Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Magn Reson ; 23(1): 51, 2021 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-33980249

RESUMEN

BACKGROUND: Chronic type B aortic dissection (TBAD) is associated with poor long-term outcome, and accurate risk stratification tools remain lacking. Pressurization of the false lumen (FL) has been recognized as central in promoting aortic growth. Several surrogate imaging-based metrics have been proposed to assess FL hemodynamics; however, their relationship to enlarging aortic dimensions remains unclear. We investigated the association between aortic growth and three cardiovascular magnetic resonance (CMR)-derived metrics of FL pressurization: false lumen ejection fraction (FLEF), maximum systolic deceleration rate (MSDR), and FL relative pressure (FL ΔPmax). METHODS: CMR/CMR angiography was performed in 12 patients with chronic dissection of the descending thoracoabdominal aorta, including contrast-enhanced CMR angiography and time-resolved three-dimensional phase-contrast CMR (4D Flow CMR). Aortic growth rate was calculated as the change in maximal aortic diameter between baseline and follow-up imaging studies over the time interval, with patients categorized as having either 'stable' (< 3 mm/year) or 'enlarging' (≥ 3 mm/year) growth. Three metrics relating to FL pressurization were defined as: (1) FLEF: the ratio between retrograde and antegrade flow at the TBAD entry tear, (2) MSDR: the absolute difference between maximum and minimum systolic acceleration in the proximal FL, and (3) FL ΔPmax: the difference in absolute pressure between aortic root and distal FL. RESULTS: FLEF was higher in enlarging TBAD (49.0 ± 17.9% vs. 10.0 ± 11.9%, p = 0.002), whereas FL ΔPmax was lower (32.2 ± 10.8 vs. 57.2 ± 12.5 mmHg/m, p = 0.017). MSDR and conventional anatomic variables did not differ significantly between groups. FLEF showed positive (r = 0.78, p = 0.003) correlation with aortic growth rate whereas FL ΔPmax showed negative correlation (r = - 0.64, p = 0.026). FLEF and FL ΔPmax remained as independent predictors of aortic growth rate after adjusting for baseline aortic diameter. CONCLUSION: Comparative analysis of three 4D flow CMR metrics of TBAD FL pressurization demonstrated that those that focusing on retrograde flow (FLEF) and relative pressure (FL ΔPmax) independently correlated with growth and differentiated patients with enlarging and stable descending aortic dissections. These results emphasize the highly variable nature of aortic hemodynamics in TBAD patients, and suggest that 4D Flow CMR derived metrics of FL pressurization may be useful to separate patients at highest and lowest risk for progressive aortic growth and complications.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Disección Aórtica/diagnóstico por imagen , Aorta , Hemodinámica , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Resultado del Tratamiento
2.
J Magn Reson Imaging ; 44(3): 683-97, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26969867

RESUMEN

PURPOSE: To design and characterize a magnetic resonance imaging (MRI)-compatible aortic phantom simulating normal and aortic coarctation (AoCo) conditions and to compare its hemodynamics with healthy volunteers and AoCo patients. MATERIALS AND METHODS: The phantom is composed of an MRI-compatible pump, control unit, aortic model, compliance chamber, nonreturn, and shutoff valves. The phantom without and with AoCo (13, 11, and 9 mm) was studied using 2D and 3D phase-contrast data and with a catheterization unit to measure pressures. The phantom data were compared with the mean values of 10 healthy volunteers and two AoCo patients. RESULTS: Hemodynamic parameters in the normal phantom and healthy volunteers were: heart rate: 68/61 bpm, cardiac output: 3.5/4.5 L/min, peak flow and peak velocity (Vpeak) in the ascending aorta (AAo): 270/357 mL/s (significantly, P < 0.05) and 97/107 cm/s (not significantly, P = 0.16), and pressure in the AAo of the normal phantom of 131/58 mmHg. Hemodynamic parameters in the 13, 11, and 9 mm coarctation phantoms and Patients 1 and 2 were: heart rate: 75/75/75/97/78 bpm, cardiac output: 3.3/3.0/2.9/4.0/5.8 L/min, peak flow in the AAo: 245/265/215/244/376 mL/s, Vpeak in the AAo: 96/95/81/196/187 cm/s, Vpeak after the AoCo: 123/187/282/247/165 cm/s, pressure in the AAo: 124/56, 127/51, 133/50, 120/51 and 87/39 mmHg, and a trans-coarctation systolic pressure gradient: 7, 10, 30, 20, and 11 mmHg. CONCLUSION: We propose and characterize a normal and an AoCo phantom, whose hemodynamics, including velocity, flow, and pressure data are within the range of healthy volunteers and patients with AoCo. J. Magn. Reson. Imaging 2016;44:683-697.


Asunto(s)
Aorta/diagnóstico por imagen , Aorta/fisiopatología , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/fisiopatología , Técnicas de Imagen Cardíaca/instrumentación , Angiografía por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Velocidad del Flujo Sanguíneo , Cateterismo Cardíaco/métodos , Técnicas de Imagen Cardíaca/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Eur J Cardiothorac Surg ; 57(5): 896-903, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31821480

RESUMEN

OBJECTIVES: Current risk assessment strategies in type B aortic dissection are focused on anatomic parameters, although haemodynamic abnormalities that result in false lumen (FL) pressurization are thought to play a significant role in aortic growth. The objective of this study was to evaluate blood flow of the FL using 4D flow magnetic resonance imaging (MRI) and identify haemodynamic and anatomic factors that independently predict the rate of aortic growth. METHODS: Patients with dissection of the descending thoraco-abdominal aorta (n = 18) were enrolled in a prospective observational study and underwent 4D flow MRI for haemodynamic assessment of the entry tear and FL. Anatomic parameters were obtained by magnetic resonance angiography and baseline computed tomography. False lumen ejection fraction (FL EF) was defined the ratio of retrograde flow rate at the dominant entry tear during diastole over the antegrade systolic flow rate. RESULTS: The median aortic growth rate was 3.5 mm/year (interquartile range 0.5-8.1 mm/year). Entry tear peak velocity was lower in patients with enlarging aortic dimensions (95.5 ± 24.1 vs 128.1 ± 37.4 cm/s, P = 0.039). After adjusting for co-variates FL EF (ß = 0.15, P = 0.004), baseline maximal aortic diameter (ß = 0.37, P = 0.001) and the entry tear distance from the left subclavian artery (ß = 0.07, P = 0.016) were significant predictors of aortic growth rate. CONCLUSIONS: Beyond standard anatomic risk factors, FL EF is an independent predictor of aortic growth rate and may represent an intuitive, non-invasive method to estimate FL pressurization and improve patient-specific risk assessment in patients with type B aortic dissection.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aortografía , Hemodinámica , Humanos , Volumen Sistólico , Arteria Subclavia , Resultado del Tratamiento
4.
Magn Reson Imaging ; 33(8): 970-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26117696

RESUMEN

PURPOSE: To investigate the feasibility of estimating the portal vein blood volume that flows into the intrahepatic volume (IHPVBV) in each cardiac cycle using non-contrast MR venography technique as a surrogate marker of portal hypertension (PH). MATERIALS AND METHODS: Ten patients with chronic liver disease and clinical symptoms of PH (40% males, median age: 54.0, range: 44-73 years old) and ten healthy volunteers (80% males, median age: 54.0, range: 44-66 years old) were included in this study. A non-contrast Triple-Inversion-Recovery Arterial-Spin-Labeling (TIR-ASL) technique was used to quantify the IHPVBV in one and two cardiac cycles. Liver (LV) and spleen volumes (SV) were measured by manual segmentation from anatomical MR images as morphological markers of PH. All images were acquired in a 1.5T Philips Achieva MR scanner. RESULTS: PH patients had larger SV (P=0.02) and lower liver-to-spleen ratio (P=0.02) compared with healthy volunteers. The median IHPVBV in healthy volunteers was 13.5cm(3) and 26.5cm(3) for one and two cardiac cycles respectively, whereas in PH patients a median volume of 3.1cm(3) and 9.0cm(3) was observed. When correcting by LV, the IHPVBV was significantly higher in healthy volunteers than PH patients for one and two cardiac cycles. The combination of morphological information (liver-to-spleen ratio) and functional information (IHPVBV/LV) can accurately identify the PH patients with a sensitivity of 90% and specificity of 100%. CONCLUSION: Results show that the portal vein blood volume that flows into the intrahepatic volume in one and two cardiac cycles is significantly lower in PH patients than in healthy volunteers and can be quantified with non-contrast MRI techniques.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Volumen Sanguíneo , Hipertensión Portal/diagnóstico , Hipertensión Portal/fisiopatología , Angiografía por Resonancia Magnética/métodos , Vena Porta/fisiopatología , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Vena Porta/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA