RESUMEN
Aims: We aimed to identify patients who would benefit from basal insulin-supported oral therapy (BOT) with a glinide and an α-glucosidase inhibitor (a fixed-dose combination tablet of mitiglinide 10 mg and voglibose 0.2 mg) in Japanese type 2 diabetic patients. Methods: Patients who were hospitalized to improve hyperglycemia received basal-bolus insulin therapy. After the reduction of glucose toxicity, a 75 g oral glucose tolerance test and a glucagon test were performed. Thereafter, the basal-bolus insulin therapy was switched to BOT with mitiglinide, followed by further addition of voglibose. Interstitial glucose levels were continuously monitored throughout the study period. Diurnal glucose profile was recorded and analyzed. Patients were divided into two groups according to whether their percentage of time in range (TIR, 70-180 mg/dL) under BOT with mitiglinide/voglibose was higher than 70% or not, and the differences in clinical characteristics between the groups were analyzed. Results: Twenty patients were enrolled, and 19 of them completed the study. BOT with mitiglinide/voglibose achieved ≥ 70% of TIR in thirteen patients. The area under the curve of serum C-peptide levels during the oral glucose tolerance test was significantly higher in the patients with ≥ 70% of TIR. The daily insulin dosages and blood glucose profiles were comparable between the two groups. Conclusions: The efficacy of BOT with mitiglinide/voglibose depended on residual insulin secretory abilities. This therapy would be a useful therapeutic option for patients with type 2 diabetes.
RESUMEN
AIMS/INTRODUCTION: Diabetic polyneuropathy (DPN) develops in the early stage of diabetes. However, no common diagnostic protocol has yet been established. Here, to verify that the flicker electroretinogram using a hand-held device can detect the early dysfunction of the peripheral nervous system in patients with diabetes, we investigated the correlation between the progression of DPN and neuroretinal dysfunction. MATERIALS AND METHODS: In total, 184 participants with type 1 or 2 diabetes underwent a flicker electroretinogram (ERG) using a hand-held device RETeval™ and nerve conduction study. Participants were also evaluated for intima-media thickness, ankle-brachial index, toe brachial index and brachial-ankle pulse wave velocity. Parameters of the nerve conduction study were used to diagnose the severity according to Baba's classification. A multiple regression analysis was used to examine the associations of ERG parameters with the severity of DPN categorized by Baba's classification. Diagnostic properties of the device in DPN were evaluated using a receiver operating characteristic curve. RESULTS: A multiple regression model to predict the severity of DPN was generated using ERG. In the model, moderate-to-severe DPN was effectively diagnosed (area under the receiver operating characteristic curve 0.692, sensitivity 56.5%, specificity 78.3%, positive predictive value 70.6%, negative predictive value 66.1%, positive likelihood ratio 2.60, negative likelihood ratio 0.56). In the patients without diabetic retinopathy, the implicit time and amplitude in ERG significantly correlated with the parameters of the nerve conduction study, brachial-ankle pulse wave velocity and intima-media thickness. CONCLUSIONS: Electroretinogram parameters obtained by the hand-held device successfully predict the severity of DPN. The device might be useful to evaluate DPN.
Asunto(s)
Aterosclerosis/fisiopatología , Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 2/fisiopatología , Neuropatías Diabéticas/diagnóstico , Retinopatía Diabética/diagnóstico , Electrorretinografía/instrumentación , Anciano , Índice Tobillo Braquial , Aterosclerosis/complicaciones , Grosor Intima-Media Carotídeo , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 2/complicaciones , Neuropatías Diabéticas/etiología , Retinopatía Diabética/etiología , Electrorretinografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Conducción Nerviosa/fisiología , Nervios Periféricos/fisiopatología , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso , Curva ROC , Índice de Severidad de la EnfermedadRESUMEN
AIMS/INTRODUCTION: Although nerve conduction study (NCS) using a standard electromyography system (EMGS) is considered to be the gold standard in evaluating diabetic polyneuropathy, this examination requires expensive equipment and well-trained technicians. We aimed to validate a point-of-care device, NC-stat/DPNCheck™, that has been developed for widespread use of NCS in diabetic polyneuropathy. MATERIALS AND METHODS: Diabetes patients underwent two kinds of NCS: DPNCheck™ and electromyography system. Inter-/intrarater reliability of DPNCheck™ were also determined by the intraclass correlation coefficient. RESULTS: A total of 57 patients were evaluated. The parameters of NCS between the two methods correlated well (r = 0.7734 for the sural nerve conduction velocity, r = 0.6155 for the amplitude of sural nerve action potential). The intraclass correlation coefficients were excellent (intrarater: the velocity 0.767, the amplitude 0.811; interrater: the velocity 0.974, the amplitude 0.834). CONCLUSIONS: The point-of-care device has excellent reproducibility and good agreement with standard electromyography system. The device might be useful to evaluate diabetic polyneuropathy.