Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Osteoarthritis Cartilage ; 30(6): 896-907, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35331858

RESUMEN

OBJECTIVE: The association between the spatially distributed level of active TGFß1 in human subchondral bone, and the characteristic structural and cellular parameters of human knee OA, was assessed. DESIGN: Paired subchondral bone samples from 35 OA arthroplasty patients, (15 men and 20 women, aged 69 ± 9 years) were obtained from beneath macroscopically present (CA+) or denuded cartilage (CA-) to determine the concentration of active TGFß1 (ELISA) and its relationship to bone quality (synchrotron micro-CT), cellularity, and vascularization (histology). RESULTS: Bone samples beneath (CA-) regions had significantly increased concentrations of active TGFß1 protein (mean difference: 26.4; 95% CI: [3.2, 49.7]), when compared to bone in CA + regions. Trabecular Bone below (CA-) regions had increased bone volume (median difference: 4.3; 96.49% CI: [-1.7, 17.8]), increased trabecular number (1.5 [0.006, 2.6], decreased trabecular separation (-0.05 [-0.1,-0.005]), and increased bone mineral density (394.5 [65.7, 723.3]) comparing to (CA+) regions. Further, (CA-) bone regions showed increased osteocyte density (0.012 [0.006, 0.018]), with larger osteocyte lacunae (39.8 [7.8, 71.7]) that were less spherical (-0.02 [-0.04, -0.003]), and increased bone matrix vascularity (12.4 [0.3, 24.5]) compared to (CA+). In addition, increased levels of active TGFß1 related to increased bone volume (0.04 [-0.11, 0.9]), while increased OARSI grade associated with lacunar volume (-44.1 [-71.1, -17.2]), and orientation (2.7 [0.8, 4.6]). CONCLUSION: Increased concentration of active TGFß1 in the subchondral bone of human knee OA associates spatially with impaired bone quality and disease severity, suggesting that TGFß1 is a potential therapeutic target to prevent or reduce human OA disease progression.


Asunto(s)
Cartílago Articular , Osteoartritis de la Rodilla , Factor de Crecimiento Transformador beta1/metabolismo , Cartílago Articular/patología , Femenino , Humanos , Articulación de la Rodilla/patología , Masculino , Osteoartritis de la Rodilla/patología , Microtomografía por Rayos X
2.
Eur Cell Mater ; 42: 264-280, 2021 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-34622431

RESUMEN

Osteomyelitis associated with periprosthetic joint infection (PJI) signals a chronic infection and the need for revision surgery. An osteomyelitic bone exhibits distinct morphological features, including evidence for osteolysis and an accelerated bone remodelling into poorly organised, poor-quality bone. In addition to immune cells, various bone cell-types have been implicated in the pathology. The present study sought to determine the types of bone-cell activities in human PJI bones. Acetabular biopsies from peri-implant bone from patients undergoing revision total hip replacement (THR) for chronic PJI (with several identified pathogens) as well as control bone from the same patients and from patients undergoing primary THR were analysed. Histological analysis confirmed that PJI bone presented increased osteoclastic activity compared to control bone. Analysis of osteocyte parameters showed no differences in osteocyte lacunar area between the acetabular bone taken from PJI patients or primary THR controls. Analysis of bone matrix composition using Masson's trichrome staining and second-harmonic generation microscopy revealed widespread lack of mature collagen, commonly surrounding osteocytes, in PJI bone. Increased expression of known collagenases, such as matrix metallopeptidase (MMP) 13, MMP1 and cathepsin K (CTSK), was measured in infected bone compared to non-infected bone. Human bone and cultured osteocyte-like cells experimentally exposed to Staphylococcus aureus exhibited strongly upregulated expression of MMP1, MMP3 and MMP13 compared to non-exposed controls. In conclusion, the study identified previously unrecognised bone-matrix changes in PJI caused by multiple organisms deriving from osteocytes. Histological examination of bone collagen composition may provide a useful adjunct diagnostic measure of PJI.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteólisis , Infecciones Relacionadas con Prótesis , Artroplastia de Reemplazo de Cadera/efectos adversos , Matriz Ósea , Humanos , Osteocitos , Infección Persistente
3.
Osteoarthritis Cartilage ; 26(4): 547-556, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29382604

RESUMEN

OBJECTIVE: To study, in end-stage knee osteoarthritis (OA) patients, relationships between indices of in vivo dynamic knee joint loads obtained pre-operatively using gait analysis, static knee alignment, and the subchondral trabecular bone (STB) microarchitecture of their excised tibial plateau quantified with 3D micro-CT. DESIGN: Twenty-five knee OA patients scheduled for total knee arthroplasty underwent pre-operative gait analysis. Mechanical axis deviation (MAD) was determined radiographically. Following surgery, excised tibial plateaus were micro-CT-scanned and STB microarchitecture analysed in four subregions (anteromedial, posteromedial, anterolateral, posterolateral). Regional differences in STB microarchitecture and relationships between joint loading and microarchitecture were examined. RESULTS: STB microarchitecture differed among subregions (P < 0.001), anteromedially exhibiting highest bone volume fraction (BV/TV) and lowest structure model index (SMI). Anteromedial BV/TV and SMI correlated strongest with the peak external rotation moment (ERM; r = -0.74, r = 0.67, P < 0.01), despite ERM being the lowest (by factor of 10) of the moments considered, with majority of ERM measures below accuracy thresholds; medial-to-lateral BV/TV ratios correlated with ERM, MAD, knee adduction moment (KAM) and internal rotation moment (|r|-range: 0.54-0.74). When controlling for walking speed, KAM and MAD, the ERM explained additional 11-30% of the variations in anteromedial BV/TV and medial-to-lateral BV/TV ratio (R2 = 0.59, R2 = 0.69, P < 0.01). CONCLUSIONS: This preliminary study suggests significant associations between tibial plateau STB microarchitecture and knee joint loading indices in end-stage knee OA patients. Particularly, anteromedial BV/TV correlates strongest with ERM, whereas medial-to-lateral BV/TV ratio correlates strongest with indicators of medial-to-lateral joint loading (MAD, KAM) and rotational moments. However, associations with ERM should be interpreted with caution.


Asunto(s)
Marcha/fisiología , Articulación de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico , Tibia/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Anciano , Artroplastia de Reemplazo de Rodilla , Cartílago Articular/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/fisiopatología , Masculino , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Periodo Preoperatorio , Pronóstico , Índice de Severidad de la Enfermedad
4.
Osteoarthritis Cartilage ; 26(7): 847-863, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29474993

RESUMEN

OBJECTIVE: To determine the change in walking gait biomechanics after total hip arthroplasty (THA) for osteoarthritis (OA) compared to the pre-operative gait status, and to compare the recovery of gait following THA with healthy individuals. METHODS: Systematic review with meta-analysis of studies investigating changes in gait biomechanics after THA compared to (1) preoperative levels and (2) healthy individuals. Data were pooled at commonly reported time points and standardised mean differences (SMDs) were calculated in meta-analyses for spatiotemporal, kinematic and kinetic parameters. RESULTS: Seventy-four studies with a total of 2,477 patients were included. At 6 weeks postoperative, increases were evident for walking speed (SMD: 0.32, 95% confidence intervals (CI) 0.14, 0.50), stride length (SMD: 0.40, 95% CI 0.19, 0.61), step length (SMD: 0.41, 95% CI 0.23, 0.59), and transverse plane hip range of motion (ROM) (SMD: 0.36, 95% CI 0.05, 0.67) compared to pre-operative gait. Sagittal, coronal and transverse hip ROM was significantly increased at 3 months (SMDs: 0.50 to 1.07). At 12 months postoperative, patients demonstrated deficits compared with healthy individuals for walking speed (SMD: -0.59, 95% CI -1.08 to -0.11), stride length (SMD: -1.27, 95% CI -1.63, -0.91), single limb support time (SMD: -0.82, 95% CI -1.23, -0.41) and sagittal plane hip ROM (SMD: -1.16, 95% CI -1.83, -0.49). Risk of bias scores ranged from seven to 24 out of 26. CONCLUSIONS: Following THA for OA, early improvements were demonstrated for spatiotemporal and kinematic gait patterns compared to the pre-operative levels. Deficits were still observed in THA patients compared to healthy individuals at 12 months.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos/fisiología , Marcha/fisiología , Osteoartritis de la Cadera/cirugía , Rango del Movimiento Articular/fisiología , Recuperación de la Función/fisiología , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico , Periodo Posoperatorio , Periodo Preoperatorio , Pronóstico , Índice de Severidad de la Enfermedad , Factores de Tiempo , Velocidad al Caminar
5.
Osteoarthritis Cartilage ; 25(10): 1623-1632, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28642164

RESUMEN

OBJECTIVES: To (1) stratify patient subgroups according to their distinct walking gait patterns in end-stage knee osteoarthritis (OA); (2) compare measures of joint loading and proximal tibia subchondral trabecular bone (STB) microarchitecture among these gait subgroups. DESIGN: Twenty-five knee OA patients undergoing total knee arthroplasty (TKA) had pre-operative gait analysis. Following surgery, excised tibial plateaus were micro-CT-scanned and STB microarchitecture analysed in four tibial condylar regions of interest. Peak knee moments were input to k-means cluster analysis, to identify subgroups with homogeneous gait patterns. Joint loading and STB microarchitecture parameters were compared among gait subgroups (Kruskal-Wallis, Bonferroni-corrected Mann-Whitney U tests). RESULTS: Three gait subgroups were revealed: biphasics (n = 7), flexors (n = 9), counter-rotators (n = 9). Peak knee adduction moment (KAM) and KAM impulse were significantly higher (P < 0.05) in biphasics than in flexors and counter-rotators (KAM = -0.65, -0.40 and -0.21 Nm/kg, respectively), suggesting a higher medial-to-lateral tibiofemoral load ratio in biphasics. Interestingly, STB medial-to-lateral bone volume fraction (BV/TV) ratio was also significantly higher (more than double) in biphasics and flexors than in counter-rotators (2.24, 2.00 and 1.00, respectively), whereas in biphasics it was only 10% higher than in flexors and not significantly so. CONCLUSIONS: Within the confines of the limited sample size, data suggests that different mechanisms between the biphasic and flexor gait subroups may generate comparable loads upon the tibial plateau and corresponding bony responses, despite significantly lower KAM indices in flexors. Hence, in flexor gait OA patients, conservative treatments designed to reduce KAM, may not be appropriate. Understanding joint loading among walking gait patterns and relationships to bone microarchitecture may aid at identifying/improving management of persons at risk for developing knee OA.


Asunto(s)
Marcha/fisiología , Articulación de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/fisiopatología , Tibia/patología , Soporte de Peso/fisiología , Anciano , Artroplastia de Reemplazo de Rodilla , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/patología , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/patología , Osteoartritis de la Rodilla/cirugía , Dimensión del Dolor/métodos , Rango del Movimiento Articular/fisiología , Índice de Severidad de la Enfermedad , Tibia/diagnóstico por imagen , Microtomografía por Rayos X/métodos
6.
J Orthop Res ; 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38850264

RESUMEN

Revision total hip arthroplasty (rTHA) involving acetabular defects is a complex procedure associated with lower rates of success than primary THA. Computational modeling has played a key role in surgical planning and prediction of postoperative outcomes following primary THA, but modeling applications in rTHA for acetabular defects remain poorly understood. This study aimed to systematically review the use of computational modeling in acetabular defect classification, implant selection and placement, implant design, and postoperative joint functional performance evaluation following rTHA involving acetabular defects. The databases of Web of Science, Scopus, Medline, Embase, Global Health and Central were searched. Fifty-three relevant articles met the inclusion criteria, and their quality were evaluated using a modified Downs and Black evaluation criteria framework. Manual image segmentation from computed tomography scans, which is time consuming, remains the primary method used to generate 3D models of hip bone; however, statistical shape models, once developed, can be used to estimate pre-defect anatomy rapidly. Finite element modeling, which has been used to estimate bone stresses and strains, and implant micromotion postoperatively, has played a key role in custom and off-the-shelf implant design, mitigation of stress shielding, and prediction of bone remodeling and implant stability. However, model validation is challenging and requires rigorous evaluation and comparison with respect to mid- to long-term clinical outcomes. Development of fast, accurate methods to model acetabular defects, including statistical shape models and artificial neural networks, may ultimately improve uptake of and expand applications in modeling and simulation of rTHA for the research setting and clinic.

7.
Clin Orthop Relat Res ; 468(12): 3314-21, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20680531

RESUMEN

BACKGROUND: Despite stem subsidence being a major complication of femoral impaction bone grafting in cemented revision hip arthroplasty, few studies have distinguished subsidence at the prosthesis-cement interface from that at the cement-bone interface. It is unknown how technique developments intended to improve the procedure influence stability of the stem. QUESTIONS/PURPOSES: We used a sensitive technique to measure subsidence of a cemented polished collarless double-taper stem at each interface after femoral impaction grafting and compared subsidence, radiographic loosening, complications, and reoperations over three series of hips defined by technique developments. PATIENTS AND METHODS: Three series were defined: Series 1 (n = 23, irradiated allograft), Series 2 (n = 12, double-washed, size-profiled graft, nonirradiated bone, long stems as required), and Series 3 (n = 21, modular tamps). Stem subsidence was analyzed with Ein Bild Röntgen Analyse software. Radiographic loosening, complications, and reoperations were also determined. RESULTS: The median subsidence at 12 months for Series 1, 2, and 3 were 2.1, 0.5, and 0.7 mm at the prosthesis-cement interface and 1.3, 0.1, and 0.1 mm at the cement-bone interface. There were two postoperative Vancouver B periprosthetic fractures in Series 1, four hips were revised for loosening in Series 1, and there were no fractures or loosening in Series 2 and 3 at minimum 2 years' followup. There were no surviving hips radiographically classified as possibly or probably loose. CONCLUSIONS: Evolution in techniques of femoral impaction grafting in this study were associated with reduced subsidence of the stem at both the prosthesis-cement interface and cement-bone interface when compared to the original series. Concurrent with reduced stem subsidence was the absence of periprosthetic fracture, radiographic loosening, and complications requiring rerevision.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Trasplante Óseo , Fémur/cirugía , Articulación de la Cadera/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos/uso terapéutico , Trasplante Óseo/efectos adversos , Femenino , Fémur/diagnóstico por imagen , Fracturas Óseas/etiología , Fracturas Óseas/prevención & control , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Prótesis de Cadera , Humanos , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/prevención & control , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Reoperación , Australia del Sur , Factores de Tiempo , Trasplante Homólogo , Resultado del Tratamiento
8.
Bone Joint J ; 101-B(4): 415-425, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30929490

RESUMEN

AIMS: The purpose of this exploratory study was to investigate if the 24-hour activity profile (i.e. waking activities and sleep) objectively measured using wrist-worn accelerometry of patients scheduled for total hip arthroplasty (THA) improves postoperatively. PATIENTS AND METHODS: A total of 51 THA patients with a mean age of 64 years (24 to 87) were recruited from a single public hospital. All patients underwent THA using the same surgical approach with the same prosthesis type. The 24-hour activity profiles were captured using wrist-worn accelerometers preoperatively and at 2, 6, 12, and 26 weeks postoperatively. Patient-reported outcomes (Hip Disability and Osteoarthritis Outcome Score (HOOS)) were collected at all timepoints except two weeks postoperatively. Accelerometry data were used to quantify the intensity (sedentary, light, moderate, and vigorous activities) and frequency (bouts) of activity during the day and sleep efficiency. The analysis investigated changes with time and differences between Charnley class. RESULTS: Patients slept or were sedentary for a mean of 19.5 hours/day preoperatively and the 24-hour activity pattern did not improve significantly postoperatively. Outside of sleep, the patients spent their time in sedentary activities for a mean of 620 minutes/day (sd 143) preoperatively and 641 minutes/day (sd 133) six months postoperatively. No significant improvements were observed for light, moderate, and vigorous intensity activities (p = 0.140, p = 0.531, and p = 0.407, respectively). Sleep efficiency was poor (< 85%) at all timepoints. There was no postoperative improvement in sleep efficiency when adjusted for medications (p > 0.05). Patient-reported outcome measures showed a significant improvement with time in all domains when compared with preoperative levels. There were no differences with Charnley class at six months postoperatively. However, Charnley class C patients were more sedentary at two weeks postoperatively when compared with Charnley class A patients (p < 0.05). There were no further differences between Charnley classifications. CONCLUSION: This study describes the 24-hour activity profile of THA patients for the first time. Prior to THA, patients in this cohort were inactive and slept poorly. This cohort shows no improvement in 24-hour activity profiles at six months postoperative. Cite this article: Bone Joint J 2019;101-B:415-425.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Actividad Motora/fisiología , Osteoartritis de la Cadera/cirugía , Medición de Resultados Informados por el Paciente , Recuperación de la Función/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Articulación de la Cadera , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/fisiopatología , Satisfacción del Paciente , Periodo Posoperatorio , Estudios Prospectivos , Encuestas y Cuestionarios , Factores de Tiempo , Adulto Joven
9.
Clin Anat ; 21(7): 674-82, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18773474

RESUMEN

Pelvic external fixators have a high rate of reported complications, most of which relate to pin placement. In this descriptive study, we analyzed the morphology of the ilium in cadaveric specimens and compared these with the measures obtained from normal human pelvic computer tomograph scans, and how these related to each of the three basic configurations of pin positioning for the external fixation of a pelvis: anterosuperior (Slätis type), anteroinferior (supra-acetabular), and subcristal. The irregular shape and size of the iliac wing and the abdominal wall overlying the pin's insertion site could hinder accurate placement of anterosuperior pins. Potential disadvantages of the use of anteroinferior pins was found related to the deep location of the anterior inferior iliac spine, interference with the hip flexion area, risk of hip joint penetration, and the variable obliquity of the ilium. As subcristal pins are positioned between two superficial bony landmarks of the iliac crest, our findings suggest that they are more likely to have a correct placement and avoid complications.


Asunto(s)
Fijadores Externos , Ilion/anatomía & histología , Procedimientos Ortopédicos/instrumentación , Huesos Pélvicos/anatomía & histología , Clavos Ortopédicos , Humanos , Ilion/diagnóstico por imagen , Ilion/cirugía , Procedimientos Ortopédicos/métodos , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía , Tomografía Computarizada por Rayos X
10.
J Orthop Surg (Hong Kong) ; 15(1): 91-3, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17429127

RESUMEN

We report a case of an extra-articular talocalcaneal coalition located anterolateral to the sinus tarsi. As non-osseous coalitions can be difficult to diagnose, physicians should keep this variant in mind in cases of a symptomatic hind foot with apparently equivocal radiological findings.


Asunto(s)
Calcáneo/anomalías , Astrágalo/anomalías , Anciano , Calcáneo/diagnóstico por imagen , Humanos , Masculino , Astrágalo/diagnóstico por imagen , Tomografía Computarizada por Rayos X
11.
Injury ; 48(7): 1714-1716, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28465005

RESUMEN

BACKGROUND: Fixation strength of constructs placed across the pubic symphysis after injury is dependent on screw length, maximisation of which requires knowledge of the bony anatomy. The aim of this study was to describe the ideal angle of drilling to achieve maximal safe screw placement within the pubic body. Furthermore, the influences of age and gender on the skeletal topography were investigated. METHODS: Three hundred CT scans of patients without pelvic injury were analysed to record the angle of the pubic body (APB) with respect to the coronal plane, and the depth of the pubic body (DPB) in the sagittal plane. RESULTS: Mean APB and DPB were 54.69° and 55.35mm, respectively. Females had a significantly higher mean APB than males (57.29° vs. 52.41°; p<0.001), whereas males had a significant larger mean DPB (59.13mm vs. 51.03mm; p<0.001). Age had no effect on the mean APB. Mean width of the pubic body at the base was 9.38mm. CONCLUSION: The anatomy of this region is reliable in terms of angles and sizes; a drill angle of 55° with respect to the operating table will allow maximal screw length, which should be in the region of 55mm. The mean width of the pubic body should allow for placement of a 3.5 or 4.5mm diameter screw.


Asunto(s)
Fijación Interna de Fracturas/instrumentación , Pelvis/anatomía & histología , Sínfisis Pubiana/anatomía & histología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas , Tornillos Óseos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Sínfisis Pubiana/cirugía , Adulto Joven
12.
Bone Joint J ; 99-B(4): 465-474, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28385935

RESUMEN

AIMS: The purpose of this study was to determine the sensitivity, specificity and predictive values of previously reported thresholds of proximal translation and sagittal rotation of cementless acetabular components used for revision total hip arthroplasty (THA) at various times during early follow-up. PATIENTS AND METHODS: Migration of cementless acetabular components was measured retrospectively in 84 patients (94 components) using Ein-Bild-Rontgen-Analyse (EBRA-Cup) in two groups of patients. In Group A, components were recorded as not being loose intra-operatively at re-revision THA (52 components/48 patients) and Group B components were recorded to be loose at re-revision (42 components/36 patients). RESULTS: The mean proximal translation and sagittal rotation were significantly higher in Group B than in Group A from three months onwards (p < 0.02). Proximal translation > 1.0 mm within 24 months had a positive predictive value (PPV) of 90% and a specificity of 94%, but a sensitivity of 64%. Proximal translation > 1.0 mm within the first 24 months correctly identified 76 of 94 (81%) of components to be either loose or not loose. However, ten components in Group B (24%) did not migrate proximally above 1.0 mm within the first 60 months. CONCLUSION: The high PPV of EBRA-Cup measurements of proximal translation (90%) shows that this can be used in early follow-up to identify patients at risk of aseptic loosening. The absence of proximal translation within the first 60 months indicates a component is not likely to be loose at re-revision THA although it does not exclude late aseptic loosening as a cause of failure. Cite this article: Bone Joint J 2017;99-B:465-74.


Asunto(s)
Acetábulo/diagnóstico por imagen , Artroplastia de Reemplazo de Cadera/efectos adversos , Migración de Cuerpo Extraño/diagnóstico por imagen , Falla de Prótesis/etiología , Acetábulo/patología , Acetábulo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/patología , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Periodo Posoperatorio , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reoperación/efectos adversos
13.
Bone Joint J ; 99-B(4): 458-464, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28385934

RESUMEN

AIMS: This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria. PATIENTS AND METHODS: Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed. RESULTS: Using EBRA, both proximal translation and sagittal rotation were excellent diagnostic tests for detecting aseptic loosening. The area under the receiver operating characteristic (ROC) curves was 0.94 and 0.93, respectively. The thresholds of 2.5 mm proximal translation or 2° sagittal rotation (EBRA) in combination with radiolucency criteria had a sensitivity of 93% and specificity of 88% to detect aseptic loosening. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of radiolucency criteria were 41%, 100%, 100% and 68% respectively. Manual measurements of both proximal translation and sagittal rotation were very good diagnostic tests. The area under the ROC curve was 0.86 and 0.92 respectively. However, manual measurements had a decreased specificity compared with EBRA. Radiolucency criteria had a poor sensitivity and NPV of 41% and 68% respectively. CONCLUSION: This study shows that EBRA and manual migration measurements can be used as accurate diagnostic tools to detect aseptic loosening of cementless acetabular components used at revision THA. Radiolucency criteria should not be used in isolation to exclude loosening of cementless acetabular components used at revision THA given their poor sensitivity and NPV. Cite this article: Bone Joint J 2017;99-B:458-64.


Asunto(s)
Acetábulo/diagnóstico por imagen , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Humanos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Falla de Prótesis , Radiografía , Reoperación/efectos adversos , Reoperación/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad
14.
Bone Joint J ; 97-B(8): 1038-45, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26224818

RESUMEN

The outcome of 219 revision total hip arthroplasties (THAs) in 98 male and 121 female patients, using 137 long length and 82 standard length cemented collarless double-taper femoral stems in 211 patients, with a mean age of 72 years (30 to 90) and mean follow-up of six years (two to 18) have been described previously. We have extended the follow-up to a mean of 13 years (8 to 20) in this cohort of patients in which the pre-operative bone deficiency Paprosky grading was IIIA or worse in 79% and 73% of femurs with long and standard stems, respectively. For the long stem revision group, survival to re-revision for aseptic loosening at 14 years was 97% (95% confidence interval (CI) 91 to 100) and in patients aged > 70 years, survival was 100%. Two patients (two revisions) were lost to follow-up and 86 patients with 88 revisions had died. Worst-case analysis for survival to re-revision for aseptic loosening at 14 years was 95% (95% CI 89 to 100) and 99% (95% CI 96 to 100) for patients aged > 70 years. One additional long stem was classified as loose radiographically but not revised. For the standard stem revision group, survival to re-revision for aseptic loosening at 14 years was 91% (95% CI 83 to 99). No patients were lost to follow-up and 49 patients with 51 hips had died. No additional stems were classified as loose radiographically. Femoral revision using a cemented collarless double-taper stem, particularly with a long length stem, and in patients aged > 70 years, continues to yield excellent results up to 20 years post-operatively, including in hips with considerable femoral metaphyseal bone loss.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Fémur/cirugía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Reoperación , Tasa de Supervivencia , Resultado del Tratamiento
15.
Biomed Res Int ; 2015: 758123, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25954757

RESUMEN

Modularity at the head-neck junction of the femoral component in THA became popular as a design feature with advantages of decreasing implant inventory and allowing adjustment of leg length, offset, and soft tissue balancing through different head options. The introduction of a new modular interface to femoral stems that were previously monoblock, or nonmodular, comes with the potential for corrosion at the taper junction through mechanically assisted crevice corrosion. The incidence of revision hip arthroplasty is on the rise and along with improved wear properties of polyethylene and ceramic, use of larger femoral head sizes is becoming increasingly popular. Taper corrosion appears to be related to all of its geometric parameters, material combinations, and femoral head size. This review article discusses the pathogenesis, risk factors, clinical assessment, and management of taper corrosion at the head-neck junction.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cabeza Femoral/metabolismo , Cabeza Femoral/patología , Prótesis de Cadera/efectos adversos , Falla de Prótesis , Corrosión , Femenino , Humanos , Masculino
16.
J Orthop Res ; 21(2): 352-8, 2003 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-12568969

RESUMEN

Most of the clinical studies report the incidence of tarsal coalitions (TC) as less than 1% but they disregard the asymptomatic coalitions. TC have been associated with degenerative arthritic changes. After X-rays, computer tomography (CT) is the most commonly used diagnostic test in the detection of TC. The aims of our study were to establish the incidence of TC; the association between TC and accessory tarsal bones and between TC and tarsal arthritis; and to assess the sensitivity of CT as a diagnostic tool in TC. We performed spiral CT scans of 100 cadaver feet (mean age at death 77.7+/-10.4), which were subsequently dissected. The dissections identified nine non-osseous TC: two talocalcaneal and seven calcaneonavicular. There was no osseous coalition. Tarsal arthritis was identified in 31 cases. Both talocalcaneal coalitions were associated with arthritis while none of the calcaneonavicular coalitions were associated with tarsal arthritis. The CT diagnosed an osseous talocalcaneal coalition and was suspicious of fibrocartilaginous coalitions in eight cases. There was correlation between dissection and CT in two talocalcaneal coalitions and three calcaneonavicular coalitions thus CT identifying 55.5% of the coalitions. CT did not diagnose four non-osseous coalitions and diagnosed errouresly four possible coalitions. In conclusion our study demonstrated that the incidence of non-osseous TC is higher than previously thought (12.72%). The calcaneonavicular coalitions are the most common single type (9.09%) and they do not seem to be associated with arthritic changes in the tarsal bones. Our CT results suggest that spiral CT has a low sensitivity in the detection of non-osseous coalitions and questions if multislice CT should be used routinely when TC are suspected.


Asunto(s)
Deformidades del Pie/diagnóstico , Huesos Tarsianos/anomalías , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Cadáver , Calcáneo/anomalías , Calcáneo/diagnóstico por imagen , Disección , Deformidades del Pie/epidemiología , Hospitales Universitarios , Humanos , Persona de Mediana Edad , Sensibilidad y Especificidad , Australia del Sur/epidemiología , Huesos Tarsianos/diagnóstico por imagen
17.
Bone Joint J ; 96-B(9): 1155-60, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25183583

RESUMEN

Peri-acetabular osteotomy is an established surgical treatment for symptomatic acetabular dysplasia in young adults. An anteroposterior radiograph of the pelvis is commonly used to assess the extent of dysplasia as well as to assess post-operative correction. Radiological prognostic factors include the lateral centre-edge angle, acetabular index, extrusion index and the acetabular version. Standing causes a change in the pelvis tilt which can alter certain radiological measurements relative to the supine position. This article discusses the radiological indices used to assess dysplasia and reviews the effects of patient positioning on these indices with a focus on assessment for a peri-acetabular osteotomy. Intra-operatively, fluoroscopy is commonly used and the implications of using fluoroscopy as a modality to assess the various radiological indices along with the effects of using an anteroposterior or posteroanterior fluoroscopic view are examined. Each of these techniques gives rise to a slightly different image of the pelvis as the final image is sensitive to the position of the pelvis and the projection of the x-ray beam.


Asunto(s)
Acetábulo/diagnóstico por imagen , Luxación Congénita de la Cadera/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Osteotomía , Posicionamiento del Paciente , Acetábulo/cirugía , Fluoroscopía , Luxación Congénita de la Cadera/cirugía , Articulación de la Cadera/cirugía , Humanos , Osteotomía/métodos , Posición Supina , Resultado del Tratamiento , Adulto Joven
18.
Bone Joint J ; 96-B(1): 48-53, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24395310

RESUMEN

We investigated the detailed anatomy of the gluteus maximus, gluteus medius and gluteus minimus and their neurovascular supply in 22 hips in 11 embalmed adult Caucasian human cadavers. This led to the development of a surgical technique for an extended posterior approach to the hip and pelvis that exposes the supra-acetabular ilium and preserves the glutei during revision hip surgery. Proximal to distal mobilisation of the gluteus medius from the posterior gluteal line permits exposure and mobilisation of the superior gluteal neurovascular bundle between the sciatic notch and the entrance to the gluteus medius, enabling a wider exposure of the supra-acetabular ilium. This technique was subsequently used in nine patients undergoing revision total hip replacement involving the reconstruction of nine Paprosky 3B acetabular defects, five of which had pelvic discontinuity. Intra-operative electromyography showed that the innervation of the gluteal muscles was not affected by surgery. Clinical follow-up demonstrated good hip abduction function in all patients. These results were compared with those of a matched cohort treated through a Kocher-Langenbeck approach. Our modified approach maximises the exposure of the ilium above the sciatic notch while protecting the gluteal muscles and their neurovascular bundle.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Músculo Esquelético/inervación , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Nalgas , Electromiografía/métodos , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Músculo Esquelético/anatomía & histología , Músculo Esquelético/irrigación sanguínea , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/prevención & control , Falla de Prótesis , Reoperación/efectos adversos , Reoperación/métodos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
Injury ; 45 Suppl 2: S32-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24857026

RESUMEN

The progress of fracture healing is directly related to an increasing stiffness and strength of the healing fracture. Similarly the weight bearing capacity of a bone directly relates to the mechanical stability of the fracture. Therefore, assessing the progress of fracture repair can be based on the measurement of the mechanical stability of the healing fracture. However, fracture stability is difficult to assess directly due to various obstacles of which shielding of the mechanical properties by the fracture fixation construct is the most relevant one. Several assessment methods have been proposed to overcome these obstacles and to obtain some sort of mechanical surrogate describing the stability of the fracture. The most direct method is the measurement of the flexibility of a fracture under a given external load, which comprises the challenge of accurately measuring the deformation of the bone. Alternative approaches include the measurement of load share between implant and bone by internal or by external sensors. A direct 3 dimensional measurement of bone displacement is provided by radiostereometric analysis which can assess fracture migration and can detect fracture movement under load. More indirect mechanical methods induce cyclic perturbations within the bone and measure the response as a function of healing time. At lower frequencies the perturbations are induced in the form of vibration and at higher frequencies in the form of ultrasonic waves. Both methods provide surrogates for the mechanical properties at the fracture site. Although biomechanical properties of a healing fracture provide a direct and clinically relevant measure for fracture healing, their application will in the near future be limited to clinical studies or research settings.


Asunto(s)
Huesos/fisiología , Curación de Fractura/fisiología , Estrés Mecánico , Soporte de Peso/fisiología , Fenómenos Biomecánicos , Densidad Ósea/fisiología , Humanos , Análisis Radioestereométrico , Telemetría , Ultrasonografía , Vibración/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA