1.
N Engl J Med ; 388(20): 1833-1842, 2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-36876753

RESUMEN

BACKGROUND: Severe tricuspid regurgitation is a debilitating condition that is associated with substantial morbidity and often with poor quality of life. Decreasing tricuspid regurgitation may reduce symptoms and improve clinical outcomes in patients with this disease. METHODS: We conducted a prospective randomized trial of percutaneous tricuspid transcatheter edge-to-edge repair (TEER) for severe tricuspid regurgitation. Patients with symptomatic severe tricuspid regurgitation were enrolled at 65 centers in the United States, Canada, and Europe and were randomly assigned in a 1:1 ratio to receive either TEER or medical therapy (control). The primary end point was a hierarchical composite that included death from any cause or tricuspid-valve surgery; hospitalization for heart failure; and an improvement in quality of life as measured with the Kansas City Cardiomyopathy Questionnaire (KCCQ), with an improvement defined as an increase of at least 15 points in the KCCQ score (range, 0 to 100, with higher scores indicating better quality of life) at the 1-year follow-up. The severity of tricuspid regurgitation and safety were also assessed. RESULTS: A total of 350 patients were enrolled; 175 were assigned to each group. The mean age of the patients was 78 years, and 54.9% were women. The results for the primary end point favored the TEER group (win ratio, 1.48; 95% confidence interval, 1.06 to 2.13; P = 0.02). The incidence of death or tricuspid-valve surgery and the rate of hospitalization for heart failure did not appear to differ between the groups. The KCCQ quality-of-life score changed by a mean (±SD) of 12.3±1.8 points in the TEER group, as compared with 0.6±1.8 points in the control group (P<0.001). At 30 days, 87.0% of the patients in the TEER group and 4.8% of those in the control group had tricuspid regurgitation of no greater than moderate severity (P<0.001). TEER was found to be safe; 98.3% of the patients who underwent the procedure were free from major adverse events at 30 days. CONCLUSIONS: Tricuspid TEER was safe for patients with severe tricuspid regurgitation, reduced the severity of tricuspid regurgitation, and was associated with an improvement in quality of life. (Funded by Abbott; TRILUMINATE Pivotal ClinicalTrials.gov number, NCT03904147.).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Femenino , Humanos , Masculino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/cirugía
2.
J Vasc Surg ; 79(5): 1170-1178.e10, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38244643

RESUMEN

OBJECTIVE: Patients with peripheral artery disease (PAD) and end-stage kidney disease are a high-risk population, and concomitant atherosclerosis in coronary arteries (CAD) or cerebral arteries (CVD) is common. The aim of the study was to assess long-term outcomes of PAD and the impact of coexistent CAD and CVD on outcomes. METHODS: The United States Renal Data System was used to identify patients with PAD within 6 months of incident dialysis. Four groups were formed: PAD alone, PAD with CAD, PAD with CVD, and PAD with CAD and CVD. PAD-specific outcomes (chronic limb-threatening ischemia, major amputation, percutaneous/surgical revascularization, and their composite, defined as major adverse limb events [MALE]) as well as all-cause mortality, myocardial infarction, and stroke were studied. RESULTS: The study included 106,567 patients (mean age, 71.2 years; 40.8% female) with a median follow-up of 546 days (interquartile range, 214-1096 days). Most patients had PAD and CAD (49.8%), 25.8% had PAD alone, and 19.2% had all three territories involved. MALE rate in patients with PAD was 22.3% and 35.0% at 1 and 3 years, respectively. In comparison to PAD alone, the coexistence of both CAD and CVD (ie, polyvascular disease) was associated with a higher adjusted rates of all-cause mortality (hazard ratio [HR], 1.28; 95% confidence interval [CI], 1.24-1.31), myocardial infarction (HR, 1.78; 95% CI, 1.69-1.88), stroke (HR, 1.66; 95% CI, 1.52,1.80), and MALE (HR, 1.07; 95% CI, 1.04-1.11). CONCLUSIONS: Patients with end-stage kidney disease have a high burden of PAD with poor long-term outcomes, which worsen, in an incremental fashion, with the involvement of each additional diseased arterial bed.


Asunto(s)
Enfermedad de la Arteria Coronaria , Fallo Renal Crónico , Infarto del Miocardio , Enfermedad Arterial Periférica , Accidente Cerebrovascular , Humanos , Femenino , Estados Unidos/epidemiología , Anciano , Masculino , Enfermedad Arterial Periférica/complicaciones , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/terapia , Infarto del Miocardio/etiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Factores de Riesgo , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia
3.
Vasc Med ; 29(2): 135-142, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37936422

RESUMEN

BACKGROUND: Atherosclerotic cardiovascular disease is highly prevalent in patients with end-stage kidney disease (ESKD). Kidney transplant (KT) improves patient survival and cardiovascular outcomes. The impact of preexisting coronary artery disease (CAD) and peripheral artery disease (PAD) on posttransplant outcomes remains unclear. METHODS: This is a retrospective study utilizing the United States Renal Data System. Adult diabetic dialysis patients who underwent first KT between 2006 and 2017 were included. The study population was divided into four cohorts based on presence of CAD/PAD: (1) polyvascular disease (CAD + PAD); (2) CAD without PAD; (3) PAD without CAD; (4) no CAD or PAD (reference cohort). The primary outcome was 3-year all-cause mortality. Secondary outcomes were incidence of posttransplant myocardial infarction (MI), cerebrovascular accidents (CVA), and graft failure. RESULTS: The study population included 19,329 patients with 64.4% men, mean age 55.4 years, and median dialysis duration of 2.8 years. Atherosclerotic cardiovascular disease was present in 28% of patients. The median follow up was 3 years. All-cause mortality and incidence of posttransplant MI were higher with CAD and highest in patients with polyvascular disease. The cohort with polyvascular disease had twofold higher all-cause mortality (16.7%, adjusted hazard ratio (aHR) 1.5, p < 0.0001) and a fourfold higher incidence of MI (12.7%, aHR 3.3, p < 0.0001) compared to the reference cohort (8.0% and 3.1%, respectively). There was a higher incidence of posttransplant CVA in the cohort with PAD (3.4%, aHR 1.5, p = 0.01) compared to the reference cohort (2.0%). The cohorts had no difference in graft failure rates. CONCLUSIONS: Preexisting CAD and/or PAD result in worse posttransplant survival and cardiovascular outcomes in patients with diabetes mellitus and ESKD without a reduction in graft survival.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Fallo Renal Crónico , Trasplante de Riñón , Infarto del Miocardio , Enfermedad Arterial Periférica , Accidente Cerebrovascular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Trasplante de Riñón/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/epidemiología , Enfermedad Arterial Periférica/complicaciones , Infarto del Miocardio/epidemiología , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/epidemiología , Fallo Renal Crónico/cirugía
4.
Catheter Cardiovasc Interv ; 95(2): 309-316, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31638737

RESUMEN

BACKGROUND: Over the last decade, there has been a significant increase in the use of percutaneous left ventricular assist devices(p-LVADs). p-LVADs are being increasingly used during complex coronary interventions and for acute cardiogenic shock. These large bore percutaneous devices have a higher risk of vascular complications. We examined the vascular complication rates from the use of p-LVAD in a national database. METHODS: We conducted a secondary analysis of the National In-patient Sample (NIS) dataset from 2005 till 2015. We used the ICD-9-CM procedure codes 37.68 and 37.62 for p-LVAD placement regardless of indications. We investigated common vascular complications, defining them by the validated ICD 9 CM codes. χ2 test and t test were used for categorical and continuous variables, respectively for comparison. RESULTS: A total of 31,263 p-LVAD placements were identified during the period studied. A majority of patients were male (72.68%) and 64.44% were white. The overall incidence of vascular complications was 13.53%, out of which 56% required surgical treatment. Acute limb thromboembolism and bleeding requiring transfusion accounted for 27.6% and 21.8% of all vascular complications. Occurrence of a vascular complication was associated with significantly higher in-hospital mortality (37.77% vs. 29.95%, p < .001), length of stay (22.7 vs. 12.2 days, p < .001) and cost of hospitalization ($ 161,923 vs. $ 95,547, p < .001). CONCLUSIONS: There is a high incidence of vascular complications with p-LVAD placement including need for vascular surgery. These complications are associated with a higher in-hospital, LOS and hospitalization costs. These findings should be factored into the decision-making for p-LVAD placement.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Choque Cardiogénico/terapia , Enfermedades Vasculares/epidemiología , Función Ventricular Izquierda , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Bases de Datos Factuales , Femenino , Insuficiencia Cardíaca/economía , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/economía , Costos de Hospital , Mortalidad Hospitalaria , Humanos , Incidencia , Pacientes Internos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Implantación de Prótesis/economía , Implantación de Prótesis/mortalidad , Medición de Riesgo , Factores de Riesgo , Choque Cardiogénico/economía , Choque Cardiogénico/mortalidad , Choque Cardiogénico/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología , Enfermedades Vasculares/economía , Enfermedades Vasculares/mortalidad , Enfermedades Vasculares/terapia , Adulto Joven
5.
Catheter Cardiovasc Interv ; 96(7): 1392-1398, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-31769132

RESUMEN

OBJECTIVES: Oral steroids are routinely administered in the United States for prophylaxis of iodinated contrast media hypersensitivity (ICMH). We studied the impact of short-term steroid use in diabetic patients with ICMH undergoing nonemergent coronary angiography. METHODS: We retrospectively analyzed records of diabetic patients with and without ICMH who underwent nonemergent coronary angiography at our center. Primary study endpoint was 30-day major adverse cardiac events (MACE) and secondary endpoints were pre- and postprocedure fasting blood glucose (FBG), highest in hospital blood glucose, pre- and postprocedure systolic blood pressure (SBP), and use of intravenous insulin and antihypertensive medications. RESULTS: A total of 88 diabetics with ICMH (study group) and 76 diabetics without ICMH (control group) undergoing angiography were enrolled. Demographics and hemoglobin A1c values were similar in both groups. Preprocedural FBG was significantly higher in the study group. The study group had significantly higher post angiography FBG (239.93 + 96.88 mg/dl vs. 156.6 + 59.88 mg/dl) and greater use of intravenous (IV) insulin (67.27% vs. 32.43%). Further, those who received steroids had significantly higher systolic SBP postprocedure (146.16 + 25.35 mmHg vs. 130.8 + 21.59 mmHg), a higher incidence of severe hypertension and use of IV antihypertensive medications (80.95% vs. 19.05%) periprocedurally. There were no differences in 30-day MACE between groups. CONCLUSION: Short-term steroid use for ICMH results in a significant increase in surrogate markers for adverse clinical events after coronary procedures. Study findings highlight the need for better periprocedural management of these patients and to limit steroid prophylaxis to those with only true ICMH.


Asunto(s)
Cateterismo Cardíaco , Medios de Contraste/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus , Hipersensibilidad a las Drogas/prevención & control , Intervención Coronaria Percutánea , Esteroides/administración & dosificación , Administración Intravenosa , Administración Oral , Anciano , Antihipertensivos/uso terapéutico , Biomarcadores/sangre , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Presión Sanguínea/efectos de los fármacos , Cateterismo Cardíaco/efectos adversos , Medios de Contraste/administración & dosificación , Angiografía Coronaria/efectos adversos , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamiento farmacológico , Hipersensibilidad a las Drogas/diagnóstico , Hipersensibilidad a las Drogas/etiología , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/tratamiento farmacológico , Hipertensión/fisiopatología , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Esteroides/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 93(7): 1219-1227, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30393992

RESUMEN

OBJECTIVES: To assess the prognostic significance of high vs. low grade coronary artery ectasia (CAE) and the impact of antithrombotic or anticoagulant therapy on adverse cardiac outcomes. BACKGROUND: There is paucity of knowledge on the impact of angiographic characteristics in CAE or that of antithrombotic or anticoagulant therapy on outcomes. METHODS AND RESULTS: In this retrospective study, we reviewed angiograms and medical records of all cases of confirmed CAE (2001-2011). Extent of CAE was categorized using the Markis classification. Types 1 and 2 were categorized as high-grade and types 3 and 4 as low-grade CAE. Angiographic flow was recorded as normal or sluggish (

Asunto(s)
Síndrome Coronario Agudo/prevención & control , Anticoagulantes/uso terapéutico , Aneurisma Coronario/tratamiento farmacológico , Angiografía Coronaria , Vasos Coronarios/efectos de los fármacos , Fibrinolíticos/uso terapéutico , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Velocidad del Flujo Sanguíneo , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/mortalidad , Aneurisma Coronario/fisiopatología , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Dilatación Patológica , Registros Electrónicos de Salud , Femenino , Fibrinolíticos/efectos adversos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
7.
N Engl J Med ; 370(19): 1790-8, 2014 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-24678937

RESUMEN

BACKGROUND: We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. METHODS: We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. RESULTS: A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. CONCLUSIONS: In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Cateterismo Cardíaco , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias , Diseño de Prótesis , Factores de Riesgo , Tasa de Supervivencia
8.
Am J Cardiol ; 210: 37-43, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-38682717

RESUMEN

Patients with end-stage kidney disease (ESKD) on dialysis have an increased burden of coronary artery disease (CAD). This study assessed the trend and outcomes for coronary artery bypass surgery (CABG) in patients with ESKD and stable CAD. We conducted a longitudinal study using the United States Renal Data System of patients with ESKD and stable CAD who underwent CABG from the years 2009 to 2017. The outcomes included in-hospital, long-term mortality, and repeat revascularization. The follow-up was until death, end of Medicare AB coverage, or December 31, 2018. A total of 11,952 patients were identified. The mean age was 62.8 years, 68% were male, and 67% were white. The common co-morbidities included hypertension (97%), diabetes mellitus (75%), and congestive heart failure (53%). A significant decrease in CABG procedures from 2.9 to 1.3 procedures per 1,000 patients with ESKD (p <0.001) was noted during the years studied. The overall in-hospital mortality rate was 5.9%, and there was a significant decrease over the study period (p = 0.01). Although the 30-day mortality rate was 6.9% and remained steady (p = 0.14), the 1-year mortality rate was 22.8% and decreased significantly (p <0.001). At 5 years, the overall survival rate was 35%, and patients with internal mammary artery grafts showed better survival than those without (36% vs 25%). In conclusion, there has been a decrease in CABG procedures performed in patients with ESKD with stable CAD with decreasing in-hospital and 1-year mortality. Those with an internal mammary artery graft do better, but the overall long-term survival remains dismal in this population. There remains need for caution and individualization of revascularization decisions in this high-risk population.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria , Mortalidad Hospitalaria , Fallo Renal Crónico , Humanos , Masculino , Fallo Renal Crónico/epidemiología , Fallo Renal Crónico/cirugía , Femenino , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/epidemiología , Persona de Mediana Edad , Estados Unidos/epidemiología , Anciano , Mortalidad Hospitalaria/tendencias , Estudios Longitudinales , Diálisis Renal , Resultado del Tratamiento
9.
J Am Coll Cardiol ; 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39222896

RESUMEN

BACKGROUND: TRILUMINATE Pivotal is a prospective, randomized, controlled study of patients with severe tricuspid regurgitation (TR). Venous congestion due to TR may lead to end-organ dysfunction and failure. The potential to reverse or stop further deterioration in end-organ function is an important goal of treatment. OBJECTIVES: Examine changes in end-organ function after tricuspid transcatheter edge-to-edge repair (TEER) and assess the association of baseline end-organ function with heart failure (HF) hospitalizations and mortality. METHODS: Subjects were randomized 1:1 to either the TEER group (TriClip™ System + medical therapy) or Control group (medical therapy alone). Laboratory assessments and TR grading were performed at baseline and at all follow-up visits (discharge, 30 days, 6 months, and 12 months). An independent echocardiography core laboratory assessed TR severity and an independent clinical events committee adjudicated adverse events. RESULTS: 572 subjects were enrolled and randomized (285 TEER, 287 Control). Patients with moderate to severe end-organ impairment (eGFR <45 ml/min/1.73m2 or MELD-XI >15) at baseline had increased incidence of HF hospitalization and death through 12 months, regardless of treatment. There were no statistically significant differences between TEER and Control in eGFR or MELD-XI at 12 months. In subgroup analyses examining only successful TEER patients (moderate or less TR at discharge) compared to control patients, as well as when censoring patients with normal baseline values, both eGFR (+3.55 ± 1.04 vs 0.07 ± 1.10 , p=0.022) and MELD-XI (-0.52 ± 0.18 vs 0.34 ± 0.18, p=0.0007) improved. CONCLUSIONS: Baseline end-organ function were associated with HF hospitalization and death in patients with severe TR. At 12 months, eGFR and MELD-XI scores were not statistically significantly different between the overall TEER and Control groups. In patients who had successful TEER, statistically significant, yet small, favorable changes occurred for both eGFR and MELD-XI. Further investigation is needed to assess whether these changes in end-organ function after successful TEER are clinically meaningful and reduce HF hospitalization or death.

10.
Hypertension ; 80(4): e59-e67, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36752114

RESUMEN

BACKGROUND: There is paucity of information on the incidence, clinical characteristics, admission trends, and outcomes of hypertensive crisis (HTN-C) in patients with end-stage kidney disease (ESKD) who are on maintenance dialysis. METHODS: We conducted a retrospective observational study of HTN-C admissions in patients with end-stage kidney disease using the United States Renal Data System. We identified patients with end-stage kidney disease aged ≥18 years on dialysis and were hospitalized for HTN-C from January 2006 to August 2015. RESULTS: A total of 54 483 patients with end-stage kidney disease were hospitalized for HTN-C during the study period. After study exclusions, 37 214 patients were included in the analysis. A majority of patients were Black, there were more women than men and the South region of the country accounted for a great majority of patients. During the study period, hospitalization rates increased from 1060 per 100 000 beneficiary years to 1821 (Ptrend<0.0001). Overall, in-hospital mortality, 30-day, and 1-year mortality were 0.6%, 2.3%, and 21.8%, respectively, and 30-day readmission rate was 31.1%. During the study period, most study outcomes showed a significant decreasing trend (in-hospital mortality 0.6%-0.5%, 30-day mortality 2.4%-1.9%, 1-year mortality 23.9%-19.7%, Ptrend<0.0001 for all). CONCLUSIONS: Hospitalizations for HTN-C have increased consistently during the decade studied. Although temporal trends showed improving mortality and readmission rates, the absolute rates were still high with 1 in 3 patients readmitted within 30 days and 1 in 5 patients dying within 1 year of index hospitalization.


Asunto(s)
Fallo Renal Crónico , Diálisis Renal , Masculino , Humanos , Femenino , Estados Unidos/epidemiología , Adolescente , Adulto , Diálisis Renal/efectos adversos , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/epidemiología , Fallo Renal Crónico/terapia , Hospitalización , Readmisión del Paciente , Estudios Retrospectivos
11.
J Am Coll Emerg Physicians Open ; 3(1): e12618, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35072159

RESUMEN

OBJECTIVES: Cocaine use (CU) related chest pain (CP) is a common cause of emergency department (ED) visits in the United States. However, information on disposition and outcomes in these patients is scarce. We conducted a nationwide study to assess disposition from ED, hospitalization rates, in-hospital outcomes, and health care costs in patients with history of CU who presented to the ED with CP. METHODS: We queried the Nationwide Emergency Department Sample database from 2016-2018 for adult patients with CU presenting to the ED with CP. International Classification of Diseases, Tenth Revision codes were used to identify study patients. RESULTS: We identified 149,372 patients. The majority were male (76%), presented to metropolitan centers (91.3%), and had a high prevalence of cardiovascular risk factors (48.1% with hypertension, 24.4% with coronary artery disease, 18.2% with diabetes) and psychiatric illnesses (21%). Overall, 21.4% of patients were hospitalized, 68.6% were discharged from ED and 6.6% left against medical advice. Patients requiring admission were older (51.8 vs 45.0; P < 0.0001) and had a higher prevalence of coronary artery disease, peripheral arterial disease, hypertension, diabetes, and chronic kidney disease. Of those admitted, 45.7% were diagnosed with myocardial infarction (MI), constituting 9.7% of the total study population. Over 80% of these patients underwent coronary angiography and 38.6% had coronary intervention. Mortality was 1.2%. CONCLUSION: CU patients who present to ED are predominantly male, are from lower economic strata, and have significant comorbidity burden. One in 5 patients requires hospitalization and has more prevalent cardiovascular risk factors and comorbidities. In-hospital mortality is low, but incidence of MI and subsequent invasive procedures is high. CU may be considered a cardiac risk factor as it is associated with high rates of in-hospital MI.

12.
Am J Cardiol ; 168: 110-116, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35101271

RESUMEN

Transcatheter aortic valve implantation (TAVI) has comparable outcomes with surgical aortic valve replacement (SAVR) in symptomatic patients with severe aortic stenosis, including those at low risk for surgery. Less is known about TAVI outcomes in asymptomatic patients. This analysis compares clinical, hemodynamic, and quality of life (QOL) outcomes after TAVI or SAVR for low-risk asymptomatic patients. The randomized Evolut Low Risk trial enrolled asymptomatic patients treated with TAVI (n = 76) and SAVR (n = 62). New York Heart Association functional class I identified patients without symptoms. Clinical outcomes, echocardiographic findings, and QOL in both groups were compared 30 days and 12 months after AVR. Asymptomatic patients had a mean Society of Thoracic Surgeons score of 1.7 ± 0.6, 73% were men, and mean age was 74.2 ± 5.8 years. The composite end point of all-cause mortality or disabling stroke was similar at 12 months in patients with TAVI (1.3%) and SAVR (6.5%; p = 0.11), although patients with SAVR tended to have higher rates of all-cause mortality (4.8%) compared with patients with TAVI (0.0%, p = 0.05). Patients with TAVI had lower mean aortic valve gradients (8.1 ± 3.2 mm Hg) and larger mean effective orifice area (2.3 ± 0.6 mm Hg) than patients with SAVR (10.8 ± 3.8; p <0.001 and 1.9 ± 0.6; p = 0.001, respectively), and showed significant improvement in Kansas City Cardiomyopathy Questionnaire scores from baseline to 30 days (∆12.1 ± 23.6; p <0.001), whereas patients with SAVR did not (∆2.2 ± 20.3; p = 0.398). Patients with TAVI and SAVR had a significant improvement in QOL by 12 months compared with baseline. In conclusion, low risk asymptomatic patients with severe aortic stenosis who underwent TAVI had comparable clinical outcomes to SAVR, with superior valve performance and faster QOL improvement.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Calidad de Vida , Factores de Riesgo , Resultado del Tratamiento
13.
J Am Coll Cardiol ; 79(9): 882-896, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-35241222

RESUMEN

BACKGROUND: The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up. OBJECTIVES: The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial. METHODS: A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference: -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves. CONCLUSIONS: The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Teorema de Bayes , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 77(1): 45-8, 2011 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-20506280

RESUMEN

INTRODUCTION: Patients with end-stage liver disease (ESLD) awaiting transplant are at increased risk of bleeding. Nevertheless, these patients routinely undergo cardiac catheterization for various indications. Safety and outcomes of cardiac catheterization in these patients are not well reported. METHODS: In a case-control study 43 patients with ESLD who underwent angiography for liver transplant work-up were compared to 43 age and gender-matched controls with no liver dysfunction. In-hospital outcomes and procedural variables were compared. RESULTS: Patients with ESLD had a lower baseline hemoglobin (12.1 ± 2.1 vs. 13.7 ± 1.8, P < 0.0005), lower platelet counts (86.8 ± 66 vs. 247 ± 80, P < 0.0001) and higher international normalized ratio (INR) (1.4 ± 0.2 vs. 1.1 ± 0.2, P < 0.0001) than controls. Among ESLD group, five (11.6%) patients received platelet transfusions, one received blood transfusion, and three patients (7%) with INR > 1.6 received fresh frozen plasma (FFP) compared with none in the control group. Smaller size (four French) vascular sheaths were used more frequently in the group with ESLD (16% vs. 4%, P = 0.04). There were no significant vascular or bleeding complications in either group. CONCLUSIONS: Elective cardiac catheterization can be safely performed in patients with ESLD with outcomes (vascular and bleeding complications, length of hospital stay and in-hospital mortality) similar to patients without liver disease despite significant thrombocytopenia and elevated INR in patients with ESLD. Practices such as platelet transfusion for platelets <60,000 µL, prophylactic FFP transfusion for INR ≥ 1.6, less frequent use of antiplatelet therapy and more frequent use of smaller vascular sheaths may have contributed to the safety of cardiac catheterization in ESLD patients.


Asunto(s)
Angioplastia Coronaria con Balón , Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad Hepática en Estado Terminal/complicaciones , Hemorragia/prevención & control , Técnicas Hemostáticas , Centros Médicos Académicos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Transfusión Sanguínea , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Estudios de Casos y Controles , Catéteres , Distribución de Chi-Cuadrado , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/instrumentación , Enfermedad Hepática en Estado Terminal/sangre , Diseño de Equipo , Femenino , Hemoglobinas/análisis , Hemorragia/sangre , Hemorragia/etiología , Humanos , Relación Normalizada Internacional , Kansas , Tiempo de Internación , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Recuento de Plaquetas , Transfusión de Plaquetas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
15.
Cardiovasc Revasc Med ; 26: 12-16, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33199247

RESUMEN

BACKGROUND: Paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) is associated with increased morbidity and mortality. PVR continues to plague TAVR jeopardizing long-term results. New device iterations, such as the self-expandable Evolut PRO valve, aim to decrease PVR while maintaining optimal hemodynamics. This study sought to evaluate clinical and hemodynamic performance of the Evolut PRO system at 3 years. METHODS: The Evolut PRO US Clinical Study included 60 patients at high or extreme surgical risk undergoing TAVR with the Evolut PRO valve at 8 centers in the United States. Clinical outcomes were evaluated using Valve Academic Research Consortium (VARC)-2 criteria and included all-cause mortality, cardiovascular mortality, disabling stroke and valve complications. An independent core laboratory centrally assessed all echocardiographic measures. RESULTS: At 3 years, all-cause mortality was 25.8% (cardiovascular mortality 16.5%) and the disabling stroke rate was 10.7%. There were no cases of repeat valve intervention, endocarditis or coronary obstruction. Valve thrombosis was identified in 1 patient 2 years post-procedure and was treated medically. Hemodynamics at 3 years included a mean gradient of 7.2 ± 4.5 mm Hg, an effective orifice area of 2.0 ± 0.5 cm2, and 88.2% of patients had no or trace PVR. The remaining patients had mild PVR. Most of the surviving patients (80.6%) had New York Heart Association class I symptoms at 3 years. CONCLUSION: Outcomes at 3-years following TAVR with a contemporary self-expanding prosthesis are favorable, with no signal of valve deterioration, excellent hemodynamics including very low prevalence of PVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados Unidos/epidemiología
16.
Ann Thorac Surg ; 112(3): 778-785, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33217396

RESUMEN

BACKGROUND: An increasing body of evidence suggests that packed red blood cell (PRBC) transfusion may be associated with increased morbidity and mortality after transcatheter and surgical aortic valve replacement. It remains unclear whether PRBC transfusion is a surrogate marker or truly an independent risk factor for mortality after aortic valve replacement in different populations. METHODS: The Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) trial randomized 1660 patients with symptomatic, severe aortic stenosis at intermediate risk for operative death to transcatheter aortic valve replacement or surgical aortic valve replacement. Baseline characteristics and outcomes including all-cause and cardiovascular mortality at 30 days and thereafter were compared between participants with and participants without PRBC transfusion. Cox proportional hazards models with time-varying covariates were fitted to estimate the effect of PRBC transfusion on mortality after adjustment for comorbidities and procedural complications. RESULTS: Patients receiving PRBC were older, more commonly female and frail, with more comorbidities. The Society of Thoracic Surgeons Predicted Risk of Mortality baseline score was higher in the transfused group. After adjustment for these differences, PRBC transfusion was associated with mortality at 30 days, but not thereafter. The effect of PRBC on mortality (hazard ratio 1.04; 95% confidence interval, 0.96 to 1.11; P = .304) at 30 days was not independent of procedural complications (hazard ratio 21.04; 95% CI, 7.26 to 60.95; P < .001). CONCLUSIONS: Poor health status, procedural complications, PRBC transfusion, and mortality are correlated with each other. Transfusion of PRBC did not independently increase risk for mortality. In this intermediate-risk population, transfusion appears to be a risk marker of chronic conditions and periprocedural complications as opposed to a risk factor for postprocedural mortality. (Clinical trial registration: www.clinicaltrials.gov NCT01586910.).


Asunto(s)
Válvula Aórtica/cirugía , Transfusión de Eritrocitos/efectos adversos , Complicaciones Posoperatorias/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo
17.
J Interv Cardiol ; 23(2): 179-87, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20236217

RESUMEN

INTRODUCTION: The study goal was to evaluate the cost-effectiveness of drug-eluting stent (DES) placement with consideration of gastrointestinal (GI) bleeding risk. DES reduce the need for future coronary revascularization, but require prolonged dual anti-platelet (DAT) therapy, which may increase the risk for GI bleeding. While DES have been found to be cost-effective in patients at average risk for GI bleeding, they may not be the most cost-effective strategy in higher risk patients. METHODS: A Markov model was created to compare DES with bare metal stents (BMS). Patients were a hypothetical cohort of 60-year-old individuals with coronary artery stenosis that required nonemergent percutaneous coronary revascularization (PCI). The primary outcomes were the threshold incremental risks of GI bleeding from DAT based on willingness to pay (WTP) of $50,000, $100,000, and $150,000 per quality adjusted life year (QALY) gained. RESULTS: For a WTP of $100,000, the relative risk of GI bleeding from DAT could be as high as 10.8 (when compared to aspirin alone) before DES would no longer be cost-effective. In patients with two risk factors for GI bleeding, the threshold relative risk could be as low as 1.6. CONCLUSION: In average-risk patients, the risk of GI bleeding from DAT can be substantial without affecting the cost-effectiveness of DES. However, DES are unlikely to be cost-effective in patients with two or more risk factors for GI bleeding.


Asunto(s)
Estenosis Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Stents Liberadores de Fármacos/economía , Hemorragia Gastrointestinal/etiología , Pacientes , Angioplastia Coronaria con Balón , Aspirina/uso terapéutico , Estudios de Cohortes , Análisis Costo-Beneficio , Diseño de Equipo , Humanos , Cadenas de Markov , Persona de Mediana Edad , Años de Vida Ajustados por Calidad de Vida , Riesgo , Medición de Riesgo , Stents/efectos adversos
18.
Cardiovasc Revasc Med ; 19(4): 438-443, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29402710

RESUMEN

BACKGROUND: The ACC/AHA guidelines recommend low-dose dobutamine challenge for hemodynamic assessment of the severity of AS in patients with low flow, low gradient aortic stenosis with reduced ejection fraction (EF) (LFLG-AS; stage D2). Inherent pitfalls of echocardiography could result in inaccurate aortic valve areas (AVA), which have downstream prognostic implications. Data on the safety and efficacy of coronary pressure wire and fluid-filled catheter use for low dose dobutamine infusion is sparse. METHODS: We retrospectively analyzed 39 consecutive patients with EF<50%, AVA<1cm2 and SVI<35ml/m2 on echocardiography who underwent simultaneous right and left heart catheterization. Hemodynamic assessments were performed at baseline and at every increment in the dobutamine infusion rate (The infusion was continued until maximal dose of dobutamine or a mean AV gradient>40mmHg was attained. The occurrence of sustained ventricular arrhythmias, symptomatic hypotension or intolerable symptoms leading to cessation of infusion was recorded. Transient ischemic attacks (TIAs) or clinically apparent strokes periprocedurally or up to 30days after the procedure were recorded. RESULTS: Dobutamine challenge confirmed true AS in 26 patients (67%) and pseudosevere AS in 34%. No sustained arrhythmias, hypotension or cessation of infusion from intolerable symptoms were observed. No clinical strokes or TIAs were observed up to 30days after procedure in any of these patients. CONCLUSIONS: Hemodynamic assessment of AS using a pressure wire with dobutamine challenge is a safe and effective tool in identifying truly severe AS in patients with LFLG-AS with reduced EF.


Asunto(s)
Agonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Estenosis de la Válvula Aórtica/diagnóstico , Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Circulación Coronaria , Dobutamina/administración & dosificación , Volumen Sistólico , Transductores de Presión , Función Ventricular Izquierda , Agonistas de Receptores Adrenérgicos beta 1/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Dobutamina/efectos adversos , Ecocardiografía , Registros Electrónicos de Salud , Diseño de Equipo , Femenino , Humanos , Infusiones Intravenosas , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
20.
JACC Cardiovasc Interv ; 11(2): 160-168, 2018 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-29348010

RESUMEN

OBJECTIVES: This study sought to evaluate the Medtronic Evolut PRO Transcatheter Aortic Valve System in patients with severe symptomatic aortic stenosis. BACKGROUND: A next-generation self-expanding transcatheter aortic valve was designed with an external pericardial wrap with the intent to reduce paravalvular leak while maintaining the benefits of a low-profile, self-expanding, and repositionable supra-annular valve. METHODS: The Medtronic Evolut PRO Clinical Study included 60 patients undergoing transcatheter aortic valve replacement with the Evolut PRO valve at 8 investigational sites in the United States. Clinical outcomes at 30 days were evaluated using Valve Academic Research Consortium-2 criteria. The 2 primary safety endpoints were the incidence of all-cause mortality at 30 days and the incidence of disabling stroke at 30 days. The primary efficacy endpoint was the proportion of patients with no or trace prosthetic valve regurgitation at 30 days. An independent echocardiographic core laboratory (Mayo Clinic, Rochester, Minnesota) was used to adjudicate all echocardiographic assessments. RESULTS: All 60 patients received the Evolut PRO valve. At 30 days, 1 patient (1.7%) died and 1 patient (1.7%) experienced a nonfatal disabling stroke. Paravalvular regurgitation at 30 days was absent or trace in 72.4% of patients and was mild in the remainder of patients, with no patients having worse than mild paravavlular leak. The mean atrioventricular gradient was 6.4 ± 2.1 mm Hg and effective orifice area was 2.0 ± 0.5 cm2 at 30 days. CONCLUSIONS: The safety and efficacy results of this study support the use of the Evolut PRO System for the treatment of severe symptomatic aortic stenosis in patients who are at increased surgical risk, resulting in excellent hemodynamics and minimal paravalvular leak (The Medtronic TAVR 2.0 US Clinical Study; NCT02738853).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/prevención & control , Pericardio/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Causas de Muerte , Ecocardiografía , Femenino , Hemodinámica , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA