Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37265253

RESUMEN

AIMS: The past decade has seen an increased delivery of cardiac resynchronization therapy (CRT) for patients with heart failure (HF). We explored whether clinical outcomes after CRT have changed from the perspective of an entire public healthcare system. METHODS AND RESULTS: A national database covering the population of England (56.3 million in 2019) was used to explore clinical outcomes after CRT from 2010 to 2019. A total of 64 698 consecutive patients (age 71.4 ± 11.7 years; 74.8% male) underwent CRT-defibrillation [n = 32 313 (49.7%)] or CRT-pacing [n = 32 655 (50.3%)] implantation. From 2010-2011 to 2018-2019, there was a 76% increase in CRT implantations. During the same period, the proportion of patients with hypertension (59.6-73.4%), diabetes (26.5-30.8%), and chronic kidney disease (8.62-22.5%) increased, as did the Charlson comorbidity index (CCI ≥ 3 from 20.0% to 25.1%) (all P < 0.001). Total mortality decreased at 30 days (1.43-1.09%) and 1 year (9.51-8.13%) after implantation (both P < 0.001). At 2 years, total mortality [hazard ratio (HR): 0.72; 95% confidence interval (CI) 0.69-0.76] and total mortality or HF hospitalization (HR: 0.59; 95% CI 0.57-0.62) decreased from 2010-2011 to 2018-2019, after correction for age, race, sex, device type (CRT-defibrillation or pacing), comorbidities (hypertension, diabetes, chronic kidney disease, and myocardial infarction), or the CCI (HR: 0.81; 95% CI 0.77-0.85). CONCLUSIONS: From the perspective of an entire public health system, survival has improved and HF hospitalizations have decreased after CRT implantation over the past decade. This prognostic improvement has occurred despite an increasing comorbidity burden.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Diabetes Mellitus , Insuficiencia Cardíaca , Hipertensión , Insuficiencia Renal Crónica , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Terapia de Resincronización Cardíaca/efectos adversos , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Pronóstico , Hipertensión/diagnóstico , Hipertensión/epidemiología , Hipertensión/terapia , Insuficiencia Renal Crónica/terapia
2.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36944529

RESUMEN

AIMS: The optimum timing of cardiac resynchronization therapy (CRT) implantation is unknown. We explored long-term outcomes after CRT in relation to the time interval from a first heart failure hospitalization (HFH) to device implantation. METHODS AND RESULTS: A database covering the population of England (56.3 million in 2019) was used to quantify clinical outcomes after CRT implantation in relation to first HFHs. From 2010 to 2019, 64 968 patients [age: 71.4 ± 11.7 years; 48 606 (74.8%) male] underwent CRT implantation, 57% in the absence of a previous HFH, 12.9% during the first HFH, and 30.1% after ≥1 HFH. Over 4.54 (2.80-6.71) years [median (interquartile range); 272 989 person-years], the time in years from the first HFH to CRT implantation was associated with a higher risk of total mortality [hazard ratio (HR); 95% confidence intervals (95% CI)] (1.15; 95% CI 1.14-1.16, HFH (HR: 1.26; 95% CI 1.24-1.28), and the combined endpoint of total mortality or HFH (HR: 1.19; 95% CI 1.27-1.20) than CRT in patients with no previous HFHs, after co-variate adjustment. Total mortality (HR: 1.67), HFH (HR: 2.63), and total mortality or HFH (HR: 1.92) (all P < 0.001) were highest in patients undergoing CRT ≥2 years after the first HFH. CONCLUSION: In this study of a healthcare system covering an entire nation, delays from a first HFH to CRT implantation were associated with progressively worse long-term clinical outcomes. The best clinical outcomes were observed in patients with no previous HFH and in those undergoing CRT implantation during the first HFH. CONDENSED ABSTRACT: The optimum timing of CRT implantation is unknown. In this study of 64 968 consecutive patients, delays from a first heart failure hospitalization (HFH) to CRT implantation were associated with progressively worse long-term clinical outcomes. Each year from a first HFH to CRT implantation was associated with a 21% higher risk of total mortality and a 34% higher risk of HFH. The best outcomes after CRT were observed in patients with no previous HFHs and in those undergoing implantation during their first HFH.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Inglaterra
3.
Pacing Clin Electrophysiol ; 46(2): 114-124, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36385259

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) offer effective therapy for the prevention of sudden cardiac death (SCD) due to ventricular arrhythmias. However, inappropriate shocks have detrimental effects on survival and quality of life. The addition of hemodynamic monitoring may be useful in discriminating clinically important ventricular arrhythmias. OBJECTIVE: In this study, we assess the ability of laser Doppler flowmetry to assess the hemodynamic effect of paced atrial and ventricular arrhythmias using mean arterial blood pressure as the reference. METHODS: In this acute human study in patients undergoing an elective electrophysiological study, laser Doppler flowmetry, arterial blood pressure, and surface ECG were acquired during high-rate atrial and ventricular pacing to simulate supraventricular and ventricular tachycardias. RESULTS: Arterial blood pressure and laser Doppler flow signals correlated well during atrial and ventricular pacing (rho = 0.694, p < .001). The hemodynamic impairment detected by both methods was greater during ventricular pacing than atrial pacing (-1.0% vs. 19.0%, p < .001). Laser Doppler flowmetry performed better than rate alone to identify hemodynamic impairments. CONCLUSION: In this acute study, laser Doppler flowmetry tissue perfusion served as a good surrogate measure for arterial pressure, which could be incorporated into future ICDs.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Fibrilación Atrial/terapia , Calidad de Vida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Muerte Súbita Cardíaca/prevención & control , Rayos Láser
4.
Europace ; 24(1): 31-39, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34379762

RESUMEN

AIMS: To determine whether myocardial fibrosis and greyzone fibrosis (GZF) on cardiovascular magnetic resonance (CMR) is associated with ventricular arrhythmias in patients with coronary artery disease (CAD) and a left ventricular ejection fraction (LVEF) >35%. METHODS AND RESULTS: In this retrospective study of CAD patients, GZF mass using the 3SD method (GZF3SD) and total fibrosis mass using the 2SD method (TF2SD) on CMR were assessed in relation to the primary, combined endpoint of sudden cardiac death, ventricular tachycardia, ventricular fibrillation, or resuscitated cardiac arrest. Among 701 patients [age: 65.8 ± 12.3 years (mean ± SD)], 28 (3.99%) patients met the primary endpoint over 5.91 years (median; interquartile range 4.42-7.64). In competing risks analysis, a GZF3SD mass ≥5.0 g was strongly associated with the primary endpoint [subdistribution hazard ratio (sHR): 17.4 (95% confidence interval, CI 6.64-45.5); area under receiver operator characteristic curve (AUC): 0.85, P < 0.001]. A weaker association was observed for TF2SD mass ≥23 g [sHR 10.4 (95% CI 4.22-25.8); AUC: 0.80, P < 0.001]. The range of sHRs for GZF3SD mass (1-527) was wider than for TF2SD mass (1-37.6). CONCLUSIONS: In CAD patients with an LVEF >35%, GZF3SD mass was strongly associated with the arrhythmic endpoint. These findings hold promise for its use in identifying patients with CAD and an LVEF >35% at risk of arrhythmic events.


Asunto(s)
Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/patología , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/patología , Fibrosis , Humanos , Persona de Mediana Edad , Miocardio/patología , Estudios Retrospectivos , Volumen Sistólico
5.
Pacing Clin Electrophysiol ; 45(9): 1075-1084, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35899803

RESUMEN

BACKGROUND: Right ventricular (RV) dysfunction has been linked to a poor response to cardiac resynchronization therapy (CRT). We sought to determine whether cardiovascular magnetic resonance (CMR)-derived measures of RV function influence clinical outcomes after CRT. METHODS: In this retrospective study, we used CMR to assess pre-implant RV volumes and RV ejection fraction (RVEF) in relation to clinical outcomes after CRT implantation. RESULTS: Among 243 patients (age: 70.3 ± 10.8 years [mean ± SD]; 68.7% male; 121 [49.8%]) with ischemic cardiomyopathy and 122 (50.2%) with nonischemic cardiomyopathy, 141 (58%) after CRT-defibrillation (CRT-D) and 102 (42%) after CRT-pacing (CRT-P), 101 (41.6.0%) patients died, 61 (25.1%) from cardiac causes and 24 (9.88%) from noncardiac causes, over 5.87 years (median; interquartile range: 4.35-7.73). Two (0.82%) patients underwent cardiac transplantation and four (1.64%) had a left ventricular assist device (LVAD). A total of 41 (16.9%) met the composite endpoint of sudden cardiac death (SCD), ventricular tachycardia, or ventricular fibrillation. In univariate analyses, no measure of RV function was associated with total mortality or the arrhythmic endpoint. RVEF was associated with cardiac mortality on univariate analyses (HR per 10%: 0.82, 95% CI 0.70-0.96), but not on multivariate analyses that included left ventricular ejection fraction. CONCLUSIONS: There is no relationship between measures of RV function, such as RV volumes and RVEF, and the long-term clinical outcome of CRT. These findings indicate that such measures should not be considered in patient selection.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Insuficiencia Cardíaca , Disfunción Ventricular Derecha , Anciano , Anciano de 80 o más Años , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/terapia , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Derecha/terapia , Función Ventricular Izquierda , Función Ventricular Derecha
6.
Indian Pacing Electrophysiol J ; 22(1): 54-57, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34775047

RESUMEN

Anti-tachycardia pacing (ATP) is frequently used to terminate ventricular tachycardia (VT), however it is not always successful and may accelerate VT requiring defibrillation. REVRAMP is a novel concept of ATP that involves delivering pacing at a faster rate than VT, but instead of abruptly terminating pacing after eight beats, pacing is gradually slowed until VT continues or normal rhythm is restored. In a pilot study we show that REVRAMP can restore normal rhythm, and that if REVRAMP is unsuccessful, VT is not accelerated.

7.
Europace ; 23(6): 928-936, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33778881

RESUMEN

AIMS: The COVID-19 pandemic has led to a decline in hospitalizations for non-COVID-19-related conditions. We explored the impact of the COVID-19 pandemic on cardiac operations and interventions undertaken in England. METHODS AND RESULTS: An administrative database covering hospital activity for England, the Health Episodes Statistics, was used to assess a total of 286 697 hospitalizations for cardiac operations and interventions, as well as 227 257 hospitalizations for myocardial infarction (MI) and 453 799 for heart failure (HF) from 7 January 2019 to 26 July 2020. Over the 3 months of 'lockdown', total numbers and mean reductions in weekly rates [n (-%)], compared with the same time period in 2019, were: coronary artery bypass grafting [-2507 (-64%)]; percutaneous coronary intervention [-5245 (-28%)]; surgical [-1324 (-41%)] and transcatheter [-284 (-21%)] aortic valve replacement; mitral valve replacement; implantation of pacemakers [-6450 (-44%)], cardiac resynchronization therapy with [-356 (-42%)] or without [-491 (-46%)] defibrillation devices, and implantable cardioverter-defibrillators [-501 (-45%)]; atrial fibrillation ablation [-1902 (-83%)], and other ablations [-1712 (-64%)] (all P < 0.001). Over this period, there were 21 038 fewer procedures than in the reference period in 2019 (P < 0.001). These changes paralleled reductions in hospitalizations for MI [-10 794 (-27%)] and HF [-63 058 (-28%)] (both P < 0.001). CONCLUSIONS: The COVID-19 pandemic has led to substantial reductions in the number of cardiac operations and interventions undertaken. An alternative strategy for healthcare delivery to patients with cardiac conditions during the COVID-19 pandemic is urgently needed.


Asunto(s)
COVID-19 , Pandemias , Control de Enfermedades Transmisibles , Inglaterra , Humanos , SARS-CoV-2
8.
Europace ; 22(6): 956-963, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32285097

RESUMEN

AIMS: Incidental left bundle branch block (iLBBB) is a frequent cause for cardiology referrals. In such instances, there is uncertainty as to its prognosis. We sought to determine the utility of cardiovascular magnetic resonance (CMR) in the risk stratification of patients with iLBBB. METHODS AND RESULTS: Clinical events were collected in patients with iLBBB who had CMR. Controls had no cardiac symptoms or cardiac disease, a normal CMR scan and electrocardiogram. Amongst patients with iLBBB [n = 193, aged 62.7 ± 12.6 years (mean ± SD)], 110/193 (56.9%) had an abnormal phenotype (iLBBBCMR+) and 83/110 (43.0%) had a normal phenotype (iLBBBCMR-). Over 3.75 years (median; inter-quartile range: 2.7-5.5), iLBBBCMR+ had a higher total mortality [adjusted hazard ratio (aHR) 6.49, 95% confidence interval (CI) 1.91-22.0] and total mortality or major adverse cardiac events (MACEs; aHR 9.15, 95% CI 2.56-32.6) than controls (n = 107). In contrast, iLBBBCMR- had a similar risk of total mortality compared with controls, but total mortality or MACEs was higher (aHR 4.24, 95% CI 1.17-15.4; P = 0.028). Amongst iLBBB patients, both myocardial fibrosis (aHR 5.15, 95% CI 1.53-17.4) and left ventricular ejection fraction (LVEF) ≤ 50% (aHR 3.88, 95% CI 1.67-9.06) predicted total mortality. Myocardial fibrosis plus LVEF ≤50% was associated with the highest risk of total mortality (aHR: 9.87, 95% CI 2.99-32.6) and total mortality or MACEs (aHR 3.98, 95% CI 1.73-9.11). CONCLUSIONS: Outcomes in iLBBBCMR+ were poor whereas survival in iLBBBCMR- was comparable with controls. Myocardial fibrosis and LVEF <50% had an additive effect on the risk of clinical outcomes. A CMR scan is pivotal in risk-stratifying patients with iLBBB.


Asunto(s)
Bloqueo de Rama , Función Ventricular Izquierda , Bloqueo de Rama/diagnóstico , Electrocardiografía , Humanos , Pronóstico , Volumen Sistólico
9.
J Cardiovasc Electrophysiol ; 30(9): 1610-1619, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31115945

RESUMEN

INTRODUCTION: New pacing technologies offer a greater choice of left ventricular pacing sites and greater personalization of cardiac resynchronization therapy (CRT). The effects on cardiac function of novel pacing configurations are often compared using multi-beat averages of acute hemodynamic measurements. In this analysis of the iSpot trial, we explore whether this is sufficient. MATERIALS AND METHODS: The iSpot trial was an international, prospective, acute hemodynamic trial that assessed seven CRT configurations: standard CRT, MultiSpot (posterolateral vein), and MultiVein (anterior and posterior vein) pacing. Invasive and noninvasive blood pressure, and left ventricular (LV) dP/dtmax were recorded. Eight beats were recorded before and after an alternation from AAI to the tested pacing configuration and vice-versa. Eight alternations were performed for each configuration at each of the five atrioventricular delays. RESULTS: Twenty-five patients underwent the full protocol of eight alternations. Only four (16%) patients had a statistically significant >3 mm Hg improvement over conventional CRT configuration (posterolateral vein, distal electrode). However, if only one alternation was analyzed (standard multi-beat averaging protocol), 15 (60%) patients falsely appeared to have a superior nonconventional configuration. Responses to pacing were significantly correlated between the different hemodynamic measures: invasive systolic blood pressure (SBP) vs noninvasive SBP r = 0.82 (P < .001); invasive SBP vs LV dP/dt r = 0.57, r2 = 0.32 (P < .001). CONCLUSIONS: Current standard multibeat acquisition protocols are unfortunately unable to prevent false impressions of optimality arising in individual patients. Personalization processes need to include distinct repeated transitions to the tested pacing configuration in addition to averaging multiple beats. The need is not only during research stages but also during clinical implementation.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Monitorización Hemodinámica , Hemodinámica , Presión Sanguínea , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Presión Ventricular
10.
Europace ; 20(FI1): f13-f19, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29016773

RESUMEN

Aims: The identification of arrhythmogenic right ventricular dysplasia (ARVD) from 12-channel standard electrocardiogram (ECG) is challenging. High density ECG data may identify lead locations and criteria with a higher sensitivity. Methods and results: Eighty-channel ECG recording from patients diagnosed with ARVD and controls were quantified by magnitude and integral measures of QRS and T waves and by a measure (the average silhouette width) of differences in the shapes of the normalized ECG cycles. The channels with the best separability between ARVD patients and controls were near the right ventricular wall, at the third intercostal space. These channels showed pronounced differences in P waves compared to controls as well as the expected differences in QRS and T waves. Conclusion: Multichannel recordings, as in body surface mapping, add little to the reliability of diagnosing ARVD from ECGs. However, repositioning ECG electrodes to a high anterior position can improve the identification of ECG variations in ARVD. Additionally, increased P wave amplitude appears to be associated with ARVD.


Asunto(s)
Potenciales de Acción , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Electrocardiografía , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Adulto , Anciano , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Estudios de Casos y Controles , Electrocardiografía/instrumentación , Femenino , Ventrículos Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico
11.
J Cardiovasc Electrophysiol ; 28(2): 192-200, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27885752

RESUMEN

INTRODUCTION: Vectorcardiographic (VCG) QRS area of left bundle branch block (LBBB) predicts acute hemodynamic response in cardiac resynchronization therapy (CRT) patients. We hypothesized that changes in QRS area occurring with biventricular pacing (BV) might predict acute hemodynamic CRT response (AHR). METHODS AND RESULTS: VCGs of 624 BV paced electrocardiograms (25 LBBB patients with 35 different pacing configurations) were calculated according to Frank's orthogonal lead system. Maximum QRS vector amplitudes (XAmpl , YAmpl , ZAmpl , and 3DAmp ) and QRS areas (XArea , YArea , ZArea , and 3DArea ) in the orthogonal leads (X, Y, and Z) and in 3-dimensional projection were measured. Volume of the 3D vector loop and global QRS duration (QRSD) on the surface electrocardiogram were assessed. Differences (Δ) in VCG parameters between BV paced and LBBB QRS complexes were calculated. An increase of 10% in dP/dt max was considered as AHR. LBBB conduction is characterized by a large ZArea (109 µVs, interquartile range [IQR]:75;135), significantly larger than XArea (22 µVs, IQR:10;57) and YArea (44 µVs, IQR:32;62, P < 0.001). Overall, QRS duration, amplitudes, and areas decrease significantly with BV pacing (P < 0.001). Of all VCG parameters, 3DAmpl , Δ3DAmpl , ZArea, ΔZArea , Δ3DArea , and ΔQRSD differentiate AHR response from nonresponse (P < 0.05). ΔZArea predicted best positive AHR (area under the curve = 0.813) and outperformed any other VCG parameter or QRSD measurement. CONCLUSION: Of all VCG parameters, reduction in QRS area, calculated in Frank's Z lead, predicts acute hemodynamic response best. This method might be an easy, noninvasive tool to guide CRT implantation and optimization.


Asunto(s)
Potenciales de Acción , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Electrocardiografía , Frecuencia Cardíaca , Anciano , Área Bajo la Curva , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medio Oriente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Vectorcardiografía , Función Ventricular Izquierda
12.
J Cardiovasc Magn Reson ; 18: 1, 2016 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-26732096

RESUMEN

BACKGROUND: Left ventricular (LV) mid-wall fibrosis (MWF), which occurs in about a quarter of patients with non-ischemic cardiomyopathy (NICM), is associated with high risk of pump failure. The mid LV wall is the site of circumferential myocardial fibers. We sought to determine the effect of MWF on LV myocardial mechanics. METHODS: Patients with NICM (n = 116; age: 62.8 ± 13.2 years; 67% male) underwent late gadolinium enhancement cardiovascular magnetic resonance (CMR) and were categorized according to the presence (+) or absence (-) of MWF. Feature tracking (FT) CMR was used to assess myocardial deformation. RESULTS: Despite a similar LVEF (24.3 vs. 27.5%, p = 0.20), patients with MWF (32 [24%]) had lower global circumferential strain (Ɛcc: -6.6% vs. -9.4 %, P = 0.004), but similar longitudinal (Ɛll: -7.6 % vs. -9.4 %, p = 0.053) and radial (Ɛrr: 14.6% vs. 17.8% p = 0.18) strain. Compared with - MWF, + MWF was associated with reduced LV systolic, circumferential strain rate (-0.38 ± 0.1 vs. -0.56 ± 0.3 s(-1), p = 0.005) and peak LV twist (4.65 vs. 6.31°, p = 0.004), as well as rigid LV body rotation (64 % vs. 28 %, P <0.001). In addition, +MWF was associated with reduced LV diastolic strain rates (DSRcc: 0.34 vs. 0.46 s(-1); DSRll: 0.38 vs. 0.50s(-1); DSRrr: -0.55 vs. -0.75 s(-1); all p <0.05). CONCLUSIONS: MWF is associated with reduced LV global circumferential strain, strain rate and torsion. In addition, MWF is associated with rigid LV body rotation and reduced diastolic strain rates. These systolic and diastolic disturbances may be related to the increased risk of pump failure observed in patients with NICM and MWF.


Asunto(s)
Cardiomiopatías/diagnóstico , Ventrículos Cardíacos/fisiopatología , Miocardio/patología , Función Ventricular Izquierda , Anciano , Fenómenos Biomecánicos , Cardiomiopatías/complicaciones , Cardiomiopatías/patología , Cardiomiopatías/fisiopatología , Medios de Contraste , Diástole , Inglaterra , Femenino , Fibrosis , Gadolinio DTPA , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/patología , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estrés Mecánico , Sístole , Torsión Mecánica
13.
Europace ; 18(8): 1227-34, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26718535

RESUMEN

AIMS: The clinical response to cardiac resynchronization therapy (CRT) is variable. Multipoint left ventricular (LV) pacing could achieve more effective haemodynamic response than single-point LV pacing. Deployment of an LV lead over myocardial scar is associated with a poor haemodynamic response to and clinical outcome of CRT. We sought to determine whether the acute haemodynamic response to CRT using three-pole LV multipoint pacing (CRT3P-MPP) is superior to that to conventional CRT using single-site LV pacing (CRTSP) in patients with ischaemic cardiomyopathy and an LV free wall scar. METHODS AND RESULTS: Sixteen patients with ischaemic cardiomyopathy [aged 72.6 ± 7.7 years (mean ± SD), 81.3% male, QRS: 146.0 ± 14.2 ms, LBBB in 14 (87.5%)] in whom the LV lead was intentionally deployed straddling an LV free wall scar (assessed using cardiac magnetic resonance), underwent assessment of LV + dP/dtmax during CRT3P-MPP and CRTSP. Interindividually, the ΔLV + dP/dtmax in relation to AAI pacing with CRT3P-MPP (6.2 ± 13.3%) was higher than with basal and mid CRTSP (both P < 0.001), but similar to apical CRTSP. Intraindividually, significant differences in the ΔLV + dP/dtmax to optimal and worst pacing configurations were observed in 10 (62.5%) patients. Of the 8 patients who responded to at least one configuration, CRT3P-MPP was optimal in 5 (62.5%) and apical CRTSP was optimal in 3 (37.5%) (P = 0.0047). CONCLUSIONS: In terms of acute haemodynamic response, CRT3P-MPP was comparable an apical CRTSP and superior to basal and distal CRTSP. In the absence of within-device haemodynamic optimization, CRT3P-MPP may offer a haemodynamic advantage over a fixed CRTSP configuration.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/complicaciones , Cicatriz/complicaciones , Insuficiencia Cardíaca/terapia , Isquemia Miocárdica/complicaciones , Anciano , Anciano de 80 o más Años , Dispositivos de Terapia de Resincronización Cardíaca , Diseño de Equipo , Femenino , Ventrículos Cardíacos/fisiopatología , Hemodinámica , Humanos , Masculino , Reino Unido , Función Ventricular Izquierda
14.
Br J Nutr ; 111(7): 1245-52, 2014 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-24286443

RESUMEN

Current evidence suggests that regenerative v. degenerative endothelial responses can be integrated in a clinical endothelial phenotype, reflecting the net result between damage from risk factors and endogenous repair capacity. We have previously shown that a cocoa flavanol (CF) intervention can improve endothelial function and increase the regenerative capacity of the endothelium by mobilising circulating angiogenic cells in patients with coronary artery disease (CAD). The aim of the present study was to investigate whether CF can lower the levels of circulating endothelial microparticles (EMP), markers of endothelial integrity, along with improvements in endothelial function. The levels of EMP in the frozen plasma samples of CAD patients were measured along with endothelial function (flow-mediated vasodilation, FMD); n 16, FMD data published previously), and these data were compared with those of young (n 12) and age-matched (n 12) healthy control subjects. The CAD patients exhibited significantly increased levels of EMP along with impaired FMD when compared with the healthy control subjects. The levels of CD144⁺ and CD31⁺/41⁻ EMP were inversely correlated with FMD (r -0.67, P=0.01 and r -0.59, P=0.01, respectively). In these CAD patients, the levels of EMP were measured after they had consumed a drink containing 375 mg of CF (high-CF intervention, HiFI) or 9 mg of CF (macro- and micronutrient-matched low-CF control, LoFl) twice daily over a 30-d period in a randomised, double-blind, cross-over study. After 1 month of HiFI, the levels of CD31⁺/41⁻ and CD144⁺ EMP decreased (-25 and -23%, respectively), but not after LoFl. Our data show that flavanols lower the levels of EMP along with higher endothelial function, lending evidence to the novel concept that flavanols may improve endothelial integrity.


Asunto(s)
Micropartículas Derivadas de Células/patología , Enfermedad de la Arteria Coronaria/dietoterapia , Suplementos Dietéticos , Endotelio Vascular/patología , Flavonoles/uso terapéutico , Adulto , Anciano , Antígenos CD/sangre , Biomarcadores/sangre , Arteria Braquial/diagnóstico por imagen , Cacao/química , Cadherinas/sangre , Micropartículas Derivadas de Células/metabolismo , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/fisiopatología , Estudios Cruzados , Estudios Transversales , Método Doble Ciego , Endotelio Vascular/diagnóstico por imagen , Endotelio Vascular/metabolismo , Endotelio Vascular/fisiopatología , Femenino , Frutas/química , Humanos , Masculino , Persona de Mediana Edad , Molécula-1 de Adhesión Celular Endotelial de Plaqueta/sangre , Valores de Referencia , Ultrasonografía , Adulto Joven
15.
EJVES Vasc Forum ; 61: 92-98, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38455254

RESUMEN

Objective: Thoracic outlet syndrome (TOS) is a rare disorder mostly seen in younger individuals. Although patient wellbeing is relevantly impaired, it often takes a long time before the diagnosis is made. Digital subtraction angiography (DSA) is routinely used despite its radiation exposure, which is a major concern in this young patient population. Moreover, DSA offers limited opportunities for functional assessment. By contrast, ultrasonography is widely accessible without causing radiation exposure and allows for flexible functional assessment. The main goal of the study was to investigate whether ultrasound (US) was a viable alternative to DSA in diagnosing arterial TOS (aTOS). Methods: Patients, referred to a tertiary centre for evaluation of suspected TOS, were recruited into the study. DSA was routinely performed with the patient's arms both in the raised (abducted) and neutral (adducted) position. Two vascular surgeons and two radiologists assessed the resulting images for the presence of aTOS. Additionally, two examiners performed US according to a standardised protocol. The reference for presence of aTOS was the DSA based interdisciplinary vascular conference consensus. Inter-rater agreement and latent class analysis (LCA) were performed between assessors and diagnostic methods. Results: Fifty one consecutive patients (two thirds female) aged 39.3 ± 13.0 years were included within 11 months. US agreement was excellent at 0.94 (0.841-0.980), DSA agreement for vascular surgeons was good at 0.779 (0.479-1.000), whereas it was moderate at 0.546 (0.046-1.000) for radiologists. Results suggest that DSA is untenable as the gold standard for aTOS diagnosis. In LCA, US was shown to be a reliable diagnostic tool for the detection of aTOS. Conclusion: US examination is a valid test for the detection of haemodynamically relevant compression of arteries in the diagnostic work up of aTOS using a standardised protocol. The role of DSA as the gold standard should be reviewed and needs to be reconsidered.

16.
Pacing Clin Electrophysiol ; 36(1): 63-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23121169

RESUMEN

AIMS: The role of right bundle branch block (RBBB) for the induction of left ventricular (LV) asynchrony is discussed controversially. The objective of this study was to assess presence and degree of LV asynchrony in patients with RBBB, left bundle branch block (LBBB), or left anterior hemiblock (LAH) and normal LV function. METHODS: We included 15 patients with RBBB, 13 patients with RBBB and concomitant LAH, 10 patients with pure LBBB, and 100 healthy controls into this study. All patients had normal LV function. Interventricular asynchrony was assessed as the difference of the right and LV ejection delay. Intraventricular delay was obtained by tissue synchronicity imaging-guided tissue Doppler imaging measurement. RESULTS: Interventricular and left intraventricular asynchrony were linked to the presence of an LBBB. No left intraventricular asynchrony was noted during pure RBBB; interventricular delays were negative (aortic flow preceding pulmonary flow) in the presence of RBBB. CONCLUSION: In patients with normal LV function, intraventricular asynchrony depends on the presence of an LBBB and interventricular asynchrony is inversed in the presence of RBBB.


Asunto(s)
Bloqueo de Rama/complicaciones , Bloqueo de Rama/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Pacing Clin Electrophysiol ; 36(2): 214-20, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23121136

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) can improve clinical and cardiac structural status in heart failure patients. The role of baseline diastolic echocardiographic parameters to characterize the likelihood of positive outcomes is not well known. We explored relationships between diastolic parameters and outcomes 6 months after CRT implant in the Predictors of Response to CRT (PROSPECT) Trial. HYPOTHESIS: We hypothesized that diastolic echocardiographic parameters were associated with clinical and structural outcomes in CRT patients. METHODS: For 426 patients in PROSPECT, a prospective observational trial of CRT, baseline E/A ratio, left atrial (LA) area, isovolumic relaxation time, left ventricular inflow deceleration time, E' velocity, and E/E' ratio were evaluated and related to 6-month clinical composite score (CCS) and left ventricular end-systolic volume (LVESV) reduction using Spearman rank-order correlations. Parameters associated with outcomes were analyzed further by discrete categorization. RESULTS: As continuous variables, only E/A ratio and LA area correlated with CCSs (P = 0.017, P = 0.045, respectively) and relative change in LVESV at 6 months (P < 0.0001, P = 0.001, respectively). As discrete variables, E/A ratio and LA area also correlated with CCSs and LVESV. CONCLUSION: Diastolic echo parameters E/A ratio and LA area were associated with clinical and structural outcomes in CRT patients at 6 months.


Asunto(s)
Ecocardiografía/estadística & datos numéricos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/prevención & control , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/prevención & control , Anciano , Comorbilidad , Femenino , Humanos , Masculino , Prevalencia , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad , Estados Unidos/epidemiología
18.
Open Heart ; 10(2)2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37793674

RESUMEN

OBJECTIVE: To determine the diagnostic yield of a 'high' N-terminal pro-brain natriuretic peptide (NT-proBNP) in patients with suspected heart failure (HF) referred from primary to secondary care. METHODS: In this retrospective study, cardiac diagnoses were quantified in consecutive patients with an NT-proBNP>400 ng/L referred from primary care centres to a specialist HF service. RESULTS: Among 654 consecutive patients (age: 78.5±9.72 years; 45.9% men; left ventricular ejection fraction (LVEF): 55.4±12.5% (mean±SD)), the primary diagnoses were: valvular disease (39.4%), HF (29.2%; 13.3% with LVEF<40%) and atrial fibrillation (AF; 17.3%). In terms of primary or secondary diagnoses, 68% of patients had valve disease, 46.9% had AF and 29.2% had HF. A cardiac diagnosis was made in 85.9%. In multivariable analyses, NT-proBNP predicted HF with LVEF<40% (OR: 10.2, 95% CI: 5.63 to 18.3) and HF with any LVEF (OR: 6.13, 95% CI: 3.79 to 9.93). In canonical linear discriminant analyses, NT-proBNP correctly identified 54.5% of patients with HF. The remainder were misclassified as valvular disease, AF or no cardiac diagnosis. CONCLUSION: Among patients with an NT-proBNP>400 ng/L referred through a primary care HF pathway, most patients had valve disease or AF rather than HF. NT-proBNP cannot discriminate among HF, valve disease and AF. On this basis, NT-proBNP may be best employed in detecting cardiac disease in general rather than HF per se.


Asunto(s)
Insuficiencia Cardíaca , Enfermedades de las Válvulas Cardíacas , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Volumen Sistólico , Estudios Retrospectivos , Función Ventricular Izquierda , Derivación y Consulta
19.
Eur J Heart Fail ; 25(2): 274-283, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36404397

RESUMEN

AIMS: Excessive prolongation of PR interval impairs coupling of atrio-ventricular (AV) contraction, which reduces left ventricular pre-load and stroke volume, and worsens symptoms. His bundle pacing allows AV delay shortening while maintaining normal ventricular activation. HOPE-HF evaluated whether AV optimized His pacing is preferable to no-pacing, in a double-blind cross-over fashion, in patients with heart failure, left ventricular ejection fraction (LVEF) ≤40%, PR interval ≥200 ms and either QRS ≤140 ms or right bundle branch block. METHODS AND RESULTS: Patients had atrial and His bundle leads implanted (and an implantable cardioverter-defibrillator lead if clinically indicated) and were randomized to 6 months of pacing and 6 months of no-pacing utilizing a cross-over design. The primary outcome was peak oxygen uptake during symptom-limited exercise. Quality of life, LVEF and patients' holistic symptomatic preference between arms were secondary outcomes. Overall, 167 patients were randomized: 90% men, 69 ± 10 years, QRS duration 124 ± 26 ms, PR interval 249 ± 59 ms, LVEF 33 ± 9%. Neither peak oxygen uptake (+0.25 ml/kg/min, 95% confidence interval [CI] -0.23 to +0.73, p = 0.3) nor LVEF (+0.5%, 95% CI -0.7 to 1.6, p = 0.4) changed with pacing but Minnesota Living with Heart Failure quality of life improved significantly (-3.7, 95% CI -7.1 to -0.3, p = 0.03). Seventy-six percent of patients preferred His bundle pacing-on and 24% pacing-off (p < 0.0001). CONCLUSION: His bundle pacing did not increase peak oxygen uptake but, under double-blind conditions, significantly improved quality of life and was symptomatically preferred by the clear majority of patients. Ventricular pacing delivered via the His bundle did not adversely impact ventricular function during the 6 months.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Humanos , Femenino , Fascículo Atrioventricular , Estudios Cruzados , Volumen Sistólico , Calidad de Vida , Tolerancia al Ejercicio , Función Ventricular Izquierda , Oxígeno , Resultado del Tratamiento , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos
20.
Pacing Clin Electrophysiol ; 35(8): 948-60, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22747698

RESUMEN

BACKGROUND: Hemodynamic optimization of cardiac resynchronization therapy (CRT) can be achieved reproducibly and--with bulky, nonimplantable equipment--noninvasively. We explored whether a simple photoplethysmogram signal might be used instead. METHOD: Twenty patients (age 65 ± 12) with CRT underwent automatic atrioventricular (AV) delay optimization, using a multiple-transitions protocol, at two atrially paced heart rates: just above sinus rate ("slow ApVp," 77 ± 11 beats per minute [bpm]) and 100 bpm ("fast ApVp"). We then retested to assess short-term reproducibility. RESULTS: All 80 optimizations identified an optimum (correctly oriented parabola). At 100 bpm, the simple photoplethysmogram had wider scatter between repeat optimizations than did Finometer: standard deviation of difference (SDD) 22 ms versus 14 ms, respectively, P = 0.028. The simple photoplethysmogram improved in reproducibility when slope (instead of peak) of its signal was used for optimization, becoming as reproducible as Finometer (SDD 14 ms vs 14 ms, P = 0.50). At slow heart rate, reproducibility of simple photoplethysmogram-based optimization worsened from 14 to 22 ms (P = 0.028), and Finometer-based optimization from 14 to 26 ms (P = 0.005). Increasing the number of replicates averaged improved reproducibility. For example, SDD of simple photoplethysmogram optimization (using peak) fell from 62 ms with two replicates to 22 ms with eight replicates (P < 0.0001). At 100 bpm, the eight-replicate protocol takes ∼12 minutes. CONCLUSIONS: A 12-minute protocol of simple photoplethysmographic AV optimization can be processed fully automatically. Blinded test-retest reproducibility of the optimum AV is good and improves with more replicates. If benefits to some patients are not to be neutralized by harm to others, endpoint studies should first test check narrowness of "within-patient error bars."


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Fotopletismografía/métodos , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Oximetría/instrumentación , Oximetría/métodos , Fotopletismografía/instrumentación , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA