Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Ultrasound ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767265

RESUMEN

An update on the antenatal diagnosis of agenesis of ductus venosus (ADV) by differentiating the various possible types of shunts, focusing on the associated fetal anomalies, and predicting neonatal outcomes. This study reviewed the experience of two tertiary referral centers and literature. An unfavorable outcome was detected in preterm fetuses (p = 0.017), fetuses with a genetic anomaly (p = 0.046) or other associated malformations (p < 0.001). 71% of ADVs with other anomalies had an extrahepatic ADV (p = 0.002). 76% of fetuses with Fetal Growth Restriction (FGR) had an extrahepatic ADV (p = 0.025). ADV may negatively influence fetal growth in cases with extrahepatic vein drainage.

2.
Arch Gynecol Obstet ; 307(4): 1233-1241, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35599249

RESUMEN

PURPOSE: To compare the effects of epidural analgesia (EA) and combined spinal epidural analgesia (SEA) on labor and maternal-fetal outcomes. METHODS: We retrospectively identified and included 1499 patients with a single cephalic fetus who delivered at the study center from January 2015 to December 2018 and received neuraxial analgesia at the beginning of the active phase of labor (presence of regular painful contractions and cervical dilatation between 4 and 6 cm). Data including analgesia, labor characteristics, and maternal-fetal outcomes were retrieved from the prospectively collected delivery room database and medical records. RESULTS: SEA was associated with a shorter first stage of labor than EA, with a median difference of 60 min. On multivariable ordinal logistic regression analysis, neuraxial analgesia, gestational age, fetal weight, labor induction, and parity were independently associated with the first stage length: patients in the EA group were 1.32 times more likely to have a longer first stage of labor (95% CI 1.06-1.64, p = 0.012) than those in the SEA group. Additionally, a significantly lower incidence of fundal pressure was performed among patients who underwent SEA (OR 0.55, 95% CI 0.34-0.9, p = 0.017). No associations were observed between the used neuraxial analgesia technique and other outcomes. CONCLUSIONS: SEA was associated with a shorter length of the first stage of labor and a lower rate of fundal pressure use than EA. Further studies confirming the effects of SEA on labor management and clarifying differences in maternal-fetal outcomes will allow concluding about the superiority of one technique upon the other.


Asunto(s)
Analgesia Epidural , Analgesia Obstétrica , Anestesia Raquidea , Trabajo de Parto , Embarazo , Femenino , Humanos , Estudios Retrospectivos , Analgesia Epidural/métodos , Manejo del Dolor/métodos , Analgesia Obstétrica/métodos
3.
Clin Chim Acta ; 507: 156-160, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32302685

RESUMEN

INTRODUCTION AND AIM: Carbohydrate Deficient Transferrin (CDT) is one of the most used biomarkers for monitoring alcohol use in pregnancy. However, its effective application in this context is hampered by the demonstrated physiological progressive increase during pregnancy (even in abstinent women) of CDT values, which in the third trimester can reach values close or exceeding the cut-offs usually adopted in clinical and forensic diagnostics. The present work was aimed at the re-assessment of CDT reference values in pregnancy. MATERIALS AND METHODS: The CDT analysis was performed by a validated HPLC-UV Vis method on 284 serum samples of women with a physiological pregnancy and on 370 sera of non-pregnant woman from the general population (control group). All the samples were tested also for GGT for excluding alcohol abuse. The statistical analysis was performed using the MedCalc® Statistical Software. RESULTS: The re-definition of the specific reference concentrations was carried out according to the Horn and Pesce Robust Method. The resulting CDT upper reference values were 1.45%, 2.01% and 2.05% in the first, second, and third trimester, respectively. CONCLUSIONS: In order to prevent the development of maternal and fetal prenatal alcohol exposure complications, the use of alcohol biomarkers, including CDT, has been proposed. However, this biomarker, in the monitoring of alcohol use in pregnancy, has so far been applied adopting the same cut-off used for general population without taking into consideration the progressive physiological increase of its value throughout the pregnancy. In the present study, a specific re-assessment of the CDT reference concentrations of each trimester is reported.


Asunto(s)
Consumo de Bebidas Alcohólicas/sangre , Alcoholismo/sangre , Transferrina/análogos & derivados , Adolescente , Adulto , Cromatografía Liquida , Femenino , Humanos , Embarazo , Valores de Referencia , Transferrina/análisis , Transferrina/normas , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA