1.
Biomed Eng Online ; 16(1): 136, 2017 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-29202876

RESUMEN

BACKGROUND: Adolescent idiopathic scoliosis, in which obvious curves are visible in radiographic images, is also seen in combination with lumps in the back. These lumps contribute to inclination, which can be measured by a scoliometer. To the authors' knowledge, there are no previous formulas combining thoracic and lumbar scoliometer values simultaneously to predict thoracic and lumbar Cobb angles, respectively. This study aimed to create more accurate two-parameter mathematical formulas for predicting thoracic and lumbar Cobb angles. METHODS: Between Dec. 2012 and Jan. 2013, patients diagnosed with idiopathic scoliosis in an outpatient clinic were enrolled. The maximal trunk rotations at the thoracic and lumbar regions were recorded with a scoliometer. Right asymmetry hump was deemed positive (+), and left asymmetry hump was deemed negative (-). The Cobb angles were measured with a Picture Archiving and Communication System. Statistical analysis included Pearson's correlation coefficient, multivariate regression and Bland-Atman analysis. RESULTS: One-hundred and one patients were enrolled in our study. The average thoracic curve (TC) was 23.3 ± 1.8°, while the average lumbar curve (LC) was - 23.3 ± 1.4°. The thoracic inclination (TI) and lumbar inclination (LI) were 4.5 ± 0.7 and - 5.9 ± 0.6, respectively. The one-parameter formula for the thoracic curve was TC = 2.0 TI + 14.3 (r = 0.813); for the lumbar curve, it was LC = 0.9 LI - 16.9 (r = 0.409). By multivariate regression, the two-parameter formulas for the thoracic and lumbar curves were TC = 2.6 TI - 1.4 LI (r = 0.931) and LC = - 1.5 TI + 2.0 LI (r = 0.874), respectively. The two-parameter formulas were more accurate than the one-parameter formulas. CONCLUSIONS: Based on the results of these two-parameter formulas for thoracic and lumbar curves, the Cobb angles can be predicted more accurately by the readings of the scoliometer. Physicians and other healthcare practitioners can thus evaluate patients with scoliosis more precisely than before with a scoliometer.


Asunto(s)
Escoliosis/patología , Torso , Adolescente , Fenómenos Biomecánicos , Niño , Femenino , Humanos , Vértebras Lumbares/patología , Masculino , Rotación , Vértebras Torácicas/patología , Adulto Joven
2.
Knee Surg Sports Traumatol Arthrosc ; 24(10): 3262-3271, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27056688

RESUMEN

PURPOSE: Distal femur fractures adjacent to total knee arthroplasty are a rare yet complex problem. Recently, extramedullary locking plate and retrograde intramedullary nail fixations have become popular options, but the complication rates associated with these procedures are 15-20 %. Modified fixations were assessed in an effort to reduce complications from unstable periprosthetic fractures. METHODS: Using experimental and finite element methods, this study compared the construct behaviours of a locking plate, a retrograde intramedullary nail, and their modifications (a spiral-blade supplemented in an intramedullary nail or a locking plate/allograft hybrid) when subjected to various fracture types, locations, loading conditions, and bony strength. The implanted models were used to assess construct stiffness, fracture micromotion, and implant stress under different osteoporotic conditions. Finally, we collected 40 cases for radiological analysis to indicate the appropriate procedure for treating periprosthetic fractures following total knee arthroplasty. RESULTS: Regardless of the fracture type, femoral constructs fixed with a conventional or spiral-blade supplemented intramedullary nail exhibited higher axial but lower torsional stiffness than those fixed with a locking plate. Torsional deformation occurred if the lower-positioned fracture had no medial support. The locking plate/allograft construct exhibited the highest stiffness and the least micromotion. A review of 40 clinical cases confirmed the above findings regarding the locking plate/allograft construct. CONCLUSION: The spiral-blade supplement of retrograde intramedullary nail and locking plate/allograft modified constructs significantly stabilizes the unstable fractured gaps. The locking plate/allograft is recommended for the periprosthetic fractures with deficient bone stock and severe osteoporosis to improve alignment and healing potentials.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/métodos , Fracturas Periprotésicas/cirugía , Clavos Ortopédicos , Placas Óseas , Simulación por Computador , Fracturas del Fémur/etiología , Análisis de Elementos Finitos , Humanos , Ensayo de Materiales , Modelos Biológicos
3.
Acta Orthop Belg ; 81(1): 147-54, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26280868

RESUMEN

UNLABELLED: An absolutely convincing technique of anterior transfer of the tibialis posterior (TP) tendon for treating drop foot has not been developed. Thirty-seven consecutive adult patients with drop foot owing to deep peroneal nerve injury were treated with bone-to-bone TP tendon transfer. The TP tendon with a small bony attachment was procured from the undersurface of the navicula and then transferred through a tunnel of the interosseous membrane. The navicular attachment was implanted in the tunnel of the navicula or intermediate cuneiform. Cancellous bone graft procured from the distal tibial metaphysis was packed into the tunnel inlet. Side-to-side tendon suturing was performed between the TP tendon and tibialis anterior tendon. Thirty-one patients were followed for a mean of 2.8 years (range, 1.2-4.8 years), and all achieved satisfactory outcome for the ankle. All patients achieved a normal gait after one year and at the latest follow-up. CONCLUSIONS: The described technique may provide a high success rate. This surgical technique is not complex, and complications are few.


Asunto(s)
Pie Equino/cirugía , Transferencia Tendinosa/métodos , Tendón Calcáneo/cirugía , Adulto , Articulación del Tobillo/fisiopatología , Pie Equino/fisiopatología , Femenino , Trastornos Neurológicos de la Marcha/fisiopatología , Trastornos Neurológicos de la Marcha/cirugía , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
4.
BMC Musculoskelet Disord ; 15: 262, 2014 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-25095740

RESUMEN

BACKGROUND: Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narrowing of the femoral neck has often been found, which may lead to fracture. This phenomenon has been attributed to the stress alteration (stress shielding). Studies addressing the effects of necrotic size and the orientation of the implant on stress alterations are lacking. METHODS: Computed tomography images of a standard composite femur were used to create a three-dimensional finite-element (FE) intact femur model. Based on the intact model, FE models simulating four different levels of necrotic regions (0°, 60°, 100°, 115°) and three different implant insertion angles (varus 10°, neutral, valgus 10°) were created. The von Mises stress distributions and the displacement of the stem tip of each model were analyzed and compared for loading conditions that simulated a single-legged stance. RESULTS: Stress shielding occurred at the femoral neck after HRA. More severe stress shielding and an increased displacement of the stem tip were found for femoral heads that had a wider necrotic lesion. From a biomechanics perspective, the results were consistent with clinical evidence of femoral neck narrowing after HRA. In addition, a varus orientation of the implant resulted in a larger displacement of the stem tip, which could lead to an increased risk of implant loosening. CONCLUSIONS: A femoral head with a wide necrotic lesion combined with a varus orientation of the prosthesis increases the risk of femoral neck narrowing and implant loosening following HRA.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Simulación por Computador , Necrosis de la Cabeza Femoral/cirugía , Análisis de Elementos Finitos , Prótesis de Cadera , Modelos Anatómicos , Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/fisiopatología , Humanos , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
BMC Musculoskelet Disord ; 15: 197, 2014 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-24913189

RESUMEN

BACKGROUND: The biomechanical performance of the hooks and screws in spinal posterior instrumentation is not well-characterized. Screw-bone interface failure at the uppermost and lowermost vertebrae is not uncommon. Some have advocated for the use of supplement hooks to prevent screw loosening. However, studies describing methods for combined hook and screw systems that fully address the benefits of these systems are lacking. Thus, the choice of which implant to use in a given case is often based solely on a surgeon's experience instead of on the biomechanical features and advantages of each device. METHODS: We conducted a biomechanical comparison of devices instrumented with different combinations of hooks and screws. Thirty-six fresh low thoracic porcine spines were assigned to three groups (12 per group) according to the configuration used for of fixation: (1) pedicle screw; (2) lamina hook and (3) combination of pedicle screw and lamina hook. Axial pullout tests backward on transverse plane in the direction normal to the rods were performed using a material testing machine and a specially designed grip with self-aligned function. RESULTS: The pullout force for the pedicle screws group was significantly greater than for the hooks and the combination (p < 0.05). However, no significant difference was found between the hooks and the combination (p > 0.05). CONCLUSIONS: Pedicle screws achieve the maximal pullout strength for spinal posterior instrumentation.


Asunto(s)
Fijadores Internos , Vértebras Torácicas/cirugía , Animales , Fenómenos Biomecánicos , Tornillos Óseos , Falla de Equipo , Técnicas In Vitro , Movimiento (Física) , Estrés Mecánico , Sus scrofa , Porcinos , Soporte de Peso
6.
Front Bioeng Biotechnol ; 12: 1359883, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38380264

RESUMEN

Despite advancements in pedicle screw design and surgical techniques, the standard steps for inserting pedicle screws still need to follow a set of fixed procedures. The first step, known as establishing a pilot hole, also referred to as a pre-drilled hole, is crucial for ensuring screw insertion accuracy. In different surgical approaches, such as minimally invasive or traditional surgery, the method of creating pilot holes varies, resulting in different pilot hole profiles, including variations in size and shape. The aim of this study is to evaluate the biomechanical properties of different pilot hole profiles corresponding to various surgical approaches. Commercially available synthetic L4 vertebrae with a density of 0.16 g/cc were utilized as substitutes for human bone. Four different pilot hole profiles were created using a 3.0 mm cylindrical bone biopsy needle, 3.6 mm cylindrical drill, 3.2-5.0 mm conical drill, and 3.2-5.0 mm conical curette for simulating various minimally invasive and traditional spinal surgeries. Two frequently employed screw shapes, namely, cylindrical and conical, were selected. Following specimen preparation, screw pullout tests were performed using a material test machine, and statistical analysis was applied to compare the mean maximal pullout strength of each configuration. Conical and cylindrical screws in these four pilot hole configurations showed similar trends, with the mean maximal pullout strength ranking from high to low as follows: 3.0 mm cylindrical biopsy needle, 3.6 mm cylindrical drill bit, 3.2-5.0 mm conical curette, and 3.2-5.0 mm conical drill bit. Conical screws generally exhibited a greater mean maximal pullout strength than cylindrical screws in three of the four different pilot hole configurations. In the groups with conical pilot holes, created with a 3.2-5.0 mm drill bit and 3.2-5.0 mm curette, both conical screws exhibited a greater mean maximal pullout strength than did cylindrical screws. The strength of this study lies in its comprehensive comparison of the impact of various pilot hole profiles commonly used in clinical procedures on screw fixation stability, a topic rarely reported in the literature. Our results demonstrated that pilot holes created for minimally invasive surgery using image-guided techniques exhibit superior pullout strength compared to those utilized in traditional surgery. Therefore, we recommend prioritizing minimally invasive surgery when screw implantation is anticipated to be difficult or there is a specific need for stronger screw fixation. When opting for traditional surgery, image-guided methods may help establish smaller pilot holes and increase screw fixation strength.

7.
Spine J ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38499068

RESUMEN

BACKGROUND CONTEXT: Long-segment pedicle screw instrumentation is widely used to treat complex spinal disorders. Rods are routinely precontoured to maximize assistance on the correcting side of the deformity, but there often exists a residual gap discrepancy between the precontoured rods and screw tulips. No previous research has investigated the diminished pullout strength of the most proximal or distal pedicle screw resulting from a mismatched rod in long-segment pedicle screw instrumentation. PURPOSE: The present study aimed to investigate the decreased pullout force of pedicle screws affected by the gap discrepancy when forcefully engaging a mismatched rod into a tulip in a normal-density porcine spine. STUDY DESIGN: The pedicle screw fixation strength under axial pullout force was compared among three different gap discrepancies between rods and tulips using long porcine spine segments. METHODS: Twelve porcine lumbar vertebrae (L3-L6) were implanted with pedicle screws and rods. Screws on one side had no gap between the tulip and rod (0-mm group), while the most proximal screw on the other side had an intentional gap of 3 mm (3-mm group) or 6 mm (6-mm group). Three hours after forcefully engaging the rod into the tulips at room temperature, the set screws in all specimens were loosened, and each specimen was dissected into individual vertebrae for subsequent pullout testing. RESULTS: The control group exhibited significantly greater pullout strength (1987.68 ± 126.80 N) than the groups from different rod-tulip configurations (p<.05), with significantly greater strength in the 3-mm group (945.62 ± 97.43 N) than the 6-mm group (655.30 ± 194.49 N) (p<.05). Only 47.6% and 33.0% of the pullout strength was retained in the 3-mm and 6-mm groups, respectively, compared to the control group. CONCLUSIONS: Gap discrepancies between rods and tulips can significantly reduce pedicle screw pullout strength, with a correlation between decreased strength and increased gaps. Surgeons should avoid forcefully engaging mismatched rods and consider well-fitted contoured rods in spinal surgery to minimize the risk of screw loosening. CLINICAL SIGNIFICANCE: The gap discrepancy between rod and tulip significantly affected pullout strength, with greater gaps leading to reduced strength. Forcefully engaging mismatched rods into tulips in degenerative spinal surgery should be avoided to minimize the risk of early screw pullout.

8.
Global Spine J ; 13(1): 25-32, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33511875

RESUMEN

STUDY DESIGN: Biomechanical study. OBJECTIVE: Cross-links are a type of common clinical spinal instrumentation. However, the effects of the position and number of cross-links have never been investigated in long-segment spinal fixation, and the variables have not been optimized. We conducted an in vitro biomechanical study by using a porcine long-segment spinal model with 5 different crosslink configurations to determine the optimal construct for clinical practice. METHODS: Five modalities with paired segmental screws from T15-L5 were tested in 20 porcine spines. The spines without cross-links composed the control group, Group A; those with a single cross-link from L2-3 composed Group B; those with 2 cross-links from L1-2 and L3-4 composed Group C; those with 2 cross-links from T15-L1 and L4-5 composed Group D; and those with 3 cross-links from T15-L1, L2-3 and L4-5 composed Group E. Spinal stiffnesses in flexion, extension, lateral bending, and axial rotation were compared among 5 different cross-link configurations in 5-level porcine spinal units. RESULTS: Flexional, extensional and lateral bending stiffnesses did not significantly change with an increasing number of cross-links or positions in the construct. Axial stiffness was significantly increased with 2 cross-links compared to one (P < 0.05) and with placement more distant from the center of the long spinal fixation construct (P < 0.05). CONCLUSIONS: Two cross-links individually placed proximal and distal from the center of a construct is an optimal and efficient configuration to achieve biomechanical stability in non-rigid lumbar spines undergoing long-level fixation.

9.
Spine J ; 23(2): 315-324, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36058516

RESUMEN

BACKGROUND CONTEXT: Pedicle screw-rod assembly procedures following pedicle screw insertion include contouring and placing rods into screw tulips, introducing set screws into the tulip along the screw thread, applying a counter-torque holder and tightening all the set screws clockwise. Even if an appropriate pedicle screw is implanted, screw dislodgement after tightening of the tulip and set screw is not uncommon. Pedicle wall violation resulting from excessive rotational force due to inadequate use of a counter-torque holder might be the reason. However, the strain change in the pedicle during tulip-set screw tightening and the role of counter-torque have never been investigated. PURPOSE: This study determined differences in the strain change in the outer and inner pedicle walls during tulip-set screw tightening; additionally, the influence of counter-torque on pedicle wall violation was elucidated. STUDY DESIGN: A controlled biomechanical study; the strain values of outer and inner pedicle walls in cadaveric porcine L4-L5 vertebrae during tulip-set screw tightening with or without a counter-torque holder were measured. METHODS: Twelve L4-L5 fresh-frozen porcine lumbar vertebrae were implanted with screw-rod constructs; the set screw was randomly locked into the tulip in the right L5, right L4, left L5 and left L4 testing groups. The maximal values from eight strain gauges (P-R-O: outer cortex of right pedicle in proximal vertebra; P-R-I: inner cortex of right pedicle in proximal vertebra; D-R-O: outer cortex of right pedicle in distal vertebra; D-R-I: inner cortex of right pedicle in distal vertebra; P-L-O: outer cortex of left pedicle in proximal vertebra; P-L-I: inner cortex of left pedicle in proximal vertebra; D-L-O: outer cortex of left pedicle in distal vertebra; D-L-I: outer cortex of left pedicle in proximal vertebra) for each specimen during tightening to 12 Nm were measured. RESULTS: The maximal strain values of the ipsilateral strain gauges in all testing groups were almost significantly higher when a counter-torque holder was not used than when one was used. The strain values in the adjacent pedicle of specimens without a counter-torque holder were significantly increased: P-R-O and P-R-I in the right L5 group; D-R-I in the right L4 group; P-L-I and P-L-O in the left L5 group; D-L-O and D-L-I in the left L4 group. CONCLUSIONS: The constraint effect of counter-torque during tulip-set screw tightening is necessary. Clockwise rotational force with a fragile lateral pedicle wall suggests that caution is required when using a counter-torque holder to tighten the right L5 and left L4 constructs. CLINICAL SIGNIFICANCE: A counter-torque holder is important during tulip-set screw tightening; improper use may lead to adjacent pedicle wall violation, sequentially resulting in pedicle screw loosening.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Animales , Fenómenos Biomecánicos , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Porcinos , Torque
10.
Sci Rep ; 13(1): 454, 2023 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-36624133

RESUMEN

Although an anterior approach with anterior lateral screw fixation has been developed for stabilizing the thoracolumbar spine clinically, screw loosening still occurs. In this novel in vitro study, we attempted to elucidate the optimal screw position in the lateral lumbar vertebra and the effect of bicortical fixation. A total of 72 fresh-frozen lumbar vertebrae from L1-6 were harvested from 12 mature pigs and randomly assigned to two modalities: bicortical fixation (n = 36) and unicortical fixation (n = 36). Six groups of screw positions in the lateral vertebral body in each modality were designated as central-anterior, central-middle, central-posterior, lower-anterior, lower-middle, and lower- posterior; 6 specimens were used in each group. The correlations between screw fixation modalities, screw positions and axial pullout strength were analyzed. An appropriate screw trajectory and insertional depth were confirmed using axial and sagittal X-ray imaging prior to pullout testing. In both bicortical and unicortical fixation modalities, the screw pullout force was significantly higher in the posterior or middle position than in the anterior position (p < 0.05), and there was no significant differences between the central and lower positions. The maximal pullout forces from the same screw positions in unicortical fixation modalities were all significantly lower, decreases that ranged from 32.7 to 74%, than those in bicortical fixation modalities. Our study using porcine vertebrae showed that screws in the middle or posterior position of the lateral vertebral body had a higher pullout performance than those in the anterior position. Posteriorly positioned lateral vertebral screws with unicortical fixation provided better stability than anteriorly positioned screws with bicortical fixation.


Asunto(s)
Tornillos Óseos , Fusión Vertebral , Porcinos , Animales , Cadáver , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Radiografía , Fenómenos Biomecánicos
11.
Front Bioeng Biotechnol ; 11: 1182265, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37324423

RESUMEN

Ball-and-socket designs of cervical total disc replacement (TDR) have been popular in recent years despite the disadvantages of polyethylene wear, heterotrophic ossification, increased facet contact force, and implant subsidence. In this study, a non-articulating, additively manufactured hybrid TDR with an ultra-high molecular weight polyethylene core and polycarbonate urethane (PCU) fiber jacket, was designed to mimic the motion of normal discs. A finite element (FE) study was conducted to optimize the lattice structure and assess the biomechanical performance of this new generation TDR with an intact disc and a commercial ball-and-socket Baguera®C TDR (Spineart SA, Geneva, Switzerland) on an intact C5-6 cervical spinal model. The lattice structure of the PCU fiber was constructed using the Tesseract or the Cross structures from the IntraLattice model in the Rhino software (McNeel North America, Seattle, WA) to create the hybrid I and hybrid II groups, respectively. The circumferential area of the PCU fiber was divided into three regions (anterior, lateral and posterior), and the cellular structures were adjusted. Optimal cellular distributions and structures were A2L5P2 in the hybrid I and A2L7P3 in the hybrid II groups. All but one of the maximum von Mises stresses were within the yield strength of the PCU material. The range of motions, facet joint stress, C6 vertebral superior endplate stress and path of instantaneous center of rotation of the hybrid I and II groups were closer to those of the intact group than those of the Baguera®C group under 100 N follower load and pure moment of 1.5 Nm in four different planar motions. Restoration of normal cervical spinal kinematics and prevention of implant subsidence could be observed from the FE analysis results. Superior stress distribution in the PCU fiber and core in the hybrid II group revealed that the Cross lattice structure of a PCU fiber jacket could be a choice for a next-generation TDR. This promising outcome suggests the feasibility of implanting an additively manufactured multi-material artificial disc that allows for better physiological motion than the current ball-and-socket design.

12.
Front Bioeng Biotechnol ; 11: 1151627, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37214307

RESUMEN

Intraoperative pedicle screw depth adjustment after initial insertion, including both forward and backward adjustments, is sometimes necessary to facilitate rod application and ensure that the screw is in the correct position, which is determined by intraoperative fluoroscopy. Adjusting the screw with forward turns has no negative influence on the screw fixation stability; however, screw turnback may weaken the fixation stability. The aim of this study is to evaluate the biomechanical properties of screw turnback and demonstrate the reduction in the fixation stability after the screw is turned 360° from its full insertion position. Commercially available synthetic closed-cell polyurethane foams with three different densities simulating various degrees of bone density were utilized as substitutes for human bone. Two different screw shapes (cylindrical and conical) together with two different pilot hole profiles (cylindrical and conical) were tested. Following specimen preparation, screw pullout tests were conducted using a material test machine. The mean maximal pullout strength between full insertion and 360-degree turnback from full insertion in each setting was statistically analyzed. The mean maximal pullout strength after 360-degree turnback from full insertion was generally lower than that at full insertion. The reduced mean maximal pullout strength after turnback increased with decreasing bone density. Conical screws had significantly lower pullout strength after 360-degree turnback than cylindrical screws. The mean maximal pullout strength was reduced by up to approximately 27% after 360-degree turnback when using a conical screw in a low bone density specimen. Additionally, specimens treated with a conical pilot hole presented a less reduction in pullout strength after screw turnback as compared to those with a cylindrical pilot hole. The strength of our study was that we systematically investigated the effects of various bone densities and screw shapes on screw stability after turnback, which has rarely been reported in the literature. Our study suggests that pedicle screw turnback after full insertion should be reduced in spinal surgeries, particularly procedures that use conical screws in osteoporotic bone. Pedicle screw secured with a conical pilot hole might be beneficial for screw adjustment.

13.
BMC Musculoskelet Disord ; 13: 198, 2012 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-23072273

RESUMEN

BACKGROUND: Polymethylmethacrylate (PMMA) is commonly used for clinical applications. However, the short handling time increases the probability of a surgeon missing the crucial period in which the cement maintains its ideal viscosity for a successful injection. The aim of this article was to illustrate the effects a reduction in temperature would have on the cement handling time during percutaneous vertebroplasty. METHODS: The injectability of bone cement was assessed using a cement compressor. By twisting the compressor, the piston transmits its axial load to the plunger, which then pumps the bone cement out. The experiments were categorized based on the different types of hypothermic manipulation that were used. In group I (room temperature, sham group), the syringes were kept at 22°C after mixing the bone cement. In group 2 (precooling the bone cement and the container), the PMMA powder and liquid, as well as the beaker, spatula, and syringe, were stored in the refrigerator (4°C) overnight before mixing. In group 3 (ice bath cooling), the syringes were immediately submerged in ice water after mixing the bone cement at room temperature. RESULTS: The average liquid time, paste time, and handling time were 5.1 ± 0.7, 3.4 ± 0.3, and 8.5 ± 0.8 min, respectively, for group 1; 9.4 ± 1.1, 5.8 ± 0.5, and 15.2 ± 1.2 min, respectively, for group 2; and 83.8 ± 5.2, 28.8 ± 6.9, and 112.5 ± 11.3 min, respectively, for group 3. The liquid and paste times could be increased through different cooling methods. In addition, the liquid time (i.e. waiting time) for ice bath cooling was longer than for that of the precooling method (p < 0.05). CONCLUSIONS: Both precooling (i.e. lowering the initial temperature) and ice bath cooling (i.e. lowering the surrounding temperature) can effectively slow polymerization. Precooling is easy for clinical applications, while ice bath cooling might be more suitable for multiple-level vertebroplasty. Clinicians can take advantage of the improved injectability without any increased cost.


Asunto(s)
Cementos para Huesos/síntesis química , Química Farmacéutica/métodos , Frío , Vertebroplastia/métodos , Humanos , Hipotermia/cirugía , Polimetil Metacrilato/administración & dosificación , Polimetil Metacrilato/síntesis química , Factores de Tiempo , Vertebroplastia/instrumentación
14.
J Mech Behav Biomed Mater ; 134: 105366, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35870229

RESUMEN

Pedicle screw fixation is one of the most common procedures used in spinal fusion surgery. The screw loosening is a major concern, which may be caused by broken pedicles. In vitro pullout tests or insertion torque are the main approaches for assessing the stability of the screw; however, direct evidence was lacking for clinical human spines. Here, we aim to provide a model that can predict the pullout strengths of pedicle screws in various pedicle conditions from X-ray images. A weighted embedded bone volume (EBV) model is proposed for pullout strengths prediction by considering the bone heterogeneity and confinement of the screw. We showed that the pullout strength is proportional to the EBV for homogeneous bone and the weighted EBV for layered composite bone. The proposed weighted EBV model is validated with in vitro Sawbones® pullout experiments. The results show that the model has better accuracy than the simple EBV model, with a coefficient of determination of 0.94. The proposed weighted EBV model can help assess the stability of a pedicle screw in a broken pedicle by simply examining 2D X-ray images.


Asunto(s)
Fracturas Óseas , Tornillos Pediculares , Fusión Vertebral , Fenómenos Biomecánicos , Humanos , Fusión Vertebral/métodos , Torque , Rayos X
15.
Sci Rep ; 12(1): 414, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-35013540

RESUMEN

Osteoporosis is a critical problem during aging. Ultrasound signals backscattered from bone contain information associated with microstructures. This study proposed using entropy imaging to collect the information in bone microstructures as a possible solution for ultrasound bone tissue characterization. Bone phantoms with different pounds per cubic foot (PCF) were used for ultrasound scanning by using single-element transducers of 1 (nonfocused) and 3.5 MHz (nonfocused and focused). Clinical measurements were also performed on lumbar vertebrae (L3 spinal segment) in participants with different ages (n = 34) and postmenopausal women with low or moderate-to-high risk of osteoporosis (n = 50; identified using the Osteoporosis Self-Assessment Tool for Taiwan). The signals backscattered from the bone phantoms and subjects were acquired for ultrasound entropy imaging by using sliding window processing. The independent t-test, one-way analysis of variance, Spearman correlation coefficient rs, and the receiver operating characteristic (ROC) curve were used for statistical analysis. The results indicated that ultrasound entropy imaging revealed changes in bone microstructures. Using the 3.5-MHz focused ultrasound, small-window entropy imaging (side length: one pulse length of the transducer) was found to have high performance and sensitivity in detecting variation among the PCFs (rs = - 0.83; p < 0.05). Small-window entropy imaging also performed well in discriminating young and old participants (p < 0.05) and postmenopausal women with low versus moderate-to-high osteoporosis risk (the area under the ROC curve = 0.80; cut-off value = 2.65; accuracy = 86.00%; sensitivity = 71.43%; specificity = 88.37%). Ultrasound small-window entropy imaging has great potential in bone tissue characterization and osteoporosis assessment.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Ultrasonografía , Adulto , Factores de Edad , Anciano , Densidad Ósea , Entropía , Estudios de Factibilidad , Femenino , Humanos , Vértebras Lumbares/fisiopatología , Persona de Mediana Edad , Osteoporosis/fisiopatología , Osteoporosis Posmenopáusica/diagnóstico por imagen , Osteoporosis Posmenopáusica/fisiopatología , Fantasmas de Imagen , Porosidad , Posmenopausia , Valor Predictivo de las Pruebas , Dispersión de Radiación , Ultrasonografía/instrumentación
16.
Sci Rep ; 12(1): 2739, 2022 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-35177724

RESUMEN

Polymethylmethacrylate (PMMA) has been applied clinically and biomechanically repair loose pedicle screws. Controversies have arisen over data due to uncontrolled cement properties, various locations and sizes of fenestrated holes in repair screws, irregular holes and different bone densities of specimens. In this study, the pullout strength was compared for two techniques, the modified technique to use PMMA to augment a threaded hole and the traditional technique with retrograde injection of a PMMA filling, for standard loose screws in porcine vertebrae. Both techniques provided statistically significant results for sufficiently randomized specimens and experimental procedures. The difference in the pullout strength between conical and cylindrical screws for the aforementioned cement augmentation techniques was also investigated. Twenty-four single-level fresh-frozen lumbar vertebrae from L1 to L6 were harvested from four mature pigs. A total of 0.8 ml of PMMA was retrograde injected into screw holes with a 5.5 mm diameter, followed by insertion of a 5.0 mm diameter repair screw in the traditional group (n = 12). A stiff threaded PMMA hole was created with a 4.5 mm tapping screw before insertion of repair screws in the modified group (n = 12). Two screw geometries were randomly assigned as cylindrical (n = 6) and conical (n = 6) in each group. The correlations between filling techniques, screw geometries and axial pullout strength were analyzed. An appropriate screw trajectory and insertion depth were confirmed using X-ray imaging prior to pullout testing in both groups. For a given screw geometry (cylindrical or conical), the pullout force of the modified group was significantly higher than that of the traditional group. There was no significant difference in the pullout force between the screw geometries for a given filling technique. The cement augmentation technique is far more influential than the screw outer geometry. The modified PMMA technique created a greater anchor force than the traditional method and could be an alternative for revision of pedicle screw loosening.


Asunto(s)
Cementos para Huesos/farmacología , Vértebras Lumbares/cirugía , Tornillos Pediculares , Animales , Porcinos
17.
Front Bioeng Biotechnol ; 10: 1054738, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36568298

RESUMEN

Three key factors are responsible for the biomechanical performance of pedicle screw fixation: screw mechanical characteristics, bone quality and insertion techniques. To the best of the authors' knowledge, no study has directly compared the biomechanical performance among three trajectories, i.e., the traditional trajectory (TT), modified trajectory (MT) and cortical bone trajectory (CBT), in a porcine model. This study compared the pullout strength and insertion torque of three trajectory methods in single vertebrae, the pullout strength and fixation stiffness including flexion, extension, and lateral bending in a one-level instrumented functional spinal unit (FSU) that mimics the in vivo configuration were clarified. A total of 18 single vertebrae and 18 FSUs were randomly assigned into three screw insertion methods (n = 6 in each trajectory group). In the TT group, the screw converged from its entry point, passed completely inside the pedicle, was parallel to the superior endplate, was located in the superior third of the vertebral body and reached to at least the anterior third of the vertebral body. In the MT group, the convergent angle was similar to that of the TT method but directed caudally to the anterior inferior margin of the vertebral body. The results of insertion torque and pullout strength in single vertebrae were analyzed; in addition, the stiffness and pullout strength in the one-level FSU were also investigated. This study demonstrated that, in single vertebrae, the insertion torque was significantly higher in CBT groups than in TT and MT groups (p < 0.05). The maximal pullout strength was significantly higher in MT groups than in TT and CBT groups (p < 0.05). There was no significant difference in stiffness in the three motions among all groups. The maximal pullout strength in FSUs of MT and CBT groups were significantly higher than the TT groups (p < 0.05). We concluded that either MT or CBT provides better biomechanical performance than TT in single vertebrae or FSUs. The lack of significance of stiffness in FSUs among three methods suggested that MT or CBT could be a reasonable alternative to TT if the traditional trajectory was not feasible.

18.
BMC Musculoskelet Disord ; 12: 116, 2011 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-21615939

RESUMEN

BACKGROUND: Percutaneous vertebroplasty by injecting PMMA bone cement into the fractured vertebrae has been widely accepted in treatment of spinal compression fracture. However, the exothermic polymerization of bone cement may cause osseous or neural tissue injury. This study is thus designed to evaluate the potential risk of thermal damage in percutaneous vertebroplasty. METHOD: Twelve porcine vertebrae were immersed in 37°C saline for the experiment. In the first stage of the study, vertebroplasty without cement leakage (control group, n = 6) was simulated. The anterior cortex, foramen, posterior cortex and the center of the vertebral body were selected for temperature measurement. Parameters including peak temperature and duration above 45°C were recorded. In the second stage, a model (n = 6) simulating bone cement leaking into the spinal canal was designed. The methods for temperature measurement were identical to those used in the first stage. RESULTS: In Stage 1 of the study (vertebroplasty of the porcine vertebral body in the absence of cement leakage), the average maximal temperature at the anterior cortex was 42.4 ± 2.2°C; at the neural foramen 39.5 ± 2.1°C; at the posterior cortex 40.0 ± 2.5°C and at the vertebral center, 68.1 ± 3.4°C. The average time interval above 45°C was 0 seconds at the anterior cortex; at the neural foramen, 0 seconds; at the posterior cortex, 0 seconds and at the vertebral center, 223 seconds. Thus, except at the core of the bone cement, temperatures around the vertebral body did not exceed 45°C. In Stage 2 of the study (cement leakage model), the average maximal temperature at the anterior cortex was 42.7 ± 2.4°C; at the neural foramen, 41.1 ± 0.4°C; at the posterior cortex, 59.1 ± 7.6°C and at the vertebral center, 77.3 ± 5.7°C. The average time interval above 45°C at the anterior cortex was 0 seconds; at the neural foramen, 0 seconds; at the posterior cortex, 329.3 seconds and at the vertebral center, 393.2 seconds. Based on these results, temperatures exceeded 45°C at the posterior cortex and at the vertebral center. CONCLUSIONS: The results indicated that, for bone cement confined within the vertebra, curing temperatures do not directly cause thermal injury to the nearby soft tissue. If bone cement leaks into the spinal canal, the exothermic reaction at the posterior cortex might result in thermal injury to the neural tissue.


Asunto(s)
Temperatura Corporal/efectos de los fármacos , Cementos para Huesos/toxicidad , Vértebras Lumbares/efectos de los fármacos , Polimetil Metacrilato/toxicidad , Vértebras Torácicas/efectos de los fármacos , Vertebroplastia/efectos adversos , Animales , Cementos para Huesos/química , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Polimetil Metacrilato/química , Radiografía , Porcinos , Conductividad Térmica , Termografía , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/fisiopatología , Factores de Tiempo
19.
BMC Musculoskelet Disord ; 12: 33, 2011 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-21284883

RESUMEN

BACKGROUND: Pedicle screws with PMMA cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques, namely solid screws with retrograde cement pre-filling versus cannulated screws with cement injection through perforation, remains unknown. This study aimed to determine the difference in pullout strength between conical and cylindrical screws based on the aforementioned cement augmentation techniques. The potential loss of fixation upon partial screw removal after screw insertion was also examined. METHOD: The Taguchi method with an L8 array was employed to determine the significance of design factors. Conical and cylindrical pedicle screws with solid or cannulated designs were installed using two different screw augmentation techniques: solid screws with retrograde cement pre-filling and cannulated screws with cement injection through perforation. Uniform synthetic bones (test block) simulating severe osteoporosis were used to provide a platform for each screw design and cement augmentation technique. Pedicle screws at full insertion and after a 360-degree back-out from full insertion were then tested for axial pullout failure using a mechanical testing machine. RESULTS: The results revealed the following 1) Regardless of the screw outer geometry (conical or cylindrical), solid screws with retrograde cement pre-filling exhibited significantly higher pullout strength than did cannulated screws with cement injection through perforation (p = 0.0129 for conical screws; p = 0.005 for cylindrical screws). 2) For a given cement augmentation technique (screws without cement augmentation, cannulated screws with cement injection or solid screws with cement pre-filling), no significant difference in pullout strength was found between conical and cylindrical screws (p >0.05). 3) Cement infiltration into the open cell of the test block led to the formation of a cement/bone composite structure. Observations of the failed specimens indicated that failure occurred at the composite/bone interface, whereas the composite remained well bonded to the screws. This result implies that the screw/composite interfacial strength was much higher than the composite/bone interfacial strength. 4) The back-out of the screw by 360 degrees from full insertion did not decrease the pullout strength in any of the studied cases. 5) Generally, larger standard deviations were found for the screw back-out cases, implying that the results of full insertion cases are more repeatable than those of the back-out cases. CONCLUSIONS: Solid screws with retrograde cement pre-filling offer improved initial fixation strength when compared to that of cannulated screws with cement injection through perforation for both the conically and cylindrically shaped screw. Our results also suggest that the fixation screws can be backed out by 360 degrees for intra-operative adjustment without the loss of fixation strength.


Asunto(s)
Cementos para Huesos/uso terapéutico , Tornillos Óseos/normas , Osteoporosis/cirugía , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoporosis/diagnóstico por imagen , Osteoporosis/patología , Radiografía , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Enfermedades de la Columna Vertebral/patología , Fusión Vertebral/instrumentación
20.
J Trauma ; 68(4): 965-9, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19996806

RESUMEN

BACKGROUND: Septic arthritis in native hip joints is a rare but serious condition in adult patients. Prompt aggressive surgical and medical treatment is a challenge, and the outcomes after delayed management can be devastating. This article reports the findings of treatment of recalcitrant cases using a standardized protocol. METHODS: Fourteen consecutive patients (15 hips) were treated with two-stage total hip arthroplasty (THA) for septic arthritis of the hip joint over a 6-year period. All patients underwent resection arthroplasty and implantation of an antibiotic-loaded articulating spacer in the first stage, short-term systemic antibiotic therapy during the interim period, and subsequent THA without bone cement in the second stage. RESULTS: One patient required additional debridement and spacer reinsertion before THA. The mean interim period was 12.9 weeks (range, 6-31 weeks). After an average follow-up period of 42.5 months (range, 25-72 months) after THA, there was no evidence of recurrent infection or loosening of the prostheses in any patient. The average Merle D'Aubigne and Postel hip score improved from 9.3 (range, 5-15) to 13.5 (range, 12-16) between stages and to 16.7 (range, 15-18) at the latest follow-up. CONCLUSIONS: Two-stage uncemented THA is a reliable treatment option for adult patients with recalcitrant septic hips. If an antibiotic-loaded interim spacer is used, routine, prolonged systemic antibiotic therapy may not be necessary.


Asunto(s)
Antibacterianos/administración & dosificación , Artritis Infecciosa/tratamiento farmacológico , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Osteoartritis de la Cadera/tratamiento farmacológico , Osteoartritis de la Cadera/cirugía , Adulto , Anciano , Terapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/prevención & control , Resultado del Tratamiento