Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Physiol ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38843407

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) has been characterized by lower blood flow to exercising limbs and lower peak oxygen utilization ( V ̇ O 2 ${{\dot{V}}_{{{{\mathrm{O}}}_{\mathrm{2}}}}}$ ), possibly associated with disease-related changes in sympathetic (α-adrenergic) signaling. Thus, in seven patients with HFpEF (70 ± 6 years, 3 female/4 male) and seven controls (CON) (66 ± 3 years, 3 female/4 male), we examined changes (%Δ) in leg blood flow (LBF, Doppler ultrasound) and leg V ̇ O 2 ${{\dot{V}}_{{{{\mathrm{O}}}_{\mathrm{2}}}}}$ to intra-arterial infusion of phentolamine (PHEN, α-adrenergic antagonist) or phenylephrine (PE, α1-adrenergic agonist) at rest and during single-leg knee-extension exercise (0, 5 and 10 W). At rest, the PHEN-induced increase in LBF was not different between groups, but PE-induced reductions in LBF were lower in HFpEF (-16% ± 4% vs. -26% ± 5%, HFpEF vs. CON; P < 0.05). During exercise, the PHEN-induced increase in LBF was greater in HFpEF at 10 W (16% ± 8% vs. 8% ± 5%; P < 0.05). PHEN increased leg V ̇ O 2 ${{\dot{V}}_{{{{\mathrm{O}}}_{\mathrm{2}}}}}$ in HFpEF (10% ± 3%, 11% ± 6%, 15% ± 7% at 0, 5 and 10 W; P < 0.05) but not in controls (-1% ± 9%, -4% ± 2%, -1% ± 5%; P = 0.24). The 'magnitude of sympatholysis' (PE-induced %Δ LBF at rest - PE-induced %Δ LBF during exercise) was lower in patients with HFpEF (-6% ± 4%, -6% ± 6%, -7% ± 5% vs. -13% ± 6%, -17% ± 5%, -20% ± 5% at 0, 5 and 10 W; P < 0.05) and was positively related to LBF, leg oxygen delivery, leg V ̇ O 2 ${{\dot{V}}_{{{{\mathrm{O}}}_{\mathrm{2}}}}}$ , and the PHEN-induced increase in LBF (P < 0.05). Together, these data indicate that excessive α-adrenergic vasoconstriction restrains blood flow and limits V ̇ O 2 ${{\dot{V}}_{{{{\mathrm{O}}}_{\mathrm{2}}}}}$ of the exercising leg in patients with HFpEF, and is related to impaired functional sympatholysis in this patient group. KEY POINTS: Sympathetic (α-adrenergic)-mediated vasoconstriction is exaggerated during exercise in patients with heart failure with preserved ejection fraction (HFpEF), which may contribute to limitations of blood flow, oxygen delivery and oxygen utilization in the exercising muscle. The ability to adequately attenuate α1-adrenergic vasoconstriction (i.e. functional sympatholysis) within the vasculature of the exercising muscle is impaired in patients with HFpEF. These observations extend our current understanding of HFpEF pathophysiology by implicating excessive α-adrenergic restraint and impaired functional sympatholysis as important contributors to disease-related impairments in exercising muscle blood flow and oxygen utilization in these patients.

2.
J Clin Monit Comput ; 37(1): 21-27, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35648329

RESUMEN

PURPOSE: Urine oxygen partial pressure (PuO2) may be useful for assessing acute kidney injury (AKI) risk. The primary purpose of this study was to quantify the ability of a novel urinary oxygen monitoring system to make real-time PuO2 measurements intraoperatively which depends on adequate urine flow. We hypothesized that PuO2 data could be acquired with enough temporal resolution to provide real-time information in both AKI and non-AKI patients. METHODS: PuO2 and urine flow were analyzed in 86 cardiac surgery patients. PuO2 data associated with low (< 0.5 ml/kg/hr) or retrograde urine flow were discarded. Patients were excluded if > 70% of their data were discarded during the respective periods, i.e., during cardiopulmonary bypass (CPB), before CPB (pre-CPB), and after CPB (post-CPB). The length of intervals of discarded data were recorded for each patient. The median length of intervals of discarded data were compared between AKI and non-AKI patients and between surgical periods. RESULTS: There were more valid PuO2 data in CPB and post-CPB periods compared to the pre-CPB period (81% and 90% vs. 31% of patients included, respectively; p < 0.001 and p < 0.001). Most intervals of discarded data were < 3 minutes during CPB (96%) and post-CPB (98%). The median length was < 25 s during all periods and there was no significant difference in the group median length of discarded data intervals for AKI and non-AKI patients. CONCLUSIONS: PuO2 measurements were acquired with enough temporal resolution to demonstrate real-time PuO2 monitoring during CPB and the post-CPB period. GOV IDENTIFIER: NCT03335865, First Posted Date: Nov. 8th, 2017.


Asunto(s)
Lesión Renal Aguda , Procedimientos Quirúrgicos Cardíacos , Humanos , Presión Parcial , Puente Cardiopulmonar , Lesión Renal Aguda/diagnóstico , Oxígeno , Complicaciones Posoperatorias , Biomarcadores
3.
J Cardiothorac Vasc Anesth ; 36(10): 3904-3915, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35810042

RESUMEN

The importance of right ventricular (RV) dysfunction in patients undergoing cardiac surgery is well recognized. There is extensive literature regarding the accurate assessment of RV dysfunction with both echocardiography and hemodynamic data, but the majority of these studies are with transthoracic echocardiography (TTE) and in awake patients. Many of the tools used to assess the RV with TTE are angle-dependent and, therefore, may be inaccurate with transesophageal echocardiography (TEE). Very few of these modalities have been validated either with TEE or in patients under general anesthesia. The purpose of this review is to discuss the intraoperative tools available to the cardiac anesthesiologist for the assessment of RV function. The authors review the available literature surrounding intraoperative RV assessment, from subjective assessment to traditional objective tools that were developed for TTE and newer technology that can be adapted to both TTE and TEE. Future work should focus on whether or not these intraoperative RV assessment tools predict outcome after cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Disfunción Ventricular Derecha , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ecocardiografía Transesofágica , Humanos , Estudios Prospectivos , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
4.
Anesthesiology ; 135(3): 406-418, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34329393

RESUMEN

BACKGROUND: Acute kidney injury (AKI) is a common complication of cardiac surgery. An intraoperative monitor of kidney perfusion is needed to identify patients at risk for AKI. The authors created a noninvasive urinary oximeter that provides continuous measurements of urinary oxygen partial pressure and instantaneous urine flow. They hypothesized that intraoperative urinary oxygen partial pressure measurements are feasible with this prototype device and that low urinary oxygen partial pressure during cardiac surgery is associated with the subsequent development of AKI. METHODS: This was a prospective observational pilot study. Continuous urinary oxygen partial pressure and instantaneous urine flow were measured in 91 patients undergoing cardiac surgery using a novel device placed between the urinary catheter and collecting bag. Data were collected throughout the surgery and for 24 h postoperatively. Clinicians were blinded to the intraoperative urinary oxygen partial pressure and instantaneous flow data. Patients were then followed postoperatively, and the incidence of AKI was compared to urinary oxygen partial pressure measurements. RESULTS: Intraoperative urinary oxygen partial pressure measurements were feasible in 86/91 (95%) of patients. When urinary oxygen partial pressure data were filtered for valid urine flows greater than 0.5 ml · kg-1 · h-1, then 70/86 (81%) and 77/86 (90%) of patients in the cardiopulmonary bypass (CPB) and post-CPB periods, respectively, were included in the analysis. Mean urinary oxygen partial pressure in the post-CPB period was significantly lower in patients who subsequently developed AKI than in those who did not (mean difference, 6 mmHg; 95% CI, 0 to 11; P = 0.038). In a multivariable analysis, mean urinary oxygen partial pressure during the post-CPB period remained an independent risk factor for AKI (relative risk, 0.82; 95% CI, 0.71 to 0.95; P = 0.009 for every 10-mmHg increase in mean urinary oxygen partial pressure). CONCLUSIONS: Low urinary oxygen partial pressures after CPB may be associated with the subsequent development of AKI after cardiac surgery.


Asunto(s)
Lesión Renal Aguda/fisiopatología , Lesión Renal Aguda/orina , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Monitoreo Intraoperatorio/métodos , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/orina , Lesión Renal Aguda/prevención & control , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oximetría/métodos , Presión Parcial , Proyectos Piloto , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Factores de Riesgo
5.
J Cardiothorac Vasc Anesth ; 35(6): 1691-1700, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33549487

RESUMEN

OBJECTIVES: To evaluate the association of intraoperative urinary biomarker excretion during cardiac surgery and the subsequent development of acute kidney injury (AKI). DESIGN: Prospective, nonrandomized, observational study. SETTING: Single tertiary-level, university-affiliated hospital. PARTICIPANTS: Ninety patients undergoing cardiac surgery with cardiopulmonary bypass (CPB). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Urinary samples were collected every 30 minutes intraoperatively and then at four, 12, and 24 hours after CPB. Samples were measured for interleukin 18 (IL-18), kidney injury molecule-1 (KIM1), and creatinine concentrations. Urinary biomarker excretion (raw and indexed to creatinine) for four intraoperative and three postoperative points were compared between patients with and those without subsequent AKI defined by increased serum creatinine concentration ≥0.3 mg/dL within the first 48 hours or ≥1.5 times baseline within seven days. Raw and indexed median IL-18 values were similar between AKI groups at all intraoperative points, but became significantly different at 12 hours after CPB. Raw and indexed median KIM1 values were significantly different between AKI groups at multiple intraoperative points and at four and 12 hours after CPB. During intraoperative and postoperative points, patients in the fourth quartile of KIM1 excretion had greater AKI incidence and longer intensive care and hospital lengths of stay than those in the first quartile. Only postoperatively did the differences in these outcomes between the fourth and first quartile of IL-18 excretion occur. CONCLUSIONS: Intraoperative KIM1 but not IL-18 excretion was associated with postoperative development of AKI.


Asunto(s)
Lesión Renal Aguda , Procedimientos Quirúrgicos Cardíacos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Biomarcadores , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Creatinina , Humanos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos
6.
J Cardiothorac Vasc Anesth ; 34(8): 2036-2046, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32482504

RESUMEN

This article is the fourth of an annual series reviewing the research highlights of the year pertaining to the subspecialty of perioperative echocardiography for the Journal of Cardiothoracic and Vascular Anesthesia. The authors thank the editor-in-chief, Dr. Kaplan, and the editorial board, for the opportunity to continue this series. In most cases, these were research articles that were targeted at the perioperative echocardiography diagnosis and treatment of patients after cardiothoracic surgery; but in some cases, these articles targetted the use of perioperative echocardiography in general.


Asunto(s)
Anestesia , Anestesiología , Insuficiencia de la Válvula Tricúspide , Ecocardiografía , Humanos
7.
J Cardiothorac Vasc Anesth ; 34(1): 48-57, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31401208

RESUMEN

OBJECTIVE: To compare regional and global measures of right ventricular (RV) strain in patients undergoing intraoperative transesophageal echocardiography (TEE). DESIGN: Prospective, nonrandomized, observational study. SETTING: Single tertiary-level, university hospital. PARTICIPANTS: The study comprised 48 patients undergoing intraoperative TEE. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A global RV strain measurement (termed RV 5-wall strain [RV 5WS]) was calculated by averaging the longitudinal strain calculated from multiple TEE views. This global strain measurement was compared with the more standard regional strain measurements obtained in a single 4-chamber view (RV free-wall strain [RV FWS] and RV global longitudinal strain [RV GLS]) and with traditional measures of RV function. Regional and global strain measurements were feasible in the operating room. RV FWS and RV GLS strongly correlated with RV 5WS (r = 0.86 and 0.87, respectively) with no significant bias and limits of agreement of approximately -5% to 5%. RV FWS and RV GLS were even more closely correlated with each other (r = 0.99) with no significant bias and limits of agreement less than -2% to 2%. Both regional and global RV strain measurements showed a high sensitivity (RV FWS 94%; RV GLS 94%; RV 5WS 89%) and moderate specificity (RV FWS 70%; RV GLS 67%; RV 5WS 63%) for RV dysfunction based on a reference standard of 3-dimensional RV ejection fraction. CONCLUSIONS: Both regional and global RV strain measurements are feasible in the operating room with TEE. Regional and global measures of RV function correlate well and are sensitive indicators of RV dysfunction.


Asunto(s)
Ecocardiografía Transesofágica , Disfunción Ventricular Derecha , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Quirófanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
8.
J Cardiothorac Vasc Anesth ; 33(6): 1507-1515, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30503335

RESUMEN

OBJECTIVE: To compare intraoperative right ventricular (RV) strain measurements made with left ventricular (LV) strain software commonly found on the echocardiography machine (Philips QLAB chamber motion quantification, version 10.7, Philips, Amsterdam, The Netherlands), with offline analysis using the dedicated RV strain software (EchoInsight, version 2.2.6.2230, Epsilon Imaging, Ann Arbor, MI). DESIGN: Prospective, nonrandomized, observational study. SETTING: Single tertiary level, university-affiliated hospital. PARTICIPANTS: The study comprised 48 patients undergoing transesophageal echocardiography for cardiac or noncardiac surgery. INTERVENTIONS: Two-dimensional (2D) and 3-dimensional (3D) images of the right ventricle were obtained. Intraoperative 2D images were analyzed in real time for RV free wall strain (FWS) and global longitudinal strain (GLS) using QLAB chamber motion quantification (CMQ) LV strain software on the echocardiography machine. Two dimensional images were then analyzed offline to determine the RV FWS and GLS using EchoInsight RV-specific strain software. Three-dimensional images were then analyzed offline to detemine the 3D RV ejection fraction (3D RV EF) using TomTec 4D RV function (Unterschleissheim, Germany). Spearman's correlation and Bland-Altman analyses were used to characterize the relationship between RV strain measurements. Both types of strain measurements were compared to a reference standard of 3D RV EF. MEASUREMENTS AND MAIN RESULTS: Intraoperative RV strain measurements using LV-specific strain software correlated with offline RV strain measurements using the RV-specific strain software (FWS rho = 0.85; GLS rho = 0.81). The bias and limits of agreement were 0.75% (- 6.66 to 8.17) for FWS and -4.53% (-11.55 to 2.50) for GLS. The sensitivity and specificity for RV dysfunction for the intraoperative LV-specific software were 94% (95% confidence interval [CI] 73-100) and 70% (95% CI 51-85), respectively, for RV FWS and 94% (95% CI 73-100) and 67% (95% CI 47-83), respectively, for RV GLS. The sensitivity and specificity for RV dysfunction for the offline RV-specific software were 89% (95% CI 65-99) and 73% (95% CI 54-88), respectively, for RV FWS and 94% (95% CI 73-100) and 30% (95% CI 15-49), respectively, for RV GLS. CONCLUSION: Intraoperative RV strain measurements using LV-specific strain software commonly available on the echocardiography machine (QLAB CMQ) correlate with offline RV strain measurements using RV-specific strain software (EchoInsight). The bias and limits of agreement for these left- and right-sided strain software suggest that these 2 measures of RV function cannot be used interchangeably. Both, however, were sensitive measures of RV dysfunction and therefore are likely clinically relevant.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Programas Informáticos , Volumen Sistólico/fisiología , Función Ventricular Derecha/fisiología , Ventrículos Cardíacos/fisiopatología , Humanos , Periodo Intraoperatorio , Estudios Prospectivos , Reproducibilidad de los Resultados , Función Ventricular Izquierda/fisiología
9.
J Cardiothorac Vasc Anesth ; 32(5): 2096-2103, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29555387

RESUMEN

OBJECTIVE: To determine whether intraoperative measures of right ventricular (RV) function using transesophageal echocardiography are associated with subsequent RV failure after left ventricular assist device (LVAD) implantation. DESIGN: Retrospective, nonrandomized, observational study. SETTING: Single tertiary-level, university-affiliated hospital. PARTICIPANTS: The study comprised 100 patients with systolic heart failure undergoing elective LVAD implantation. INTERVENTIONS: Transesophageal echocardiographic images before and after cardiopulmonary bypass were analyzed to quantify RV function using tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S'), fractional area change (FAC), RV global longitudinal strain, and RV free wall strain. A chart review was performed to determine which patients subsequently developed RV failure (right ventricular assist device placement or prolonged inotrope requirement ≥14 days). MEASUREMENTS AND MAIN RESULTS: Nineteen patients (19%) subsequently developed RV failure. Postbypass FAC was the only measure of RV function that distinguished between the RV failure and non-RV failure groups (21.2% v 26.5%; p = 0.04). The sensitivity, specificity, and area under the curve of an abnormal RV FAC (<35%) for RV failure after LVAD implantation were 84%, 20%, and 0.52, respectively. No other intraoperative measure of RV function was associated with subsequent RV failure. RV failure increased ventilator time, intensive care unit and hospital length of stay, and mortality. CONCLUSION: Intraoperative measures of RV function such as tricuspid annular plane systolic excursion, tricuspid annular systolic velocity, and RV strain were not associated with RV failure after LVAD implantation. Decreased postbypass FAC was significantly associated with RV failure but showed poor discrimination.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Insuficiencia Cardíaca Sistólica/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Auxiliar , Monitoreo Intraoperatorio/métodos , Volumen Sistólico/fisiología , Función Ventricular Derecha/fisiología , Femenino , Insuficiencia Cardíaca Sistólica/diagnóstico , Insuficiencia Cardíaca Sistólica/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
Sci Rep ; 14(1): 2646, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38302567

RESUMEN

Acute kidney injury is a common complication of trauma and hemorrhagic shock. In a porcine model of hemorrhagic shock, resuscitative endovascular balloon aortic occlusion (REBOA) and hemodilution, we hypothesized that invasive kidney oxygen concentration measurements would correlate more strongly with noninvasive near infra-red spectroscopy (NIRS) oxygen saturation measurements when cutaneous sensors were placed over the kidney under ultrasound guidance compared to placement over the thigh muscle and subcutaneous tissue. Eight anesthetized swine underwent hemorrhagic shock 4 of which were resuscitated with intravenous fluids prior to the return of shed blood (Hemodilution protocol) and 4 of which underwent REBOA prior to resuscitation and return of shed blood (REBOA protocol). There was a moderate correlation between the NIRS and kidney tissue oxygen measurements (r = 0.61 p < 0.001; r = 0.67 p < 0.001; r = 0.66 p < 0.001for left kidney, right kidney, and thigh NIRS respectively). When the animals were separated by protocol, the Hemodilution group showed a weak or nonsignificant correlation between NIRS and kidney tissue oxygen measurements (r = 0.10 p < 0.001; r = 0.01 p = 0.1007; r = 0.28 p < 0.001 for left kidney, right kidney, and thigh NIRS respectively). This contrasts with the REBOA group, where left and right kidney as well as thigh NIRS were moderately correlated with kidney tissue oxygen (r = 0.71 p < 0.001; r = 0.74 p < 0.001; r = 0.70 p < 0.001; for left kidney, right kidney, and thigh NIRS respectively). There was a strong correlation between both kidney NIRS signals and thigh NIRS measurements (r = 0.85 p < 0.001; r = 0.88 p < 0.001;for left kidney vs thigh and right kidney vs thigh respectively). There was also a strong correlation between left and right kidney NIRS (r = 0.90 p < 0.001). These relationships were maintained regardless of the resuscitation protocol. These results suggest that kidney NIRS measurements were more closely related to thigh NIRS measurements than invasive kidney tissue oxygen concentration.


Asunto(s)
Procedimientos Endovasculares , Choque Hemorrágico , Porcinos , Animales , Choque Hemorrágico/terapia , Espectroscopía Infrarroja Corta , Hemodilución , Oxígeno , Resucitación/métodos , Riñón/diagnóstico por imagen , Procedimientos Endovasculares/métodos , Modelos Animales de Enfermedad
13.
Ann Emerg Med ; 59(3): 159-64, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21831478

RESUMEN

STUDY OBJECTIVES: We compare laryngoscopic quality and time to highest-grade view between a face-to-face approach with the GlideScope and traditional flexible fiber-optic laryngoscopy in awake, upright volunteers. METHODS: This was a prospective, randomized, crossover study in which we performed awake laryngoscopy under local anesthesia on 23 healthy volunteers, using both a GlideScope video laryngoscopy face-to-face technique with the blade held upside down and flexible fiber-optic laryngoscopy. Operator reports of Cormack-Lehane laryngoscopic views and video-reviewed time to highest-grade view, as well as number of attempts, were recorded. RESULTS: Ten women and 13 men participated. A grade II or better view was obtained with GlideScope video laryngoscopy in 22 of 23 (95.6%) participants and in 23 of 23 (100%) participants with flexible fiber-optic laryngoscopy (relative risk GlideScope video laryngoscopy versus flexible fiber-optic laryngoscopy 0.96; 95% confidence interval 0.88 to 1.04). Median time to highest-grade view for GlideScope video laryngoscopy was 16 seconds (interquartile range 9 to 34) versus 51 seconds (interquartile range 35 to 96) for flexible fiber-optic laryngoscopy. A distribution of interindividual differences demonstrated that GlideScope video laryngoscopy was, on average, 39 seconds faster than flexible fiber-optic laryngoscopy (95% confidence interval 0.2 to 76.9 seconds). CONCLUSION: GlideScope video laryngoscopy can be used to obtain a Cormack-Lehane grade II or better view in the majority of awake, healthy volunteers when an upright face-to-face approach is used and was slightly faster than traditional flexible fiber-optic laryngoscopy. However, flexible fiber-optic laryngoscopy may be more reliable at obtaining high-grade views of the larynx. Awake, face-to-face GlideScope use may offer an alternative approach to the difficulty airway, particularly among providers uncomfortable with flexible fiber-optic laryngoscopy.


Asunto(s)
Laringoscopios , Laringoscopía/instrumentación , Estudios Cruzados , Femenino , Humanos , Laringoscopía/métodos , Masculino , Fibras Ópticas , Postura , Factores de Tiempo , Grabación en Video , Cirugía Asistida por Video/instrumentación , Cirugía Asistida por Video/métodos
14.
J Vis Exp ; (188)2022 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-36373937

RESUMEN

Up to 50% of patients with trauma develop acute kidney injury (AKI), in part due to poor renal perfusion after severe blood loss. AKI is currently diagnosed based on a change in serum creatinine concentration from baseline or prolonged periods of decreased urine output. Unfortunately, baseline serum creatinine concentration data is unavailable in most patients with trauma, and current estimation methods are inaccurate. In addition, serum creatinine concentration may not change until 24-48 h after the injury. Lastly, oliguria must persist for a minimum of 6 h to diagnose AKI, making it impractical for early diagnosis. AKI diagnostic approaches available today are not useful for predicting risk during the resuscitation of patients with trauma. Studies suggest that urinary partial pressure of oxygen (PuO2) may be useful for assessing renal hypoxia. A monitor that connects the urinary catheter and the urine collection bag was developed to measure PuO2 noninvasively. The device incorporates an optical oxygen sensor that estimates PuO2 based on luminescence quenching principles. In addition, the device measures urinary flow and temperature, the latter to adjust for confounding effects of temperature changes. Urinary flow is measured to compensate for the effects of oxygen ingress during periods of low urine flow. This article describes a porcine model of hemorrhagic shock to study the relationship between noninvasive PuO2, renal hypoxia, and AKI development. A key element of the model is the ultrasound-guided surgical placement in the renal medulla of an oxygen probe, which is based on an unsheathed optical microfiber. PuO2 will also be measured in the bladder and compared to the kidney and noninvasive PuO2 measurements. This model can be used to test PuO2 as an early marker of AKI and assess PuO2 as a resuscitative endpoint after hemorrhage that is indicative of end-organ rather than systemic oxygenation.


Asunto(s)
Lesión Renal Aguda , Choque Hemorrágico , Porcinos , Animales , Creatinina , Choque Hemorrágico/diagnóstico , Choque Hemorrágico/etiología , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Oxígeno , Hipoxia , Biomarcadores
16.
A A Case Rep ; 9(2): 57-59, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-28704282

RESUMEN

Aortic root abscess is a complication of aortic valve endocarditis that is associated with a high morbidity and mortality. The diagnosis usually is made with transesophageal echocardiography, which is highly sensitive and specific for the disease. We present a case of suspected aortic root abscess 1 week after mechanical aortic valve replacement for native valve endocarditis. The diagnosis was made by the use of transesophageal echocardiography but surgical inspection revealed that the paravalvular fluid collection was excessive surgical adhesive. We discuss the clinical significance and differential diagnosis of aortic root abscess in the setting of infective endocarditis.


Asunto(s)
Absceso/diagnóstico , Adhesivos/efectos adversos , Válvula Aórtica/efectos de los fármacos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Absceso/diagnóstico por imagen , Adhesivos/administración & dosificación , Válvula Aórtica/cirugía , Ecocardiografía Transesofágica , Endocarditis/cirugía , Humanos , Masculino , Adulto Joven
18.
Wilderness Environ Med ; 20(3): 269-74, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19737038

RESUMEN

OBJECTIVE: Risk assessment is an important part of safe backcountry travel in avalanche terrain. The purpose of this study was to determine and compare the ability of backcountry travelers to accurately estimate the avalanche danger for their destination and time of travel. METHODS: We surveyed 353 winter backcountry users, asking them to rate the avalanche danger for their destination that day. We then compared this estimation to the Utah Avalanche Center daily advisory for that specific location, aspect, and elevation. Tendency to underestimate the avalanche danger was then compared across 6 different sports (backcountry skiing, backcountry snowboarding, snowshoeing, snowmobiling, out-of-bounds skiing, and out-of-bounds snowboarding) as well as across age, gender, and subject participation in an avalanche safety course. RESULTS: A comparison across different sports, adjusted for age and gender, showed that snowshoers were 7.11 times more likely than skiers to underestimate the avalanche danger (95% CI, 2.95, 17.11). This difference was maintained after adjusting for past education in an avalanche safety course (odds ratio, 5.74; 95% CI, 2.28, 14.46). Snowmobilers were also significantly more likely to underestimate the avalanche danger when compared to skiers (odds ratio, 3.11; 95% CI, 1.12, 8.24), but these differences ceased to be significant when the data were adjusted for avalanche safety course (odds ratio, 2.39; 95% CI, 0.84, 6.74). While there was a trend for women and older age groups to underestimate the avalanche danger when compared to men, these trends were not significant. CONCLUSIONS: Snowshoers and snowmobilers are groups that tend to underestimate avalanche danger when traveling in the backcountry. These groups may be unknowingly assuming a higher risk and should be targeted for avalanche education and awareness.


Asunto(s)
Avalanchas , Montañismo/educación , Medición de Riesgo , Esquí/educación , Adulto , Avalanchas/mortalidad , Avalanchas/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Montañismo/lesiones , Seguridad , Estaciones del Año , Esquí/lesiones , Viaje , Adulto Joven
19.
Wilderness Environ Med ; 18(4): 264-70, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-18076291

RESUMEN

OBJECTIVE: Avalanche fatalities occur on a yearly basis in Utah. The purpose of this study was to assess avalanche safety practices of different backcountry users in Utah and to identify groups that can be targeted for avalanche safety education. METHODS: We surveyed 353 winter backcountry users to determine the percentage of participants in each group who were traveling with one or more partners; the percentage who were carrying avalanche transceivers, shovels, probes, or AvaLungs; and the percentage who had taken an avalanche safety course. A measure of minimum safe practice was defined as 1) traveling with a partner, 2) carrying an avalanche transceiver, and 3) carrying a shovel. Participants in this study were backcountry skiers, snowboarders, snowshoers, snowmobilers, and out-of-bounds resort skiers/snowboarders traveling in the Wasatch and Uinta Mountains of Utah during the winter of 2005-06. RESULTS: The percentage of backcountry recreationists traveling with one or more partners was not significantly different (P=.0658) among backcountry skiers, snowboarders, snowshoers, snowmobilers, and out-of-bounds resort skiers/snowboarders. These groups did, however, differ in the percentage who carried avalanche transceivers (P<.0001), shovels (P<.0001), probes (P<.0001), and AvaLungs (P=.0020), as well as in the percentage who had taken an avalanche safety course (P<.0001) and the percentage who were carrying out minimum safe practices (P<.0001). Backcountry skiers showed the highest level of avalanche preparedness, with 98% carrying avalanche transceivers, 98% carrying shovels, 77% carrying probes, 86% having taken an avalanche safety course, and 88% carrying out minimum safe practices. Out of bounds snowboarders were the least prepared with 9% carrying avalanche transceivers, 9% carrying shovels, 7% carrying probes, 33% having taken an avalanche safety course, and 2% carrying out minimum safe practices. CONCLUSIONS: There are significant differences in the avalanche safety practices of the various groups of backcountry travelers in Utah. Backcountry skiers and snowboarders were the most prepared, while snowmobilers, snowshoers, and out-of-bounds skiers/snowboarders were relatively less prepared.


Asunto(s)
Desastres , Montañismo/educación , Montañismo/lesiones , Femenino , Humanos , Masculino , Mortalidad/tendencias , Montañismo/normas , Seguridad , Esquí/lesiones , Esquí/tendencias , Utah
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA