Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Opt Lett ; 48(22): 6056-6059, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37966788

RESUMEN

Dynamic multiple light scattering (DMLS) has found numerous applications, including soft matter physics and biomedical optics. Yet biological tissues may have complex internal geometries, presenting a challenge for noninvasive measurements. Deciphering laminar dynamics is crucial to accurately interpret tissue or organ physiology. Seminal DMLS work noted that one can probe deeper layers indirectly by analyzing light fluctuations on shorter time scales. Recent technologies have enabled probing deeper layers directly by analyzing fluctuations at longer path lengths. The following question arises: are the indirect and direct approaches synergistic or redundant? Here, by adding an optical switch to path-length-filtered interferometric diffusing wave spectroscopy, we experimentally address this question in the context of a forearm occlusion study. We find that both approaches afford better distinction of light scattering dynamics in layered tissues than either approach alone. This motivates further development of methods that integrate both decorrelation time scale and light path length to probe layered tissues.


Asunto(s)
Interferometría , Óptica y Fotónica , Análisis Espectral , Difusión
2.
Opt Lett ; 48(18): 4737-4740, 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37707890

RESUMEN

We demonstrate superluminescent diodes (SLDs) for visible light optical coherence tomography (OCT) of the human retina. SLDs are less costly than supercontinuum sources and have lower intrinsic excess noise, enabling imaging closer to the shot noise limit. While single SLDs are not broadband, they provide power concentrated at specific wavelengths relevant to retinal function. As a new, to the best of our knowledge, application, we image human macular pigments (MPs), which are thought to both aid vision and protect against advanced age-related macular degeneration. Using the unique depth-resolved capabilities of OCT, we localize MPs in depth to Henle's fibers beneath the foveal pit in the living human retina. Our approach reduces the cost of visible light OCT to nearly that of near-infrared (NIR) OCT while also providing information about clinically relevant MPs which cannot be measured in the NIR.


Asunto(s)
Pigmento Macular , Tomografía de Coherencia Óptica , Humanos , Luz , Retina/diagnóstico por imagen
3.
Opt Lett ; 47(1): 110-113, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34951892

RESUMEN

In diffuse optics, quantitative assessment of the human brain is confounded by the skull and scalp. To better understand these superficial tissues, we advance interferometric near-infrared spectroscopy (iNIRS) to form images of the human superficial forehead blood flow index (BFI). We present a null source-collector (S-C) polarization splitting approach that enables galvanometer scanning and eliminates unwanted backscattered light. Images show an order-of-magnitude heterogeneity in superficial dynamics, implying an order-of-magnitude heterogeneity in brain specificity, depending on forehead location. Along the time-of-flight dimension, autocorrelation decay rates support a three-layer model with increasing BFI from the skull to the scalp to the brain. By accurately characterizing superficial tissues, this approach can help improve specificity for the human brain.


Asunto(s)
Interferometría , Espectroscopía Infrarroja Corta , Encéfalo/diagnóstico por imagen , Hemodinámica , Humanos , Cráneo
4.
Opt Lett ; 46(18): 4498-4501, 2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34525031

RESUMEN

We present multi-exposure interferometric diffusing wave spectroscopy (MiDWS), which measures brain blood flow index (BFI) continuously and non-invasively. MiDWS employs interferometry to detect low light levels, probing the optical field autocorrelation indirectly by varying the sensor exposure time. Here MiDWS is compared with conventional interferometric diffusing wave spectroscopy and speckle contrast optical spectroscopy in phantoms. Notably, the MiDWS approach enables the use of low frame rate, two-dimensional complementary metal-oxide semiconductor cameras in a short exposure time regime, where detector noise greatly exceeds the sample photon count. Finally, we show that MiDWS can monitor the BFI simultaneously at two source-collector separations (1 and 3 cm) on the adult human head on a single camera, enabling the use of superficial signal regression techniques to improve brain specificity.


Asunto(s)
Interferometría , Fotones , Circulación Cerebrovascular , Humanos , Fantasmas de Imagen , Análisis Espectral
5.
Opt Express ; 28(8): 11191-11214, 2020 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-32403635

RESUMEN

Diffusing wave spectroscopy (DWS) and diffuse correlation spectroscopy (DCS) can assess blood flow index (BFI) of biological tissue with multiply scattered light. Though the main biological function of red blood cells (RBCs) is advection, in DWS/DCS, RBCs are assumed to undergo Brownian motion. To explain this discrepancy, we critically examine the cumulant approximation, a major assumption in DWS/DCS. We present a precise criterion for validity of the cumulant approximation, and in realistic tissue models, identify conditions that invalidate it. We show that, in physiologically relevant scenarios, the first cumulant term for random flow and second cumulant term for Brownian motion alone can cancel each other. In such circumstances, assuming pure Brownian motion of RBCs and the first cumulant approximation, a routine practice in DWS/DCS of BFI, can yield good agreement with data, but only because errors due to two incorrect assumptions cancel out. We conclude that correctly assessing random flow from scattered light dynamics requires going beyond the cumulant approximation and propose a more accurate model to do so.

6.
Opt Lett ; 45(21): 5945-5948, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33137037

RESUMEN

Here we provide a counter-example to the conventional wisdom in biomedical optics that longer wavelengths aid deeper imaging in tissue. Specifically, we investigate visible light optical coherence tomography of Bruch's membrane (BM) in the non-pathologic eyes of humans and two mouse strains. Surprisingly, we find that shorter visible wavelengths improve the visualization of BM in pigmented eyes, where it is located behind a highly scattering layer of melanosomes in the retinal pigment epithelium (RPE). Monte Carlo simulations of radiative transport suggest that, while absorption and scattering are higher at shorter wavelengths, detected multiply scattered light from the RPE is preferentially attenuated relative to detected backscattered light from the BM.


Asunto(s)
Luz , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Dispersión de Radiación , Tomografía de Coherencia Óptica/métodos , Animales , Lámina Basal de la Coroides/diagnóstico por imagen , Humanos , Melanosomas/metabolismo , Ratones , Método de Montecarlo , Epitelio Pigmentado de la Retina/citología , Relación Señal-Ruido
7.
Neuroimage ; 202: 116067, 2019 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-31394180

RESUMEN

Studies of flow-metabolism coupling often presume that microvessel architecture is a surrogate for blood flow. To test this assumption, we introduce an in vivo Dynamic Contrast Optical Coherence Tomography (DyC-OCT) method to quantify layer-resolved microvascular blood flow and volume across the full depth of the mouse neocortex, where the angioarchitecture has been previously described. First, we cross-validate average DyC-OCT cortical flow against conventional Doppler OCT flow. Next, with laminar DyC-OCT, we discover that layer 4 consistently exhibits the highest microvascular blood flow, approximately two-fold higher than the outer cortical layers. While flow differences between layers are well-explained by microvascular volume and density, flow differences between subjects are better explained by transit time. Finally, from layer-resolved tracer enhancement, we also infer that microvascular hematocrit increases in deep cortical layers, consistent with predictions of plasma skimming. Altogether, our results show that while the cortical blood supply derives mainly from the pial surface, laminar hemodynamics ensure that the energetic needs of individual cortical layers are met. The laminar trends reported here provide data that links predictions based on the cortical angioarchitecture to cerebrovascular physiology in vivo.


Asunto(s)
Circulación Cerebrovascular/fisiología , Hemodinámica/fisiología , Modelos Neurológicos , Neocórtex/irrigación sanguínea , Neocórtex/fisiología , Animales , Masculino , Ratones , Ratones Endogámicos C57BL , Microvasos/anatomía & histología , Microvasos/fisiología , Tomografía de Coherencia Óptica
8.
Opt Lett ; 44(4): 775-778, 2019 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-30767984

RESUMEN

Visible light optical coherence tomography (OCT) has recently emerged in retinal imaging, with claims of micrometer-scale axial resolution and multi-color (sub-band) imaging. Here, we show that the large dispersion of optical glass and aqueous media, together with broad optical bandwidths often used in visible light OCT, compromises both of these claims. To rectify this, we introduce the notion of spatially dependent (i.e., depth and transverse position-dependent) dispersion. We use a novel sub-band, sub-image correlation algorithm to estimate spatially dependent dispersion in our 109 nm bandwidth visible light OCT mouse retinal imaging system centered at 587 nm. After carefully compensating spatially dependent dispersion, we achieve delineation of fine outer retinal bands in mouse strains of varying pigmentation. Spatially dependent dispersion correction is critical for broader bandwidths and shorter visible wavelengths.

9.
Opt Lett ; 44(17): 4147-4150, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31465349

RESUMEN

In biological tissue, longer near-infrared wavelengths generally experience less scattering and more water absorption. Here we demonstrate an optical coherence tomography (OCT) system centered at 2.1 microns, whose bandwidth falls in the 2.2 micron water absorption optical window, for in vivo imaging of the rodent brain. We show in vivo that at 2.1 microns, the OCT signal is actually attenuated less in cranial bone than at 1.3 microns, and is also less susceptible to multiple scattering tails. We also show that the 2.2 micron window enables direct spectroscopic OCT assessment of tissue water content. We conclude that with further optimization, 2.2 micron OCT will have advantages in low-water-content tissue such as bone, as well as applications where extensive averaging is possible to compensate absorption losses.


Asunto(s)
Encéfalo/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Animales , Encéfalo/metabolismo , Procesamiento de Imagen Asistido por Computador , Ratas , Tomografía de Coherencia Óptica/instrumentación , Agua/metabolismo
10.
Opt Lett ; 43(23): 5881-5884, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-30499965

RESUMEN

Quantifying light transport in turbid media is a long-standing challenge. This challenge arises from the difficulty in experimentally separating unscattered, ballistic light from forward scattered light. Correlation gating is a new approach that numerically separates light paths based on statistical dynamics of the optical field. Here we apply correlation gating with interferometric near-infrared spectroscopy (iNIRS) to separate and independently quantify ballistic and scattered light transmitted through thick samples. First, we present evidence that correlation gating improves the isolation of ballistic light in a thick, intrinsically dynamic medium with Brownian motion. Then, from a single set of iNIRS transmission measurements, we determine the ballistic attenuation coefficient and group refractive index from the time-of-flight (TOF) resolved static intensity, and we determine the reduced scattering and absorption coefficients from the diffusive part of the TOF resolved dynamic intensity. Finally, we show that correlation gating is applicable in intrinsically static media in which motion is induced externally. Thus, for the first time, to the best of our knowledge, the key optical properties of a turbid medium can be derived from a single set of transmission measurements.

12.
Opt Lett ; 42(3): 591-594, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28146535

RESUMEN

Interferometric near-infrared spectroscopy (iNIRS) is a new technique that measures time-of-flight- (TOF-) resolved autocorrelations in turbid media, enabling simultaneous estimation of optical and dynamical properties. Here, we demonstrate reflectance-mode iNIRS for noninvasive monitoring of a mouse brain in vivo. A method for more precise quantification with less static interference from superficial layers, based on separating static and dynamic components of the optical field autocorrelation, is presented. Absolute values of absorption, reduced scattering, and blood flow index (BFI) are measured, and changes in BFI and absorption are monitored during a hypercapnic challenge. Absorption changes from TOF-resolved iNIRS agree with absorption changes from continuous wave NIRS analysis, based on TOF-integrated light intensity changes, an effective path length, and the modified Beer-Lambert Law. Thus, iNIRS is a promising approach for quantitative and noninvasive monitoring of perfusion and optical properties in vivo.


Asunto(s)
Absorción Fisicoquímica , Encéfalo/irrigación sanguínea , Encéfalo/metabolismo , Circulación Cerebrovascular , Interferometría/métodos , Dispersión de Radiación , Espectroscopía Infrarroja Corta/métodos , Animales , Masculino , Ratones
13.
Neuroimage ; 125: 350-362, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26477654

RESUMEN

The transit time distribution of blood through the cerebral microvasculature both constrains oxygen delivery and governs the kinetics of neuroimaging signals such as blood-oxygen-level-dependent functional Magnetic Resonance Imaging (BOLD fMRI). However, in spite of its importance, capillary transit time distribution has been challenging to quantify comprehensively and efficiently at the microscopic level. Here, we introduce a method, called Dynamic Contrast Optical Coherence Tomography (DyC-OCT), based on dynamic cross-sectional OCT imaging of an intravascular tracer as it passes through the field-of-view. Quantitative transit time metrics are derived from temporal analysis of the dynamic scattering signal, closely related to tracer concentration. Since DyC-OCT does not require calibration of the optical focus, quantitative accuracy is achieved even deep in highly scattering brain tissue where the focal spot degrades. After direct validation of DyC-OCT against dilution curves measured using a fluorescent plasma label in surface pial vessels, we used DyC-OCT to investigate the transit time distribution in microvasculature across the entire depth of the mouse somatosensory cortex. Laminar trends were identified, with earlier transit times and less heterogeneity in the middle cortical layers. The early transit times in the middle cortical layers may explain, at least in part, the early BOLD fMRI onset times observed in these layers. The layer-dependencies in heterogeneity may help explain how a single vascular supply manages to deliver oxygen to individual cortical layers with diverse metabolic needs.


Asunto(s)
Circulación Cerebrovascular/fisiología , Hemodinámica/fisiología , Neuroimagen/métodos , Corteza Somatosensorial/irrigación sanguínea , Tomografía de Coherencia Óptica/métodos , Animales , Masculino , Ratones , Ratones Endogámicos C57BL , Microvasos , Oxígeno/sangre
14.
Opt Express ; 24(1): 329-54, 2016 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-26832264

RESUMEN

We introduce and implement interferometric near-infrared spectroscopy (iNIRS), which simultaneously extracts optical and dynamical properties of turbid media through analysis of a spectral interference fringe pattern. The spectral interference fringe pattern is measured using a Mach-Zehnder interferometer with a frequency-swept narrow linewidth laser. Fourier analysis of the detected signal is used to determine time-of-flight (TOF)-resolved intensity, which is then analyzed over time to yield TOF-resolved intensity autocorrelations. This approach enables quantification of optical properties, which is not possible in conventional, continuous-wave near-infrared spectroscopy (NIRS). Furthermore, iNIRS quantifies scatterer motion based on TOF-resolved autocorrelations, which is a feature inaccessible by well-established diffuse correlation spectroscopy (DCS) techniques. We prove this by determining TOF-resolved intensity and temporal autocorrelations for light transmitted through diffusive fluid phantoms with optical thicknesses of up to 55 reduced mean free paths (approximately 120 scattering events). The TOF-resolved intensity is used to determine optical properties with time-resolved diffusion theory, while the TOF-resolved intensity autocorrelations are used to determine dynamics with diffusing wave spectroscopy. iNIRS advances the capabilities of diffuse optical methods and is suitable for in vivo tissue characterization. Moreover, iNIRS combines NIRS and DCS capabilities into a single modality.


Asunto(s)
Interferometría/instrumentación , Rayos Láser , Nefelometría y Turbidimetría/instrumentación , Espectroscopía Infrarroja Corta/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Luz , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad
15.
Opt Lett ; 40(21): 4911-4, 2015 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-26512481

RESUMEN

A spectral/Fourier domain optical coherence tomography (OCT) intravital microscope using a supercontinuum light source at 1.7 µm was developed to study subcortical structures noninvasively in the living mouse brain. The benefits of 1.7 µm for deep tissue brain imaging are demonstrated by quantitatively comparing OCT signal attenuation characteristics of cortical tissue across visible and near-infrared wavelengths. Imaging of hippocampal tissue architecture and white matter microvasculature are demonstrated in vivo through thinned-skull, glass coverslip-reinforced cranial windows in mice. Applications of this novel platform include monitoring disease progression and pathophysiology in rodent models of Alzheimer's disease and subcortical dementias, including vascular dementia.


Asunto(s)
Hipocampo/citología , Microscopía Intravital/instrumentación , Iluminación/instrumentación , Microvasos/citología , Tomografía de Coherencia Óptica/instrumentación , Sustancia Blanca/irrigación sanguínea , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Aumento de la Imagen/métodos , Microscopía Intravital/métodos , Masculino , Ratones , Ratones Endogámicos C57BL , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía de Coherencia Óptica/métodos , Sustancia Blanca/citología
16.
Neuroimage ; 102 Pt 2: 393-406, 2014 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-25111471

RESUMEN

The BOLD (blood-oxygen-level dependent) fMRI (functional Magnetic Resonance Imaging) signal is shaped, in part, by changes in red blood cell (RBC) content and flow across vascular compartments over time. These complex dynamics have been challenging to characterize directly due to a lack of appropriate imaging modalities. In this study, making use of infrared light scattering from RBCs, depth-resolved Optical Coherence Tomography (OCT) angiography was applied to image laminar functional hyperemia in the rat somatosensory cortex. After defining and validating depth-specific metrics for changes in RBC content and speed, laminar hemodynamic responses in microvasculature up to cortical depths of >1mm were measured during a forepaw stimulus. The results provide a comprehensive picture of when and where changes in RBC content and speed occur during and immediately following cortical activation. In summary, the earliest and largest microvascular RBC content changes occurred in the middle cortical layers, while post-stimulus undershoots were most prominent superficially. These laminar variations in positive and negative responses paralleled known distributions of excitatory and inhibitory synapses, suggesting neuronal underpinnings. Additionally, the RBC speed response consistently returned to baseline more promptly than RBC content after the stimulus across cortical layers, supporting a "flow-volume mismatch" of hemodynamic origin.


Asunto(s)
Corteza Somatosensorial/irrigación sanguínea , Corteza Somatosensorial/fisiología , Tomografía de Coherencia Óptica , Animales , Estimulación Eléctrica , Hemodinámica , Masculino , Microvasos/fisiología , Ratas , Ratas Sprague-Dawley
17.
Nat Med ; 13(2): 181-8, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17259996

RESUMEN

Excessive retinal vascular permeability contributes to the pathogenesis of proliferative diabetic retinopathy and diabetic macular edema, leading causes of vision loss in working-age adults. Using mass spectroscopy-based proteomics, we detected 117 proteins in human vitreous and elevated levels of extracellular carbonic anhydrase-I (CA-I) in vitreous from individuals with diabetic retinopathy, suggesting that retinal hemorrhage and erythrocyte lysis contribute to the diabetic vitreous proteome. Intravitreous injection of CA-I in rats increased retinal vessel leakage and caused intraretinal edema. CA-I-induced alkalinization of vitreous increased kallikrein activity and its generation of factor XIIa, revealing a new pathway for contact system activation. CA-I-induced retinal edema was decreased by complement 1 inhibitor, neutralizing antibody to prekallikrein and bradykinin receptor antagonism. Subdural infusion of CA-I in rats induced cerebral vascular permeability, suggesting that extracellular CA-I could have broad relevance to neurovascular edema. Inhibition of extracellular CA-I and kallikrein-mediated innate inflammation could provide new therapeutic opportunities for the treatment of hemorrhage-induced retinal and cerebral edema.


Asunto(s)
Permeabilidad Capilar/efectos de los fármacos , Inhibidores de Anhidrasa Carbónica/uso terapéutico , Anhidrasas Carbónicas/metabolismo , Retinopatía Diabética/tratamiento farmacológico , Proteínas del Ojo/metabolismo , Sistema Calicreína-Quinina/fisiología , Cuerpo Vítreo/enzimología , Acetazolamida/farmacología , Animales , Western Blotting , Antagonistas de los Receptores de Bradiquinina , Inhibidores de Anhidrasa Carbónica/farmacología , Anhidrasas Carbónicas/toxicidad , Complemento C1/antagonistas & inhibidores , Factor XIIa/metabolismo , Humanos , Espectrometría de Masas , Papiledema/inducido químicamente , Proteómica , Ratas , Ratas Sprague-Dawley , Estadísticas no Paramétricas
19.
Biomed Opt Express ; 15(4): 2152-2174, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38633063

RESUMEN

Blood flow index (BFI) is an optically accessible parameter, with unit distance-squared-over-time, that is widely used as a proxy for tissue perfusion. BFI is defined as the dynamic scattering probability (i.e. the ratio of dynamic to overall reduced scattering coefficients) times an effective Brownian diffusion coefficient that describes red blood cell (RBC) motion. Here, using a wavelength division multiplexed, time-of-flight- (TOF) - resolved iNIRS system, we obtain TOF-resolved field autocorrelations at 773 nm and 855 nm via the same source and collector. We measure the human forearm, comprising biological tissues with mixed static and dynamic scattering, as well as a purely dynamic scattering phantom. Our primary finding is that forearm BFI increases from 773 nm to 855 nm, though the magnitude of this increase varies across subjects (23% ± 19% for N = 3). However, BFI is wavelength-independent in the purely dynamic scattering phantom. From these data, we infer that the wavelength-dependence of BFI arises from the wavelength-dependence of the dynamic scattering probability. This inference is further supported by RBC scattering literature. Our secondary finding is that the higher-order cumulant terms of the mean squared displacement (MSD) of RBCs are significant, but decrease with wavelength. Thus, laser speckle and related modalities should exercise caution when interpreting field autocorrelations.

20.
Biomed Opt Express ; 15(4): 2110-2113, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38633102

RESUMEN

A feature issue is being presented by a team of guest editors containing papers based on contributed submissions including studies presented at Optics and the Brain, held April 24-27, 2023 as part of Optica Biophotonics Congress: Optics in the Life Sciences, in Vancouver, Canada.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA