1.
J Cardiovasc Electrophysiol ; 34(4): 860-868, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36738148

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is a common therapeutic strategy for patients with either paroxysmal AF (PAF) or persistent AF (persAF), but long-term ablation success rates are imperfect. Maintenance of sinus rhythm immediately before ablation with antiarrhythmic drug (AAD) therapy has been associated with improved outcomes in patients undergoing ablation. Amiodarone has superior efficacy relative to other AADs. Whether failure of amiodarone to maintain sinus rhythm before ablation for either PAF or persAF is associated with poor outcomes is unknown. METHODS: A total of 307 patients who received amiodarone in a 1-year window before undergoing catheter ablation for AF were included. Patients were divided into amiodarone success (n = 183) and amiodarone failure (n = 124) groups based on the response to pre-ablation amiodarone treatment. Analysis of procedural outcomes as a function of response to amiodarone therapy was performed. Patients were followed for at least 12 months postablation, to assess outcomes (adverse events and arrhythmia recurrence). Procedural success was defined by the absence of documented arrhythmia (>30 s) without any antiarrhythmic agents beyond a 90-day blanking period. RESULTS: Following ablation for either PAF or persAF, freedom from any recurrent atrial arrhythmia at 1 year was 57.7% for the entire cohort. One-year freedom from recurrent arrhythmia in the amiodarone success group was comparable to that in the amiodarone failure group (55.7% vs. 60.5%; p = .54). Success rates following ablation did not vary by the response to amiodarone when analyzed for PAF or persAF subgroups. CONCLUSION: Failure to restore and maintain sinus rhythm with amiodarone before ablation for either PAF or persAF is not a predictor of ablation procedural failure. Amiodarone failure alone should not deter practitioners from considering ablation therapy for patients with AF.


Asunto(s)
Técnicas de Ablación , Amiodarona , Fibrilación Atrial , Ablación por Catéter , Humanos , Amiodarona/uso terapéutico , Fibrilación Atrial/cirugía , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos
2.
J Cardiovasc Electrophysiol ; 34(8): 1640-1647, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37365926

RESUMEN

BACKGROUND: Studies have identified significant sex-based differences and disparities in the clinical presentation and treatment of atrial fibrillation (AF). Studies have shown women are less likely to be referred for catheter ablation, are older at the time of ablation, and are more likely to have recurrence after ablation. However, in most studies investigating AF ablation outcomes, the female cohorts were relatively small. The impact of sex on the outcome and safety of ablation procedures is still unclear. OBJECTIVE: To investigate sex-based differences in outcomes and complications after AF catheter ablation, with a significant female cohort METHOD: In this retrospective study, patients undergoing AF ablation from January 1, 2014, to March 31, 2021, were included. We investigated clinical characteristics, duration and progression of AF, number of EP appointments from diagnosis to ablation, procedural data, and procedure complications. RESULTS: Total of 1346 patients underwent first catheter ablation for AF during this period, including 896 (66.5%) male and 450 (33.4%) female patients. Female patients were older at the time of ablation (66.2 vs. 62.4 years; p < .001). Women had higher CHA2 DS2 -VASc (congestive heart failure, hypertension, age, diabetes, stroke, vascular disease, sex category) scores (3 vs. 2; p < .001) than men, expectedly, as the female sex warrants an additional point. 25.3% female patients had PersAF at the time of diagnosis versus 35.3% male patients (p < .001). At the time of ablation, 31.8% female patients had PersAF as compared to 43.1% male patients (p < .001), indicating progression of PAF to PersAF in both sexes. Women tried more AADs than men before ablation (1.13 vs. 0.98; p = .002). Male and female patients had no statistically significant difference in (a) arrhythmia recurrence at 1-year post ablation (27.7% vs. 30%; p = .38) or (b) procedural complication rate (1.8% vs. 3.1%; p = .56). CONCLUSION: Female patients were older and had higher CHA2 DS2 -VASc scores compared to males at the time of AF ablation. Women tried more AADs than men before ablation. One-year arrhythmia recurrence rates and procedural complications were similar in both sexes. No sex-based differences were observed in safety and efficacy of ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Tiempo , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
3.
Indian Pacing Electrophysiol J ; 22(1): 24-29, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34838748

RESUMEN

BACKGROUND: There are limited data describing the experience of radiofrequency (RF) vs. cryoballoon (CB) ablation for atrial fibrillation (AF) among elderly patients in the United States. METHODS: We conducted a retrospective analysis of patients ≥75 years of age undergoing index RF vs. CB ablation between January 2014 and May 2020 at our center. The choice of ablation technique was left to the operator's discretion. Major complications and efficacy, defined as freedom from any atrial tachyarrhythmia (ATA) lasting ≥30 s after one year of follow-up, were assessed in patients with index RF vs. CB ablation. RESULTS: In our cohort of 186 patients, the median age was 78 (76-81) years, 54.8% were men, and 39.2% had persistent AF. The median CHA2DS2-VASc score was 4 (3-4), while the median duration of AF was 3 (1-7) years. The majority (n = 112, 60.2%) underwent RF ablation. The median procedure time was significantly lower in CB group (197 vs 226.5 min, p=<0.01). The incidence of complications was similar in the two sub-groups (RF: 1.8% vs. CB: 2.7%, p = 0.67). Similarly, arrhythmia-free survival rate on antiarrhythmic drugs at 1-year follow-up remained statistically comparable (63.4% vs. 68.9%, p = 0.33) between patients receiving RF vs. CB ablation. CONCLUSION: The safety and efficacy of RF vs. CB ablation for AF remained comparable in our cohort of patients older than 75 years. CB ablation was associated with a shorter procedure time.

4.
J Cardiovasc Electrophysiol ; 32(12): 3125-3134, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34453377

RESUMEN

BACKGROUND: Transesophageal echocardiography (TEE) is variably performed before atrial fibrillation (AF) ablation to evaluate left atrial appendage (LAA) thrombus. We describe our experience with transitioning to the pre-ablation cardiac computed tomography (CT) approach for the assessment of LAA thrombus during the COVID-19 pandemic. METHODS: We studied consecutive patients undergoing AF ablation at our center. The study cohort was divided into pre- versus post-COVID groups. The pre-COVID cohort included ablations performed during the 1 year before the COVID-19 pandemic; pre-ablation TEE was used routinely to evaluate LAA thrombus in high-risk patients. Post-COVID cohort included ablations performed during the 1 year after the COVID-19 pandemic; pre-ablation CT was performed in all patients, with TEE performed only in patients with LAA thrombus by CT imaging. The demographics, clinical history, imaging, and ablation characteristics, and peri-procedural cerebrovascular events (CVEs) were recorded. RESULTS: A total of 637 patients (pre-COVID n = 424, post-COVID n = 213) were studied. The mean age was 65.6 ± 10.1 years in the total cohort, and the majority were men. There was a significant increase in pre-ablation CT imaging from pre- to post-COVID cohort (74.8% vs. 93.9%, p ≤ .01), with a significant reduction in TEEs (34.6% vs. 3.7%, p ≤ .01). One patient in the post-COVID cohort developed CVE following negative pre-ablation CT. However, the incidence of peri-procedural CVE between both cohorts remained statistically unchanged (0% vs. 0.4%, p = .33). CONCLUSION: Implementation of pre-ablation CT-only imaging strategy with selective use of TEE for LAA thrombus evaluation is not associated with increased CVE risk during the COVID-19 pandemic.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , COVID-19 , Ablación por Catéter , Trombosis , Anciano , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ecocardiografía Transesofágica , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pandemias , SARS-CoV-2 , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Tomografía
5.
J Cardiovasc Electrophysiol ; 32(6): 1631-1639, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33928697

RESUMEN

BACKGROUND: Data related to electrophysiologic characteristics of atypical atrial flutter (AFL) following atrial fibrillation (AF) ablation and its prognostic value on repeat ablation success are limited. METHODS: We studied consecutive patients who underwent a repeat left atrial (LA) ablation procedure for either recurrent AF or atypical AFL, at least 3 months after index AF ablation, between January 2012 and July 2019. The demographics, clinical history, procedural data, complications, and 1-year arrhythmia-free survival rates were recorded for each subject after the first repeat ablation. RESULTS: A total of 336 patients were included in our study. Among these 336 patients, 102 underwent a repeat ablation procedure for atypical AFL and 234 underwent a repeat ablation procedure for recurrent AF. The mean age was 63.7 ± 10.7 years, and 72.6% of patients were men. The atypical AFL cohort had significantly higher LA diameters (4.6 vs. 4.4 cm, p = .04) and LA volume indices (LAVi; 85.1 vs. 75.4 ml/m2 , p = .03) compared to AF patients at repeat ablation. Atypical AFL patients were more likely to have had index radiofrequency (RF) ablation (as opposed to cryoballoon) than recurrent AF patients (98% vs. 81%, p = .01). Atypical AFLs were roof-dependent in 35.6% and peri-mitral in 23.8% of cases. Major complications at repeat ablation occurred in 0.9% of the total cohort. Arrhythmia-free survival at one year was significantly higher in the recurrent atypical AFL compared to the recurrent AF cohort (75.5 vs. 65.0%, p = .04). CONCLUSION: In our series, roof-dependent flutter is the most common form of atypical atrial flutter post AF ablation. Patients developing atypical AFL after index AF ablation have greater LA dimensions than patients with recurrent AF. The success rate of first repeat ablation is significantly higher among patients with recurrent atypical AFL as compared to recurrent AF after index AF ablation.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 32(2): 316-324, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33350536

RESUMEN

BACKGROUND: The effects of atrial fibrillation (AF) catheter ablation on the left atrium (LA) are poorly understood. OBJECTIVES: To examine short- and long-term associations of AF catheter ablation with LA function using cardiac magnetic resonance (CMR). METHODS: Fifty-one AF patients (mean age 56 ± 8 years) underwent CMR at baseline, 1 day (n = 17) and 11 ± 2 months after ablation (n = 38). LA phasic volumes, emptying fractions (LAEF), and longitudinal strain were measured using feature-tracking CMR. LA fibrosis was quantified using late gadolinium enhancement (LGE). RESULTS: There were no acute changes in volume; however, active, total LAEF, and peak LA strain decreased significantly compared to the baseline. During long-term follow-up, there was a decrease in maximum but not minimum LA volume (from 99 ± 5.2 ml to 89 ± 4.7 ml; p = .009) and a decrease in total LAEF (from 43 ± 1.8% to 39 ± 2.0%; p = .001). In patients with AF recurrence, LA volumes were unchanged. However, total LAEF decreased from 38 ± 3% to 33 ± 3%; p = .015. Patients without AF recurrence had no changes in LA functional parameters during follow-up. The amount of LA LGE at long-term follow-up was higher compared to the baseline, however, was significantly less compared to immediately post-procedure (37 ± 1.9% vs. 47 ± 2.8%; p = .015). A higher increase in LA LGE extent compared to the baseline was associated with a greater decrease in total LAEF (r = -.59; p < .001). CONCLUSIONS: LA function is impaired acutely following AF catheter ablation. However, long-term changes of LA function are associated positively with the successful restoration of sinus rhythm and inversely with increased LA LGE.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Medios de Contraste , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Persona de Mediana Edad
7.
J Cardiovasc Electrophysiol ; 32(3): 628-638, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33410561

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) ablation is successful in 60%-80% of optimal candidates, with many patients requiring repeat procedures. We performed a detailed examination of electrophysiologic findings and clinical outcomes associated with first repeat AF ablations in the era of contact force-sensing radiofrequency (RF) catheters. METHODS: We retrospectively studied patients who underwent their first repeat AF ablations for symptomatic, recurrent AF at our center between 2013 and 2019. All repeat ablations were performed using contact force-sensing RF catheters. Pulmonary vein (PV) reconnections at repeat ablation and freedom from atrial arrhythmia 1 year after repeat ablation were evaluated. We further assessed these findings based on AF classification at the time of presentation for repeat ablation, index RF versus cryoballoon (CB) ablation, and duration (≥3 versus <3 years) between index and repeat procedures. RESULTS: Among 300 patients, there were 136 (45.3%) who presented for their first repeat ablations in persistent AF. During repeat ablation, at least one PV reconnection was found in 257 (85.6%) patients, while 159 (53%) had three to four reconnections. There was a similar distribution of reconnections among patients with persistent versus paroxysmal AF (mean: 2.7 ± 1.3 vs. 2.9 ± 1.2; p = .341), index RF versus CB ablation (mean: 2.8 ± 1.3 vs. 2.9 ± 1.2; p = .553), and ≥3 versus <3 years between index and repeat procedures (mean: 3.0 ± 1.1 vs. 2.7 ± 1.3; p = .119). At repeat ablation, the PVs were re-isolated in all patients, and additional non-PV ablation was performed in 171 (57%) patients. Freedom from atrial arrhythmia at 1-year follow-up after repeat ablation was 66%, similar among those with persistent versus paroxysmal AF (65.4% vs. 66.5%; p = .720), index RF versus CB ablation (66.7% vs. 68.9%; p = .930), and ≥3 versus <3 years between index and repeat ablations (64.4% vs. 66.7%; p = .760). Major complications occurred in a total of 4 (1.3%) patients. CONCLUSION: In a contemporary cohort of patients receiving their first repeat AF ablations using contact force-sensing RF catheters, PV reconnections were common, and freedom from atrial arrhythmia was 66% at 1-year follow-up. The distributions of PV reconnections and rates of freedom from atrial arrhythmia were similar, based on persistent versus paroxysmal AF at presentation for repeat ablation, index RF versus CB ablation, and duration between index and repeat procedures. The incidence of major complications was very low.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
8.
J Card Fail ; 27(8): 915-919, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34364670

RESUMEN

BACKGROUND: Whether rhythm control for post-operative atrial fibrillation after cardiac surgery (POAF) is superior to rate control in patients with heart failure or systolic dysfunction (HF) is not known. METHODS: We performed a post-hoc analysis of a trial by the Cardiothoracic Surgical Trials Network, which randomized patients with POAF after cardiac surgery to rate control or rhythm control with amiodarone/cardioversion. We assessed subgroups of trial participants defined by heart failure/cardiomyopathy history or left ventricular ejection fraction (LVEF) < 50%. We conducted a stratified analysis in patients with and without HF to explore outcomes of rhythm versus rate control strategy. RESULTS: Of 523 subjects with POAF after cardiac surgery, 131 (25%) had HF. 49% of HF patients were randomized to rhythm control. In HF patients, rhythm control was associated with less atrial fibrillation within the first 7 days. There were no differences in rhythm at 30- and 60-day follow-up. In the HF group, there were significantly more subjects with AF < 48 hours in the rhythm control group compared to rate control group- 68.8% compared to 46.3%, P=0.009. By comparison, in the non-HF stratum, 54.4% of the rate control group had AF < 48 hours compared to 63.5% of the rhythm control group (P=0.067).), though there was no significant interaction of heart failure with cardiac rhythm at 7 days (Pinteraction 0.16). CONCLUSION: Rhythm control for HF patients with POAF after cardiac surgery increases early restoration of sinus rhythm. Rate and rhythm control are both reasonable for HF patients with AF after cardiac surgery.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/etiología , Frecuencia Cardíaca , Humanos , Volumen Sistólico , Función Ventricular Izquierda
9.
J Cardiovasc Electrophysiol ; 31(7): 1719-1725, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32510679

RESUMEN

INTRODUCTION: Advanced interatrial block (IAB) on a 12-lead electrocardiogram (ECG) is a predictor of stroke, incident atrial fibrillation (AF), and AF recurrence after catheter ablation. The objective of this study was to determine which features of IAB structural remodeling is associated with left atrium (LA) magnetic resonance imaging structure and function. METHODS/RESULTS: We included 152 consecutive patients (23% nonparoxysmal AF) who underwent preprocedural ECG and cardiac magnetic resonance (CMR) in sinus rhythm before catheter ablation of AF. IAB was defined as P-wave duration ≥120 ms, and was considered partial if P-wave was positive and advanced if P-wave had a biphasic morphology in inferior leads. From cine CMR and late gadolinium enhancement, we derived LA maximum and minimum volume indices, strain, LA fibrosis, and LA dyssynchrony. A total of 77 patients (50.7% paroxysmal) had normal P-wave, 52 (34.2%) partial IAB, and 23 (15.1%) advanced IAB. Patients with advanced IAB had significantly higher LA minimum volume index (25.7 vs 19.9 mL/m2 , P = .010), more LA fibrosis (21.9% vs 13.1%, P = .020), and lower LA maximum strain rate (0.99 vs 1.18, P = .007) than those without. Advanced IAB was independently associated with LA (minimum [P = .032] and fibrosis [P = .009]). P-wave duration was also independently associated with LA fibrosis (ß = .33; P = .049) and LA mechanical dyssynchrony (ß = 2.01; P = .007). CONCLUSION: Advanced IAB is associated with larger LA volumes, lower emptying fraction, and more fibrosis. Longer P-wave duration is also associated with more LA fibrosis and higher LA mechanical dyssynchrony.


Asunto(s)
Fibrilación Atrial , Bloqueo Interauricular , Anciano , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Fibrilación Atrial/diagnóstico por imagen , Medios de Contraste , Electrocardiografía , Femenino , Fibrosis , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Humanos , Bloqueo Interauricular/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
10.
Pacing Clin Electrophysiol ; 43(1): 2-9, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31691986

RESUMEN

BACKGROUND: Pacemaker battery depletion triggers alert for replacement notification and results in automatic reprogramming, which has been shown to be associated with relevant cardiorespiratory symptoms and adverse clinical events. OBJECTIVE: Determine if electrocardiogram (ECG) pacing features may be predictive of pacemaker battery depletion and clinical risk. METHODS: This is an ECG substudy of a cohort analysis of 298 subjects referred for pacemaker generator replacement from 2006 to 2017. Electronic medical record review was performed; clinical, ECG, and pacemaker characteristics were abstracted. We applied two ECG prediction rules for pacemaker battery depletion that are relevant to all major pacemaker manufacturers except Boston Scientific and MicroPort: (1) atrial pacing not at a multiple of 10 and (2) nonsynchronous ventricular pacing not at a multiple of 10, to determine diagnostic sensitivity, specificity, and risk in applicable ECG subjects. RESULTS: We excluded 32 subjects not at replacement notification or duplicate surgeries. Overall, 176 of 266 subjects (66.2%) demonstrated atrial pacing or nonsynchronous ventricular pacing on preoperative ECG. When utilizing both rules, 139 of 176 preoperative ECGs and 12 of 163 postoperative ECGs met criteria for battery depletion yielding reasonable sensitivity (79.0%), high specificity (92.6%), and a positive likelihood ratio of 11.6:1. These rules were associated with significant increase in cardiorespiratory symptoms (P < .001) and adverse clinical events (P < .025). CONCLUSIONS: The "Rules of Ten" provided reasonable sensitivity and specificity for detecting replacement notification in pacemaker subjects with an applicable ECG. This ECG tool may help clinicians identify most patients with pacemaker battery depletion at significant clinical risk.


Asunto(s)
Suministros de Energía Eléctrica , Electrocardiografía/métodos , Falla de Equipo , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad
11.
J Cardiovasc Electrophysiol ; 30(12): 2818-2822, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31670430

RESUMEN

INTRODUCTION: Ablation of atrial vagal ganglia has been associated with improved pulmonary vein isolation (PVI) outcomes. Disruption of vagal reflexes results in heart rate (HR) increase. We investigated the association between HR change after PVI and freedom from atrial fibrillation (AF) at 1 year. METHODS AND RESULTS: Patients who underwent PVI for paroxysmal AF were identified from the Johns Hopkins Hospital AF registry. Electrocardiograms taken pre-PVI and post-PVI were used to determine the change in HR. Patients followed-up at 3, 6, and 12 months. Of 257 patients (66% male, age 59+/-11 years), 134 (52%) remained free from AF at 1 year. The average HR increased from 60.6 ± 11.3 beats per minute (bpm) pre-PVI to 70.7 ± 12.0 bpm post-PVI. Patients with recurrence of AF had lower post-PVI HR than those who remained free from AF (67.8 ± 0.2 vs 73.3 ± 13.0 bpm; P <.001). The probability of AF recurrence at 1-year decreased as the change in HR increased (estimated odds ratio [OR], 0.83; 95% confidence interval [CI, 0.74-0.93]; P = .002). HR increase more than 15 bpm was associated with the lowest odds of AF recurrence (estimated OR, 0.39; 95% [0.17-0.85]; P = .018) compared to HR decrease. CONCLUSIONS: Resting HR was found to increase after PVI. Increase in HR more than 15 bpm has a positive association with remaining free from atrial fibrillation at 1 year.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Ganglios Parasimpáticos/cirugía , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Nervio Vago/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Supervivencia sin Enfermedad , Femenino , Ganglios Parasimpáticos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/inervación , Recurrencia , Reflejo , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Nervio Vago/fisiopatología
12.
J Cardiovasc Electrophysiol ; 29(2): 239-245, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29131442

RESUMEN

INTRODUCTION: Catheter ablation is common for patients with symptomatic, drug-refractory atrial fibrillation (AF). Obesity is a known risk factor for incident AF. The impact of obesity on AF ablation outcomes is incompletely understood. We sought to determine the impact of elevated body mass index (BMI) on pulmonary vein isolation (PVI) procedural outcomes and associated complications. METHODS AND RESULTS: We evaluated patients undergoing PVI from 2001 to 2015, dividing them into four groups: normal weight (BMI ≥ 18.5 to < 25), overweight (BMI ≥ 25 to < 30), obese (BMI > 30 to < 40), and morbidly obese (BMI ≥ 40). Demographic and procedural characteristics, complications, and ablation outcomes were compared among groups. A total of 701 patients (146 time-matched controls, 227 overweight, 244 obese, and 84 morbidly obese) with complete demographic, procedural, and follow-up data were included. Increasing BMI correlated positively with HTN, OSA, CHA2 DS2 -VASC score, and persistent AF (P ≤ 0.001 for all associations). Radiofrequency application time and intraprocedural heparin dose increased with BMI (P ≤ 0.001). Arrhythmia recurrence at 1 year was 39.9% in controls, while higher in all high-BMI groups (overweight, 51.3%; obese, 57%; morbidly obese, 58.1 %; P  =  0.007 for all versus controls). Impact of BMI on AF recurrence was not seen in persistent AF patients. Complication rates across groups were similar. CONCLUSIONS: AF recurrence after catheter ablation is higher in overweight, obese, and morbidly obese patients comparing to normal-weight controls, driven primarily by outcomes differences in paroxysmal AF patients. Complications were not associated with increased BMI.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Obesidad/complicaciones , Sobrepeso/complicaciones , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Índice de Masa Corporal , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Obesidad/diagnóstico , Sobrepeso/diagnóstico , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Europace ; 20(4): e51-e59, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28541507

RESUMEN

Aims: Historical studies of ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) have shown high long-term success rates and low complication rates. The potential impact of several recent practice trends has not been described. This study aims to characterize recent clinical practice trends in AVNRT ablation and their associated success rates and complications. Methods and results: Patients undergoing initial ablation of AVNRT between 1 July 2005 and 30 June 2015 were included in this study. Patient demographics and procedural data were abstracted from procedure reports. Follow-up data, including AVNRT recurrence and complications, was evaluated through electronic medical record review. In total, 877 patients underwent catheter ablation for AVNRT. By the last recorded year, three-dimension (3D) electroanatomical mapping (EAM) was used in 36.2%, 43.2% included anaesthesia, and 23.1% utilized irrigated catheters. Long-term procedural success was 95.5%. The use of anaesthesia, 3D EAM, and irrigated ablation catheters were not associated with differences in success. The presence of an atrial 'echo' or 'AH' jump at the end of an acutely successful procedure was not associated with long-term recurrence (P = 0.18, P = 0.15, respectively). Complications, including AV block requiring a pacemaker (0.4%), were uncommon. Conclusion: In a large, contemporary cohort, catheter ablation for AVNRT remains highly successful with low complications rates. The increased use of anaesthesia as well as modern mapping and ablation tools were not associated with changes in clinical outcomes. Further prospective evaluation of such contemporary practices is warranted given the lack of evidence to support their escalating use.


Asunto(s)
Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Anestesia/métodos , Ablación por Catéter/efectos adversos , Ablación por Catéter/tendencias , Técnicas Electrofisiológicas Cardíacas , Humanos , Complicaciones Posoperatorias/etiología , Pautas de la Práctica en Medicina/tendencias , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Flujo de Trabajo
14.
Europace ; 20(12): 1989-1996, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29688340

RESUMEN

Aims: The optimal site for biventricular endocardial (BIVENDO) pacing remains undefined. Acute haemodynamic response (AHR) is reproducible marker of left ventricular (LV) contractility, best expressed as the change in the maximum rate of LV pressure (LV-dp/dtmax), from a baseline state. We examined the relationship between factors known to impact LV contractility, whilst delivering BIVENDO pacing at a variety of LV endocardial (LVENDO) locations. Methods and results: We compiled a registry of acute LVENDO pacing studies from five international centres: Johns Hopkins-USA, Bordeaux-France, Eindhoven-The Netherlands, Oxford-United Kingdom, and Guys and St Thomas' NHS Foundation Trust, London-UK. In all, 104 patients incorporating 687 endocardial and 93 epicardial pacing locations were studied. Mean age was 66 ± 11 years, mean left ventricular ejection fraction 24.6 ± 7.7% and mean QRS duration of 163 ± 30 ms. In all, 50% were ischaemic [ischaemic cardiomyopathy (ICM)]. Scarred segments were associated with worse haemodynamics (dp/dtmax; 890 mmHg/s vs. 982 mmHg/s, P < 0.01). Delivering BiVENDO pacing in areas of electrical latency was associated with greater improvements in AHR (P < 0.01). Stimulating late activating tissue (LVLED >50%) achieved greater increases in AHR than non-late activating tissue (LVLED < 50%) (8.6 ± 9.6% vs. 16.1 ± 16.2%, P = 0.002). However, the LVENDO pacing location with the latest Q-LV, was associated with the optimal AHR in just 62% of cases. Conclusions: Identifying viable LVENDO tissue which displays late electrical activation is crucial to identifying the optimal BiVENDO pacing site. Stimulating late activating tissue (LVLED >50%) yields greater improvements in AHR however, the optimal location is frequently not the site of latest activation.


Asunto(s)
Potenciales de Acción , Terapia de Resincronización Cardíaca/métodos , Endocardio/fisiopatología , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Contracción Miocárdica , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Anciano , Europa (Continente) , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Tiempo de Reacción , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Presión Ventricular
15.
Pacing Clin Electrophysiol ; 41(12): 1611-1618, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30375674

RESUMEN

BACKGROUND: Pacemaker patients experience battery depletion that activates pacemaker's alert for replacement notification. Automatic reprogramming at replacement notification can result in loss of rate response and atrioventricular (AV) synchrony. OBJECTIVE: To determine if relevant symptoms or clinical events may be associated with automatic reprogramming at replacement notification. METHODS: Electronic medical record review was undertaken for 298 patients referred for pacemaker generator replacement. Primary endpoints were symptoms or clinical events during replacement notification period. RESULTS: Following elimination of duplicate pacemaker replacements (n = 12), "near-replacement notification" or "recalled" (n = 15) and pacemakers at "end of life" (n = 5), 266 subjects were included. Three distinct reprogramming cohorts were identified; those with no change (control) in pacing mode (n = 46), those with loss of rate response (n = 154), and those with loss of AV synchrony ± rate response (n = 66). In total, 83 subjects (31.2%) had symptoms with significant differences seen between groups (control = 4.3%, loss of rate response = 26.0%, loss of AV synchrony ± rate response = 62.1%, P < 0.001). Overall, 28 subjects (10.5%) experienced clinical events with significant differences seen between groups (control = 0.0%, loss of rate response = 6.5%, loss of AV synchrony ± rate response = 27.3%, P < 0.001). CONCLUSIONS: Automatic reprogramming at replacement notification was associated with significant symptoms in 26% of those who lost rate response and in 62% of those who lost AV synchrony ± rate response. Additionally, 27% of the latter cohort required nonelective clinical care.


Asunto(s)
Suministros de Energía Eléctrica , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Remoción de Dispositivos , Electrodos Implantados , Falla de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo
16.
Pacing Clin Electrophysiol ; 41(11): 1500-1507, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30191580

RESUMEN

BACKGROUND: Patients go without pacemaker, defibrillator, and cardiac resynchronization therapies (devices) each year due to the prohibitive costs of devices. OBJECTIVE: We sought to examine data available from studies regarding contemporary risks of reused devices in comparison with new devices. METHODS: We searched online indexing sites to identify recent studies. Peer-reviewed manuscripts reporting infection, malfunction, premature battery depletion, and device-related death with reused devices were included. The primary study outcome was the composite risk of infection, malfunction, premature battery depletion, and death. Secondary outcomes were the individual risks. RESULTS: Nine observational studies (published 2009-2017) were identified totaling 2,302 devices (2,017 pacemakers, 285 defibrillators). Five controlled trials were included in meta-analysis (2,114 devices; 1,258 new vs 856 reused). All device reuse protocols employed interrogation to confirm longevity and functionality, disinfectant therapy, and, usually, additional biocidal agents, packaging, and ethylene oxide gas sterilization. Demographic characteristics, indications for pacing, and median follow-up were similar. There were no device-related deaths reported and no statistically significant difference in risk between new versus reused devices for the primary outcome (2.23% vs 3.86% respectively, P = 0.807, odds ratio = 0.76). There were no significant differences seen in the secondary outcomes for the individual risks of infection, malfunction, and premature battery depletion. CONCLUSIONS: Device reuse utilizing modern protocols did not significantly increase risk of infection, malfunction, premature battery depletion, or device-related death in observational studies. These data provide rationale for proceeding with a prospective multicenter noninferiority randomized control trial.


Asunto(s)
Desfibriladores Implantables , Equipo Reutilizado , Marcapaso Artificial , Remoción de Dispositivos , Falla de Equipo , Humanos , Factores de Riesgo
17.
Chaos ; 28(6): 063130, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29960392

RESUMEN

The mechanism of atrial fibrillation (AF) maintenance in humans is yet to be determined. It remains controversial whether cardiac fibrillatory dynamics are the result of a deterministic or a stochastic process. Traditional methods to differentiate deterministic from stochastic processes have several limitations and are not reliably applied to short and noisy data obtained during clinical studies. The appearance of missing ordinal patterns (MOPs) using the Bandt-Pompe (BP) symbolization is indicative of deterministic dynamics and is robust to brief time series and experimental noise. Our aim was to evaluate whether human AF dynamics is the result of a stochastic or a deterministic process. We used 38 intracardiac atrial electrograms during AF from the coronary sinus of 10 patients undergoing catheter ablation of AF. We extracted the intervals between consecutive atrial depolarizations (AA interval) and converted the AA interval time series to their BP symbolic representation (embedding dimension 5, time delay 1). We generated 40 iterative amplitude-adjusted, Fourier-transform (IAAFT) surrogate data for each of the AA time series. IAAFT surrogates have the same frequency spectrum, autocorrelation, and probability distribution with the original time series. Using the BP symbolization, we compared the number of MOPs and the rate of MOP decay in the first 1000 timepoints of the original time series with that of the surrogate data. We calculated permutation entropy and permutation statistical complexity and represented each time series on the causal entropy-complexity plane. We demonstrated that (a) the number of MOPs in human AF is significantly higher compared to the surrogate data (2.7 ± 1.18 vs. 0.39 ± 0.28, p < 0.001); (b) the median rate of MOP decay in human AF was significantly lower compared with the surrogate data (6.58 × 10-3 vs. 7.79 × 10-3, p < 0.001); and (c) 81.6% of the individual recordings had a rate of decay lower than the 95% confidence intervals of their corresponding surrogates. On the causal entropy-complexity plane, human AF lay on the deterministic part of the plane that was located above the trajectory of fractional Brownian motion with different Hurst exponents on the plane. This analysis demonstrates that human AF dynamics does not arise from a rescaled linear stochastic process or a fractional noise, but either a deterministic or a nonlinear stochastic process. Our results justify the development and application of mathematical analysis and modeling tools to enable predictive control of human AF.


Asunto(s)
Algoritmos , Fibrilación Atrial/fisiopatología , Entropía , Electrocardiografía , Humanos , Procesamiento de Señales Asistido por Computador , Procesos Estocásticos
20.
Europace ; 19(2): 241-249, 2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28172794

RESUMEN

Aims: Complications from catheter ablation for atrial fibrillation (AF) are well described. Changing aspects of AF ablation including patient populations referred, institutional experience, and emerging catheter and pharmacological options may impact complication rates. We assessed procedural complication trends in AF ablation patients from 2003­2015 to identify what factors affect adverse event rates. Methods and Results: We evaluated consecutively enrolled patients undergoing initial AF ablation from 2003 through 2015. Statistical analyses were performed to identify predictors of increased risk for major complications, which were defined as death, stroke, atrio-oesophageal fistula, phrenic nerve injury, cardiovascular events requiring blood transfusions or procedural interventions, or non-cardiovascular events requiring intervention. A total of 1475 patients (mean age 59.5 ± 10.5, 82% male) were evaluated. Major complications occurred in 3.9% (n = 58) of cases, including vascular access-site haematoma (1.3%), cardiac tamponade (1.1%), and cerebrovascular accident (CVA) (0.9%). Univariate analysis revealed increased risk of complications associated with hypertension (P = 0.048), CHA2DS2VASc score ≥1 (P = 0.015), and early institutional experience (P = 0.003). Populations with higher CHA2DS2VASc scores underwent AF ablation more frequently over time (P < 0.001). Novel catheters and anticoagulants did not appreciably affect complication rates. Multivariate analysis adjusting for hypertension, CHA2DS2VASc score, and institutional experience showed that higher CHA2DS2VASc score and early institutional experience were independent predictors of adverse events. Conclusion: Patient characteristics reflected in CHA2DS2VASc scoring and early institutional experience predict increased complication rates following AF ablation. Despite more patients with higher CHA2DS2VASc scores undergoing AF ablation, complication rates fell over time as institutional experience increased.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Fístula Esofágica/epidemiología , Complicaciones Posoperatorias/epidemiología , Anciano , Transfusión Sanguínea/estadística & datos numéricos , Taponamiento Cardíaco/epidemiología , Enfermedades Cardiovasculares/epidemiología , Femenino , Atrios Cardíacos , Cardiopatías/epidemiología , Hematoma/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Análisis Multivariante , Nervio Frénico/lesiones , Complicaciones Posoperatorias/terapia , Factores de Riesgo , Accidente Cerebrovascular/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA