Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
ACS Appl Bio Mater ; 4(1): 387-391, 2021 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-35014289

RESUMEN

Multiple sclerosis is complex and heterogeneous. Better tools are needed to be able to monitor this disease among individuals, but blood-based biomarkers are often too rare to profile. In this work, we developed antigen-specific biomaterials to replicate the central nervous system niche where multiple sclerosis biomarkers are amplified. We incorporated mouse brain homogenate into a microporous gelatin methacrylate network. Homogenate-containing biomaterials differentially stimulated cells and led to the marked amplification of disease-relevant, antigen-specific B cells. These results demonstrate that biomaterials containing primary tissue homogenate retain antigen specificity and may be a useful tool for decoding human autoimmunity.


Asunto(s)
Antígenos/metabolismo , Materiales Biocompatibles/química , Encéfalo/metabolismo , Animales , Antígenos/química , Autoinmunidad , Linfocitos B/citología , Linfocitos B/inmunología , Linfocitos B/metabolismo , Antígeno B7-2/metabolismo , Encefalomielitis Autoinmune Experimental/metabolismo , Encefalomielitis Autoinmune Experimental/patología , Gelatina/química , Ratones , Proteína Proteolipídica de la Mielina/química , Proteína Proteolipídica de la Mielina/inmunología , Proteína Proteolipídica de la Mielina/metabolismo , Fragmentos de Péptidos/química , Fragmentos de Péptidos/inmunología , Fragmentos de Péptidos/metabolismo , Bazo/citología , Bazo/metabolismo
2.
Macromol Biosci ; 20(12): e2000251, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32924274

RESUMEN

Designing an in vitro model of the tumor extracellular microenvironment to screen intratumoral drugs is an active challenge. As recent clinical successes of human intratumoral therapies stimulate research on intratumoral delivery, a need for a 3D tumor model to screen intratumoral therapies arises. When injecting the drug formulation directly into the tumor, the biophysics affecting intratumoral retention must be considered; especially for biologic therapies, which may be dominated by extracellular transport mechanisms. Fibrotic regions in solid tumors are typically rich in collagen I fibers. Using shear rheology, head and neck tumors with higher collagen density show a higher stiffness. Similarly, the stiffness of the hyaluronic acid (HA) hydrogel models is increased by adding collagen fibers to model the bulk biomechanical properties of solid tumors. HA hydrogels are then used as intratumoral injection site simulators to model in vitro the retention of glatiramer acetate (GA) and polyethylene glycol (PEG) administered intratumorally. Both compounds are also injected in murine tumors and retention is studied ex vivo for comparison. Retention of GA in the hydrogels is significantly longer than PEG, analogous to the solid tumors, suggesting the utility of HA hydrogels with collagen I fibers for screening extracellular drug transport after intratumoral administration.


Asunto(s)
Materiales Biocompatibles/farmacología , Sistemas de Liberación de Medicamentos , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Hidrogeles/farmacología , Animales , Materiales Biocompatibles/metabolismo , Línea Celular Tumoral , Portadores de Fármacos/química , Portadores de Fármacos/farmacología , Composición de Medicamentos , Acetato de Glatiramer/química , Neoplasias de Cabeza y Cuello/metabolismo , Humanos , Ácido Hialurónico/química , Hidrogeles/química , Ratones , Polietilenglicoles/farmacología , Ensayos Antitumor por Modelo de Xenoinjerto
3.
Front Immunol ; 11: 603029, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33537031

RESUMEN

A synthetic peptide, K-PLP, consisting of 11-unit poly-lysine (K11) linked via polyethylene glycol (PEG) to proteolipid protein epitope (PLP) was synthesized, characterized, and evaluated for efficacy in ameliorating experimental autoimmune encephalomyelitis (EAE) induced by PLP. K-PLP was designed to mimic the cationic nature of the relapsing-remitting multiple sclerosis treatment, glatiramer acetate (GA). With a pI of ~10, GA is able to form visible aggregates at the site of injection via electrostatic interactions with the anionic extracellular matrix. Aggregation further facilitates the retention of GA at the site of injection and draining lymph nodes, which may contribute to its mechanism of action. K-PLP with a pI of ~11, was found to form visible aggregates in the presence of glycosaminoglycans and persist at the injection site and draining lymph nodes in vivo, similar to GA. Additionally, EAE mice treated with K-PLP showed significant inhibition of clinical symptoms compared to free poly-lysine and to PLP, which are the components of K-PLP. The ability of the poly-lysine motif to retain PLP at the injection site, which increased the local exposure of PLP to immune cells may be an important factor affecting drug efficacy.


Asunto(s)
Autoantígenos/administración & dosificación , Encefalomielitis Autoinmune Experimental/tratamiento farmacológico , Acetato de Glatiramer/administración & dosificación , Inmunosupresores/administración & dosificación , Imitación Molecular , Péptidos/administración & dosificación , Animales , Autoantígenos/química , Autoantígenos/metabolismo , Células Cultivadas , Encefalomielitis Autoinmune Experimental/inmunología , Encefalomielitis Autoinmune Experimental/metabolismo , Femenino , Acetato de Glatiramer/metabolismo , Inmunosupresores/metabolismo , Inyecciones Subcutáneas , Ganglios Linfáticos/efectos de los fármacos , Ganglios Linfáticos/inmunología , Ganglios Linfáticos/metabolismo , Ratones , Péptidos/síntesis química , Péptidos/metabolismo , Agregado de Proteínas , Bazo/efectos de los fármacos , Bazo/inmunología , Bazo/metabolismo , Distribución Tisular
4.
Adv Drug Deliv Rev ; 165-166: 105-116, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32325104

RESUMEN

Antigen-specific immunotherapies (ASIT) present compelling potential for introducing precision to the treatment of autoimmune diseases where nonspecific, global immunosuppression is currently the only treatment option. Central to ASIT design is the delivery of autoantigen, which parallels allergy desensitization approaches. Clinical success in tolerizing allergen-specific responses spans longer than a century, but autoimmune ASITs have yet to see an FDA-approved breakthrough. Allergens and autoantigens differ substantially in physicochemical properties, and these discrepancies influence the nature of their interactions with the immune system. Approved allergen-specific immunotherapies are typically administered as water soluble, neutrally charged protein fractions from 10 to 70 kDa. Conversely, autoantigens are native proteins that exhibit wide-ranging sizes, solubilities, and charges that render them susceptible to immunogenicity. To translate the success of allergen hyposensitization to ASIT, delivery strategies may be necessary to effectively format autoantigens, guide biodistribution, and engage appropriate immune mechanisms.


Asunto(s)
Autoantígenos/inmunología , Sistemas de Liberación de Medicamentos/métodos , Inmunoterapia/métodos , Alérgenos/química , Alérgenos/farmacología , Enfermedades Autoinmunes/fisiopatología , Transporte Biológico/fisiología , Desensibilización Inmunológica/métodos , Vías de Administración de Medicamentos , Humanos
5.
Biomaterials ; 222: 119440, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31450159

RESUMEN

Relapsing-remitting patterns of many autoimmune diseases such as multiple sclerosis (MS) are perpetuated by a recurring circuit of adaptive immune cells that amplify in secondary lymphoid organs (SLOs) and traffic to compartments where antigen is abundant to elicit damage. Some of the most effective immunotherapies impede the migration of immune cells through this circuit, however, broadly suppressing immune cell migration can introduce life-threatening risks for patients. We developed antigen-specific immune decoys (ASIDs) to mimic tissues targeted in autoimmunity and selectively intercept autoimmune cells to preserve host tissue. Using Experimental Autoimmune Encephalomyelitis (EAE) as a model, we conjugated autoantigen PLP139-151 to a microporous collagen scaffold. By subcutaneously implanting ASIDs after induction but prior to the onset of symptoms, mice were protected from paralysis. ASID implants were rich with autoimmune cells, however, reactivity to cognate antigen was substantially diminished and apoptosis was prevalent. ASID-implanted mice consistently exhibited engorged spleens when disease normally peaked. In addition, splenocyte antigen-presenting cells were highly activated in response to PLP rechallenge, but CD3+ and CD19 + effector subsets were significantly decreased, suggesting exhaustion. ASID-implanted mice never developed EAE relapse symptoms even though the ASID material had long since degraded, suggesting exhausted autoimmune cells did not recover functionality. Together, data suggested ASIDs were able to sequester and exhaust immune cells in an antigen-specific fashion, thus offering a compelling approach to inhibit the migration circuit underlying autoimmunity.


Asunto(s)
Enfermedades Autoinmunes/inmunología , Autoinmunidad/fisiología , Animales , Células Presentadoras de Antígenos/inmunología , Células Presentadoras de Antígenos/metabolismo , Autoantígenos/inmunología , Enfermedades Autoinmunes/terapia , Encefalomielitis Autoinmune Experimental/inmunología , Encefalomielitis Autoinmune Experimental/terapia , Femenino , Tolerancia Inmunológica , Inmunoterapia , Ratones
6.
J Control Release ; 293: 36-47, 2019 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-30414463

RESUMEN

Glatiramer acetate (GA) is widely prescribed for the treatment of relapsing-remitting multiple sclerosis, however, the mechanism of action is still not fully understood. We investigated the structural properties of GA and examined alterations to the drug upon injection into the subcutaneous space. First, a variety of biophysical characterization techniques were employed to characterize GA in solution. GA was found to exist as alpha helices in solution with a hydrodynamic radius of ~3 nm in size. To simulate GA behavior at the site of injection, GA was injected into a solution of 1.5 MDa hyaluronic acid (HA). Visible aggregates were observed immediately upon injection and subsequent testing indicated aggregation was driven by electrostatic interactions between the positively-charged GA and negatively-charged HA. In vivo testing confirmed GA formed spherical particles in the nano- to micrometer size range, suggesting this mechanism contributes to persistence at the injection site and in draining lymph nodes. The aggregates were found to associate with glycosaminoglycans, suggesting an electrostatic mechanism of induced aggregation like the simulated injection. These novel observations may help explain the complex immunomodulatory mechanisms of GA and adverse injection site reactions seen in patients.


Asunto(s)
Acetato de Glatiramer , Inmunosupresores , Animales , Femenino , Acetato de Glatiramer/administración & dosificación , Acetato de Glatiramer/química , Acetato de Glatiramer/farmacocinética , Ácido Hialurónico/química , Inmunosupresores/administración & dosificación , Inmunosupresores/química , Inmunosupresores/farmacocinética , Inyecciones Subcutáneas , Ganglios Linfáticos/metabolismo , Ratones , Músculo Esquelético/metabolismo , Nanopartículas , Electricidad Estática
7.
Vaccine ; 36(38): 5738-5746, 2018 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-30107994

RESUMEN

Determination of protein concentration in vaccines containing aluminum salt adjuvant typically necessitates desorption of the protein prior to analysis. Here we describe a method based on the intrinsic fluorescence of tyrosine and tryptophan that requires no desorption of proteins. Adjuvanted formulations of three model Bordetella pertussis antigens were excited at 280 nm and their emission spectra collected from 290 to 400 nm. Emission spectra of protein antigens in the presence of aluminum salt adjuvants were able to be detected, the effects of adjuvants on the spectra were analyzed, and linear regressions were calculated. The fluorescence method proved to be very sensitive with a limit of quantification between 0.4 and 4.4 µg/mL and limit of linearity between 100 and 200 µg/mL, across the formulations tested. The fluorescence method was found to be influenced by adjuvant presence, type of adjuvant, adjuvant concentration, buffer and pH conditions. The method also demonstrated ability to monitor the percent adsorption of antigens to the adjuvants. Furthermore, intrinsic fluorescence showed good correlation with micro-Kjeldahl elemental assay in quantifying protein concentration. Being a non-invasive, quick and sensitive method, intrinsic fluorescence has the potential to be utilized as a high throughput tool for vaccine development and conceivably implemented in-line, using in-line fluorimeters, to monitor antigen concentration during formulation processing.


Asunto(s)
Adyuvantes Inmunológicos/química , Hidróxido de Aluminio/química , Antígenos Bacterianos/análisis , Proteínas Bacterianas/análisis , Bordetella pertussis/química , Mediciones Luminiscentes/métodos , Adhesinas Bacterianas/análisis , Adhesinas Bacterianas/química , Proteínas de la Membrana Bacteriana Externa/análisis , Proteínas de la Membrana Bacteriana Externa/química , Fimbrias Bacterianas/química , Fluorescencia , Humanos , Triptófano/química , Tirosina/química , Vacunas/inmunología , Factores de Virulencia de Bordetella/análisis , Factores de Virulencia de Bordetella/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA