Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Drug Chem Toxicol ; 44(2): 140-147, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30574814

RESUMEN

Shikonin (SH) is used as a red pigment for food coloring and cosmetics, and has cytotoxic activity towards cancer cells. However, due to strong toxicity SH has limited potential as an anticancer drug. Acetylshikonin (ASH) is one of the SH derivatives with promising anticancer potential. In present study, we attempted to evaluate and compare the cytotoxicity of SH and ASH towards a normal cell line (V79) and in addition to evaluate their antigenotoxic activity. The evaluation was made with the use of the set of cytotoxicity assays with V79 line and the micronucleus test in vitro performed using clinafloxacin (CLFX), ethyl methanesulfonate (EMS) as direct genotoxins and cyclophosphamide (CPA) as indirect genotoxin. For CPA and EMS the simultaneous protocol was used and for CLFX three different variants were performed: pretreatment, simultaneous, and post-treatment. A higher cytotoxic effect was observed for SH. The EC50 values obtained for SH were approximately twofold lower compared to that of ASH. Moreover, ASH exhibited an antigenotoxic potential against CPA-induced genotoxicity, whereas SH has no activity. However, ASH increased the EMS-induced genotoxicity, when SH exhibited no effect. Both compounds decreased the genotoxicity of CLFX in pretreatment and simultaneous protocol. Based on the results of the present study it can be concluded that ASH is less cytotoxic than SH to normal cells and has comparable antigenotoxic potential.


Asunto(s)
Antraquinonas/farmacología , Daño del ADN/efectos de los fármacos , Naftoquinonas/farmacología , Animales , Antraquinonas/toxicidad , Línea Celular , Cricetulus , Ciclofosfamida/toxicidad , Metanosulfonato de Etilo/toxicidad , Fluoroquinolonas/toxicidad , Pruebas de Micronúcleos , Naftoquinonas/toxicidad
2.
Int J Mol Sci ; 21(4)2020 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-32102335

RESUMEN

During almost 40 years of use, the micronucleus assay (MN) has become one of the most popular methods to assess genotoxicity of different chemical and physical factors, including ionizing radiation-induced DNA damage. In this minireview, we focus on the position of MN among the other genotoxicity tests, its usefulness in different applications and visibility by international organizations, such as International Atomic Energy Agency, Organization for Economic Co-operation and Development and International Organization for Standardization. In addition, the mechanism of micronuclei formation is discussed. Finally, foreseen directions of the MN development are pointed, such as automation, buccal cells MN and chromothripsis phenomenon.


Asunto(s)
Linfocitos/efectos de los fármacos , Micronúcleos con Defecto Cromosómico/efectos de los fármacos , Pruebas de Micronúcleos/métodos , Pruebas de Mutagenicidad/métodos , Mutágenos/farmacología , Daño del ADN , Predicción , Humanos , Linfocitos/metabolismo , Linfocitos/efectos de la radiación , Micronúcleos con Defecto Cromosómico/efectos de la radiación , Pruebas de Micronúcleos/tendencias , Radiación Ionizante
3.
Biochim Biophys Acta ; 1830(1): 2233-42, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23116821

RESUMEN

BACKGROUND: Investigations concerned the mechanism of HT-29 cells radiosensitization by cis-9,trans-11-conjugated linoleic acid (c9,t11-CLA), a natural component of human diet with proven antitumor activity. METHODS: The cells were incubated for 24h with 70µM c9,t11-CLA and then X-irradiated. The following methods were used: gas chromatography (incorporation of the CLA isomer), flow cytometry (cell cycle), cloning (survival), Western blotting (protein distribution in membrane fractions), and pulse-field gel electrophoresis (rejoining of DNA double-strand breaks). In parallel, DNA-PK activity, γ-H2AX foci numbers and chromatid fragmentation were estimated. Gene expression was analysed by RT-PCR and chromosomal aberrations by the mFISH method. Nuclear accumulation of the EGF receptor (EGFR) was monitored by ELISA. RESULTS AND CONCLUSIONS: C9,t11-CLA sensitized HT-29 cells to X-radiation. This effect was not due to changes in cell cycle progression or DNA-repair-related gene expression. Post-irradiation DSB rejoining was delayed, corresponding with the insufficient DNA-PK activation, although chromosomal aberration frequencies did not increase. Distributions of cholesterol and caveolin-1 in cellular membrane fractions changed. The nuclear EGFR translocation, necessary to increase the DNA-PK activity in response to oxidative stress, was blocked. We suppose that c9,t11-CLA modified the membrane structure, thus disturbing the intracellular EGFR transport and the EGFR-dependent pro-survival signalling, both functionally associated with lipid raft properties. GENERAL SIGNIFICANCE: The results point to the importance of the cell membrane interactions with the nucleus after injury inflicted by X -rays. Compounds like c9,t11-CLA, that specifically alter membrane properties, could be used to develop new anticancer strategies.


Asunto(s)
Adenocarcinoma/radioterapia , Neoplasias Colorrectales/radioterapia , Microdominios de Membrana/metabolismo , Tolerancia a Radiación/efectos de los fármacos , Fármacos Sensibilizantes a Radiaciones/farmacología , Adenocarcinoma/metabolismo , Adenocarcinoma/patología , Línea Celular Tumoral , Neoplasias Colorrectales/metabolismo , Neoplasias Colorrectales/patología , Roturas del ADN de Doble Cadena/efectos de los fármacos , Roturas del ADN de Doble Cadena/efectos de la radiación , Regulación Neoplásica de la Expresión Génica/efectos de los fármacos , Regulación Neoplásica de la Expresión Génica/efectos de la radiación , Humanos , Ácidos Linoleicos Conjugados , Microdominios de Membrana/patología , Tolerancia a Radiación/efectos de la radiación , Rayos X
4.
Int J Radiat Biol ; 97(7): 888-905, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33970757

RESUMEN

PURPOSE: In case of a mass-casualty radiological event, there would be a need for networking to overcome surge limitations and to quickly obtain homogeneous results (reported aberration frequencies or estimated doses) among biodosimetry laboratories. These results must be consistent within such network. Inter-laboratory comparisons (ILCs) are widely accepted to achieve this homogeneity. At the European level, a great effort has been made to harmonize biological dosimetry laboratories, notably during the MULTIBIODOSE and RENEB projects. In order to continue the harmonization efforts, the RENEB consortium launched this intercomparison which is larger than the RENEB network, as it involves 38 laboratories from 21 countries. In this ILC all steps of the process were monitored, from blood shipment to dose estimation. This exercise also aimed to evaluate the statistical tools used to compare laboratory performance. MATERIALS AND METHODS: Blood samples were irradiated at three different doses, 1.8, 0.4 and 0 Gy (samples A, C and B) with 4-MV X-rays at 0.5 Gy min-1, and sent to the participant laboratories. Each laboratory was requested to blindly analyze 500 cells per sample and to report the observed frequency of dicentric chromosomes per metaphase and the corresponding estimated dose. RESULTS: This ILC demonstrates that blood samples can be successfully distributed among laboratories worldwide to perform biological dosimetry in case of a mass casualty event. Having achieved a substantial harmonization in multiple areas among the RENEB laboratories issues were identified with the available statistical tools, which are not capable to advantageously exploit the richness of results of a large ILCs. Even though Z- and U-tests are accepted methods for biodosimetry ILCs, setting the number of analyzed metaphases to 500 and establishing a tests' common threshold for all studied doses is inappropriate for evaluating laboratory performance. Another problem highlighted by this ILC is the issue of the dose-effect curve diversity. It clearly appears that, despite the initial advantage of including the scoring specificities of each laboratory, the lack of defined criteria for assessing the robustness of each laboratory's curve is a disadvantage for the 'one curve per laboratory' model. CONCLUSIONS: Based on our study, it seems relevant to develop tools better adapted to the collection and processing of results produced by the participant laboratories. We are confident that, after an initial harmonization phase reached by the RENEB laboratories, a new step toward a better optimization of the laboratory networks in biological dosimetry and associated ILC is on the way.


Asunto(s)
Laboratorios , Radiometría , Aberraciones Cromosómicas/efectos de la radiación , Humanos , Exposición a la Radiación , Reproducibilidad de los Resultados
5.
Int J Radiat Biol ; 97(9): 1181-1198, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34138666

RESUMEN

PURPOSE: Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. MATERIALS AND METHODS: For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. RESULTS: The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. CONCLUSIONS: The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.


Asunto(s)
Cromosomas Humanos/genética , Cromosomas Humanos/efectos de la radiación , Radiometría , Aberraciones Cromosómicas/efectos de la radiación , Humanos , Exposición a la Radiación/análisis , Estudios Retrospectivos
6.
Mutat Res ; 701(1): 52-9, 2010 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-20298802

RESUMEN

The purpose of the present study was to investigate as to what extent differences in the linear energy transfer (LET) are reflected at the chromosomal level. For this study human lymphocytes were exposed to 9.5 MeV/u C-ions (1 or 2 Gy, LET=175 keV/microm) or X-rays (1-6 Gy), harvested at 48, 72 or 96 h post-irradiation and aberrations were scored in first cycle metaphases using 24 color fluorescence in situ hybridization (mFISH). Additionally, in selected samples aberrations were measured in prematurely condensed G2-phase cells. Analysis of the time-course of aberrations in first cycle metaphases showed a stable yield of simple and complex exchanges after X-ray irradiation. In contrast, after C-ion exposure the yields profoundly increased with harvesting time complicating the estimation of the frequency of aberrations produced by high LET particles within the entire cell population. This is especially true for the yield of complex exchanges. Complex aberrations dominate the aberration spectrum produced by C-ions. Their fraction was about 50% for the two measured doses. In contrast, isodoses of X-rays induced smaller proportions of complex aberrations (i.e. 5% and 15%, respectively). For both radiation qualities the fraction of complexes did not change with harvesting time. As expected from the different dose deposition of high and low LET radiation, complex exchanges produced by high LET C-ions involved more breaks and more chromosomes than those induced by isodoses of X-rays. Noteworthy, C-ions but not X-rays induced a small number of complex chromatid-isochromatid exchanges that are not expected for cells exposed in the G0-phase. The results obtained so far for cells arrested in G2-phase confirm these patterns. Altogether our data show that the increased effectiveness of C-ions for the induction of aberrations in first cycle cells is determined by complex exchanges, whereas for simple exchanges the relative biological effectiveness is about one.


Asunto(s)
Aberraciones Cromosómicas , Iones Pesados , Mitosis , Rayos X , Carbono , Fase G2 , Humanos , Transferencia Lineal de Energía , Linfocitos/efectos de la radiación , Efectividad Biológica Relativa
7.
Cardiovasc Revasc Med ; 9(3): 149-55, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18606378

RESUMEN

BACKGROUND: Restenosis is the complete occlusion of the blood vessel leading to such complications as ischemia/angina, myocardial infarction, and death. It can be managed by endovascular brachytherapy with both gamma and beta sources. Endovascular brachytherapy is performed worldwide on several thousands of cases per year. The gamma-emitter 192Ir as well as the beta-emitters 32P and 90Sr are mainly used. The dose to the occluded endothelial wall is 20 Gy. Interestingly, no information with respect to the dose absorbed by the blood during the course of the treatment exists. The aim of the present investigation was to verify if the micronucleus test is suitable to detect the dose absorbed by lymphocytes in the course of endovascular brachytherapy with 32P. MATERIALS AND METHODS: Blood was drawn from 16 patients immediately before and 1 day after the treatment. Frequencies of micronuclei were assessed. In order to ensure that the micronuclei did not arise due to fluoroscopy or reperfusion, we analyzed lymphocytes of 16 control patients who underwent interventional cardiology with balloon angioplasty only. RESULTS AND CONCLUSIONS: Enhanced frequencies of micronuclei were observed in lymphocytes of some donors following brachytherapy. No correlation could be detected between the level of induced micronuclei and the absorbed dose. Also, no effect of fluoroscopy or reperfusion was seen. Thus, although brachytherapy of restenosis with 32P leads to weak enhancement of the micronucleus frequency in lymphocytes, the effect was not seen in all patients; the reason for this heterogeneous response remains to be elucidated.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Braquiterapia/métodos , Reestenosis Coronaria/radioterapia , Linfocitos/ultraestructura , Micronúcleo Germinal/efectos de la radiación , Células Cultivadas , Reestenosis Coronaria/sangre , Estudios de Seguimiento , Humanos , Linfocitos/efectos de la radiación , Micronúcleo Germinal/ultraestructura , Resultado del Tratamiento
8.
J Photochem Photobiol B ; 178: 201-210, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29156348

RESUMEN

The development of innovative solutions in photosafety of photolabile pharmaceutical products may help to reduce the adverse effects of these products, caused by light exposure. Providing new data in this area of study is particularly important in case of drugs applied topically on sensitive organs such as eyes. The main goal of this research is to investigate whether two potential excipients, namely: p-coumaric acid and benzophenone-4, affect the photodegradation, phototoxicity and photogenotoxicity of water solutions of four fluoroquinolones: ciprofloxacin, lomefloxacin, fleroxacin and clinafloxacin. We conducted a set of bioassays combined with the application of high-performance liquid chromatography and mass spectrometry techniques. The significant reduction of phototoxic and photogenotoxic abilities was evaluated in mixtures with ciprofloxacin and p-coumaric acid by using the umu test with Salmonella typhimurium TA1535/pSK1002, the methylthiazol tetrazolium reduction assay, and the micronucleus assay with the V79 cell line. In the bacterial assay the opposite effect was observed for the formulation with lomefloxacin and p-coumaric acid. This may be explained by the significant differences in the profile of the lomefloxacin photodegradation products. Further, the photoprotective and antiphotomutagenic abilities of ciprofloxacin mixed with benzophenone-4 were assessed. Promising results obtained in compositions with ciprofloxacin may be a basis for further research. Nevertheless, the increase in the DNA damage potential in mixtures with p-coumaric acid and two other antibiotics shows the importance of the safety evaluation of such innovative combinations.


Asunto(s)
Composición de Medicamentos , Fluoroquinolonas/química , Sustancias Protectoras/química , Animales , Línea Celular , Supervivencia Celular/efectos de los fármacos , Supervivencia Celular/efectos de la radiación , Ácidos Cumáricos , Cricetinae , Cricetulus , Daño del ADN/efectos de los fármacos , Daño del ADN/efectos de la radiación , Fleroxacino/química , Fleroxacino/toxicidad , Fluoroquinolonas/toxicidad , Pruebas de Micronúcleos , Fotólisis/efectos de los fármacos , Fotólisis/efectos de la radiación , Propionatos/química , Sustancias Protectoras/farmacología , Salmonella typhimurium/efectos de los fármacos , Salmonella typhimurium/genética , Rayos Ultravioleta
9.
Int J Radiat Biol ; 94(6): 551-557, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29668347

RESUMEN

PURPOSE: Low temperature at exposure has been shown to act in a radioprotective manner at the level of cytogenetic damage. It was suggested to be due to an effective transformation of DNA damage to chromosomal damage at low temperature. The purpose of the study was to analyze the kinetics of aberration formation during the first hours after exposing human peripheral blood lymphocytes to ionizing radiation at 0.8 °C and 37 °C. MATERIALS AND METHODS: To this end, we applied the technique of premature chromosome condensation. In addition, DNA damage response was analyzed by measuring the levels of phosphorylated DNA damage responsive proteins ATM, DNA-PK and p53 and mRNA levels of the radiation-responsive genes BBC3, FDXR, GADD45A, XPC, MDM2 and CDKN1A. RESULTS: A consistently lower frequency of chromosomal breaks was observed in cells exposed at 0.8 °C as compared to 37 °C already after 30 minutes postexposure. This effect was accompanied by elevated levels of phosphorylated ATM and DNA-PK proteins and a reduced immediate level of phosphorylated p53 and of the responsive genes. CONCLUSIONS: Low temperature at exposure appears to promote DNA repair leading to reduced transformation of DNA damage to chromosomal aberrations.


Asunto(s)
Frío , Daño del ADN , Linfocitos/metabolismo , Linfocitos/efectos de la radiación , Adulto , Animales , Células CHO , Cromosomas/genética , Cromosomas/efectos de la radiación , Cricetulus , Femenino , Regulación de la Expresión Génica/efectos de la radiación , Humanos , ARN Mensajero/genética , ARN Mensajero/metabolismo
10.
Int J Radiat Biol ; 93(1): 127-135, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27572921

RESUMEN

PURPOSE: Reliable dose estimation is an important factor in appropriate dosimetric triage categorization of exposed individuals to support radiation emergency response. MATERIALS AND METHODS: Following work done under the EU FP7 MULTIBIODOSE and RENEB projects, formal methods for defining uncertainties on biological dose estimates are compared using simulated and real data from recent exercises. RESULTS: The results demonstrate that a Bayesian method of uncertainty assessment is the most appropriate, even in the absence of detailed prior information. The relative accuracy and relevance of techniques for calculating uncertainty and combining assay results to produce single dose and uncertainty estimates is further discussed. CONCLUSIONS: Finally, it is demonstrated that whatever uncertainty estimation method is employed, ignoring the uncertainty on fast dose assessments can have an important impact on rapid biodosimetric categorization.


Asunto(s)
Algoritmos , Bioensayo/métodos , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Triaje/métodos , Teorema de Bayes , Europa (Continente) , Humanos , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Int J Radiat Biol ; 93(1): 30-35, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27705052

RESUMEN

PURPOSE: In the framework of RENEB, several biodosimetry exercises were conducted analyzing different endpoints. Among them, the analysis of translocations is considered the most useful method for retrospective biodosimetry due to the relative stability of their frequency with post irradiation time. The aim of this study was to harmonize the accuracy of translocation-based biodosimetry within the RENEB consortium. MATERIALS AND METHODS: An initial telescoring exercise analyzing FISH metaphase images was done to harmonize chromosome aberration descriptions. Then two blind intercomparison exercises (IE) were performed, by sending irradiated blood samples to each partner. Samples were cultured and stained by each partner using their standard protocol and translocation frequency was used to produce dose estimates. RESULTS: The coefficient of variation in the 1st IE (CV = 0.34) was higher than in the 2nd IE (CV = 0.16 and 0.23 in the two samples analyzed), for the genomic frequency of total translocations. Z-score analysis revealed that eight out of 10 and 17 out of 20 dose estimates were satisfactory in the 1st and 2nd IE, respectively. CONCLUSIONS: The results obtained indicate that, despite the problems identified in few partners, which can be corrected, the RENEB consortium is able to carry out retrospective biodosimetry analyzing the frequency of translocations by FISH.


Asunto(s)
Bioensayo/métodos , Hibridación Fluorescente in Situ/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Translocación Genética/efectos de la radiación , Bioensayo/normas , Europa (Continente) , Humanos , Hibridación Fluorescente in Situ/normas , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Translocación Genética/genética
12.
Int J Radiat Biol ; 93(1): 48-57, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27813725

RESUMEN

PURPOSE: Dose assessment intercomparisons within the RENEB network were performed for triage biodosimetry analyzing G0-lymphocyte PCC for harmonization, standardization and optimization of the PCC assay. MATERIALS AND METHODS: Comparative analysis among different partners for dose assessment included shipment of PCC-slides and captured images to construct dose-response curves for up to 6 Gy γ-rays. Accident simulation exercises were performed to assess the suitability of the PCC assay by detecting speed of analysis and minimum number of cells required for categorization of potentially exposed individuals. RESULTS: Calibration data based on Giemsa-stained fragments in excess of 46 PCC were obtained by different partners using galleries of PCC images for each dose-point. Mean values derived from all scores yielded a linear dose-response with approximately 4 excess-fragments/cell/Gy. To unify scoring criteria, exercises were carried out using coded PCC-slides and/or coded irradiated blood samples. Analysis of samples received 24 h post-exposure was successfully performed using Giemsa staining (1 excess-fragment/cell/Gy) or centromere/telomere FISH-staining for dicentrics. CONCLUSIONS: Dose assessments by RENEB partners using appropriate calibration curves were mostly in good agreement. The PCC assay is quick and reliable for whole- or partial-body triage biodosimetry by scoring excess-fragments or dicentrics in G0-lymphocytes. Particularly, analysis of Giemsa-stained excess PCC-fragments is simple, inexpensive and its automation could increase throughput and scoring objectivity of the PCC assay.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas/efectos de la radiación , Pruebas de Micronúcleos/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Bioensayo/normas , Europa (Continente) , Humanos , Linfocitos/citología , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Fase de Descanso del Ciclo Celular/genética , Fase de Descanso del Ciclo Celular/efectos de la radiación , Sensibilidad y Especificidad
13.
Int J Radiat Biol ; 93(1): 118-126, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27735728

RESUMEN

PURPOSE: In the frame of the QA program of RENEB, an inter-laboratory comparison (ILC) of calibration sources used in biological dosimetry was achieved to investigate the influence of calibration practices and protocols on the results of the dose estimation performance as a first step to harmonization and standardization of dosimetry and irradiation practices in the European biological dosimetry network. MATERIALS AND METHODS: Delivered doses by irradiation facilities used by RENEB partners were determined with EPR/alanine dosimetry system. Dosimeters were irradiated in the same conditions as blood samples. A short survey was also performed to collect the information needed for the data analysis and evaluate the diversity of practices. RESULTS: For most of partners the deviation of delivered dose from the targeted dose remains below 10%. Deviations larger than 10% were observed for five facilities out of 21. Origins of the largest discrepancies were identified. Correction actions were evaluated as satisfactory. The re-evaluation of some ILC results for the fluorescence in situ hybridization (FISH) and premature chromosome condensation (PCC) assays has been performed leading to an improvement of the overall performances. CONCLUSIONS: This work has shown the importance of dosimetry in radiobiology studies and the needs of harmonization, standardization in irradiation and dosimetry practices and educational training for biologists using ionizing radiation.


Asunto(s)
Calibración/normas , Análisis Citogenético/normas , Laboratorios/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/normas , Exposición a la Radiación/análisis , Monitoreo de Radiación/normas , Análisis Citogenético/estadística & datos numéricos , Europa (Continente) , Humanos , Laboratorios/normas , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Monitoreo de Radiación/estadística & datos numéricos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Int J Radiat Biol ; 93(1): 36-47, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27673504

RESUMEN

PURPOSE: In the framework of the 'Realizing the European Network of Biodosimetry' (RENEB) project, two intercomparison exercises were conducted to assess the suitability of an optimized version of the cytokinesis-block micronucleus assay, and to evaluate the capacity of a large laboratory network performing biodosimetry for radiation emergency triages. Twelve European institutions participated in the first exercise, and four non-RENEB labs were added in the second one. MATERIALS AND METHODS: Irradiated blood samples were shipped to participating labs, whose task was to culture these samples and provide a blind dose estimate. Micronucleus analysis was performed by automated, semi-automated and manual procedures. RESULTS: The dose estimates provided by network laboratories were in good agreement with true administered doses. The most accurate estimates were reported for low dose points (≤ 0.94 Gy). For higher dose points (≥ 2.7 Gy) a larger variation in estimates was observed, though in the second exercise the number of acceptable estimates increased satisfactorily. Higher accuracy was achieved with the semi-automated method. CONCLUSION: The results of the two exercises performed by our network demonstrate that the micronucleus assay is a useful tool for large-scale radiation emergencies, and can be successfully implemented within a large network of laboratories.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas/efectos de la radiación , Pruebas de Micronúcleos/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Bioensayo/normas , Europa (Continente) , Humanos , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Int J Radiat Biol ; 93(1): 110-117, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27547893

RESUMEN

PURPOSE: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. MATERIALS AND METHODS: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. RESULTS: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. CONCLUSIONS: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.


Asunto(s)
Bioensayo/métodos , Análisis Citogenético/métodos , Internet/organización & administración , Linfocitos/efectos de la radiación , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Europa (Continente) , Humanos , Laboratorios/estadística & datos numéricos , Linfocitos/citología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Int J Radiat Biol ; 93(1): 136-141, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27557790

RESUMEN

PURPOSE: To identify and assess, among the participants in the RENEB (Realizing the European Network of Biodosimetry) project, the emergency preparedness, response capabilities and resources that can be deployed in the event of a radiological or nuclear accident/incident affecting a large number of individuals. These capabilities include available biodosimetry techniques, infrastructure, human resources (existing trained staff), financial and organizational resources (including the role of national contact points and their articulation with other stakeholders in emergency response) as well as robust quality control/assurance systems. MATERIALS AND METHODS: A survey was prepared and sent to the RENEB partners in order to acquire information about the existing, operational techniques and infrastructure in the laboratories of the different RENEB countries and to assess the capacity of response in the event of radiological or nuclear accident involving mass casualties. The survey focused on several main areas: laboratory's general information, country and staff involved in biological and physical dosimetry; retrospective assays used, the number of assays available per laboratory and other information related to biodosimetry and emergency preparedness. Following technical intercomparisons amongst RENEB members, an update of the survey was performed one year later concerning the staff and the available assays. CONCLUSIONS: The analysis of RENEB questionnaires allowed a detailed assessment of existing capacity of the RENEB network to respond to nuclear and radiological emergencies. This highlighted the key importance of international cooperation in order to guarantee an effective and timely response in the event of radiological or nuclear accidents involving a considerable number of casualties. The deployment of the scientific and technical capabilities existing within the RENEB network members seems mandatory, to help other countries with less or no capacity for biological or physical dosimetry, or countries overwhelmed in case of a radiological or nuclear accident involving a large number of individuals.


Asunto(s)
Investigación Biomédica/organización & administración , Planificación en Desastres/organización & administración , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa , Administración de la Seguridad/organización & administración , Europa (Continente) , Modelos Organizacionales , Radiobiología/organización & administración
17.
Int J Radiat Biol ; 93(1): 2-14, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27707245

RESUMEN

PURPOSE: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. RESULTS: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. CONCLUSIONS: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.


Asunto(s)
Bioensayo/métodos , Planificación en Desastres/organización & administración , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Administración de la Seguridad/organización & administración , Urgencias Médicas , Europa (Continente) , Humanos , Objetivos Organizacionales , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Liberación de Radiactividad Peligrosa/prevención & control
18.
Int J Radiat Biol ; 93(1): 20-29, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27766931

RESUMEN

PURPOSE: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. MATERIALS AND METHODS: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. RESULTS: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. CONCLUSIONS: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas/efectos de la radiación , Pruebas de Micronúcleos/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Bioensayo/normas , Europa (Continente) , Humanos , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Int J Radiat Biol ; 81(10): 741-9, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16449081

RESUMEN

PURPOSE: To investigate if deviations from DNA-proportional distribution of radiation-induced chromosomal aberrations are individually variable. MATERIALS AND METHODS: Peripheral blood lymphocytes were collected from seven healthy donors and exposed to different doses of gamma rays. Chromosomes 2, 8 and 14 were painted in different colors and aberrations scored with the help of an image-analysis system. RESULTS: Chromosome 2 was generally less sensitive than expected on the basis of DNA-proportional distribution and the extent of inter-donor variability was minimal. A higher than expected frequency of aberrations was found in chromosome 14 of five donors, while a higher than expected frequency of aberrations was found in chromosome 8 of two donors. CONCLUSIONS: Inter-donor variability may explain some of the controversies regarding the inter-chromosomal distribution of radiation-induced aberrations.


Asunto(s)
Aberraciones Cromosómicas/efectos de la radiación , Cromosomas Humanos Par 14/efectos de la radiación , Cromosomas Humanos Par 2/efectos de la radiación , Cromosomas Humanos Par 8/efectos de la radiación , Adulto , Técnicas de Cultivo de Célula , ADN/análisis , Daño del ADN , Femenino , Humanos , Linfocitos/efectos de la radiación , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
20.
Radiat Res ; 184(1): 95-104, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26121226

RESUMEN

Biodosimetric methods used to measure the effects of radiation are critical for estimating the health risks to irradiated individuals or populations. The direct measurement of radiation-induced γ-H2AX foci in peripheral blood lymphocytes is one approach that provides a useful end point for triage. Despite the documented advantages of the γ-H2AX assay, there is considerable variation among laboratories regarding foci formation in the same exposure conditions and cell lines. Taking this into account, the goal of our study was to evaluate the influence of different blood processing parameters on the frequency of γ-H2AX foci and optimize a small blood volume protocol for the γ-H2AX assay, which simulates the finger prick blood collection method. We found that the type of fixative, temperature and blood processing time markedly affect the results of the γ-H2AX assay. In addition, we propose a protocol for the γ-H2AX assay that may serve as a potential guideline in the event of large-scale radiation incidents.


Asunto(s)
Conservación de la Sangre , Recolección de Muestras de Sangre , Histonas/análisis , Linfocitos/efectos de la radiación , Adulto , Femenino , Humanos , Péptidos y Proteínas de Señalización Intracelular/análisis , Masculino , Persona de Mediana Edad , Temperatura , Proteína 1 de Unión al Supresor Tumoral P53
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA