Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiology ; 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38531326

RESUMEN

INTRODUCTION: End-stage renal disease (ESRD) is a major risk factor for cardiovascular morbidity and mortality, which can be partially eliminated by kidney transplantation. Systolic heart failure might be considered as contraindication for kidney transplant although some patients demonstrate myocardial recovery post-transplant. We aim to identify and characterize the phenomenon of reverse myocardial remodelling in kidney transplanted patients. METHODS: The study is a retrospective cohort of patients undergoing kidney transplant between 2016-2019 (n=604) at Rabin Medical Center. Patients were assessed according to availability of two echocardiographic examinations: pre- and post-kidney transplant. The change in estimated ejection fraction (EF) and possible predictors of myocardial recovery were examined. RESULTS: Data of 293 patients was available for the final analysis. Eighty-one (28%) patients had a LVEF improvement equal or above 5%, whereas 36 (12%) patients had a LVEF improvement 10% or more post transplantation. Twenty-five patients (8.5%) had moderate or severe systolic heart failure with LVEF reduced to 40% or less at baseline. 13 of them (52%) had a LVEF improvement of ≥5% and 10 patients (40%) had an improvement of ≥10% in their EF. Cox regression analyses identified female gender as the only independent variable associated with LVEF improvement of at least 10%. Conclusion Renal transplantation might lead to improved LV systolic function in some patients.

2.
Isr Med Assoc J ; 25(5): 324-327, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37245095

RESUMEN

BACKGROUND: Cancellation of transesophageal echocardiography (TEE) tests leads to inefficient use of echocardiography laboratory (echo lab) time and wastes resources. OBJECTIVES: To identify the causes of same-day TEE cancellations in hospitalized patients, to formulate a TEE order screening protocol, and to evaluate its efficacy at implementation. METHODS: We performed a prospective analysis of inpatients referred to a single tertiary hospital echo lab for TEE study by inpatient wards. A comprehensive screening protocol emphasizing active participation of all links directly involved in the chain of inpatient TEE referral was developed and implemented. Comparison of pre- and post-implementation of the new screening protocol on two consecutive periods of 6 months on TEE cancellation rates out of total ordered TEEs stratified by cause categories was performed. RESULTS: : In total, 304 inpatient TEE procedures were ordered during the initial observation period; 54(17.8%) were canceled on the same day. The most common cancellation reasons were equally respiratory distress and patient not in fasted state (20.4% of total cancellations and 3.6% of all scheduled TEEs for each cause). Following implementation of the new screening process, total TEEs ordered (192) and cancelled (16) dropped significantly. A decrease in the rate of each cancellation category was observed, with statistical significance achieved for the overall cancellation rate (8.3% vs. 17.8%, P = 0.003), but not for the individual cancellation categories in split analysis. CONCLUSIONS: A concerted effort to implement a comprehensive screening questionnaire significantly reduced same-day cancellations of scheduled TEEs.


Asunto(s)
Citas y Horarios , Pacientes Internos , Humanos , Israel , Centros de Atención Terciaria , Ecocardiografía Transesofágica , Estudios Retrospectivos
3.
Infection ; 50(1): 57-64, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34089484

RESUMEN

PURPOSE: To evaluate the impact of a multidisciplinary the "Endocarditis Team" (ET) on the course and outcome of infective endocarditis (IE) patients. METHODS: A retrospective before-after study, including hospitalized patients with definite IE, managed before (01.2013-12.2015) and after (01.2016-07.2019) the introduction of an ET. The primary outcomes were defined as 30-day and 1-year mortality and the secondary as conservative vs. invasive strategy, the interval from clinical suspicion of IE to the performance of echocardiography, utilization of multimodality evaluation, time to an invasive procedure, and the duration of hospitalization. RESULTS: Study population included 92 pre-ET and 128 post-ET implementation patients. Baseline characteristics were similar. During the post-ET period compared with pre-ET, we found higher rates of abscesses and extra-cardiac emboli (27.8% vs. 16.3%, p = 0.048); and a higher invasive procedures rate, including lead extraction (15.6% vs. 6.5%, p = 0.035) and noncardiac surgeries (14.8% vs. 6.5%, p = 0.05). Patients managed during the post-ET period had reduced short (8.5% vs. 17.4%, p = 0.048) and long-term mortality (Log-rank = 0.001). In multivariate analysis of risk factors for long-term mortality, period (pre- or post-ET) was not found to be significantly associated with the mortality. CONCLUSION: Establishment of an ET was associated with faster and more intensive evaluation of patients with IE. During the period of an ET activity, mortality rates were reduced compared with the previous period.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Endocarditis/diagnóstico , Endocarditis/epidemiología , Endocarditis/terapia , Mortalidad Hospitalaria , Hospitalización , Humanos , Estudios Retrospectivos , Factores de Riesgo
4.
BMC Cardiovasc Disord ; 22(1): 53, 2022 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-35172724

RESUMEN

BACKGROUND: Right heart catheterization (RHC) and echocardiography are both routinely used for pulmonary artery systolic pressure (PASP) assessment in lung transplantation (LT) candidates, although this is not mandated by current guidelines. We aimed to explore the performance of echocardiographic PASP as an indicator of pulmonary hypertension in LT candidates, in order to assess the necessity of RHC. METHODS: From a retrospective registry of 393 LT candidates undergoing RHC and echocardiography during 2015-2019, patients were assessed for the presence of pulmonary hypertension (PH), defined as mean pulmonary artery pressure (mPAP) above 20 mmHg, according to two methods-echocardiography and RHC. The primary outcome was the correlation between the PASP estimated by echocardiography to that measured by RHC. Secondary outcomes were the prediction value of the echocardiographic evaluation and its accuracy. RESULTS: The mean value of PASP estimated by echocardiography was 49.5 ± 20.0 mmHg, compared to 42.5 ± 18.0 mmHg measured by RHC. The correlation between the two measurements was moderate (Pearson's correlation: r = 0.609, p < 0.01). Echocardiography PASP measurements were moderately discriminative to diagnose PH, with an area under the curve (AUC) of 0.72 (95% CI 0.66-0.77). Echocardiographic overestimation of PASP of more than 10 mmHg was found in 35.0% of the patients, and underestimation was found in 11.6% of the patients. CONCLUSION: In the pre-surgical evaluation of LT candidates, echocardiographic estimation of PASP had moderate correlation and limited accuracy compared to the PASP measured by RHC. We thus recommend performing routine RHC to all LT candidates, regardless of the echocardiographic estimation of PASP.


Asunto(s)
Presión Arterial , Cateterismo Cardíaco , Ecocardiografía , Hipertensión Pulmonar/diagnóstico por imagen , Trasplante de Pulmón , Arteria Pulmonar/diagnóstico por imagen , Anciano , Femenino , Humanos , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Arteria Pulmonar/fisiopatología , Sistema de Registros , Reproducibilidad de los Resultados , Estudios Retrospectivos
5.
Catheter Cardiovasc Interv ; 98(5): E758-E767, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33682347

RESUMEN

OBJECTIVES: Right ventricular (RV) dysfunction and tricuspid regurgitation (TR) are associated with adverse outcomes in severe aortic stenosis (AS) patients. Our aim was to evaluate the association between ≥moderate TR and RV dysfunction on long-term mortality following transcatheter aortic valve replacement (TAVR). METHODS: A retrospective analysis of the Israeli multicenter TAVR registry among 4,344 consecutive patients, with all-cause mortality as the main outcome measure. RESULTS: Echocardiographic assessment of TR grade and RV dysfunction was available for 3,733 and 1,850 patients, of whom ≥moderate TR and RV dysfunction was noted for 478(13%) and 78(4%), respectively. The mean follow-up time was 2.9 ± 2.3 years. In univariate models, ≥Moderate TR and ≥moderate RV dysfunction were associated with increased long-term mortality (HR 1.45, 95% CI 1.24-1.69, p < .001 and HR 1.73, 95% CI 1.21-2.47, p = 0.003, respectively). These finding did not remained significant after adjusting to echocardiographic parameters. A subset of patients with no improvement in RV function had the highest long-term mortality risk (HR 3.3, 95% CI 1.95-5.7, p < .001). CONCLUSION: When adjusted to multiple echocardiographic characteristics baseline ≥Moderate TR and ≥moderate RV dysfunction were not associated with long-term mortality following TAVR. Persistent RV dysfunction following TAVR was associated with the highest risk for mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología
6.
Echocardiography ; 38(12): 2016-2024, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34854128

RESUMEN

BACKGROUND: In view of inconsistencies in threshold values of severe aortic stenosis (AS) hemodynamic indices, it is unclear what is the relative contribution of each variable in a binary classification of AS based on aortic valve replacement (AVR) indication. We aimed to assess relative discriminative value and optimal threshold of each constituent hemodynamic parameter for this classification and confirm additional prognostic value. METHODS: Echocardiography studies of 168 patients with ≥ moderate AS were included. AS types were dichotomized into Group-A, comprising moderate and Normal-Flow Low-Gradient (NFLG), and Group-B, comprising High-Gradient(HG), Low Ejection Fraction Low-Flow Low-Gradient(Low EF-LFLG), and Paradoxical Low-Flow Low-Gradient(PLFLG) AS. Aortic valve area (AVA), Doppler velocity index (DVI), peak aortic velocity, mean gradient, stroke volume index and transaortic flow rate(TFR) were assessed for A/B Group discrimination value and optimal thresholds were determined. Dichotomized values were assessed for predictive value for AVR or death. RESULTS: C-statistic values for binary AS classification was .74-.9 for the tested variables. AVA and DVI featured the highest score, and SVI the lowest one. AVA≤.81 cm2 and DVI≤.249 had 87.6% and 86% respective sensitivity for Group B patients, and a similar specificity of 80.9%. During a mean follow-up of 9.1±10.1 months, each of the tested dichotomized variables except for SVI predicted AVR or death on multivariate analysis. CONCLUSION: An AVA value ≤.81 cm2 or a DVI ≤ .249 threshold carry the highest discriminative value for severe AS in patients with aortic stenosis, translating into an independent prognostic value, and can be helpful in making clinical decisions.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Humanos , Índice de Severidad de la Enfermedad , Volumen Sistólico
7.
Isr Med Assoc J ; 21(5): 308-313, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31140220

RESUMEN

BACKGROUND: The MitraClip procedure is becoming an acceptable alternative for high-risk patients with mitral regurgitation (MR) due to functional (FMR) or degenerative (DMR) disease and suitable mitral anatomy. OBJECTIVES: To evaluate the results of MitraClip at our institute in carefully selected patients. METHODS: We conducted a retrospective analysis of medical records and echocardiography data from January 2012 to December 2017. RESULTS: A total of 39 MitraClip procedures in 37 patients (aged 75 ± 12 years, 9 women) was performed. Twenty-four patients presented with FMR, 12 with DMR, and 1 with combined pathology. One-day post-procedure MR was moderate to low in 86.1% of patients, with immediate device success in 88.8%. MR at 1 year was moderate to low in 79% at 1 year. Survival at 1 year was 86% and at 2 years 69.4%. Peri-procedural (< 1 week) death and MitraClip failure occurred in one and three patients, respectively. New York Heart Association score improved to class 1 or 2 in 37% of patients at 1 year vs. one patient at baseline. Post-procedural systolic pulmonary pressure was reduced from 53 (range 48-65) to 43 (range 36-52) mmHg at 1 month with a subsequent plateau at follow-up, to 41 (34-57) mmHg at 6 months, and to 47 (38-50) at 12 months. CONCLUSIONS: MitraClip in severe MR resulted in modest improvement in functional status and pulmonary pressure with a small risk of immediate procedural complications. Outcomes are encouraging considering the natural course of MR and the risks of surgical intervention.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Complicaciones Posoperatorias , Anciano , Anciano de 80 o más Años , Ecocardiografía/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Israel , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Evaluación de Resultado en la Atención de Salud , Rendimiento Físico Funcional , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Diseño de Prótesis , Presión Esfenoidal Pulmonar , Ajuste de Riesgo , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
8.
Catheter Cardiovasc Interv ; 90(7): 1175-1182, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28544120

RESUMEN

OBJECTIVE: To evaluate the effect of baseline aortic valve gradient (AVG) both as a continuous and a categorical variable on mortality in patients undergoing transcatheter aortic valve replacement (TAVR), focusing on the high-gradient severe aortic stenosis (AS) patients. BACKGROUND: Identifying new predictors of mortality in the TAVR population can help refine risk stratification and improve the patient selection process for this procedure. So far, AVG has mainly been studied as a categorical variable and there is a paucity of data on its prognostic value as a continuous variable, especially in patients with high AVG AS, who constitute the majority of patients referred for TAVR. METHODS: We analyzed data on 1,224 consecutive symptomatic severe AS patients, who underwent TAVR at 3 centers. The relation between pre-TAVR AVG and mortality was evaluated among all patients and in patients with high AVGs (mean AVG ≥40 mm Hg) using the Cox proportional hazard model adjusting for multiple variables. RESULTS: During a mean follow-up of 1.8 years, baseline AVG was inversely associated with mortality in the entire cohort and in patients with high AVG AS. By multivariable analysis, patients with mean AVG 40-60 mm Hg and >60 mm Hg had a respective 38% (P = 0.010) and 61% (P < 0.001) reduction in mortality compared to patients with mean AVG <40 mm Hg. Every 10 mm Hg increase in mean AVG was associated with 20% reduction in mortality (P < 0.001). Analyses among patients with high (mean AVG >40 mm Hg) and very high AVG AS (mean AVG >60 mm Hg) yielded similar results (HR = 0.88, P = 0.031, and HR = 0.80, P = 0.019, per 10 mm Hg increase in AVG, respectively). Using peak AVGs and an analysis restricted to patients without reduced ejection fraction yielded consistent results. CONCLUSIONS: Baseline AVGs show an inverse association with mortality post-TAVR. These results were consistent also in patients with high-gradient AS, suggesting that AVG can be used to identify patients most likely to benefit from TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Distribución de Chi-Cuadrado , Femenino , Humanos , Israel , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Modelos de Riesgos Proporcionales , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
10.
J Heart Valve Dis ; 26(5): 509-517, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-29762919

RESUMEN

BACKGROUND: Transthoracic echocardiography (TTE) is the standard method for evaluating the severity of aortic stenosis (AS), while transesophageal echocardiography (TEE) is useful for morphologic characterization. The study aim was to assess the impact of complementary TEE to TTE in refining hemodynamic assessment of AS severity. METHODS: A retrospective analysis was conducted of sequential TTE and TEE studies performed in 100 patients with moderate or severe AS confirmed on prior TTE. The left ventricular outflow tract (LVOT) velocity-time-integral (VTI1) and the aortic valve velocity-time integral (VTI2) were measured for both modalities. The highest values of VTI1 and VTI2 and mean gradients and peak velocities were selected from the sequential TTE/TEE study for indexed aortic valve area (AVAi) calculation and AS severity determination through an integrated assessment. RESULTS: AVAi determined by TTE was not significantly different from that determined by TEE (mean difference -0.008 cm2; p = 0.38). The dimensionless velocity index (DVI) was higher when assessed by TTE than by TEE (mean difference 0.0126 ± 0.04; p = 0.003). Using the integrated AS assessment, six of 13 patients with a TTE-based diagnosis of moderate AS were re-classified as severe AS. A slight lowering of the recommended TTE-derived DVI threshold for severe AS, from 0.25 to 0.24, improved the ability to discriminate moderate versus severe AS, as determined by the integrated assessment. CONCLUSIONS: TEE integrated with TTE may improve the detection of severe AS, particularly in patients with moderate AS criteria assessed by TTE, but with a DVI ratio ≤0.24.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos , Anciano , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Investigación sobre la Eficacia Comparativa , Precisión de la Medición Dimensional , Femenino , Hemodinámica/fisiología , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
11.
Isr Med Assoc J ; 19(3): 156-159, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28457092

RESUMEN

BACKGROUND: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery. OBJECTIVES: To report the multicenter TVIV experience in Israel. METHODS: We approached multiple centers and collected data regarding seven TVIV cases. RESULTS: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up. CONCLUSIONS: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Catéteres Cardíacos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Válvula Tricúspide , Insuficiencia de la Válvula Tricúspide/cirugía , Estenosis de la Válvula Tricúspide/cirugía
12.
Cardiology ; 134(2): 128-35, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26953820

RESUMEN

OBJECTIVES: To explore the relation between the baseline aortic valve gradient (AVG) as a continuous variable and clinical outcomes following transcatheter aortic valve implantation (TAVI) in general and specifically in patients with high-gradient aortic stenosis (AS). METHODS: We reviewed 317 consecutive patients who underwent TAVI at our institution. We investigated the relation between AVG as a continuous/categorical variable and outcome among all patients and in patients without low-flow low-gradient AS, using the Cox proportional hazard model adjusting for multiple prognostic variables. RESULTS: Patients had a peak AVG of 79.9 ± 22.8 mm Hg (mean 50.5 ±15.7). During a mean follow-up of 2.7 years, AVG was inversely associated with mortality and mortality or cardiac hospitalization. Every 10-mm-Hg increase in peak AVG was associated with 18% reduction in mortality (p = 0.003) and 19% reduction in mortality/cardiac hospitalization (p < 0.001). Every 10-mm-Hg increase in mean AVG was associated with a 24% reduction in both outcomes (p = 0.005 and p < 0.001). Subgroup analysis of patients with left-ventricular ejection fraction >40% or peak AVG >64 mm Hg yielded similar results. CONCLUSIONS: Mean and peak baseline AVGs are directly associated with improved outcomes after TAVI; AVG can be used to select the patients most likely to benefit from TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco , Mortalidad Hospitalaria , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Modelos de Riesgos Proporcionales , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
13.
J Heart Valve Dis ; 25(2): 157-161, 2016 03.
Artículo en Inglés | MEDLINE | ID: mdl-27989059

RESUMEN

BACKGROUND: Although significant late tricuspid regurgitation (TR) may develop after surgery for degenerative mitral regurgitation (MR), the use of routine tricuspid annuloplasty is debatable. The study aim was to determine the prevalence and predictors of significant late TR after surgery for degenerative MR. METHODS: A total of 112 patients who had undergone surgery for degenerative MR without concomitant tricuspid valve repair (average follow up 7.7 ± 4.0 years) was studied retrospectively. The prevalence of post-surgical TR and predictors of progression were determined. RESULTS: The majority of patients (97%) had non-significant TR (less than moderate) prior to surgery, although an overall trend of progression towards significant TR (grades 2 or 3) was noted in 17 patients (p = 0.0006). Of the 18 patients (16%) with late postoperative significant TR, only nine (8%) had severe TR with only a single referral to surgery. New-onset post-surgical atrial fibrillation was more common in patients who developed late significant TR (p = 0.002). Multivariate analysis of the pre-surgery variables, age >65 years and left ventricular dysfunction were shown to be independent predictors of late functional TR. CONCLUSIONS: Significant progression in TR after surgery for degenerative MR was rare in this patient cohort. The impact of older age and left ventricular dysfunction at the time of surgery showed a strong association with post-surgical atrial fibrillation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anuloplastia de la Válvula Mitral/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Insuficiencia de la Válvula Tricúspide/epidemiología , Válvula Tricúspide/fisiopatología , Factores de Edad , Anciano , Fibrilación Atrial/epidemiología , Supervivencia sin Enfermedad , Femenino , Humanos , Israel/epidemiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/fisiopatología , Análisis Multivariante , Prevalencia , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/fisiopatología
14.
J Heart Valve Dis ; 24(3): 345-52, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26901911

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The percutaneous approach for a failed bioprosthetic valve is an emerging alternative to redo-valve surgery in patients at high surgical risk. The study aim was to describe the treatment of patients with structural bioprosthetic valve deterioration, using the valve-in-valve technique. METHODS: A total of 33 consecutive patients with symptomatic structural bioprosthetic valve deterioration was treated at the authors' institution, using the valve-in-valve technique. RESULTS: The valve-in-valve procedure in the aortic position was performed in 23 patients (mean age 81.4 ± 5.9 years; mean STS score 9.6 ± 5.4). The self-expandable and balloon-expandable devices were used in 21 cases (91.3%) and two cases (8.7%), respectively. Procedures were performed via the trans-femoral, trans-axillary and trans-apical routes in 18 (78.2%), three (13%) and two (8.7%) cases, respectively. After the procedure, all patients were in NYHA class I/II. Survival rates were 95.6% at the one-year follow up. The valve-in-valve procedure in the mitral position was performed in 10 patients (mean age 73.6 ± 15 years; mean STS score 7.7 ± 4.1). All procedures were performed using the balloon-expandable device via the trans-apical route. The composite end point of device success was achieved in all patients. Survival rates were 100% and 75% at one month and two years' follow up, respectively. A single valve-in-valve implantation within a failed tricuspid bioprosthetic valve was also successfully performed. CONCLUSION: In the authors' experience, the valve-in-valve technique for the treatment of a wide range of bioprosthetic valve deterioration modes of failure in different valve positions is safe and very effective.


Asunto(s)
Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Válvulas Cardíacas/cirugía , Anciano , Anciano de 80 o más Años , Valvuloplastia con Balón , Femenino , Humanos , Masculino , Falla de Prótesis , Reoperación
15.
J Heart Valve Dis ; 24(3): 272-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26901894

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The dynamics of left ventricular mass (LVM) regression following the relief of chronic left ventricular pressure overload are prone to variation. The study aim was to identify determinants of LVM regression following transcatheter aortic valve implantation (TAVI). METHODS: A total of 134 patients undergoing TAVI was identified. A retrospective analysis was performed of LVM indexed to body surface area (LVMi), calculated using transthoracic echocardiography at baseline and at six to 12 months post-TAVI. RESULTS: At six to 12 months after TAVI, there was a significant reduction in mean LVMi (from 118.2 ± 26.67 g/m2 to 103.4 ± 27.07 g/m2; p < 0.001) driven by a decrease in left ventricular wall thickness. The relative wall thickness (RWT) was decreased (0.54 ± 0.10 cm versus 0.51 ± 0.09 cm; p = 0.006), whereas the prevalence of concentric remodeling (RWT ≥ 0.42) remained unchanged (85.1% versus 80.6%; p = 0.3). However, 47 patients (35.1%) demonstrated significant LVMi regression, but had a lower baseline LVMi than patients who demonstrated significant regression (109.8 ± 25.8 g/m2 versus 122 ± 26.1 g/m2; p = 0.008) but had otherwise similar characteristics. A greater magnitude of LVMi reduction was associated with a greater baseline LVMi (r = 0.39; p < 0.001), where patients with LVMi in the highest quartile had the most substantial reduction in LVMi (p < 0.001). Multivariable analysis identified pre-TAVI LVMi as the sole independent predictor of LVMi regression at six to 12 months post-TAVI (P = 0.45; 95% confidence interval 0.255-0.534; p < 0.001). CONCLUSION: LVM regression at six to months post-TAVI was variable, with about one-third of patients not showing a significant regression. Only baseline LVM predicted LVM regression; patients with a higher baseline LVM demonstrated a greater regression.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/terapia , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Humanos , Hipertrofia Ventricular Izquierda/etiología , Masculino , Periodo Posoperatorio , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
16.
J Heart Valve Dis ; 24(4): 439-44, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26897813

RESUMEN

BACKGROUND AND AIM OF THE STUDY: In patients with aortic stenosis, mitral regurgitation (MR) is a common finding. Little is known regarding outcomes of MR in patients undergoing transcatheter aortic valve implantation (TAVI). The study aim was to characterize the short- and mid-term impact of the TAVI procedure on MR grade. METHODS: A total of 261 patients (59% females; mean age 82.1 +/- 6.9 years) undergoing TAVI was assessed for rates of significant MR and the severity of MR at baseline, and at one month and six months after the procedure. RESULTS: In patients with moderate MR or above at baseline (n = 26, 10% of the cohort), there was a mean reduction in grade of 1.5 +/- 1.1 and 1.8 +/- 1.4 after one and six months, respectively (p < 0.01). Reduction in MR grade (1+) at six months was identified in 54.1% (40/74) of patients with mild-moderate MR or greater, and in 88.5% (23/26) of those with moderate MR or above, and was associated with an improved NYHA functional class (correlation coefficient r = -0.294, p < 0.001). Multivariate analysis identified low pulmonary pressure and tricuspid regurgitation as independent predictors of improvements in MR. CONCLUSION: Among the present cohort of patients undergoing TAVI, those with MR at baseline showed an improvement in the severity of their MR. Patients with moderate MR regurgitation or above demonstrated the greatest improvement.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Insuficiencia de la Válvula Mitral/fisiopatología , Válvula Mitral/fisiopatología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/instrumentación , Distribución de Chi-Cuadrado , Ecocardiografía Doppler en Color , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Israel , Modelos Lineales , Modelos Logísticos , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Análisis Multivariante , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Inducción de Remisión , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
18.
Harefuah ; 154(7): 423-5, 470, 2015 Jul.
Artículo en Hebreo | MEDLINE | ID: mdl-26380459

RESUMEN

Mitral regurgitation is a common disease in patients with cardiomyopathies, constituting poor prognosis when present. In patients with an increased risk for surgery, a minimally-invasive, percutaneous procedure currently exists, in the form of an edge-to-edge repair technique using the MitraClip device. This approach allows for great flexibility in specific situations, such as in the addition of another clip when necessary, either during the procedure or after a follow-up period. The following case study depicts the course of therapy for a patient with ischemic cardiomyopathy and severe bi-ventricular failure. The patient was implanted with a MitraClip device five months before the current event, and now presents with clinical deterioration, and a renewed mitral valve insufficiency.


Asunto(s)
Insuficiencia de la Válvula Mitral/cirugía , Isquemia Miocárdica/fisiopatología , Instrumentos Quirúrgicos , Anciano , Diseño de Equipo , Humanos , Masculino , Recurrencia , Índice de Severidad de la Enfermedad
19.
Cardiology ; 127(4): 227-35, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24481462

RESUMEN

OBJECTIVE: Transcatheter aortic valve implantation (TAVI) is occasionally associated with stroke and silent cerebral ischemia, which may affect cognitive and functional performance. The aim of this study was to evaluate the changes in cognitive performance and functional status following TAVI. METHODS: We performed a comprehensive prospective functional, cognitive and quality of life (QOL) evaluation in consecutive patients who underwent TAVI using the CoreValve device (Medtronic Inc.). The evaluation was performed at baseline and 1 month after the procedure and included the 36-item Short-Form Health Survey for QOL assessment, Mini-Mental State Examination (MMSE), quantitative clock drawing test (Rouleau), color trails test, Cognistat evaluation, Barthel Index and Duke Activity Status Index. RESULTS: A total of 36 patients completed the full pre- and post-TAVI evaluation. Mean age was 82.2 ± 4.2 years (52.8% men); 94.5% of patients had low functional class (New York Heart Association III/IV), and 13.9% had prior stroke. After the procedure, all patients had improved functional status and valve hemodynamics. At 1 month, there was a significant improvement in the MMSE and Cognistat evaluations (from 25.9 ± 3.3 to 27.6 ± 2.4, p < 0.001, and from 5 ± 1 to 5.7 ± 0.7, p = 0.001, respectively). CONCLUSIONS: Our preliminary results of a comprehensive assessment of patients undergoing TAVI indicate favorable results for both functional performance and cognitive function early after the procedure.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Trastornos del Conocimiento/etiología , Cognición , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Procedimientos Endovasculares/efectos adversos , Femenino , Estado de Salud , Humanos , Masculino , Estudios Prospectivos , Calidad de Vida
20.
Kidney Med ; 6(5): 100808, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38628464

RESUMEN

Rationale & Objective: Kidney function can be adversely affected by significant tricuspid regurgitation (TR) owing to effects on cardiac output and systemic venous congestion. However, the impact of significant TR on short- and long-term kidney function following a kidney transplant remains uncertain. Study Design: Retrospective observational cohort. Setting & Participants: Kidney transplant recipients from a single center between 2016 and 2019. Exposure: Significant TR, defined by at least moderate regurgitation, on echocardiogram before kidney transplantation. Outcomes: Primary end points included the estimated glomerular filtration rate (eGFR) at the following 3 time points: 2 weeks, 3 months, and 1 year after transplantation. Secondary end points included major adverse cardiac events including nonfatal myocardial infarction, all-cause mortality, and hospitalization owing to cardiovascular disease. Analytical Approach: Propensity score matching was performed in 1:3 ratio between patients treated with significant TR and controls, within a caliper 0.05 standard deviation of the propensity score, to analyze for the primary end point. Results: Among 557 kidney transplant recipients, 26 (5%) exhibited significant TR pretransplantation. According to propensity score matching analysis, with 1:3 ratio between 24 patients with significant TR and 72 controls, the presence of significant TR was associated with a lower eGFR posttransplantation. Specifically, the mean eGFR was 41.2 mL/min/1.73 m2 compared to 53.3 mL/min/1.73 m2 at 2 weeks (P < 0.01), 50.0 mL/min/1.73 m2 versus 60.3 mL/min/1.73 m2 at 3 months (P < 0.01), and 49.4 mL/min/1.73 m2 versus 61.2 mL/min/1.73 m2 at 1 year (P < 0.01). Delayed graft function was observed in 41.7% of the patients with significant TR compared to 12.5% of those without significant TR (P < 0.01). No patients with significant TR required dialysis after 1 year. 1-year major adverse cardiac events were nonsignificantly higher among patients with significant TR (20.8% vs 8.1%; P = 0.16). Limitations: Retrospective design and relatively small TR population. Conclusions: The presence of significant TR among kidney transplant recipients was associated with a lower eGFR at 2 weeks, 3 months, and 1 year following transplant, although all remained dialysis independent at 1 year.


Significant tricuspid regurgitation (TR) is associated with increased mortality rates and kidney failure, but its impact on kidney transplant recipients is poorly investigated. We examined how significant TR diagnosed pretransplantation affects kidney function within the first posttransplant year in a retrospective cohort study. Among 24 patients with significant TR, there was a consistent pattern of lower kidney function at 2 weeks, 3 months, and 1 year following transplantation, compared to 72 matched controls based on a propensity score. Results were statistically significant at all time points within the first year after transplant. These findings suggest that selected individuals with significant TR are able to undergo successful kidney transplantation, although with worse kidney function following transplantation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA