RESUMEN
BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).
Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Diseño de Prótesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Femenino , Corazón Auxiliar/efectos adversos , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/estadística & datos numéricos , Accidente Cerebrovascular/etiologíaRESUMEN
BACKGROUND: As left ventricular assist device (LVAD) survival rates continue to improve, evaluating site-specific variability in outcomes can facilitate identifying targets for quality-improvement initiative opportunities in the field. METHODS: Deidentified center-specific outcomes were analyzed for HeartMate 3 (HM3) patients enrolled in the MOMENTUM 3 pivotal and continued access protocol trials. Centers < 25th percentile for HM3 volumes were excluded. Variability in risk-adjusted center mortality was assessed at 90 days and 2 years (conditional upon 90-day survival). Adverse event (AE) rates were compared across centers. RESULTS: In the 48 included centers (1958 patients), study-implant volumes ranged between 17 and 106 HM3s. Despite similar trial-inclusion criteria, patient demographics varied across sites, including age quartile ((Q)1-Q3:57-62 years), sex (73%-85% male), destination therapy intent (60%-84%), and INTERMACS profile 1-2 (16%-48%). Center mortality was highly variable, nadiring at ≤ 3.6% (≤ 25th percentile) and peaking at ≥ 10.4% (≥ 75th percentile) at 90 days and ≤ 10.2% and ≥ 18.7%, respectively, at 2 years. Centers with low mortality rates tended to have lower 2-year AE rates, but no center was a top performer for all AEs studied. CONCLUSIONS: Mortality and AEs were highly variable across MOMENTUM 3 centers. Studies are needed to improve our understanding of the drivers of outcome variability and to ascertain best practices associated with high-performing centers across the continuum of intraoperative to chronic stages of LVAD support.
Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Femenino , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Tasa de Supervivencia , Resultado del TratamientoRESUMEN
BACKGROUND: The MOMENTUM 3 trial compares the centrifugal HeartMate 3 (HM3) with the axial HeartMate II (HMII) continuous-flow left ventricular assist system in patients with advanced heart failure, irrespective of the intended goal of therapy. The trial's 2-year clinical outcome (n=366) demonstrated superiority of the HM3 for the primary end point (survival free of a disabling stroke or reoperation to replace or remove a malfunctioning pump). This analysis evaluates health resource use and cost implications of the observed differences between the 2 devices while patients were enrolled in the trial. METHODS: We analyzed all hospitalizations and their associated costs occurring after discharge from the implant hospitalization until censoring (study withdrawal, heart transplantation, and pump exchange with a nonstudy device or death). Each adjudicated episode of hospital-based care was used to calculate costs (device-attributable and non-device-attributable event costs), estimated by using trial data and payer administrative claims databases. Cost savings stratified by subgroups (study outcome [transplant, death, or ongoing on device], intended goal of therapy, type of insurance, or sex) were also assessed. RESULTS: In 366 randomly assigned patients, 361 comprised the as-treated group (189 in the HM3 group and 172 in the HMII group), of whom 337 (177 in the HM3 group and 160 in the HMII group) were successfully discharged following implantation. The HM3 arm experienced fewer total hospitalizations per patient-year (HM3: 2.1±0.2 versus HMII: 2.7±0.2; P=0.015) and 8.3 fewer hospital days per patient-year on average (HM3: 17.1 days versus HMII: 25.5 days; P=0.003). These differences were driven by patients hospitalized for suspected pump thrombosis (HM3: 0.6% versus HMII: 12.5%; P<0.001) and stroke (HM3: 2.8% versus HMII: 11.3%; P=0.002). Controlled for time spent in the study (average cumulative cost per patient-year), postdischarge HM3 arm costs were 51% lower than with the HMII (HM3: $37 685±4251 versus HMII: $76 599±11 889, P<0.001) and similar in either bridge to transplant or destination therapy intent. CONCLUSIONS: In this 2-year outcome economic analysis of the MOMENTUM 3 trial, the HM3 demonstrated a reduction in rehospitalizations, hospital days spent during rehospitalizations, and a significant cost savings following discharge in comparison with the HMII left ventricular assist system, irrespective of the intended goal of therapy. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02224755.
Asunto(s)
Atención a la Salud/economía , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/economía , Adulto , Anciano , Anciano de 80 o más Años , Costos y Análisis de Costo , Femenino , Insuficiencia Cardíaca/economía , Insuficiencia Cardíaca/patología , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Trombosis/etiología , Resultado del Tratamiento , Adulto JovenAsunto(s)
Médicos , Humanos , Relaciones Médico-Paciente , Características de la Residencia , PacientesRESUMEN
BACKGROUND: The HeartMate 3 (HM3) Left Ventricular Assist System (LVAS) (Abbott) is a centrifugal, fully magnetically levitated, continuous-flow blood pump engineered to enhance hemocompatibility and reduce shear stress on blood components. The MOMENTUM 3 trial (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) compares the HM3 LVAS with the HeartMate II (HMII) LVAS (Abbott) in advanced heart failure refractory to medical management, irrespective of therapeutic intention (bridge to transplant versus destination therapy). This investigation reported its primary outcome in the short-term cohort (n=294; 6-month follow-up), demonstrating superiority of the HM3 for the trial primary end point (survival free of a disabling stroke or reoperation to replace the pump for malfunction), driven by a reduced need for reoperations. The aim of this analysis was to evaluate the aggregate of hemocompatibility-related clinical adverse events (HRAEs) between the 2 LVAS. METHODS: We conducted a secondary end point evaluation of HRAE (survival free of any nonsurgical bleeding, thromboembolic event, pump thrombosis, or neurological event) in the short-term cohort (as-treated cohort n=289) at 6 months. The net burden of HRAE was also assessed by using a previously described hemocompatibility score, which uses 4 escalating tiers of hierarchal severity to derive a total score for events encountered during the entire follow-up experience for each patient. RESULTS: In 289 patients in the as-treated group (151 the HM3 and 138 the HMII), survival free of any HRAE was achieved in 69% of the HM3 group and in 55% of the HMII group (hazard ratio, 0.62; confidence interval, 0.42-0.91; P=0.012). Using the hemocompatibility score, the HM3 group demonstrated less pump thrombosis requiring reoperation (0 versus 36 points, P<0.001) or medically managed pump thrombosis (0 versus 5 points, P=0.02), and fewer nondisabling strokes (6 versus 24 points, P=0.026) than the control HMII LVAS. The net hemocompatibility score in the HM3 in comparison with the HMII patients was 101 (0.67±1.50 points/patient) versus 137 (0.99±1.79 points/patient) (odds ratio, 0.64; confidence interval, 0.39-1.03; P=0.065). CONCLUSIONS: In this secondary analysis of the MOMENTUM 3 trial, the HM3 LVAS demonstrated greater freedom from HRAEs in comparison with the HMII LVAS at 6 months. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT02224755.
Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Imanes , Función Ventricular Izquierda , Anciano , Remoción de Dispositivos , Supervivencia sin Enfermedad , Diseño de Equipo , Falla de Equipo , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Hemólisis , Humanos , Estimación de Kaplan-Meier , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Factores de Riesgo , Estrés Mecánico , Accidente Cerebrovascular/etiología , Trombosis/etiología , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: We observed an apparent increase in the rate of device thrombosis among patients who received the HeartMate II left ventricular assist device, as compared with preapproval clinical-trial results and initial experience. We investigated the occurrence of pump thrombosis and elevated lactate dehydrogenase (LDH) levels, LDH levels presaging thrombosis (and associated hemolysis), and outcomes of different management strategies in a multi-institutional study. METHODS: We obtained data from 837 patients at three institutions, where 895 devices were implanted from 2004 through mid-2013; the mean (±SD) age of the patients was 55±14 years. The primary end point was confirmed pump thrombosis. Secondary end points were confirmed and suspected thrombosis, longitudinal LDH levels, and outcomes after pump thrombosis. RESULTS: A total of 72 pump thromboses were confirmed in 66 patients; an additional 36 thromboses in unique devices were suspected. Starting in approximately March 2011, the occurrence of confirmed pump thrombosis at 3 months after implantation increased from 2.2% (95% confidence interval [CI], 1.5 to 3.4) to 8.4% (95% CI, 5.0 to 13.9) by January 1, 2013. Before March 1, 2011, the median time from implantation to thrombosis was 18.6 months (95% CI, 0.5 to 52.7), and from March 2011 onward, it was 2.7 months (95% CI, 0.0 to 18.6). The occurrence of elevated LDH levels within 3 months after implantation mirrored that of thrombosis. Thrombosis was presaged by LDH levels that more than doubled, from 540 IU per liter to 1490 IU per liter, within the weeks before diagnosis. Thrombosis was managed by heart transplantation in 11 patients (1 patient died 31 days after transplantation) and by pump replacement in 21, with mortality equivalent to that among patients without thrombosis; among 40 thromboses in 40 patients who did not undergo transplantation or pump replacement, actuarial mortality was 48.2% (95% CI, 31.6 to 65.2) in the ensuing 6 months after pump thrombosis. CONCLUSIONS: The rate of pump thrombosis related to the use of the HeartMate II has been increasing at our centers and is associated with substantial morbidity and mortality.
Asunto(s)
Corazón Auxiliar/efectos adversos , L-Lactato Deshidrogenasa/sangre , Trombosis/etiología , Biomarcadores/sangre , Estudios de Seguimiento , Trasplante de Corazón , Humanos , Incidencia , Estimación de Kaplan-Meier , Auditoría Médica , Diseño de Prótesis , Falla de Prótesis , Riesgo , Estadísticas no Paramétricas , Trombosis/epidemiología , Trombosis/mortalidad , Trombosis/terapiaRESUMEN
OBJECTIVE: The aim of this work was to characterize the clinical response and identify predictors of clinical stabilization after intra-aortic balloon counterpulsation (IABP) support in patients with chronic systolic heart failure in cardiogenic shock before implantation of a left ventricular assist device (LVAD). BACKGROUND: Limited data exist regarding the clinical response to IABP in patients with chronic heart failure in cardiogenic shock. METHODS: We identified 54 patients supported with IABP before LVAD implantation. Criteria for clinical decompensation after IABP insertion and before LVAD included the need for more advanced temporary support, initiation of mechanical ventilation or dialysis, increase in vasopressors/inotropes, refractory ventricular arrhythmias, or worsening acidosis. The absence of these indicated stabilization. RESULTS: Clinical decompensation after IABP occurred in 23 patients (43%). Both patients who decompensated and those who stabilized had similar hemodynamic improvements after IABP support, but patients who decompensated required more vasopressors/inotropes. Clinical decompensation after IABP was associated with worse outcomes after LVAD implantation, including a 3-fold longer intensive care unit stay and 5-fold longer time on mechanical ventilation (P < .01 for both). Although baseline characteristics were similar between groups, right and left ventricular cardiac power indexes (cardiac power index = cardiac index × mean arterial pressure/451) identified patients who were likely to stabilize (area under the receiver operating characteristic curve = 0.82). CONCLUSIONS: Among patients with chronic systolic heart failure who develop cardiogenic shock, more than one-half of patients stabilized with IABP support as a bridge to LVAD. Baseline measures of right and left ventricular cardiac power, reflecting work performed for a given flow and pressure, may allow clinicians to identify patients with sufficient contractile reserve who will be likely to stabilize with an IABP versus those who may need more aggressive ventricular support.
Asunto(s)
Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Mortalidad Hospitalaria/tendencias , Contrapulsador Intraaórtico/métodos , Choque Cardiogénico/mortalidad , Choque Cardiogénico/cirugía , Anciano , Causas de Muerte , Enfermedad Crónica , Estudios de Cohortes , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico por imagen , Corazón Auxiliar , Hemodinámica/fisiología , Humanos , Contrapulsador Intraaórtico/efectos adversos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cuidados Preoperatorios/métodos , Curva ROC , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Choque Cardiogénico/diagnóstico , UltrasonografíaRESUMEN
BACKGROUND: Racial and ethnic differences in lung cancer care have been previously documented. These differences may be related to access to care, cultural differences, or fewer patients presenting with operable lung cancer. The relationship between race and pathologic stage of patients who undergo lung cancer resection has not been defined. This study estimates racial disparities in lung cancer stage among patients who undergo surgical resection. METHODS: The Society of Thoracic Surgeons (STS) database was queried for patients who underwent resection of non-small cell lung cancer and had complete pathologic staging and racial identification. Univariate and multivariate analyses were performed. Study end point was the pathologic stage and we evaluated its association with the racial and ethnic origins of the patients. RESULTS: Of 19,173 eligible patients with non-small cell lung cancer of known pathological stage who underwent surgery between 2002 and 2008, the majority were Caucasian (17,148, 89.4%), 1,502 (7.8%) were African-American, 273 (1.4%) were Asian, and 250 (1.3%) were Hispanic. In univariate analysis, significantly more Caucasian and African-American patients underwent resection of stage I/II lung cancer (13,929, 81.2% and 1,217, 81%, respectively) as compared with the Asian (207, 75.2%) and Hispanic (188, 75.8%) patients (p = 0.007). Stage at operation did not differ between Caucasians and African-Americans. Multivariate analysis confirmed these findings (p = 0.03) after adjustment for age, gender, tobacco use, diabetes, and year of surgery. CONCLUSION: Within the STS database, patients identified as Asian or Hispanic had a significantly higher pathologic stage at the time of resection than Caucasian or African-American patients. The causes of these differences in the treatment of potentially curable lung cancer are unknown and require further investigation.
Asunto(s)
Pueblo Asiatico/estadística & datos numéricos , Negro o Afroamericano/estadística & datos numéricos , Carcinoma de Pulmón de Células no Pequeñas/etnología , Carcinoma de Pulmón de Células no Pequeñas/patología , Hispánicos o Latinos/estadística & datos numéricos , Neoplasias Pulmonares/etnología , Neoplasias Pulmonares/patología , Población Blanca/estadística & datos numéricos , Anciano , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Femenino , Humanos , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos , Factores de Riesgo , Estados Unidos/epidemiologíaRESUMEN
OBJECTIVE: To assess the effect of extremity vascular complications (EVCs, including ischemia or vessel trauma) on the outcomes of patients receiving cardiac support devices (CSDs, including ventricular assist device [VAD] and extracorporeal membrane oxygenation [ECMO]). METHODS: Institutional Review Board-approved, retrospective review of a prospectively maintained database of all temporary and permanent CSD recipients from 7/1/10 to 6/30/12. Patient demographics, procedural data, and outcomes were analyzed. The primary endpoint was all-cause mortality at 30-days post-CSD initiation. RESULTS: Of 208 patients who received CSDs, 31 (14.9%) experienced EVC: 13 (8.9%) of the 146 permanent VADs, 10 (26.3%) of the 38 temporary VADs, and 8 (33.3%) of the 24 ECMO patients. The 30-day mortality for CSD-EVC patients was not significantly higher than that of the CSD patients who did not experience EVC for permanent VAD (15.4% vs 4.5%; P = .15) and ECMO patients (50.0% vs 68.75%; P = 1.00), but was significantly higher for temporary VAD patients (80.0% vs 35.7%; P = .03). Within the CSD-EVC cohort, patients who received a temporary VAD had a significantly higher 30-day mortality and decision to withdraw care after EVC compared with those who received a permanent VAD (P = .01 and P < .01, respectively). Looking beyond the 30-day window, EVC was associated with higher mortality rates in the permanent VAD population (53.8% vs 25.6%; P = .025) but not the temporary VAD or ECMO groups. CONCLUSIONS: In temporary VAD recipients, EVCs result in higher 30-day mortality, more frequent withdrawal of care, and shortened survival time relative to the global temporary VAD group. EVC in permanent VAD recipients did not affect early (30-day) mortality rates, but strongly predicted a higher cumulative mortality risk for the 2-year study period. Overall ECMO mortality rates were high, and not significantly impacted by the occurrence of EVC. The nature of the EVC (cannulation site complication vs embolic injury) did not impact mortality. This data provides quality improvement targets for VAD programs.
Asunto(s)
Arteriopatías Oclusivas/etiología , Arteria Axilar , Oxigenación por Membrana Extracorpórea/efectos adversos , Arteria Femoral , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Arteriopatías Oclusivas/epidemiología , Arteriopatías Oclusivas/cirugía , Cateterismo Periférico/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Estados Unidos/epidemiologíaRESUMEN
Data regarding outcomes with Impella 5.5 are limited. The aim of this systematic review and meta-analysis was to summarize patient and treatment characteristics and early clinical outcomes among patients supported by Impella 5.5. A systematic literature search was conducted in PubMed, Scopus, and Cochrane databases from September 2019 to March 2023. Studies reporting outcomes in greater than or equal to 5 patients were included for review. Patient characteristics, treatment characteristics, and early clinical outcomes were extracted. Outcomes included adverse events, survival to hospital discharge, and 30 day survival. Random-effect models were used to estimate pooled effects for survival outcomes. Assessment for bias was performed using funnel plots and Egger's tests. Fifteen studies were included for qualitative review, representing 707 patients. Mean duration of support was 9.9 ± 8.2 days. On meta-analysis of 13 studies reporting survival outcomes, survival to hospital discharge was 68% (95% confidence interval [CI], 58-78%), and 30 day survival was 65% (95% CI, 56-74%) among patients with Impella devices predominantly supported by Impella 5.5 (>60%). There was significant study heterogeneity for these outcomes. Among 294 patients with Impella 5.5 only, survival to discharge was 78% (95% CI, 72-82%) with no significant study heterogeneity. This data present early benchmarks for outcomes with Impella 5.5 as clinical experience with these devices accrues.
Asunto(s)
Corazón Auxiliar , Humanos , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidadRESUMEN
BACKGROUND: This study evaluates the clinical trends and impact of hepatitis C virus-positive (HCV+) donors on waitlist and posttransplant outcomes after heart transplantation. METHODS: The United Network for Organ Sharing registry was queried to identify adult waitlisted and transplanted patients from January 1, 2015, to December 31, 2022. In the waitlist analysis, the candidates were stratified into 2 cohorts based on whether they were willing to accept HCV+ donor offers. Waitlist outcomes included 1-y cumulative incidences of transplantation and death/delisting. In the posttransplant analysis, the recipients were stratified into 2 cohorts with and without HCV nucleic acid test (NAT)-positive donors. Outcomes included 1- and 4-y posttransplant survival. Propensity score-matching was performed. Risk adjustment was performed using multivariable Cox regression. RESULTS: During the study period, the number of centers using HCV NAT+ donors increased from 1 to 65 centers, along with the number of transplants. In the waitlist analysis, 26 648 waitlisted candidates were analyzed, and 4535 candidates (17%) were approved to accept HCV+ donors. Approval to accept HCV+ donors was associated with a higher likelihood of transplantation and a lower likelihood of death/delisting within 1 y of waitlisting. In the posttransplant analysis, 21 131 recipients were analyzed, and 997 recipients (4.7%) received HCV NAT+ hearts. The 1- and 4-y posttransplant survival were comparable between the recipients of HCV NAT+ and NAT- donors. Furthermore, the similar 1- and 4-y posttransplant survival persisted in the propensity score-matched comparison and multivariable Cox regression analysis. CONCLUSIONS: Utilization of HCV+ donors is rising. Heart transplants using HCV+ donors are associated with improved waitlist and comparable posttransplant outcomes.
RESUMEN
BACKGROUND: Thoracoabdominal normothermic regional perfusion (TA-NRP) has emerged as a powerful technique for optimizing organ procurement from donation after circulatory death donors. Despite its rapid adoption, standardized guidelines for TA-NRP implementation are lacking, prompting the need for consensus recommendations to ensure safe and effective utilization of this technique. METHODS: A working group composed of members from The American Society of Transplant Surgeons, The International Society of Heart and Lung Transplantation, The Society of Thoracic Surgeons, and The American Association for Thoracic Surgery was convened to develop technical guidelines for TA-NRP. The group systematically reviewed existing literature, consensus statements, and expert opinions to identify key areas requiring standardization, including predonation evaluation, intraoperative management, postdonation procedures, and future research directions. RESULTS: The working group formulated recommendations encompassing donor evaluation and selection criteria, premortem testing and therapeutic interventions, communication protocols, and procedural guidelines for TA-NRP implementation. These recommendations aim to facilitate coordination among transplant teams, minimize variability in practice, and promote transparency and accountability throughout the TA-NRP process. CONCLUSIONS: The consensus guidelines presented herein serve as a comprehensive framework for the successful and ethical implementation of TA-NRP programs in organ procurement from donation after circulatory death donors. By providing standardized recommendations and addressing areas of uncertainty, these guidelines aim to enhance the quality, safety, and efficiency of TA-NRP procedures, ultimately contributing to improved outcomes for transplant recipients.
Asunto(s)
Preservación de Órganos , Perfusión , Humanos , Perfusión/métodos , Preservación de Órganos/métodos , Preservación de Órganos/normas , Obtención de Tejidos y Órganos/normas , Obtención de Tejidos y Órganos/métodos , Consenso , Donantes de TejidosRESUMEN
BACKGROUND: Thoracoabdominal normothermic regional perfusion (TA-NRP) has emerged as a powerful technique for optimizing organ procurement from donation after circulatory death donors. Despite its rapid adoption, standardized guidelines for TA-NRP implementation are lacking, prompting the need for consensus recommendations to ensure safe and effective utilization of this technique. METHODS: A working group composed of members from The American Society of Transplant Surgeons, The International Society of Heart and Lung Transplantation, The Society of Thoracic Surgeons, and The American Association for Thoracic Surgery was convened to develop technical guidelines for TA-NRP. The group systematically reviewed existing literature, consensus statements, and expert opinions to identify key areas requiring standardization, including predonation evaluation, intraoperative management, postdonation procedures, and future research directions. RESULTS: The working group formulated recommendations encompassing donor evaluation and selection criteria, premortem testing and therapeutic interventions, communication protocols, and procedural guidelines for TA-NRP implementation. These recommendations aim to facilitate coordination among transplant teams, minimize variability in practice, and promote transparency and accountability throughout the TA-NRP process. CONCLUSIONS: The consensus guidelines presented herein serve as a comprehensive framework for the successful and ethical implementation of TA-NRP programs in organ procurement from donation after circulatory death donors. By providing standardized recommendations and addressing areas of uncertainty, these guidelines aim to enhance the quality, safety, and efficiency of TA-NRP procedures, ultimately contributing to improved outcomes for transplant recipients.
Asunto(s)
Consenso , Preservación de Órganos , Perfusión , Humanos , Perfusión/normas , Perfusión/métodos , Preservación de Órganos/normas , Preservación de Órganos/métodos , Donantes de Tejidos/provisión & distribución , Trasplante de Órganos/normas , Trasplante de Órganos/métodos , Selección de Donante/normas , Obtención de Tejidos y Órganos/normas , Obtención de Tejidos y Órganos/métodosRESUMEN
OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.
RESUMEN
The Jarvik 2000 bridge to transplant investigational device exemption study was a multicentered, prospective study of 150 UNOS status I patients implanted with the Jarvik 2000 between 2005 and 2012. During the study period, there were numerous modifications of the system that included converting from pin to cone bearings. Results were analyzed for three cohorts: total (n = 150), pin (n = 128), and cone (n = 22). Baseline demographics included age (52 ± 13), gender (79% male), size (BSA 1.98), and etiology (37% idiopathic dilated cardiomyopathy; 43% Ischemic). Seventy percent of patients were either INTERMACS 1 or 2. The primary endpoint-defined as successful transplantation or listing at 180 days (prespecified at 65%; 95% lower CI: 57%)-was successfully achieved for the total cohort (67.3%; 95% CI: 59.5%-74.3%; p = 0.006). In subgroup analysis of the more contemporary, cone-bearing group, the primary endpoint was met in 91% (95% CI: 72%-97.5%; p = 0.001). Compared with pin patients, cone-bearing patients had less hemolysis as well as decreased end-organ dysfunction. Functional and quality of life scores improved after implantation independent type of bearing. In conclusion, despite a particularly sick patient population, the Jarvik 2000 was shown to be effective in supporting the advanced HF patient.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Femenino , Humanos , Masculino , Insuficiencia Cardíaca/cirugía , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Estados UnidosRESUMEN
We sought to characterize patients who underwent heart transplant (HTx) following destination therapy (DT) implant in the combined ENDURANCE/ENDURANCE Supplemental Trials (DT/DT2). A post hoc analysis of the DT/DT2 trials was performed. Baseline characteristics and adverse events between the HTx and no-HTx cohorts were analyzed. Reasons for transplant were examined. Time to HTx was compared with contemporaneous HVAD BTT trial patients. Of the 604 DT/DT2 HVAD patients, 80 (13%) underwent HTx. The HTx cohort was younger (53.6 ± 11.1 vs. 65.2 ± 10.8, P < 0.0001) with fewer Caucasians (60.0% vs. 76.5%, P = 0.002), less ischemic cardiomyopathy (42.5% vs. 58.8%, P = 0.01), and atrial fibrillation (38.8% vs. 54.4%, P = 0.01). The HTx cohort had longer 6-minute walk distances (183.6 vs. 38.0 m, P = 0.02). Most HTx in DT/DT2 were categorized as elective (n = 63, 79%) and, of these, 70% were due to modification of behavioral issues and weight loss. Adverse events were the main indication for urgent HTx (n = 17, 21%). Median times to HTx were longer in DT/DT2 (550.0 days) versus BTT/lateral (285.2 days). In this post hoc analysis of the DT/DT2 trials, over 1 in 10 underwent heart transplantation within 3 years of HVAD support. In DT therapy patients, consideration for transplant following DT VAD implant may be feasible.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: In the MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3) pivotal trial, the HeartMate 3 (HM3) fully magnetically levitated left ventricular assist device (LVAD) demonstrated superiority over the axial-flow HeartMate II (HMII) LVAD. The patterns and predictors of hospitalizations with the HM3 LVAD have not been characterized. OBJECTIVES: This study sought to determine causes, predictors, and impact of hospitalizations during LVAD support. METHODS: Patients discharged after LVAD implantation were analyzed. In the pivotal trial, 485 recipients of HM3 were compared with 471 recipients of HMII. The pivotal trial HM3 group was also compared to 949 recipients of HM3 in the postapproval phase within the trial portfolio. Predictors of cause-specific rehospitalization were analyzed. RESULTS: The rates of rehospitalization were lower with HM3 LVAD than with HMII LVAD in the pivotal trial (225.7 vs 246.4 events per 100 patient-years; P < 0.05). Overall, rehospitalization rates and duration were similar in the HM3 postapproval phase and pivotal trial but prolonged hospitalizations (>7 days) were less frequent (rate ratio: 0.90 [95% CI: 0.80-0.98]; P < 0.05). In HM3 recipients, the most frequent causes of rehospitalization included infection, heart failure (HF)-related events, and bleeding. First rehospitalization caused by HF-related event versus other causes was associated with reduced survival (HR: 2.2 [95% CI: 1.3-3.9]; P = 0.0014). Male sex, non-White race, presence of cardiac resynchronization therapy/implantable cardioverter-defibrillator, obesity, higher right atrial pressure, smaller LV size, longer duration of index hospitalization, and lower estimated glomerular filtration rate at index discharge predicted HF hospitalizations. CONCLUSIONS: Contemporary support with the HM3 fully magnetically levitated LVAD is associated with a lower hospitalization burden than with prior pumps; however, rehospitalizations for infection, HF, and bleeding remain important challenges for progress in the patient journey. (MOMENTUM 3 IDE Clinical Study, NCT02224755; MOMENTUM 3 Continued Access Protocol [MOMENTUM 3 CAP], NCT02892955).
Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Corazón Auxiliar/efectos adversos , Hospitalización , Humanos , Masculino , Factores de Tiempo , Resultado del TratamientoRESUMEN
Left ventricular dysfunction with apical ballooning consistent with Takotsubo cardiomyopathy was encountered in a 68-year-old woman at 5 h after an uneventful mitral valve replacement and tricuspid valve repair. Preoperatively, the patient had emotional stress as well as worsening congestive heart failure, which might have contributed to this rare postoperative complication. Following diagnosis by transthoracic echocardiography (TTE), and characteristic findings of apical ballooning and a preserved basal contraction of the left ventricle, intra-aortic balloon pumping (IABP) was initiated to minimize the use of inotropic drugs. The patient was successfully weaned from both the IABP and pharmacological support. Follow up with serial TTE showed a gradual recovery of the left ventricle to normal systolic function. The mechanism of onset and pathophysiology of Takotsubo cardiomyopathy remain unclear, especially in postoperative cardiac surgery patients. Since excessive catecholamine stimulation has been proposed as a possible mechanism of Takotsubo cardiomyopathy, early mechanical circulatory assistance after cardiac surgery is advised to minimize catecholamine use in this rare complication.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Cardiomiopatía de Takotsubo/diagnóstico , Disfunción Ventricular Izquierda/etiología , Anciano , Diagnóstico Diferencial , Ecocardiografía , Femenino , Humanos , Complicaciones Posoperatorias , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatologíaRESUMEN
AIMS: Continuous-flow left ventricular assist devices (LVADs) as destination therapy (DT) are a recommended treatment by National Institute for Health and Care Excellence England for end-stage heart failure patients ineligible for cardiac transplantation. Despite the fact that DT is frequently used as an LVAD indication across other major European countries and the United States, with consistent improvements in quality-of-life and longevity, National Health Service (NHS) England does not currently fund DT, mainly due to concerns over cost-effectiveness. On the basis of the recently published ENDURANCE Supplemental Trial studying DT patients, we assessed for the first time the cost-effectiveness of DT LVADs compared with medical management (MM) in the NHS England. METHODS AND RESULTS: We developed a Markov multiple-state economic model using NHS cost data. LVAD survival and adverse event rates were derived from the ENDURANCE Supplemental Trial. MM survival was based on Seattle Heart Failure Model estimates in the absence of contemporary clinical trials for this population. Incremental cost-effectiveness ratios (ICERs) were calculated over a lifetime horizon. A discount rate of 3.5% per year was applied to costs and benefits. Deterministic ICER was £46 207 per quality-adjusted life year (QALY). Costs and utilities were £204 022 and 3.27 QALYs for the LVAD arm vs. £77 790 and 0.54 QALYs for the MM arm. Sensitivity analyses confirmed robustness of the primary analysis. CONCLUSIONS: The implantation of the HeartWare™ HVAD™ System in patients ineligible for cardiac transplantation as DT is a cost-effective therapy in the NHS England healthcare system under the end-of-life willingness-to-pay threshold of £50 000/QALY, which applies for VAD patients.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Análisis Costo-Beneficio , Insuficiencia Cardíaca/cirugía , Humanos , Medicina Estatal , Estados Unidos/epidemiologíaRESUMEN
BACKGROUND: Several distinctly engineered left ventricular assist devices (LVADs) are in clinical use. However, contemporaneous real world comparisons have not been conducted, and clinical trials were not powered to evaluate differential survival outcomes across devices. OBJECTIVES: Determine real world survival outcomes and healthcare expenditures for commercially available durable LVADs. METHODS: Using a retrospective observational cohort design, Medicare claims files were linked to manufacturer device registration data to identify de-novo, durable LVAD implants performed between January 2014 and December 2018, with follow-up through December 2019. Survival outcomes were compared using a Cox proportional hazards model stratified by LVAD type and validated using propensity score matching. Healthcare resource utilization was analyzed across device types by using nonparametric bootstrap analysis methodology. Primary outcome was survival at 1-year and total Part A Medicare payments. RESULTS: A total of 4,195 de-novo LVAD implants were identified in fee-for-service Medicare beneficiaries (821 HeartMate 3; 1,840 HeartMate II; and 1,534 Other-VADs). The adjusted hazard ratio for mortality at 1-year (confirmed in a propensity score matched analysis) for the HeartMate 3 vs HeartMate II was 0.64 (95% CI; 0.52-0.79, p< 0.001) and for the HeartMate 3 vs Other-VADs was 0.51 (95% CI; 0.42-0.63, p < 0.001). The HeartMate 3 cohort experienced fewer hospitalizations per patient-year vs Other-VADs (respectively, 2.8 vs 3.2 EPPY hospitalizations, p < 0.01) and 6.1 fewer hospital days on average (respectively, 25.2 vs 31.3 days, p < 0.01). The difference in Medicare expenditures, conditional on survival, for HeartMate 3 vs HeartMate II was -$10,722, p < 0.001 (17.4% reduction) and for HeartMate 3 vs Other-VADs was -$17,947, p < 0.001 (26.1% reduction). CONCLUSIONS: In this analysis of a large, real world, United States. administrative dataset of durable LVADs, we observed that the HeartMate 3 had superior survival, reduced healthcare resource use, and lower healthcare expenditure compared to other contemporary commercially available LVADs.