Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Opt Express ; 31(12): 19754-19765, 2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37381384

RESUMEN

We report a sub-terahertz scattering-type scanning near-field microscope (sub-THz s-SNOM) which uses a 6 mm long metallic tip driven by a quartz tuning fork as the near-field probe. Under continuous-wave illumination by a 94 GHz Gunn diode oscillator, terahertz near-field images are obtained by demodulating the scattered wave at both the fundamental and the second harmonic of the tuning fork oscillation frequency together with the atomic-force-microscope (AFM) image. The terahertz near-field image of a gold grating with a period of 2.3 µm obtained at the fundamental modulation frequency agrees well with the AFM image. The experimental relationship between the signal demodulated at the fundamental frequency and the tip-sample distance is well fitted with the coupled dipole model indicating that the scattered signal from the long probe is mainly contributed by the near-field interaction between the tip and the sample. This near-filed probe scheme using quartz tuning fork can adjust the tip length flexibly to match the wavelength over the entire terahertz frequency range and allows for operation in cryogenic environment.

2.
Opt Express ; 31(6): 10720-10731, 2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-37157613

RESUMEN

To satisfy the demand for broadband and high-sensitivity terahertz detectors, we designed and verified a broadband terahertz detector built with antenna-coupled AlGaN/GaN high-electron-mobility transistors (HEMTs). Eighteen pairs of dipole antennas with different center frequency from 0.24 to 7.4 THz are arrayed into a bow-tie pattern. The corresponding eighteen transistors have common a source and a drain but different gated channels coupled by the corresponding antennas. The photocurrents generated by each gated channel are combined in the drain as the output port. With incoherent terahertz radiation from a hot blackbody in a Fourier-transform spectrometer (FTS), the detector exhibits a continuous response spectrum from 0.2 to 2.0 THz at 298 K and from 0.2 to 4.0 THz at 77 K, respectively. The results agree well with simulations taking into account the silicon lens, antenna and blackbody radiation law. The sensitivity is characterized under coherent terahertz irradiation, the average noise-equivalent power (NEP) is about 188 p W/H z at 298 K and 19 p W/H z at 77 K from 0.2 to 1.1 THz, respectively. A maximum optical responsivity of 0.56 A/W and a minimum NEP of 7.0 p W/H z at 0.74 THz are achieved at 77 K. The blackbody response spectrum is divided by the blackbody radiation intensity to obtain a performance spectrum, which is calibrated by measuring coherence performance from 0.2 to 1.1 THz to evaluate detector performance at frequencies above 1.1 THz. At 298 K, the NEP is about 1.7 n W/H z at 2.0 THz. At 77 K, the NEP is about 3 n W/H z at 4.0 THz. For further improvements in sensitivity and bandwidth, high-bandwidth coupling components, smaller series resistance, smaller gate lengths and high-mobility materials need to be considered.

3.
Opt Express ; 30(24): 42956-42966, 2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36523005

RESUMEN

The foundation for polarization-based terahertz applications is the acquisition of polarization information. To develop an all-electronic terahertz straightforward polarization detection system, in this paper, a terahertz polarization detector based on three antenna-coupled AlGaN/GaN high-electron-mobility transistors (HEMTs) on a single chip is designed and fabricated. The function of the direct polarization detector is proven by measuring the polarization angle of linearly polarized continuous-wave terahertz radiation at 216 GHz. The average deviation and maximum deviation of the measured polarization angle are 3.7 degrees and 10 degrees, respectively. The error comes mainly from the disturbance of the local terahertz field by the interference effect. Simulations locate the sources of interference and guide the further device design and packaging of such kind of direct polarization detectors.

4.
Opt Express ; 28(4): 4911-4920, 2020 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-32121721

RESUMEN

Aiming at the requirement of passive terahertz imaging, we report a high-sensitivity terahertz detector based on an antenna-coupled AlGaN/GaN high-electron-mobility transistor (HEMT) at 77 K without using low-noise terahertz amplifier. The measured optical noise-equivalent power and the noise-equivalent temperature difference of the detector were about 0.3p W/H z and 370 mK in a 200 ms integration time over a bandwidth of 0.7 - 0.9 THz, respectively. By using this detector, we demonstrated passive terahertz imaging of room-temperature objects with signal-to-noise ratio up to 13 dB. Further improvement in the sensitivity may allow passive terahertz imaging using AlGaN/GaN-HEMT at room temperature.

5.
Orthop Surg ; 11(2): 229-235, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30945802

RESUMEN

OBJECTIVES: To explore the safety and efficacy of the enhanced recovery after surgery (ERAS) program for elderly total knee arthroplasty (TKA) patients. METHODS: A prospective controlled study was conducted for patients older than 65 years, who would undergo unilateral TKA with a minimum follow-up of 2 years. Patients were divided into an ERAS group (n = 106) and a traditional group (n = 141) based on the patients' willingness to participate in the ERAS program. Baseline parameters of American Society of Anesthesiologists classification and comorbidity were recorded. Complication, mortality, knee function assessment using knee society score and knee range of motion, and perioperative clinical outcomes were compared between the two groups. RESULTS: There were no significant differences between the two groups in terms of baseline parameters. Although no significant differences were found in postoperative nausea and vomiting, urinary tract infection, deep venous thrombosis, pulmonary embolism, wound delayed healing, superficial infection, and deep infection, there were significantly fewer total complications in the ERAS group (26/106 vs 52/141; P = 0.039). No significant difference was found in short-term mortality (1/106 vs 3/141; P = 0.836) between the two groups. There were no significant differences in preoperative visual analogue scale (VAS), knee society score (KSS), and range of motion (ROM) between the two groups. Lower VAS scores were found in the ERAS group at time of postoperative day (POD) 1 (P = 0.012) and POD 5 (P = 0.020); no significant differences were observed at time of postoperative month (POM) 1 and final follow-up. Higher KSS scores were found in the ERAS group at time of POD 1 (P = 0.013), and POD 5 (P = 0.011), no significant differences were observed at time of POM 1 and final follow-up. Increased ROM degree was found in the ERAS group at time of POD 1 (P = 0.021); no significant differences were observed at time of POD 5, POM 1 and final follow-up. Decreased intraoperative blood loss (P < 0.001), total blood loss (P < 0.001), transfusion rate (P = 0.004), and length of stay (P < 0.001) were found in the ERAS group; no significant differences were found in operative time and hospitalization costs between the two groups. CONCLUSION: The ERAS program is safer and more efficacious in elderly TKA patients compared to the traditional pathway. It could effectively relieve perioperative pain and improve joint function, and reduce blood transfusion, length of stay, and total complications without increasing short-term mortality.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/rehabilitación , Cuidados Posoperatorios/métodos , Anciano , Femenino , Humanos , Masculino , Dimensión del Dolor , Dolor Postoperatorio/epidemiología , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA