Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Neuroimage ; 232: 117910, 2021 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-33647497

RESUMEN

OBJECT: This study evaluates inter-site and intra-site reproducibility at ten different 7 T sites for quantitative brain imaging. MATERIAL AND METHODS: Two subjects - termed the "traveling heads" - were imaged at ten different 7 T sites with a harmonized quantitative brain MR imaging protocol. In conjunction with the system calibration, MP2RAGE, QSM, CEST and multi-parametric mapping/relaxometry were examined. RESULTS: Quantitative measurements with MP2RAGE showed very high reproducibility across sites and subjects, and errors were in concordance with previous results and other field strengths. QSM had high inter-site reproducibility for relevant subcortical volumes. CEST imaging revealed systematic differences between the sites, but reproducibility was comparable to results in the literature. Relaxometry had also very high agreement between sites, but due to the high sensitivity, differences caused by different applications of the B1 calibration of the two RF coil types used were observed. CONCLUSION: Our results show that quantitative brain imaging can be performed with high reproducibility at 7 T and with similar reliability as found at 3 T for multicenter studies of the supratentorial brain.


Asunto(s)
Encéfalo/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/normas , Imagen por Resonancia Magnética/normas , Adulto , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados
2.
Cerebellum ; 15(1): 21-25, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26521073

RESUMEN

Magnetic resonance imaging (MRI) of the brain is of high interest for diagnosing and understanding degenerative ataxias. Here, we present state-of-the-art MRI methods to characterize structural alterations of the cerebellum and introduce initial experiments to show abnormalities in the cerebellar nuclei. Clinically, T1-weighted MR images are used to assess atrophy of the cerebellar cortex, the brainstem, and the spinal cord, whereas T2-weighted and PD-weighted images are typically employed to depict potential white matter lesions that may be associated with certain types of ataxias. More recently, attention has also focused on the characterization of the cerebellar nuclei, which are discernible on spatially highly resolved iron-sensitive MR images due to their relatively high iron content, including T2 (*)-weighted images, susceptibility-weighted images (SWI), effective transverse relaxation rate (R2 (*)) maps, and quantitative susceptibility maps (QSM). Among these iron-sensitive techniques, QSM reveals the best contrast between cerebellar nuclei and their surroundings. In particular, the gyrification of the dentate nuclei is prominently depicted, even at the clinically widely available field strength of 3 T. The linear relationship between magnetic susceptibility and local iron content allows for determination of iron deposition in cerebellar nuclei non-invasively. The increased signal-to-noise ratio of ultrahigh-field MRI (B0 ≥ 7 T) and advances in spatial normalization methods enable functional MRI (fMRI) at the level of the cerebellar cortex and cerebellar nuclei. Data from initial fMRI studies are presented in three common forms of hereditary ataxias (Friedreich's ataxia, spinocerebellar ataxia type 3, and spinocerebellar ataxia type 6). Characteristic changes in the fMRI signal are discussed in the light of histopathological data and current knowledge of the underlying physiology of the fMRI signal in the cerebellum.


Asunto(s)
Ataxia Cerebelosa/patología , Cerebelo/irrigación sanguínea , Cerebelo/patología , Imagen por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador , Oxígeno/sangre
3.
Brain ; 138(Pt 5): 1182-97, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25818870

RESUMEN

Spinocerebellar ataxia type 3, spinocerebellar ataxia type 6 and Friedreich's ataxia are common hereditary ataxias. Different patterns of atrophy of the cerebellar cortex are well known. Data on cerebellar nuclei are sparse. Whereas cerebellar nuclei have long been thought to be preserved in spinocerebellar ataxia type 6, histology shows marked atrophy of the nuclei in Friedreich's ataxia and spinocerebellar ataxia type 3. In the present study susceptibility weighted imaging was used to assess atrophy of the cerebellar nuclei in patients with spinocerebellar ataxia type 6 (n = 12, age range 41-76 years, five female), Friedreich's ataxia (n = 12, age range 21-55 years, seven female), spinocerebellar ataxia type 3 (n = 10, age range 34-67 years, three female), and age- and gender-matched controls (total n = 23, age range 22-75 years, 10 female). T1-weighted magnetic resonance images were used to calculate the volume of the cerebellum. In addition, ultra-high field functional magnetic resonance imaging was performed with optimized normalization methods to assess function of the cerebellar cortex and nuclei during simple hand movements. As expected, the volume of the cerebellum was markedly reduced in spinocerebellar ataxia type 6, preserved in Friedreich's ataxia, and mildy reduced in spinocerebellar ataxia type 3. The volume of the cerebellar nuclei was reduced in the three patient groups compared to matched controls (P-values < 0.05; two-sample t-tests). Atrophy of the cerebellar nuclei was most pronounced in spinocerebellar ataxia type 6. On a functional level, hand-movement-related cerebellar activation was altered in all three disorders. Within the cerebellar cortex, functional magnetic resonance imaging signal was significantly reduced in spinocerebellar ataxia type 6 and Friedreich's ataxia compared to matched controls (P-values < 0.001, bootstrap-corrected cluster-size threshold; two-sample t-tests). The difference missed significance in spinocerebellar ataxia type 3. Within the cerebellar nuclei, reductions were significant when comparing spinocerebellar ataxia type 6 and Friedreich's ataxia to matched controls (P < 0.01, bootstrap-corrected cluster-size threshold; two-sample t-tests). Susceptibility weighted imaging allowed depiction of atrophy of the cerebellar nuclei in patients with Friedreich's ataxia and spinocerebellar ataxia type 3. In spinocerebellar ataxia type 6, pathology was not restricted to the cerebellar cortex but also involved the cerebellar nuclei. Functional magnetic resonance imaging data, on the other hand, revealed that pathology in Friedreich's ataxia and spinocerebellar ataxia type 3 is not restricted to the cerebellar nuclei. There was functional involvement of the cerebellar cortex despite no or little structural changes.


Asunto(s)
Corteza Cerebelosa/patología , Núcleos Cerebelosos/patología , Ataxia de Friedreich/patología , Enfermedad de Machado-Joseph/patología , Imagen por Resonancia Magnética , Ataxias Espinocerebelosas/patología , Adulto , Anciano , Atrofia , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Degeneraciones Espinocerebelosas/patología
4.
Front Cardiovasc Med ; 10: 1068390, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37255709

RESUMEN

A key step in translational cardiovascular research is the use of large animal models to better understand normal and abnormal physiology, to test drugs or interventions, or to perform studies which would be considered unethical in human subjects. Ultrahigh field magnetic resonance imaging (UHF-MRI) at 7 T field strength is becoming increasingly available for imaging of the heart and, when compared to clinically established field strengths, promises better image quality and image information content, more precise functional analysis, potentially new image contrasts, and as all in-vivo imaging techniques, a reduction of the number of animals per study because of the possibility to scan every animal repeatedly. We present here a solution to the dual use problem of whole-body UHF-MRI systems, which are typically installed in clinical environments, to both UHF-MRI in large animals and humans. Moreover, we provide evidence that in such a research infrastructure UHF-MRI, and ideally combined with a standard small-bore UHF-MRI system, can contribute to a variety of spatial scales in translational cardiovascular research: from cardiac organoids, Zebra fish and rodent hearts to large animal models such as pigs and humans. We present pilot data from serial CINE, late gadolinium enhancement, and susceptibility weighted UHF-MRI in a myocardial infarction model over eight weeks. In 14 pigs which were delivered from a breeding facility in a national SARS-CoV-2 hotspot, we found no infection in the incoming pigs. Human scanning using CINE and phase contrast flow measurements provided good image quality of the left and right ventricle. Agreement of functional analysis between CINE and phase contrast MRI was excellent. MRI in arrested hearts or excised vascular tissue for MRI-based histologic imaging, structural imaging of myofiber and vascular smooth muscle cell architecture using high-resolution diffusion tensor imaging, and UHF-MRI for monitoring free radicals as a surrogate for MRI of reactive oxygen species in studies of oxidative stress are demonstrated. We conclude that UHF-MRI has the potential to become an important precision imaging modality in translational cardiovascular research.

5.
PLoS One ; 17(6): e0270689, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35767553

RESUMEN

BACKGROUND: To investigate the effects of B1-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). METHODS: Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field. RESULTS: B1-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B1-shimming showed shading artifacts due to local B1+-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B1-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B1-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study. CONCLUSIONS: B1-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.


Asunto(s)
Vasos Coronarios , Ondas de Radio , Constricción Patológica , Vasos Coronarios/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados
6.
Sci Rep ; 10(1): 3117, 2020 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-32080274

RESUMEN

A novel mono-surface antisymmetric 16-element transmit/receive (Tx/Rx) coil array was designed, simulated, constructed, and tested for cardiac magnetic resonance imaging (cMRI) in pigs at 7 T. The cardiac array comprised of a mono-surface 16-loops with two central elements arranged anti-symmetrically and flanked by seven elements on either side. The array was configured for parallel transmit (pTx) mode to have an eight channel transmit and 16-channel receive (8Tx/16Rx) coil array. Electromagnetic (EM) simulations, bench-top measurements, phantom, and MRI experiments with two pig cadavers (68 and 46 kg) were performed. Finally, the coil was used in pilot in-vivo measurements with a 60 kg pig. Flip angle (FA), geometry factor (g-factor), signal-to-noise ratio (SNR) maps, and high-resolution cardiac images were acquired with an in-plane resolution of 0.6 mm × 0.6 mm (in-vivo) and 0.3 mm × 0.3 mm (ex-vivo). The mean g-factor over the heart was 1.26 (R = 6). Static phase [Formula: see text] shimming in a pig body phantom with the optimal phase vectors makes possible to improve the [Formula: see text] homogeneity by factor > 2 and transmit efficiency by factor > 3 compared to zero phases (before RF shimming). Parallel imaging performed in the in-vivo measurements demonstrated well preserved diagnostic quality of the resulting images at acceleration factors up to R = 6. The described hardware design can be adapted for arrays optimized for animals and humans with a larger number of elements (32-64) while maintaining good decoupling for various MRI applications at UHF (e.g., cardiac, head, and spine).


Asunto(s)
Ingeniería Biomédica/instrumentación , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Animales , Cadáver , Radiación Electromagnética , Diseño de Equipo , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Relación Señal-Ruido , Porcinos
7.
Neurosci Lett ; 662: 167-172, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29054435

RESUMEN

Anxiety disorders can be conceptualized by an abnormal interplay of emotion-processing brain circuits; however, knowledge of brain connectivity measures in specific phobia is still limited. To explore functional interactions within selected fear-circuitry structures (anterior cingulate cortex (ACC), amygdala, insula), we re-examined three task-based fMRI studies using a symptom provocation approach (n=94 subjects in total) on two different phobia subtypes (animal subtype as represented by snake phobia (SP) and blood-injection-injury subtype as represented by dental phobia (DP)), and a non-phobic healthy control group (HC). Functional connectivity (FC) analyses detected a negative coupling between the amygdala and the ACC in HC for both classes of phobic stimuli, while SP and DP lacked this inhibitory relationship during visual stimulus presentation. However, a negative FC between the insula and the amygdala was observed in DP during visual symptom provocation, which reversed to a positive FC under auditory symptom provocation pointing to effects depending on stimulus modality in DP. SP showed significantly higher FC towards snake-anxiety eliciting stimuli than HC on an average measure of FC, while DP showed a similar pattern under auditory stimulation only. These findings altogether indicate FC shifts during symptom provocation in specific phobia possibly reflecting impaired emotion regulation processes within fear-circuitry networks. FC hence could represent a prime target for neuroscience-informed augmentation strategies when treating pathological forms of fear.


Asunto(s)
Encéfalo/fisiopatología , Trastornos Fóbicos/fisiopatología , Adulto , Amígdala del Cerebelo/fisiopatología , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Corteza Cerebral/fisiopatología , Miedo/fisiología , Femenino , Giro del Cíngulo/fisiopatología , Humanos , Imagen por Resonancia Magnética , Masculino , Vías Nerviosas/fisiopatología , Trastornos Fóbicos/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS