Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Health Qual Life Outcomes ; 16(1): 25, 2018 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-29378607

RESUMEN

BACKGROUND: For patient undergoing cataract surgery in India, existing patient-reported outcome (PRO) measures are either not culturally relevant, have not been adequately validated, or are too long to be used in a busy clinical setting. We sought to develop and validate a brief and culturally relevant point-of-care PRO measure to address this need. METHODS: Twelve items from the Indian Visual Functioning Questionnaire (IND-VFQ) were selected based on preliminary data. Patients 18 years and older were prospectively recruited at Aravind Eye Care System in Madurai, India. Clinical and sociodemographic data were collected and the 12-item short-form IND-VFQ (SF-IND-VFQ) was administered pre- and post-operatively to 225 patients; Factor analysis and Rasch modeling was performed to assess its psychometric properties. RESULTS: One item that did not fit a unidimensional scale and had poor fit with the Rasch model was eliminated from the questionnaire. The remaining 11 items represented a single construct (no residual correlations> 0.1) and were largely unaffected by differential item functioning. Five items had disordered thresholds resolved by collapsing the response scale from four to three categories. The survey had adequate reliability (0.80) and good construct (infit range, 0.77-1.29; outfit range, 0.56-1.30) and content (item separation index, 5.87 logits) validity. Measurement precision was fair (person separation index, 1.97). There was evidence that items were not optimally targeted to patients' visual ability (preoperatively, - 1.92 logits; overall, - 3.41 logits), though the survey measured a very large effect (Cohen's d 1.80). In a subset of patients, the average time to complete the questionnaire was 2 min 6.3 s. CONCLUSIONS: The SF-IND-VFQ is a valid, reliable, sensitive, and rapidly administered point-of-care PRO measure to assess changes in visual functioning in patients undergoing cataract surgery in India.


Asunto(s)
Extracción de Catarata , Medición de Resultados Informados por el Paciente , Sistemas de Atención de Punto/normas , Calidad de Vida , Anciano , Femenino , Humanos , India , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Psicometría , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA