1.
J Neuroeng Rehabil ; 20(1): 113, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37658408

RESUMEN

BACKGROUND: Soft robotic exosuits can provide partial dorsiflexor and plantarflexor support in parallel with paretic muscles to improve poststroke walking capacity. Previous results indicate that baseline walking ability may impact a user's ability to leverage the exosuit assistance, while the effects on continuous walking, walking stability, and muscle slacking have not been evaluated. Here we evaluated the effects of a portable ankle exosuit during continuous comfortable overground walking in 19 individuals with chronic hemiparesis. We also compared two speed-based subgroups (threshold: 0.93 m/s) to address poststroke heterogeneity. METHODS: We refined a previously developed portable lightweight soft exosuit to support continuous overground walking. We compared five minutes of continuous walking in a laboratory with the exosuit to walking without the exosuit in terms of ground clearance, foot landing and propulsion, as well as the energy cost of transport, walking stability and plantarflexor muscle slacking. RESULTS: Exosuit assistance was associated with improvements in the targeted gait impairments: 22% increase in ground clearance during swing, 5° increase in foot-to-floor angle at initial contact, and 22% increase in the center-of-mass propulsion during push-off. The improvements in propulsion and foot landing contributed to a 6.7% (0.04 m/s) increase in walking speed (R2 = 0.82). This enhancement in gait function was achieved without deterioration in muscle effort, stability or cost of transport. Subgroup analyses revealed that all individuals profited from ground clearance support, but slower individuals leveraged plantarflexor assistance to improve propulsion by 35% to walk 13% faster, while faster individuals did not change either. CONCLUSIONS: The immediate restorative benefits of the exosuit presented here underline its promise for rehabilitative gait training in poststroke individuals.


Asunto(s)
Robótica , Accidente Cerebrovascular , Humanos , Caminata , Marcha , Extremidad Inferior
2.
J Appl Biomech ; 37(4): 373-379, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34111842

RESUMEN

The addition of a load during walking requires changes in the movement pattern. The investigation of the dynamic joint stiffness behavior may help to understand the lower limb joints' contribution to these changes. This study aimed to investigate the dynamic stiffness of lower limb joints in response to the increased load carried while walking. Thirteen participants walked in two conditions: unloaded (an empty backpack) and loaded (the same backpack plus added mass corresponding to 30% of body mass). Dynamic stiffness was calculated as the linear slope of the regression line on the moment-angle curve during the power absorption phases of the ankle, knee, and hip in the sagittal plane. The results showed that ankle (P = .002) and knee (P < .001) increased their dynamic stiffness during loaded walking compared with unloaded, but no difference was observed at the hip (P = .332). The dynamic stiffness changes were different among joints (P < .001): ankle and knee changes were not different (P < .992), but they had a greater change than hip (P < .001). The nonuniform increases in lower limb joint dynamic stiffness suggest that the ankle and knee are critical joints to deal with the extra loading.


Asunto(s)
Articulación del Tobillo , Articulación de la Rodilla/fisiología , Caminata , Soporte de Peso , Articulación del Tobillo/fisiología , Fenómenos Biomecánicos , Marcha , Humanos , Extremidad Inferior
3.
J Exp Biol ; 220(Pt 22): 4169-4176, 2017 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-29141879

RESUMEN

Although it is clear that walking over different irregular terrain is associated with altered biomechanics, there is little understanding of how we quickly adapt to unexpected variations in terrain. This study aims to investigate which adaptive strategies humans adopt when performing an unanticipated step on an irregular surface, specifically a small bump. Nine healthy male participants walked at their preferred walking speed along a straight walkway during five conditions: four involving unanticipated bumps of two different heights, and one level walking condition. Muscle activation of eight lower limb muscles and three-dimensional gait analysis were evaluated during these testing conditions. Two distinct adaptive strategies were found, which involved no significant change in total lower limb mechanical work or walking speed. An ankle-based strategy was adopted when stepping on a bump with the forefoot, whereas a hip-based strategy was preferred when stepping with the rearfoot. These strategies were driven by a higher activation of the plantarflexor muscles (6-51%), which generated a higher ankle joint moment during the forefoot conditions and by a higher activation of the quadriceps muscles (36-93%), which produced a higher knee joint moment and hip joint power during the rearfoot conditions. These findings provide insights into how humans quickly react to unexpected events and could be used to inform the design of adaptive controllers for wearable robots intended for use in unstructured environments that can provide optimal assistance to the different lower limb joints.


Asunto(s)
Extremidad Inferior/fisiología , Caminata/fisiología , Adaptación Fisiológica , Adulto , Articulación del Tobillo/fisiología , Fenómenos Biomecánicos , Marcha/fisiología , Articulación de la Cadera/fisiología , Humanos , Articulación de la Rodilla/fisiología , Masculino , Adulto Joven
4.
J Neuroeng Rehabil ; 14(1): 72, 2017 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-28701215

RESUMEN

BACKGROUND: Different groups developed wearable robots for walking assistance, but there is still a need for methods to quickly tune actuation parameters for each robot and population or sometimes even for individual users. Protocols where parameters are held constant for multiple minutes have traditionally been used for evaluating responses to parameter changes such as metabolic rate or walking symmetry. However, these discrete protocols are time-consuming. Recently, protocols have been proposed where a parameter is changed in a continuous way. The aim of the present study was to compare effects of continuously varying assistance magnitude with a soft exosuit against discrete step conditions. METHODS: Seven participants walked on a treadmill wearing a soft exosuit that assists plantarflexion and hip flexion. In Continuous-up, peak exosuit ankle moment linearly increased from approximately 0 to 38% of biological moment over 10 min. Continuous-down was the opposite. In Discrete, participants underwent five periods of 5 min with steady peak moment levels distributed over the same range as Continuous-up and Continuous-down. We calculated metabolic rate for the entire Continuous-up and Continuous-down conditions and the last 2 min of each Discrete force level. We compared kinematics, kinetics and metabolic rate between conditions by curve fitting versus peak moment. RESULTS: Reduction in metabolic rate compared to Powered-off was smaller in Continuous-up than in Continuous-down at most peak moment levels, due to physiological dynamics causing metabolic measurements in Continuous-up and Continuous-down to lag behind the values expected during steady-state testing. When evaluating the average slope of metabolic reduction over the entire peak moment range there was no significant difference between Continuous-down and Discrete. Attempting to correct the lag in metabolics by taking the average of Continuous-up and Continuous-down removed all significant differences versus Discrete. For kinematic and kinetic parameters, there were no differences between all conditions. CONCLUSIONS: The finding that there were no differences in biomechanical parameters between all conditions suggests that biomechanical parameters can be recorded with the shortest protocol condition (i.e. single Continuous directions). The shorter time and higher resolution data of continuous sweep protocols hold promise for the future study of human interaction with wearable robots.


Asunto(s)
Dispositivo Exoesqueleto , Robótica/métodos , Adulto , Tobillo/fisiología , Fenómenos Biomecánicos , Dióxido de Carbono/metabolismo , Femenino , Pie/fisiología , Cadera/fisiología , Humanos , Cinética , Masculino , Consumo de Oxígeno/fisiología , Caminata , Adulto Joven
5.
J Neuroeng Rehabil ; 14(1): 62, 2017 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-28651596

RESUMEN

BACKGROUND: Only very recently, studies have shown that it is possible to reduce the metabolic rate of unloaded and loaded walking using robotic ankle exoskeletons. Some studies obtained this result by means of high positive work assistance while others combined negative and positive work assistance. There is no consensus about the isolated contribution of negative work assistance. Therefore, the aim of the present study is to examine the effect of varying negative work assistance at the ankle joint while maintaining a fixed level of positive work assistance with a multi-articular soft exosuit. METHODS: We tested eight participants during walking at 1.5 ms-1 with a 23-kg backpack. Participants wore a version of the exosuit that assisted plantarflexion via Bowden cables tethered to an off-board actuation platform. In four active conditions we provided different rates of exosuit bilateral ankle negative work assistance ranging from 0.015 to 0.037 W kg-1 and a fixed rate of positive work assistance of 0.19 W kg-1. RESULTS: All active conditions significantly reduced metabolic rate by 11 to 15% compared to a reference condition, where the participants wore the exosuit but no assistance was provided. We found no significant effect of negative work assistance. However, there was a trend (p = .08) toward greater reduction in metabolic rate with increasing negative work assistance, which could be explained by observed reductions in biological ankle and hip joint power and moment. CONCLUSIONS: The non-significant trend of increasing negative work assistance with increasing reductions in metabolic rate motivates the value in further studies on the relative effects of negative and positive work assistance. There may be benefit in varying negative work over a greater range or in isolation from positive work assistance.


Asunto(s)
Articulación del Tobillo , Dispositivo Exoesqueleto , Caminata , Adulto , Algoritmos , Fenómenos Biomecánicos , Metabolismo Energético , Diseño de Equipo , Voluntarios Sanos , Articulación de la Cadera , Humanos , Masculino , Movimiento , Consumo de Oxígeno , Robótica , Adulto Joven
6.
J Neuroeng Rehabil ; 13(1): 43, 2016 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-27169361

RESUMEN

BACKGROUND: Carrying load alters normal walking, imposes additional stress to the musculoskeletal system, and results in an increase in energy consumption and a consequent earlier onset of fatigue. This phenomenon is largely due to increased work requirements in lower extremity joints, in turn requiring higher muscle activation. The aim of this work was to assess the biomechanical and physiological effects of a multi-joint soft exosuit that applies assistive torques to the biological hip and ankle joints during loaded walking. METHODS: The exosuit was evaluated under three conditions: powered (EXO_ON), unpowered (EXO_OFF) and unpowered removing the equivalent mass of the device (EXO_OFF_EMR). Seven participants walked on an instrumented split-belt treadmill and carried a load equivalent to 30 % their body mass. We assessed their metabolic cost of walking, kinetics, kinematics, and lower limb muscle activation using a portable gas analysis system, motion capture system, and surface electromyography. RESULTS: Our results showed that the exosuit could deliver controlled forces to a wearer. Net metabolic power in the EXO_ON condition (7.5 ± 0.6 W kg(-1)) was 7.3 ± 5.0 % and 14.2 ± 6.1 % lower than in the EXO_OFF_EMR condition (7.9 ± 0.8 W kg(-1); p = 0.027) and in the EXO_OFF condition (8.5 ± 0.9 W kg(-1); p = 0.005), respectively. The exosuit also reduced the total joint positive biological work (sum of hip, knee and ankle) when comparing the EXO_ON condition (1.06 ± 0.16 J kg(-1)) with respect to the EXO_OFF condition (1.28 ± 0.26 J kg(-1); p = 0.020) and to the EXO_OFF_EMR condition (1.22 ± 0.21 J kg(-1); p = 0.007). CONCLUSIONS: The results of the present work demonstrate for the first time that a soft wearable robot can improve walking economy. These findings pave the way for future assistive devices that may enhance or restore gait in other applications.


Asunto(s)
Metabolismo Energético/fisiología , Dispositivo Exoesqueleto , Robótica/instrumentación , Dispositivos de Autoayuda , Caminata/fisiología , Tobillo/fisiología , Fenómenos Biomecánicos , Electromiografía , Cadera/fisiología , Humanos , Rodilla/fisiología , Extremidad Inferior , Masculino , Robótica/métodos
7.
J Neuroeng Rehabil ; 13(1): 87, 2016 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-27716439

RESUMEN

BACKGROUND: Recent advances in wearable robotic devices have demonstrated the ability to reduce the metabolic cost of walking by assisting the ankle joint. To achieve greater gains in the future it will be important to determine optimal actuation parameters and explore the effect of assisting other joints. The aim of the present work is to investigate how the timing of hip extension assistance affects the positive mechanical power delivered by an exosuit and its effect on biological joint power and metabolic cost during loaded walking. In this study, we evaluated 4 different hip assistive profiles with different actuation timings: early-start-early-peak (ESEP), early-start-late-peak (ESLP), late-start-early-peak (LSEP), late-start-late-peak (LSLP). METHODS: Eight healthy participants walked on a treadmill at a constant speed of 1.5 m · s-1 while carrying a 23 kg backpack load. We tested five different conditions: four with the assistive profiles described above and one unpowered condition where no assistance was provided. We evaluated participants' lower limb kinetics, kinematics, metabolic cost and muscle activation. RESULTS: The variation of timing in the hip extension assistance resulted in a different amount of mechanical power delivered to the wearer across conditions; with the ESLP condition providing a significantly higher amount of positive mechanical power (0.219 ± 0.006 W · kg-1) with respect to the other powered conditions. Biological joint power was significantly reduced at the hip (ESEP and ESLP) and at the knee (ESEP, ESLP and LSEP) with respect to the unpowered condition. Further, all assistive profiles significantly reduced the metabolic cost of walking compared to the unpowered condition by 5.7 ± 1.5 %, 8.5 ± 0.9 %, 6.3 ± 1.4 % and 7.1 ± 1.9 % (mean ± SE for ESEP, ESLP, LSEP, LSLP, respectively). CONCLUSIONS: The highest positive mechanical power delivered by the soft exosuit was reported in the ESLP condition, which showed also a significant reduction in both biological hip and knee joint power. Further, the ESLP condition had the highest average metabolic reduction among the powered conditions. Future work on autonomous hip exoskeletons may incorporate these considerations when designing effective control strategies.


Asunto(s)
Dispositivo Exoesqueleto , Articulación de la Cadera/fisiología , Robótica/instrumentación , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Caminata/fisiología
8.
Nat Biomed Eng ; 7(4): 456-472, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36550303

RESUMEN

Exoskeletons can augment the performance of unimpaired users and restore movement in individuals with gait impairments. Knowledge of how users interact with wearable devices and of the physiology of locomotion have informed the design of rigid and soft exoskeletons that can specifically target a single joint or a single activity. In this Review, we highlight the main advances of the past two decades in exoskeleton technology and in the development of lower-extremity exoskeletons for locomotor assistance, discuss research needs for such wearable robots and the clinical requirements for exoskeleton-assisted gait rehabilitation, and outline the main clinical challenges and opportunities for exoskeleton technology.


Asunto(s)
Dispositivo Exoesqueleto , Humanos , Marcha , Locomoción
9.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37941269

RESUMEN

Stroke is a leading cause of gait disability that leads to a loss of independence and overall quality of life. The field of clinical biomechanics aims to study how best to provide rehabilitation given an individual's impairments. However, there remains a disconnect between assessment tools used in biomechanical analysis and in clinics. In particular, 3-dimensional ground reaction forces (3D GRFs) are used to quantify key gait characteristics, but require lab-based equipment, such as force plates. Recent efforts have shown that wearable sensors, such as pressure insoles, can estimate GRFs in real-world environments. However, there is limited understanding of how these methods perform in people post-stroke, where gait is highly heterogeneous. Here, we evaluate three subject-specific machine learning approaches to estimate 3D GRFs with pressure insoles in people post-stroke across varying speeds. We find that a Convolutional Neural Network-based approach achieves the lowest estimation errors of 0.75 ± 0.24, 1.13 ± 0.54, and 4.79 ± 3.04 % bodyweight for the medio-lateral, antero-posterior, and vertical GRF components, respectively. Estimated force components were additionally strongly correlated with the ground truth measurements ( ). Finally, we show high estimation accuracy for three clinically relevant point metrics on the paretic limb. These results suggest the potential for an individualized machine learning approach to translate to real-world clinical applications.


Asunto(s)
Calidad de Vida , Accidente Cerebrovascular , Humanos , Pie , Marcha , Fenómenos Mecánicos , Fenómenos Biomecánicos , Caminata
10.
Artículo en Inglés | MEDLINE | ID: mdl-34396094

RESUMEN

Hemiparetic walking after stroke is typically slow, asymmetric, and inefficient, significantly impacting activities of daily living. Extensive research shows that functional, intensive, and task-specific gait training is instrumental for effective gait rehabilitation, characteristics that our group aims to encourage with soft robotic exosuits. However, standard clinical assessments may lack the precision and frequency to detect subtle changes in intervention efficacy during both conventional and exosuit-assisted gait training, potentially impeding targeted therapy regimes. In this paper, we use exosuit-integrated inertial sensors to reconstruct three clinically meaningful gait metrics related to circumduction, foot clearance, and stride length. Our method corrects sensor drift using instantaneous information from both sides of the body. This approach makes our method robust to irregular walking conditions poststroke as well as usable in real-time applications, such as real-time movement monitoring, exosuit assistance control, and biofeedback. We validate our algorithm in eight people poststroke in comparison to lab-based optical motion capture. Mean errors were below 0.2 cm (9.9%) for circumduction, -0.6 cm (-3.5%) for foot clearance, and 3.8 cm (3.6%) for stride length. A single-participant case study shows our technique's promise in daily-living environments by detecting exosuit-induced changes in gait while walking in a busy outdoor plaza.

11.
IEEE Robot Autom Lett ; 5(2): 828-835, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33748413

RESUMEN

Locomotor impairments afflict more than 80% of people poststroke. Our group has previously developed a unilateral ankle exosuit aimed at assisting the paretic ankle joint of stroke survivors during walking. While studies to date have shown promising biomechanical and physiological changes, there remains opportunity to better understand how changes in plantarflexion (PF) assistance profiles impact wearer response. In healthy populations, studies explicitly varying augmentation power have been informative about how exosuit users are sensitive to changes in PF assistance; however there are challenges in applying existing methods to a medical population where significantly higher gait variability and limited walking capacity exist. This paper details an offline assistance optimization scheme that uses pre-recorded biomechanics data to generate torque profiles designed to deliver either positive or negative augmentation power in PF while being less sensitive to stride-by-stride variability. Additionally, we describe an admittance-control strategy that can effectively deliver PF force with RMS error less than 10 N. A preliminary study on six people poststroke demonstrates that offline assistance optimization can successfully isolate positive and negative augmentation power. Moreover, we show that in people poststroke, positive augmentation power effected changes in total positive ankle power while delivering negative augmentation power had no effect on total negative ankle power.

12.
J Biomech ; 83: 76-84, 2019 01 23.
Artículo en Inglés | MEDLINE | ID: mdl-30514626

RESUMEN

Previous ankle exoskeleton assistance techniques that were able to demonstrate metabolic reductions can be categorized into those that delivered moment profiles similar to the biological ankle moment throughout the stance phase, and others that delivered positive power only during push off. Both assistance techniques and a powered-off condition were compared in treadmill walking (1.5 m s-1) with a soft exosuit. We hypothesized that both techniques can result in a similar metabolic reduction when providing a similar level of average positive exosuit power at each ankle (0.12 W kg-1) and hip (0.02 W kg-1) while the underlying global center-of-mass and local joint biomechanics would be different. We found a similar net metabolic rate reduction of 15% relative to walking with the suit powered-off for both techniques. The ankle moment inspired technique showed larger magnitudes of reductions for biological moment and power at the hip and the ankle. The ankle power inspired technique might benefit from higher biological efficiency, when reducing positive instead of negative power at the knee and when almost keeping the isometric function of the plantarflexors before push-off. Changes at the ankle caused energetic reductions at the knee, hip and the center-of-mass. A major contribution to metabolic reduction might be based on them. As the lower limb biomechanics that led to these reductions were different, we believe that humans alter their gait to maximize their energetic benefit based on the exosuit assistance. For further insights on mechanisms that lead to metabolic reduction, joint mechanics and muscle-tendon dynamics must be analyzed in combination.


Asunto(s)
Tobillo , Fenómenos Mecánicos , Robótica , Caminata , Adulto , Fenómenos Biomecánicos , Metabolismo Energético , Terapia por Ejercicio , Femenino , Marcha , Humanos , Masculino
13.
Sci Rep ; 9(1): 9779, 2019 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-31278286

RESUMEN

Different adaptation rates have been reported in studies involving ankle exoskeletons designed to reduce the metabolic cost of their wearers. This work aimed to investigate energetic adaptations occurring over multiple training sessions, while walking with a soft exosuit assisting the hip joint. The participants attended five training sessions within 20 days. They walked carrying a load of 20.4 kg for 20 minutes with the exosuit powered and five minutes with the exosuit unpowered. Percentage change in net metabolic cost between the powered and unpowered conditions improved across sessions from -6.2 ± 3.9% (session one) to -10.3 ± 4.7% (session five), indicating a significant effect associated with training. The percentage change at session three (-10.5 ± 4.5%) was similar to the percentage change at session five, indicating that two 20-minute sessions may be sufficient for users to fully adapt and maximize the metabolic benefit provided by the exoskeleton. Retention was also tested measuring the metabolic reduction five months after the last training session. The percent change in metabolic cost during this session (-10.1 ± 3.2%) was similar to the last training session, indicating that the adaptations resulting in reduced metabolic cost are preserved. These outcomes are relevant when evaluating exoskeletons' performance on naïve users, with a specific focus on hip extension assistance.


Asunto(s)
Adaptación Fisiológica , Metabolismo Energético/fisiología , Dispositivo Exoesqueleto , Articulación de la Cadera/metabolismo , Robótica/instrumentación , Robótica/métodos , Caminata/fisiología , Biotecnología/métodos , Estudios de Seguimiento , Marcha/fisiología , Voluntarios Sanos , Humanos , Masculino , Personal Militar , Estados Unidos , Adulto Joven