Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Materials (Basel) ; 10(1)2017 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-28772414

RESUMEN

Magnesium alloys are promising candidates for biodegradable medical implants which reduce the necessity of second surgery to remove the implants. Yttrium in solid solution is an attractive alloying element because it improves mechanical properties and exhibits suitable corrosion properties. Silver was shown to have an antibacterial effect and can also enhance the mechanical properties of magnesium alloys. Measurements of microhardness and electrical resistivity were used to study the response of Mg-4Y and Mg-4Y-1Ag alloys to isochronal or isothermal heat treatments. Hardening response and electrical resistivity annealing curves in these alloys were compared in order to investigate the effect of silver addition. Procedures for solid solution annealing and artificial aging of the Mg-4Y-1Ag alloy were developed. The corrosion rate of the as-cast and heat-treated Mg-4Y-1Ag alloy was measured by the mass loss method. It was found out that solid solution heat treatment, as well artificial aging to peak hardness, lead to substantial improvement in the corrosion properties of the Mg-4Y-1Ag alloy.

2.
PLoS One ; 11(7): e0159879, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27459513

RESUMEN

This study investigated the effect of biodegradable Mg and Mg alloys on selected properties of MC3T3-E1 cells elicited by direct cell/material interaction. The chemical composition and morphology of the surface of Mg and Mg based alloys (Mg2Ag and Mg10Gd) were analysed by scanning electron microscopy (SEM) and EDX, following corrosion in cell culture medium for 1, 2, 3 and 8 days. The most pronounced difference in surface morphology, namely crystal formation, was observed when Pure Mg and Mg2Ag were immersed in cell medium for 8 days, and was associated with an increase in atomic % of oxygen and a decrease of surface calcium and phosphorous. Crystal formation on the surface of Mg10Gd was, in contrast, negligible at all time points. Time-dependent changes in oxygen, calcium and phosphorous surface content were furthermore not observed for Mg10Gd. MC3T3-E1 cell viability was reduced by culture on the surfaces of corroded Mg, Mg2Ag and Mg10Gd in a corrosion time-independent manner. Cells did not survive when cultured on 3 day pre-corroded Pure Mg and Mg2Ag, indicating crystal formation to be particular detrimental in this regard. Cell viability was not affected when cells were cultured on non-corroded Mg and Mg alloys for up to 12 days. These results suggest that corrosion associated changes in surface morphology and chemical composition significantly hamper cell viability and, thus, that non-corroded surfaces are more conducive to cell survival. An analysis of the differentiation potential of MC3T3-E1 cells cultured on non-corroded samples based on measurement of Collagen I and Runx2 expression, revealed a down-regulation of these markers within the first 6 days following cell seeding on all samples, despite persistent survival and proliferation. Cells cultured on Mg10Gd, however, exhibited a pronounced upregulation of collagen I and Runx2 between days 8 and 12, indicating an enhancement of osteointegration by this alloy that could be valuable for in vivo orthopedic applications.


Asunto(s)
Implantes Absorbibles/efectos adversos , Aleaciones/efectos adversos , Diferenciación Celular , Corrosión , Magnesio/química , Osteoblastos/efectos de los fármacos , Aleaciones/química , Animales , Línea Celular , Supervivencia Celular , Colágeno/metabolismo , Subunidad alfa 1 del Factor de Unión al Sitio Principal/metabolismo , Gadolinio/química , Ratones , Osteoblastos/metabolismo , Osteoblastos/ultraestructura , Plata/química
3.
Mater Sci Eng C Mater Biol Appl ; 61: 865-74, 2016 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-26838918

RESUMEN

Biodegradable materials are under investigation due to their promising properties for biomedical applications as implant material. In the present study, two binary magnesium (Mg) alloys (Mg2Ag and Mg10Gd) and pure Mg (99.99%) were used in order to compare the degradation performance of the materials in in vitro to in vivo conditions. In vitro analysis of cell distribution and viability was performed on discs of pure Mg, Mg2Ag and Mg10Gd. The results verified viable pre-osteoblast cells on all three alloys and no obvious toxic effect within the first two weeks. The degradation rates in in vitro and in vivo conditions (Sprague-Dawley® rats) showed that the degradation rates differ especially in the 1st week of the experiments. While in vitro Mg2Ag displayed the fastest degradation rate, in vivo, Mg10Gd revealed the highest degradation rate. After four weeks of in vitro immersion tests, the degradation rate of Mg2Ag was significantly reduced and approached the values of pure Mg and Mg10Gd. Interestingly, after 4 weeks the estimated in vitro degradation rates approximate in vivo values. Our systematic experiment indicates that a correlation between in vitro and in vivo observations still has some limitations that have to be considered in order to perform representative in vitro experiments that display the in vivo situation.


Asunto(s)
Aleaciones/química , Materiales Biocompatibles/química , Magnesio/química , Aleaciones/farmacología , Animales , Materiales Biocompatibles/farmacología , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Magnesio/farmacología , Masculino , Microscopía Electrónica de Rastreo , Microscopía Fluorescente , Prótesis e Implantes , Ratas , Ratas Sprague-Dawley , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA