Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
PLoS One ; 12(1): e0169392, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28076368

RESUMEN

BACKGROUND: Functional magnetic resonance imaging (fMRI) in neonates has been introduced as a non-invasive method for studying sensorimotor processing in the developing brain. However, previous neonatal studies have delivered conflicting results regarding localization, lateralization, and directionality of blood oxygenation level dependent (BOLD) responses in sensorimotor cortex (SMC). Amongst the confounding factors in interpreting neonatal fMRI studies include the use of standard adult MR-coils providing insufficient signal to noise, and liberal statistical thresholds, compromising clinical interpretation at the single subject level. PATIENTS / METHODS: Here, we employed a custom-designed neonatal MR-coil adapted and optimized to the head size of a newborn in order to improve robustness, reliability and validity of neonatal sensorimotor fMRI. Thirteen preterm infants with a median gestational age of 26 weeks were scanned at term-corrected age using a prototype 8-channel neonatal head coil at 3T (Achieva, Philips, Best, NL). Sensorimotor stimulation was elicited by passive extension/flexion of the elbow at 1 Hz in a block design. Analysis of temporal signal to noise ratio (tSNR) was performed on the whole brain and the SMC, and was compared to data acquired with an 'adult' 8 channel head coil published previously. Task-evoked activation was determined by single-subject SPM8 analyses, thresholded at p < 0.05, whole-brain FWE-corrected. RESULTS: Using a custom-designed neonatal MR-coil, we found significant positive BOLD responses in contralateral SMC after unilateral passive sensorimotor stimulation in all neonates (analyses restricted to artifact-free data sets = 8/13). Improved imaging characteristics of the neonatal MR-coil were evidenced by additional phantom and in vivo tSNR measurements: phantom studies revealed a 240% global increase in tSNR; in vivo studies revealed a 73% global and a 55% local (SMC) increase in tSNR, as compared to the 'adult' MR-coil. CONCLUSIONS: Our findings strengthen the importance of using optimized coil settings for neonatal fMRI, yielding robust and reproducible SMC activation at the single subject level. We conclude that functional lateralization of SMC activation, as found in children and adults, is already present in the newborn period.


Asunto(s)
Potenciales Evocados Motores/fisiología , Lateralidad Funcional/fisiología , Recien Nacido Prematuro , Corteza Sensoriomotora/fisiología , Encéfalo/crecimiento & desarrollo , Encéfalo/fisiología , Mapeo Encefálico/instrumentación , Mapeo Encefálico/métodos , Femenino , Edad Gestacional , Cabeza/crecimiento & desarrollo , Cabeza/fisiología , Humanos , Recién Nacido , Recien Nacido Prematuro/fisiología , Recien Nacido Prematuro/psicología , Imagen por Resonancia Magnética , Masculino , Tamizaje Neonatal/instrumentación , Tamizaje Neonatal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA