RESUMEN
Friction is the dominant factor restricting tracking accuracy and machining surface quality in mechanical systems such as machine tool feed-drive. Hence, friction modeling and compensation is an important method in accurate tracking control of CNC machine tools used for welding, 3D printing, and milling, etc. Many static and dynamic friction models have been proposed to compensate for frictional effects to reduce the tracking error in the desired trajectory and to improve the surface quality. However, most of them focus on the friction characteristics of the pre-sliding zone and low-speed sliding regions. These models do not fully describe friction in the case of insufficient lubrication or high acceleration and deceleration in machine tool systems. This paper presents a new nonlinear friction model that includes the typical Coulomb-Viscous friction, a nonlinear periodic harmonic friction term for describing the lead screw property in insufficient lubrication, and a functional component of acceleration for describing the friction lag caused by the acceleration and deceleration of the system. Experiments were conducted to compare the friction compensation performance between the proposed and the conventional friction models. Experimental results indicate that the root mean square and maximum absolute tracking error can be significantly reduced after applying the proposed friction model.
RESUMEN
OBJECTIVES: To explore the effects of different test positions on quantitative muscle strength of wrist and finger flexor muscle groups and to establish a standardized muscle strength test protocol for each muscle group. METHODS: Forty healthy subjects (12 males and 28 females) were recruited. A portable digital quantitative muscle strength tester, Micro FET2TM, was used to measure the flexor muscle strength of each finger and the wrist joint at the 30° extension, 0° neutral, and 30° flexion, respectively. Palmar abduction strength of the thumb was measured at 30° and 60°, respectively. Ten subjects were randomly selected from the 40 subjects, and the quantitative muscle strength of each muscle group was tested again by the same operator after an interval of 10 to 15 days. RESULTS: Except for the fact that in males, there was no significant difference in flexor muscle strength of thumb and wrist joint between 30° of wrist extension and neutral 0° position, the muscle strength of the other fingers flexion and wrist palmar flexor showed the following characteristicsï¼30° of wrist extension > neutral 0° position > 30° of flexion, and the PAST was 30°>60°; The flexor muscle strength of all the subjects was thumb > index finger > middle finger > ring finger > little finger; All muscle strength values of male were greater than those of female, and the difference was statistically significant (P<0.05); There was no significant difference between the left and right side muscle strength values of all subjects (P>0.05). The reliability of muscle strength values measured at different times in 10 subjects was good. CONCLUSIONS: The quantitative muscle strength of each muscle group of the hand and wrist is affected by the test position, and a standardized and uniformed test position should be adopted in the actual identification. Micro FET2TM has good reliability for hand and wrist quantitative muscle strength testing. The 30° extension of the wrist can be used as the best standardized test position for the flexion muscle strength of each finger and wrist joint. The 30° position can be used as the best standardized test position for PAST.
Asunto(s)
Dedos , Fuerza Muscular , Músculo Esquelético , Articulación de la Muñeca , Humanos , Masculino , Femenino , Dedos/fisiología , Músculo Esquelético/fisiología , Adulto , Fuerza Muscular/fisiología , Adulto Joven , Articulación de la Muñeca/fisiología , Muñeca/fisiología , Fuerza de la Mano/fisiología , Rango del Movimiento Articular/fisiología , Postura/fisiología , Dinamómetro de Fuerza Muscular , Pulgar/fisiología , Articulaciones de los Dedos/fisiología , Reproducibilidad de los ResultadosRESUMEN
OBJECTIVES: To study the virtual reality-pattern visual evoked potential (VR-PVEP) P100 waveform characteristics of monocular visual impairment with different impaired degrees under simultaneous binocular perception and monocular stimulations. METHODS: A total of 55 young volunteers with normal vision (using decimal recording method, far vision ≥0.8 and near vision ≥0.5) were selected to simulate three groups of monocular refractive visual impairment by interpolation method. The sum of near and far vision ≤0.2 was Group A, the severe visual impairment group; the sum of near and far vision <0.8 was Group B, the moderate visual impairment group; and the sum of near and far vision ≥0.8 was Group C, the mild visual impairment group. The volunteers' binocular normal visions were set as the control group. The VR-PVEP P100 peak times measured by simultaneous binocular perception and monocular stimulation were compared at four spatial frequencies 16×16, 24×24, 32×32 and 64×64. RESULTS: In Group A, the differences between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at 24×24, 32×32 and 64×64 spatial frequencies were statistically significant (P<0.05); and the P100 peak time of normal vision eyes at 64×64 spatial frequency was significantly different from the simulant visual impairment eyes (P<0.05). In Group B, the differences between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at 16×16, 24×24 and 64×64 spatial frequencies were statistically significant (P<0.05); and the P100 peak time of normal vision eyes at 64×64 spatial frequency was significantly different from the simulant visual impairment eyes (P<0.05). In Group C, there was no significant difference between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at all spatial frequencies (P>0.05). There was no significant difference in the P100 peak times measured at all spatial frequencies between simulant visual impairment eyes and simultaneous binocular perception in the control group (P>0.05). CONCLUSIONS: VR-PVEP can be used for visual acuity evaluation of patients with severe and moderate monocular visual impairment, which can reflect the visual impairment degree caused by ametropia. VR-PVEP has application value in the objective evaluation of visual function and forensic clinical identification.
Asunto(s)
Potenciales Evocados Visuales , Realidad Virtual , Humanos , Visión Ocular , Visión Binocular/fisiología , Trastornos de la Visión/diagnósticoRESUMEN
Our study seeks to obtain data which help to assess the impacts and related mechanisms of microRNA miR-509-3p in hepatocellular carcinoma (HCC). We found that the expression of miR-509-3p was down-regulated and Twist was up-regulated in HCC tissues and cell lines (HepG2, HCCLM3, Bel7402, and SMMC7721) compared with the adjacent normal tissues and normal human hepatocyte (L02). Moreover, cell proliferation, invasion, migration and epithelial-mesenchymal transition (EMT) in HepG2 and HCCLM3 cells were appeared to be markedly suppressed by overexpressed miR-509-3p. Overexpression of miR-509-3p also performed inhibition of the growth and metastasis in vivo. In addition, miR-509-3p could target and inhibit Twist expression, and it could further reverse the tumor promotion by Twist in HCC. All in all, miR-509-3p overexpression causes inhibition of the proliferation, migration, invasion and EMT of HCC cells by negatively regulating Twist, thereby suppressing HCC development and metastasis.
Asunto(s)
Carcinoma Hepatocelular , Transición Epitelial-Mesenquimal/genética , Neoplasias Hepáticas , MicroARNs , Animales , Carcinoma Hepatocelular/genética , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/patología , Línea Celular Tumoral , Proliferación Celular/genética , Transición Epitelial-Mesenquimal/efectos de los fármacos , Humanos , Hígado/metabolismo , Hígado/patología , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/patología , Masculino , Ratones , Ratones Desnudos , MicroARNs/genética , MicroARNs/metabolismo , MicroARNs/farmacología , Proteínas Nucleares/genética , Proteínas Nucleares/metabolismo , Proteína 1 Relacionada con Twist/genética , Proteína 1 Relacionada con Twist/metabolismoRESUMEN
Detection of the vitality of wounds is essential in forensic practice. The present study used Illumina RNA-seq technology to determine gene expression profiles in contused mouse skin. In obtained high quality sequencing reads, the reads were mapped onto a reference transcriptome (Mus_musculus.GRCm38.83). The results revealed that there were 659 up-regulated and 996 down-regulated differentially expressed genes (DEGs) in contused mouse skin. The DEGs were further analyzed using the Gene Ontology and the Kyoto Encyclopedia of Genes and Genomes databases. Genes from different functional categories and signalling pathways were enriched, including the immune system process, immune response, defense response, cytokine-cytokine receptor interaction, complement and coagulation cascades and chemokine signalling pathway. Expression patterns of 11 DEGs were verified by RT-qPCR in mice skins. In addition, alterations of five DEGs were also analyzed in postmortem human wound samples. The results were in concordance with the results of RNA-seq. These findings suggest that RNA-seq is a powerful tool to reveal DEGs as potential markers for vital reaction in terms of forensic practices.