Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Scand J Med Sci Sports ; 34(10): e14737, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39350536

RESUMEN

It is not clear if fat oxidation is attenuated at higher exercise intensities, when exercising with a small muscle mass, and therefore, we studied leg fat oxidation during graded one-leg exercise. Ten males (age: 27 ± 2 years, body mass: 82 ± 3 kg, BMI: 24 ± 1 kg m-2, V̇O2max: 49 ± 2 mL min-1 kg-1) performed one-leg exercise at 25% of maximal workload (Wmax) for 30 min, followed by 120-min exercise at 55% Wmax with the contralateral leg, and finally 30-min exercise at 85% Wmax with the first leg. Blood was sampled from an artery and both femoral veins, and blood flow was determined using Doppler ultrasound. Muscle biopsies were obtained before and after 30 min at each workload. One-way RM ANOVA was applied to determine the impact of exercise intensity. Data are expressed as mean ± SEM. From rest through exercise average blood flow (0.4 ± 0.1, 2.1 ± 0.1, 2.6 ± 0.2, 3.7 ± 0.2 L min-1) and oxygen uptake across the leg (0.03 ± 0.01, 0.23 ± 0.02, 0.35 ± 0.03, 0.53 ± 0.04 L min-1) increased with exercise intensity (p < 0.001). Leg RQ (0.76 ± 0.04, 0.86 ± 0.02,0.87 ± 0.01, 0.92 ± 0.01, p < 0.001), leg plasma FA uptake (2 ± 2, 46 ± 8,83 ± 9, 114 ± 16 µmol min-1; p < 0.001) and rate of leg fat oxidation (0.016 ± 0.005, 0.062 ± 0.012, 0.075 ± 0.011, 0.084 ± 0.018 g min-1, p < 0.007) increased with exercise intensity. Muscle-free carnitine content was unchanged from rest at 25% Wmax and decreased after 30 min exercise at 55% and 85% Wmax (17.4 ± 1.6, 16.6 ± 0.7, 14.5 ± 1.2, 10.5 ± 1.0 mmol/kg dry muscle, respectively; p < 0.006). During incremental one-leg exercise, the rate of leg fat oxidation was not attenuated with increasing exercise intensity, probably due to an insufficient muscle metabolic stress response.


Asunto(s)
Ejercicio Físico , Pierna , Músculo Esquelético , Oxidación-Reducción , Consumo de Oxígeno , Flujo Sanguíneo Regional , Humanos , Masculino , Adulto , Ejercicio Físico/fisiología , Consumo de Oxígeno/fisiología , Pierna/fisiología , Músculo Esquelético/fisiología , Músculo Esquelético/metabolismo , Tejido Adiposo/metabolismo , Adulto Joven , Rodilla/fisiología , Ultrasonografía Doppler , Metabolismo de los Lípidos/fisiología
2.
Tissue Eng ; 2(4): 241-53, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-19877956

RESUMEN

Substrate topography in the micrometer range is reviewed as a modifier of the response of cultured cells and of biocompatibility when implanted into tissues. Characterization methods for substrate topography are discussed, including scanning electron microscopy, profilometry, laser scanning, and confocal microscopy. Because of the current technical limitations in reproducing micron-level topographic details, only one method, ion-beam etching, has been found suitable for texturing substrates on nonplanar surfaces.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA