumatismos por Electricidad/epidemiología , Falla de Equipo/estadística & datos numéricos , Seguridad de Equipos/estadística & datos numéricos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/estadística & datos numéricos , Marcapaso Artificial/estadística & datos numéricos , Anciano , Causalidad , Contraindicaciones , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Georgia/epidemiología , Humanos , Masculino , Prevalencia , Factores de Riesgo
12.
J Cardiovasc Electrophysiol ; 27(7): 820-4, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27037913

RESUMEN

INTRODUCTION: Intracardiac electrogram voltage remains an important metric for radiofrequency lesion application. Embedded micro-electrodes within ablation catheters are now approved for use in humans. OBJECTIVE: This study examined electrogram characteristics of miniaturized electrode bipoles (iEGMmini ) compared to distal ablation tip bipoles (iEGMstandard ) in the setting of typical atrial flutter in humans. METHODS: This was a single-center prospective trial involving 21 patients. A total of 54 non-ablated and 56 ablated sites were analyzed offline by separate blinded observers for iEGM voltage after a clinically successful radiofrequency (RF) ablation for typical atrial flutter. Ablation sites were defined as sites that were localized anatomically within the RF lesion set and did not have atrial capture at 10 mA and 2 milliseconds. Non-ablated sites were defined as sites adjacent to or remote from the ablation lesion set with capture at 10 mA and 2 milliseconds. RESULTS: iEGMmini had greater voltages at non-ablated sites and lower voltages at ablated sites than iEGMstandard (non-ablated sites iEGMstandard 0.64 mV vs. iEGMmini 1.0 mV; ablated sites iEGMstandard 0.15 mV, iEGMmini 0.08 mV, P < 0.001). The difference for each patient between ablated and non-ablated sites was greater for iEGMmini compared to iEGMstandard (0.94 mV ± 0.57 iEGMmini vs. 0.52 mV ± 0.35 iEGMstandard , P < 0.001). Inter-observer agreement was good among all non-ablated sites and iEGMmini ablated sites, but was less robust for ablated sites using iEGMstandard . CONCLUSIONS: Imbedded mini-electrode iEGM bipoles had higher voltages in non-ablated tissue, lower voltages in ablated tissue, and significantly greater intra-patient differences between ablated and non-ablated sites. These data suggest a potential role for miniaturized electrode bipole use in RF lesion monitoring.


Asunto(s)
Aleteo Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Electrodos Implantados , Técnicas Electrofisiológicas Cardíacas , Miocardio/patología , Potenciales de Acción , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Diseño de Equipo , Georgia , Frecuencia Cardíaca , Humanos , Miniaturización , Valor Predictivo de las Pruebas , Estudios Prospectivos , Resultado del Tratamiento
13.
AJR Am J Roentgenol ; 207(3): 599-604, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27304515

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the safety and diagnostic utility of 1.5-T MRI examinations of individuals with conventional and MRI-conditional cardiac implantable electronic devices (CIEDs). SUBJECTS AND METHODS: Patients with a CIED who were referred for MRI were evaluated by radiologists and cardiac electrophysiologists for study participation. CIED interrogation was performed immediately before and after MRI, and cardiac telemetry monitoring was performed during MRI. CIED programming changes, malfunctions, and intraprocedural events were documented. Whether diagnostic questions were answered and whether artifacts related to the CIED were present and negatively affected image interpretation were recorded. RESULTS: One hundred thirteen MRI examinations were performed for 104 patients with CIEDs (74 pacemakers [60 conventional, 14 MRI conditional]; 39 implantable cardiac defibrillators). Device reprogramming was required before MRI for 62.8% of studies (71/113). No significant changes in lead parameters were noted during or after MRI. Electromagnetic noise was detected on at least one lead in 7.1% of studies. Three patients reported transient symptoms (one case each of heating at the pocket site, tingling at the pocket site, and palpitations). All images were considered diagnostic for the original clinical query. Artifacts related to CIEDs were described in 3.5% of MRI reports (4/113) and were present only when the pulse generator was included in the FOV. CIED-related artifacts limited evaluation of tissues immediately adjacent to the pulse generator. CONCLUSION: Establishment of a multidisciplinary work flow allows individuals with conventional and MRI-conditional CIEDs to safely undergo 1.5-T MRI with diagnostic questions consistently answered.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética/métodos , Marcapaso Artificial , Seguridad del Paciente , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad
14.
Pacing Clin Electrophysiol ; 39(1): 101-4, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26293817

RESUMEN

Defibrillator lead malfunction can be a disastrous complication, leading to loss of protection from sudden cardiac death in a high-risk patient population. Recognition of lead-specific risk for failure can assist in development of focused screening or surveillance, as in the case of the Riata lead (St. Jude Medical, St. Paul, MN, USA) or the Sprint Fidelis lead (Medtronic Inc., Minneapolis, MN, USA). A case of defibrillation failure secondary to a Durata lead insulation failure is presented. A brief review of the literature and current St. Jude Medical implantable cardiac defibrillator lead design is presented. Identification of arcing is identified as a potential sign of catastrophic insulation failure.


Asunto(s)
Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Adulto , Falla de Equipo , Resultado Fatal , Humanos , Masculino , Insuficiencia del Tratamiento
15.
Heart Rhythm ; 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38752909

RESUMEN

BACKGROUND: Because of differences in chest wall anatomy, female patients may have higher rates of subcutaneous implantable cardioverter-defibrillator (S-ICD) pocket-related complications. OBJECTIVE: We sought to evaluate sex-based outcomes after S-ICD implantation. METHODS: Patients implanted with an S-ICD at Emory Healthcare between 2010 and 2023 were included in the analysis. Patients' clinical characteristics and post-S-ICD implantation complications were collected. RESULTS: There were 429 male patients (68%) and 199 female patients (32%) observed for a median duration of 2.3 years (0.6-4.4 years). Male and female patients had comparable rates of diabetes (28%), end-stage renal disease (29.5%), ejection fraction (30.2% ± 13.4%), and body mass index (29.1 ± 6.6 kg/m2). There was no statistical difference in the incidence of shocks between men and women (26.3% vs 20.1%; P = .09), including appropriate shocks (14.7% vs 12%; P = .98) and inappropriate shocks (11.7% vs 9.5%; P = .98). Pocket-related complications occurred in 21 patients; these included pocket infection (n = 12), wound dehiscence (n = 7), and hematoma requiring drainage (n = 2). Female patients had a significantly higher pocket-related complication rate compared with male patients (7.2% vs 2.5%; P = .016). In controlling for age, body mass index, diabetes, and end-stage renal disease, female patients had higher odds of pocket-related complications compared with male patients (odds ratio, 3.15; 95% confidence interval, 1.27-7.75). Pocket-related complications decreased after 2018 compared with before 2018 (6% vs 2.6%, P = .052), mainly driven by reduction in complications in women (12.3% vs 3.2%; P = .034) but not in men (2.8% vs 2.4%; P = 1). CONCLUSION: In this cohort of S-ICD patients, women had a higher rate of post-S-ICD pocket-related complications that could be explained by sex-based differences in anatomy.

16.
bioRxiv ; 2023 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-37205562

RESUMEN

Background: Repolarization alternans, defined as period-2 oscillation in the repolarization phase of the action potentials, is one of the cornerstones of cardiac electrophysiology as it provides a mechanistic link between cellular dynamics and ventricular fibrillation (VF). Theoretically, higher-order periodicities (e.g., period-4, period-8,...) are expected but have very limited experimental evidence. Methods: We studied explanted human hearts, obtained from the recipients of heart transplantation at the time of surgery, using optical mapping technique with transmembrane voltage-sensitive fluorescent dyes. The hearts were stimulated at an increasing rate until VF was induced. The signals recorded from the right ventricle endocardial surface just before the induction of VF and in the presence of 1:1 conduction were processed using the Principal Component Analysis and a combinatorial algorithm to detect and quantify higher-order dynamics. Results: A prominent and statistically significant 1:4 peak (corresponding to period-4 dynamics) was seen in three of the six studied hearts. Local analysis revealed the spatiotemporal distribution of higher-order periods. Period-4 was localized to temporally stable islands. Higher-order oscillations (period-5, 6, and 8) were transient and primarily occurred in arcs parallel to the activation isochrones. Discussion: We present evidence of higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex-vivo human hearts before VF induction. This result is consistent with the period-doubling route to chaos as a possible mechanism of VF initiation, which complements the concordant to discordant alternans mechanism. The presence of higher-order regions may act as niduses of instability that can degenerate into chaotic fibrillation.

17.
Heart Rhythm ; 20(12): 1669-1673, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37591366

RESUMEN

BACKGROUND: Same-day discharge (SDD) after cardiovascular procedures is rapidly gaining ground. OBJECTIVE: We sought to evaluate the safety of SDD after transvenous lead extraction (TLE). METHODS: We performed a retrospective chart review of patients who underwent elective TLE between January 2020 and October 2021 at our institution. The primary outcome was SDD, and major procedural complications and readmissions within 30 days of the procedure were secondary outcomes. RESULTS: In this analysis of 111 patients who underwent elective TLE, 80 patients (72%) were discharged on the same day (SDD group) while 31 patients (28%) stayed overnight (overnight group). Lead malfunction was the most common indication for TLE in both groups. Patients in the overnight group were more likely to have a lead dwell time of ≤10 years than those in the SDD group (38.7% vs 20% of all leads in each group; P = .042), have laser sheaths used for extraction and a higher number of leads extracted. No major complications were reported in both groups. In a multivariate analysis, lower body mass index and the use of laser sheath during TLE were predictors of overnight stay. Patients who underwent a procedure using advanced extraction techniques were 3.5 times more likely to stay overnight (95% confidence interval 1.27-9.78; P = .016). CONCLUSION: In appropriately selected patients undergoing elective lead extraction, SDD is feasible and safe. Higher body mass index, fewer extracted leads, shorter lead dwell times (<10 years), and less frequent use of laser-powered extraction sheaths were associated with an increased likelihood of SDD.


Asunto(s)
Desfibriladores Implantables , Alta del Paciente , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Desfibriladores Implantables/efectos adversos
18.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1172-1180, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36898953

RESUMEN

BACKGROUND: Class IC antiarrhythmic agents are effective for treating atrial tachyarrhythmias, but their use is restricted in patients with coronary artery disease (CAD). Data on the safety of the use of IC agents in patients with CAD in the absence of recent acute coronary syndromes are lacking. OBJECTIVES: This study sought to evaluate the safety and feasibility of treatment with IC agents in patients with varying degrees of CAD in a large serial, real-world cohort. METHODS: We retrospectively identified all patients at our institution from January 2005 to February 2021 on a IC agent (n = 3,445) and those on sotalol or dofetilide (n = 2,216) as controls, excluding those with a prior history of ventricular tachycardia, implantable cardioverter-defibrillator placement, or nonrevascularized myocardial infarction. Baseline clinical characteristics included degree of CAD (categorized as none, nonobstructive, or obstructive), other comorbid illness, and medication use. Clinical outcomes, including survival, were ascertained. We performed Cox regression analysis to evaluate the effect of IC use on event-free survival across varying degrees of CAD. RESULTS: After adjustment for baseline characteristics, there was an independent association between IC use and improved mortality. However, there was an interaction between IC use and degree of CAD (compared to sotalol) demonstrating poorer event-free survival among those with obstructive coronary disease (HR: 3.80; 95% CI: 1.67-8.67; P = 0.002). CONCLUSIONS: Among select patients with nonobstructive CAD and without a history of ventricular tachycardia, IC agents are not associated with increased mortality. Therefore, these agents may be an option for some patients in whom they are frequently restricted. Further prospective studies are warranted.


Asunto(s)
Enfermedad de la Arteria Coronaria , Taquicardia Ventricular , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Flecainida/efectos adversos , Sotalol/uso terapéutico , Estudios Retrospectivos , Estudios de Factibilidad , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/complicaciones
19.
medRxiv ; 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37662394

RESUMEN

Background: Repolarization alternans, defined as period-2 oscillation in the repolarization phase of the action potentials, provides a mechanistic link between cellular dynamics and ventricular fibrillation (VF). Theoretically, higher-order periodicities (e.g., periods 4, 6, 8,...) are expected but have minimal experimental evidence. Methods: We studied explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Optical mapping of the transmembrane potential was performed after staining the hearts with voltage-sensitive fluorescent dyes. Hearts were stimulated at an increasing rate until VF was induced. Signals recorded from the right ventricle endocardial surface prior to induction of VF and in the presence of 1:1 conduction were processed using the Principal Component Analysis and a combinatorial algorithm to detect and quantify higher-order dynamics. Results were correlated to the underlying electrophysiological characteristics as quantified by restitution curves and conduction velocity. Results: A prominent and statistically significant global 1:4 peak (corresponding to period-4 dynamics) was seen in three of the six studied hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. Discussion: We present evidence of higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex-vivo human hearts. We infer from the independence of the period to the underlying restitution properties that the oscillation of the excitation-contraction coupling and calcium cycling mechanisms is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability that can degenerate into chaotic fibrillation and may provide targets for substrate-based ablation of VF.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA