Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Crit Care Med ; 51(1): 117-126, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36519985

RESUMEN

OBJECTIVES: Evaluate associations between ultrasound measures and difficult laryngoscopy. DATA SOURCES: MEDLINE, Embase, Google Scholar, Web of Science, and the Cochrane Library were searched using MeSH terms and keywords. STUDY SELECTION: Studies published in English describing the use of airway ultrasound for identifying difficult laryngoscopy, with sufficient data to calculate sensitivity and specificity using 2 × 2 tables. DATA EXTRACTION: We assigned the described indices of airway dimension to one of three domains based on methodology characteristics: anterior tissue thickness domain, anatomical position domain, and oral space domain. We then performed a bivariate random-effects meta-analysis, deriving pooled sensitivity, specificity, diagnostic odds ratio, positive likelihood ratio, and negative likelihood ratio estimates. We assessed risks of bias using Quality Assessment of Diagnostic Accuracy Studies-2 analysis. DATA SYNTHESIS: Thirty-three studies evaluating 27 unique indices were included in the meta-analysis. The ultrasound protocols of the included studies were heterogeneous. Anterior tissue thickness demonstrated a pooled sensitivity of 76% (95% CI, 71-81%), specificity of 77% (95% CI, 72-81%), and an area under the receiver operating characteristic curve (AUROC) of 0.83 (95% CI, 0.80-0.86). Anatomical position demonstrated a pooled sensitivity of 74% (95% CI, 61-84%), specificity of 86% (95% CI, 78-91%), and an AUROC of 0.87 (95% CI, 0.84-0.90). Oral space demonstrated a pooled sensitivity of 53% (95% CI, 0.36-0.69), specificity of 77% (95% CI, 0.67-0.85), and an AUROC of 0.73 (95% CI, 0.69-0.77). CONCLUSIONS: Airway ultrasound metrics associate with difficult laryngoscopy in three domains: anterior tissue thickness, anatomic position, and oral space. An assessment instrument combining clinical and ultrasound assessments may be an accurate screening tool for difficult laryngoscopy.


Asunto(s)
Laringoscopía , Laringoscopía/métodos , Sensibilidad y Especificidad , Ultrasonografía , Curva ROC
2.
Pediatr Crit Care Med ; 24(11): e568-e572, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37318261

RESUMEN

Point-of-care ultrasound (POCUS) is an expanding noninvasive diagnostic modality used for the management of patients in multiple intensive care and pediatric specialties. POCUS is used to assess cardiac activity and pathology, pulmonary disease, intravascular volume status, intra-abdominal processes, procedural guidance including vascular access, lumbar puncture, thoracentesis, paracentesis, and pericardiocentesis. POCUS has also been used to determine anterograde flow following circulatory arrest when organ donation after circulatory death is being considered. Published guidelines exist from multiple medical societies including the recent guidelines for the use of POCUS in neonatology for diagnostic and procedural purposes.


Asunto(s)
Paro Cardíaco , Sistemas de Atención de Punto , Humanos , Niño , Ultrasonografía , Pruebas en el Punto de Atención , Corazón , Paro Cardíaco/diagnóstico por imagen , Paro Cardíaco/terapia
3.
Pediatr Crit Care Med ; 24(11): e511-e519, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37260313

RESUMEN

Point-of-care ultrasound (POCUS) is increasingly accepted in pediatric critical care medicine as a tool for guiding the evaluation and treatment of patients. POCUS is a complex skill that requires user competency to ensure accuracy, reliability, and patient safety. A robust competency-based medical education (CBME) program ensures user competency and mitigates patient safety concerns. A programmatic assessment model provides a longitudinal, holistic, and multimodal approach to teaching, assessing, and evaluating learners. The authors propose a fit-for-purpose and modifiable CBME model that is adaptable for different institutions' resources and needs for any intended competency level. This educational model drives and supports learning, ensures competency attainment, and creates a clear pathway for POCUS education while enhancing patient care and safety.


Asunto(s)
Educación Basada en Competencias , Sistemas de Atención de Punto , Humanos , Niño , Reproducibilidad de los Resultados , Ultrasonografía , Cuidados Críticos
4.
Pediatr Res ; 91(5): 1057-1063, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34075190

RESUMEN

BACKGROUND: Difficulty in obtaining peripheral vascular access is a common problem in patients admitted to the pediatric intensive care unit (PICU). The use of ultrasound guidance can improve the overall success in obtaining vascular access. This study evaluated the success and longevity of PIV placement by nurses pre- and post-implementation of an USGPIV curriculum. METHODS: PICU nurses participated in a prospective quality improvement study. Each participating nurse attempted 10 PIVs by using landmark (LM) methods. The same nurses then received individual instruction in an USGPIV placement curriculum. Following the educational intervention, each nurse attempted 10 USGPIVs. RESULTS: A total of 150 LM PIVs and 143 USGPIVs were attempted. The first stick success in the post-intervention (USGPIV) group was 85.9% compared to 47.3% in the pre-intervention (LM) group (p < 0.001). Overall success was also superior in the USGPIV group (94.3 versus 57.3%, respectively; p < 0.001). PIVs placed by US lasted longer with a median survival time of 4 ± 3.84 days versus 3 ± 3.51 days for LM PIVs (p < 0.050, log-rank test). CONCLUSIONS: Successful implementation of a standardized curriculum for USGPIV placement for PICU nurses improves first stick, overall success, and longevity of PIV catheter placement. IMPACT: An ultrasound-guided IV curriculum can be successfully implemented resulting in increased first stick success and increased longevity. Registered nurses can be trained in placement of ultrasound-guided IV placement. This study provides a training curriculum for ultrasound-guided IV placement that can be applied to other settings or institutions.


Asunto(s)
Cateterismo Periférico , Ultrasonografía Intervencional , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Catéteres , Niño , Enfermedad Crítica , Humanos , Estudios Prospectivos , Ultrasonografía Intervencional/métodos
5.
J Ultrasound Med ; 41(8): 1873-1888, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34837415

RESUMEN

Laryngeal ultrasound (US) is becoming widely accepted for assessing true vocal fold immobility (TVFI), a potential complication of laryngeal and thyroid surgery. The objective of this project is to perform a systematic review and meta-analysis of pooled evidence surrounding laryngeal US as a modality for diagnosing TVFI in adults at risk for the condition in comparison to laryngoscopy as a gold standard. Medical subject heading terms were used to search MEDLINE, Embase, Google Scholar, Web of Science, and the Cochrane Library for relevant citations from January 1, 2000, to June 30, 2020. Studies were included if they involved patients 16 years and older, where laryngeal US was compared to laryngoscopy for TVFI. Studies were excluded if there were insufficient data to compute a sensitivity/specificity table after attempting to contact the authors. Case reports, and case series were also excluded. The initial search returned 1357 citations. Of these, 109 were selected for review utilizing the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Thirty citations describing 6033 patients were included in the final meta-analysis. A bivariate random effects meta-analysis was performed, revealing a pooled sensitivity for laryngeal US of 0.95 (95% confidence interval [CI] 0.88-0.98), a specificity of 0.99 (95% CI 0.97-0.99), and a diagnostic odds ratio of 1328.2 (95% CI 294.0-5996.5). The area under the curve of the hierarchical summary receiver operating characteristic curve was 0.99 (95% CI 0.98-1.00). Laryngeal US demonstrates high sensitivity and specificity for detecting VFI in the hands of clinicians directly providing care to patients.


Asunto(s)
Laringoscopía , Pliegues Vocales , Adulto , Humanos , Sensibilidad y Especificidad , Ultrasonografía , Pliegues Vocales/diagnóstico por imagen
6.
Pediatr Crit Care Med ; 22(4): e253-e258, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33060421

RESUMEN

Point-of-care ultrasound (POCUS) use is rapidly expanding as a practice in adult and pediatric critical care environments. In January 2020, the Joint Commission endorsed a statement from the Emergency Care Research Institute citing point-of-care ultrasound as a potential hazard to patients for reasons related to training and skill verification, oversight of use, and recordkeeping and accountability mechanisms for clinical use; however, no evidence was presented to support these concerns. Existing data on point-of-care ultrasound practices in pediatric critical care settings verify that point-of-care ultrasound use continues to increase, and contrary to the concerns raised, resources are becoming increasingly available for point-of-care ultrasound use. Many institutions have recognized a successful approach to addressing these concerns that can be achieved through multispecialty collaborations.


Asunto(s)
Cuidados Críticos , Sistemas de Atención de Punto , Adulto , Niño , Humanos , Pruebas en el Punto de Atención , Ultrasonografía
7.
Pediatr Crit Care Med ; 22(10): e532-e539, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33833204

RESUMEN

OBJECTIVES: Laryngeal ultrasound is a nonirradiating, noninvasive method for assessing the upper airway in children. This systematic review and meta-analysis examine available evidence for accuracy of laryngeal ultrasound in diagnosing vocal cord immobility in infants and children after surgery and trauma affecting the vocal cords. DESIGN: Medical subject heading terms were used to search MEDLINE, Embase, Google Scholar, Web of Science, and the Cochrane Library for relevant citations. Publications from January 1, 2000, to June 30, 2020 were included in the search strategy. Study inclusion criteria consisted of randomized control trials and nonrandomized retrospective or prospective observational studies where vocal cord motion was evaluated by laryngeal ultrasound and compared with a reference test. Studies were excluded if there was insufficient data to compute a sensitivity/specificity table. Case reports, case series less than 10, and manuscripts not published in English were also excluded. PATIENTS: Studies which included subjects younger than or equal to 18 years were considered for full article review. SETTINGS: No restrictions on study settings were imposed in this systematic review. MEASUREMENTS AND MAIN RESULTS: The initial search returned 1,357 citations. After de-duplication, abstract, and full review, eight citations were included in the final meta-analysis. A bivariate random-effects meta-analysis was performed, which revealed a pooled sensitivity for laryngeal ultrasound in detecting vocal cord immobility of 91% (95% CI, 83-95%), specificity of 97% (95% CI, 82-100%), diagnostic odds ratio 333.56 (95% CI, 34.00-3,248.71), positive likelihood ratio 31.58 (95% CI, 4.50-222.05), and negative likelihood ratio 0.09 (95% CI, 0.05-0.19). CONCLUSIONS: Laryngeal ultrasound demonstrates high sensitivity and specificity for detecting vocal cord motion in children in a wide range of clinical settings. Laryngeal ultrasound offers a low-risk imaging option for assessing vocal cord function in children compared with the current gold standard of laryngoscopy.


Asunto(s)
Laringe , Pliegues Vocales , Niño , Humanos , Lactante , Laringoscopía , Laringe/diagnóstico por imagen , Estudios Observacionales como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Ultrasonografía , Pliegues Vocales/diagnóstico por imagen
8.
Pediatr Crit Care Med ; 21(9): e858-e868, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32796395

RESUMEN

OBJECTIVES: Ultrasound measured optic nerve sheath diameter is a noninvasive, nonirradiating tool for estimating intracranial hypertension. The objective of this systematic review and meta-analysis is summarization of the current evidence for accuracy of ultrasound measured optic nerve sheath diameter in detecting intracranial hypertension in pediatric patients. DATA SOURCES: Medical subject heading terms were used to search MEDLINE, Embase, Google Scholar, Web of Science, and the Cochrane Library for relevant citations. Publications from January 1, 2000, to June 30, 2019, were included in the search strategy. STUDY SELECTION: Studies were included if they involved patients less than 18 years, where ultrasound measured optic nerve sheath diameter was compared to conventional, nonophthalmic tests for intracranial hypertension. Studies were excluded if there was insufficient data to compute a sensitivity/specificity table. Case reports, case series, and manuscripts not published in English were also excluded. DATA EXTRACTION: The initial search returned 573 citations. Of these, 57 were selected for review. DATA SYNTHESIS: Eleven citations were included in the final meta-analysis. A bivariate random-effects meta-analysis was performed, which revealed a pooled sensitivity for ultrasound measured optic nerve sheath diameter of 93% (95% CI, 74-99%), a specificity of 74% (95% CI, 52-88%), and a diagnostic odds ratio of 39.00 (95% CI, 4.16-365.32). The area under the curve of the hierarchical summary receiver operating characteristic curve was 0.90 (95% CI, 0.87-0.93). Subgroup analyses of the test's performance evaluating new-onset intracranial hypertension and in comparison to invasively measured intracranial pressure were performed. The test performance in these instances was similar to findings in the primary analysis. CONCLUSIONS: We are unable to identify a threshold value in ultrasound measured optic nerve sheath diameter for the determination of intracranial hypertension in children. Even though the ultrasound measured optic nerve sheath diameter measurement is highly sensitive to the presence of increased intracranial pressure, the test has only moderate specificity. Therefore, other confirmatory methods and further investigation is necessary in the clinical care of children. The technique is likely not sufficiently precise for clinical use in the absence of other confirmatory methods, and further investigation is necessary to determine clinical protocols for its use in children.


Asunto(s)
Hipertensión Intracraneal , Nervio Óptico , Niño , Humanos , Hipertensión Intracraneal/diagnóstico por imagen , Hipertensión Intracraneal/etiología , Presión Intracraneal , Nervio Óptico/diagnóstico por imagen , Sensibilidad y Especificidad , Ultrasonografía
10.
Crit Care Med ; 51(6): e132, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37199556
12.
Pediatr Crit Care Med ; 19(11): e561-e568, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30113518

RESUMEN

OBJECTIVES: To assess current diagnostic bedside ultrasound program core element (training, credentialing, image storage, documentation, and quality assurance) implementation across pediatric critical care medicine divisions in the United States. DESIGN: Cross-sectional questionnaire-based needs assessment survey. SETTING: Pediatric critical care medicine divisions with an Accreditation Council of Graduate Medical Education-accredited fellowship. RESPONDENTS: Divisional leaders in education and/or bedside ultrasound training. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Fifty-five of 67 pediatric critical care medicine divisions (82%) with an Accreditation Council of Graduate Medical Education-accredited fellowship provided responses. Overall, 63% of responding divisions (34/54) were clinically performing diagnostic bedside ultrasound studies with no difference between divisions with large versus small units. Diagnostic bedside ultrasound training is available for pediatric critical care medicine fellows within 67% of divisions (35/52) with no difference in availability between divisions with large versus small units. Other core elements were present in less than 25% of all divisions performing clinical studies, with a statistically significant increase in credentialing and documentation among divisions with large units (p = 0.048 and 0.01, respectively). All core elements were perceived to have not only high impact in program development but also high effort in implementation. Assuming that all structural elements could be effectively implemented within their division, 83% of respondents (43/52) agreed that diagnostic bedside ultrasound should be a core curricular component of fellowship education. CONCLUSIONS: Diagnostic bedside ultrasound is increasingly prevalent in training and clinical use across the pediatric critical care medicine landscape despite frequently absent core programmatic infrastructural elements. These core elements are perceived as important to program development, regardless of division unit size. Shared standardized resources may assist in reducing the effort in core element implementation and allow us to measure important educational and clinical outcomes.


Asunto(s)
Curriculum , Educación de Postgrado en Medicina/estadística & datos numéricos , Pediatría/educación , Sistemas de Atención de Punto/estadística & datos numéricos , Ultrasonografía , Niño , Habilitación Profesional/estadística & datos numéricos , Cuidados Críticos/métodos , Estudios Transversales , Educación de Postgrado en Medicina/métodos , Becas/estadística & datos numéricos , Humanos , Unidades de Cuidado Intensivo Pediátrico/estadística & datos numéricos , Desarrollo de Programa , Encuestas y Cuestionarios
13.
Can J Anaesth ; 65(4): 485-498, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29352416

RESUMEN

Ultrasound has increasingly become a clinical asset in the hands of the anesthesiologist and intensivist who cares for children. Though many applications for ultrasound parallel adult modalities, children as always are not simply small adults and benefit from the application of ultrasound to their management in various ways. Body composition and size are important factors that affect ultrasound performance in the child, as are the pathologies that may uniquely afflict children and aspects of procedures unique to this patient population. Ultrasound simplifies vascular access and other procedures by visualizing structures smaller than those in adults. Maturation of the thoracic cage presents challenges for the clinician performing pulmonary ultrasound though a greater proportion of the thorax can be seen. Moreover, ultrasound may provide unique solutions to sizing the airway and assessing it for cricothyroidotomy. Though cardiac ultrasound and neurosonology have historically been performed by well-developed diagnostic imaging services, emerging literature stresses the utility of clinician ultrasound in screening for pathology and providing serial observations for monitoring clinical status. Use of ultrasound is growing in clinical areas where time and diagnostic accuracy are crucial. Implementation of ultrasound at the bedside will require institutional support of education and credentialing. It is only natural that the pediatric anesthesiologist and intensivist will lead the incorporation of ultrasound in the future practice of these specialties.


Asunto(s)
Anestesiología/métodos , Cuidados Críticos/métodos , Sistemas de Atención de Punto , Ultrasonografía/métodos , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Unidades de Cuidado Intensivo Pediátrico , Ultrasonografía/instrumentación
14.
Pediatr Emerg Care ; 33(1): 58-59, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28045844

RESUMEN

Sonographic cardiac standstill during adult cardiac arrest is associated with failure to get return to spontaneous circulation. This report documents 3 children whose cardiac function returned after standstill with extracorporeal membranous oxygenation. Sonographic cardiac standstill may not predict cardiac death in children.


Asunto(s)
Paro Cardíaco/diagnóstico por imagen , Paro Cardíaco/fisiopatología , Niño , Ecocardiografía , Oxigenación por Membrana Extracorpórea , Resultado Fatal , Femenino , Paro Cardíaco/terapia , Humanos , Lactante , Recién Nacido , Masculino , Recuperación de la Función
15.
Crit Care Med ; 44(6): 1206-27, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27182849

RESUMEN

OBJECTIVE: To establish evidence-based guidelines for the use of bedside cardiac ultrasound, echocardiography, in the ICU and equivalent care sites. METHODS: Grading of Recommendations, Assessment, Development and Evaluation system was used to rank the "levels" of quality of evidence into high (A), moderate (B), or low (C) and to determine the "strength" of recommendations as either strong (strength class 1) or conditional/weak (strength class 2), thus generating six "grades" of recommendations (1A-1B-1C-2A-2B-2C). Grading of Recommendations, Assessment, Development and Evaluation was used for all questions with clinically relevant outcomes. RAND Appropriateness Method, incorporating the modified Delphi technique, was used in formulating recommendations related to terminology or definitions or in those based purely on expert consensus. The process was conducted by teleconference and electronic-based discussion, following clear rules for establishing consensus and agreement/disagreement. Individual panel members provided full disclosure and were judged to be free of any commercial bias. RESULTS: Forty-five statements were considered. Among these statements, six did not achieve agreement based on RAND appropriateness method rules (majority of at least 70%). Fifteen statements were approved as conditional recommendations (strength class 2). The rest (24 statements) were approved as strong recommendations (strength class 1). Each recommendation was also linked to its level of quality of evidence and the required level of echo expertise of the intensivist. Key recommendations, listed by category, included the use of cardiac ultrasonography to assess preload responsiveness in mechanically ventilated (1B) patients, left ventricular (LV) systolic (1C) and diastolic (2C) function, acute cor pulmonale (ACP) (1C), pulmonary hypertension (1B), symptomatic pulmonary embolism (PE) (1C), right ventricular (RV) infarct (1C), the efficacy of fluid resuscitation (1C) and inotropic therapy (2C), presence of RV dysfunction (2C) in septic shock, the reason for cardiac arrest to assist in cardiopulmonary resuscitation (1B-2C depending on rhythm), status in acute coronary syndromes (ACS) (1C), the presence of pericardial effusion (1C), cardiac tamponade (1B), valvular dysfunction (1C), endocarditis in native (2C) or mechanical valves (1B), great vessel disease and injury (2C), penetrating chest trauma (1C) and for use of contrast (1B-2C depending on indication). Finally, several recommendations were made regarding the use of bedside cardiac ultrasound in pediatric patients ranging from 1B for preload responsiveness to no recommendation for RV dysfunction. CONCLUSIONS: There was strong agreement among a large cohort of international experts regarding several class 1 recommendations for the use of bedside cardiac ultrasound, echocardiography, in the ICU. Evidence-based recommendations regarding the appropriate use of this technology are a step toward improving patient outcomes in relevant patients and guiding appropriate integration of ultrasound into critical care practice.


Asunto(s)
Ecocardiografía , Cardiopatías/diagnóstico por imagen , Unidades de Cuidados Intensivos , Sistemas de Atención de Punto , Síndrome Coronario Agudo/diagnóstico por imagen , Adolescente , Adulto , Apoyo Vital Cardíaco Avanzado , Enfermedades de la Aorta/diagnóstico por imagen , Taponamiento Cardíaco/diagnóstico por imagen , Niño , Preescolar , Enfermedad Crítica , Fluidoterapia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Derrame Pericárdico/diagnóstico por imagen , Choque Séptico/diagnóstico por imagen , Traumatismos Torácicos/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Adulto Joven
16.
Pediatr Crit Care Med ; 22(5): e331-e332, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33953138
17.
Pediatr Crit Care Med ; 22(10): 930-932, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34605788
19.
Pediatr Crit Care Med ; 17(5): 383-90, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26963758

RESUMEN

OBJECTIVES: In the progression of severe sepsis, sepsis-induced myocardial dysfunction contributes to severity of illness and ultimate mortality. Identification of sepsis-induced myocardial dysfunction causing depressed cardiac function during critical illness has implications for ongoing patient management. However, assessing pediatric cardiac function traditionally relies on echocardiographic qualitative assessment and measurement of left ventricular ejection fraction or fractional shortening. These metrics are often insensitive for detecting early or regional myocardial dysfunction. Strain echocardiography is a contemporary echocardiographic modality that may be more sensitive to perturbations in cardiac function. This investigation hypothesizes that strain echocardiography metrics correlate with severity of illness in pediatric sepsis despite normal fractional shortening. DESIGN: Single-center retrospective observational study. SETTING: Tertiary 36-bed medical/surgical PICU. PATIENTS: Pediatric patients admitted with sepsis. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Twenty-three children with sepsis received an echocardiogram in the study period. Patients with sepsis demonstrated abnormal peak systolic longitudinal strain for age (mean = -0.13 ± 0.07; p < 0.01) and low normal peak systolic circumferential strain (mean = -0.17 ± 0.14; p = 0.02) compared with internal controls as well as previously published normal values. Depressed strain was demonstrated in the septic patients despite having normal fractional shortening (mean = 0.41; 95% CI, 0.38-0.43). On initial echocardiographic imaging, worsening peak systolic longitudinal strain was associated with increasing lactate (p = 0.04). CONCLUSIONS: Pediatric patients with sepsis demonstrate evidence of depressed strain echocardiography parameters not shown by fractional shortening that correlate with clinical indices of sepsis severity. Whether strain echocardiography could eventually assist in grading pediatric sepsis severity and affect management is an area for potential future investigation.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Ecocardiografía/métodos , Sepsis/complicaciones , Índice de Severidad de la Enfermedad , Adolescente , Cardiomiopatías/etiología , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Variaciones Dependientes del Observador , Estudios Retrospectivos
20.
Pediatr Crit Care Med ; 17(12): 1124-1130, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27632058

RESUMEN

OBJECTIVE: Peripheral arterial catheterization is a common invasive procedure performed in critically ill children. However, the benefits of using ultrasound guidance for this procedure in critically ill children, especially when used by inexperienced trainees, are unclear. Our aims were to evaluate whether the use of ultrasound guidance for the placement of radial arterial catheters reduced time and improved success when compared with the palpation method and also to determine patient and trainee variables that influence procedure outcomes. Finally, we evaluated whether adoption of ultrasound guidance among trainees comes at the expense of learning landmark-based methods. DESIGN: Prospective observational cohort. SETTING: University affiliated PICU. PATIENTS: A total of 208 procedures performed by 45 trainees in 192 unique patients (1 mo to 20 yr old) were observed. INTERVENTION: Implementation of ultrasound curriculum. MEASUREMENTS AND MAIN RESULTS: The main outcome measures were time and number of attempts required for the procedure. Compared with palpation method, ultrasound guidance was associated with reduced procedure time (8.1 ± 5.2 min compared with 16.5 ± 8.8 min; p < 0.001), reduced number of attempts (3.1 ± 2.6 attempts compared with 6.9 ± 4.2 attempts; p < 0.001), and improved first attempt success rate (28% compared with 11%; p = 0.001) even after adjusting for key confounders in multivariate random effects models. The factors most likely to interfere with peripheral arterial catheterization are patient age, patient systolic blood pressure, patient body mass index, degree of fluid overload, and trainee months in fellowship. The use of ultrasound guidance mitigates the influence of each of these factors. We found no evidence that the adoption of ultrasound guidance by trainees is associated with reduced proficiency in landmark-based methods. CONCLUSIONS: The use of ultrasound guidance by trainees for radial artery catheterization in critically ill children is associated with improved outcomes compared with the palpation method.


Asunto(s)
Cateterismo Periférico/métodos , Cuidados Críticos/métodos , Educación de Postgrado en Medicina , Pediatría/educación , Ultrasonografía Intervencional , Adolescente , Boston , Niño , Preescolar , Competencia Clínica , Enfermedad Crítica , Femenino , Humanos , Lactante , Masculino , Evaluación de Resultado en la Atención de Salud , Estudios Prospectivos , Método Simple Ciego , Factores de Tiempo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA