1.
ASAIO J ; 66(1): 64-68, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30507849

RESUMEN

Implantable continuous-flow left ventricular assist devices (CF-LVADs) are used for long-term LV support in bridging patients to heart transplantation or as destination therapy. With prolonged support times, some patients will have repeat complications necessitating multiple device exchanges. To elucidate the safety and efficacy of repeat device exchange, we retrospectively reviewed data from 25 patients who underwent two or more CF-LVAD implantations between July 2005 and August 2017. Indications for exchange were thrombus/hemolysis (n = 8, 32%), electromechanical device malfunction (n = 14, 56%), and infection (n = 3, 12%). The implanted devices were the HeartMate II (n = 13, 52%), the HeartWare HVAD (n = 11, 44%), and the Jarvik 2000 (n = 1, 4%). Average hospital length of stay was 44 days (range 4-221 days), and 17 patients (68%) survived to discharge. Average duration of support after the most recent LVAD implantation was 802 days (range 1-3,229 days). Overall survival was 72% at 1 year and 60% at 2 years. Postoperative complications included respiratory failure in five patients (20%), device infection in five (20%), bleeding requiring reoperation in four (16%), neurologic dysfunction in four (16%), and acute renal failure in two (8%). Overall, our data suggest that repeat LVAD exchange is a feasible option for patients with recurrent device-related complications.


Asunto(s)
Corazón Auxiliar , Reoperación/mortalidad , Adolescente , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Reoperación/efectos adversos , Reoperación/métodos , Estudios Retrospectivos , Adulto Joven
2.
ASAIO J ; 64(4): e75-e77, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29135479

RESUMEN

The temporary total artificial heart (TAH-t) has been valuable as a bridge to transplantation in patients with biventricular failure. However, the challenges of accurately assessing pulmonary vascular resistance after TAH-t implantation can preclude these patients from heart transplantation, especially those with pre-existing pulmonary hypertension. The CardioMEMS Heart Failure System (St. Jude's Medical, Little Canada, MN) comprises a wireless pressure sensor that is implanted percutaneously in the pulmonary artery and transmits real-time measurements of pulmonary artery pressures. Systolic and diastolic pulmonary artery (PA) pressures measurements have been well correlated between the CardioMEMS PA Sensor and traditional Swan-Ganz catheter and between the CardioMEMS PA Sensor and standard echocardiography. Here, we report the use of the CardioMEMS device in a patient with severe pulmonary hypertension supported with a SynCardia TAH-t (Tucson, AZ) during assessment for candidacy for transplantation.


Asunto(s)
Monitores de Presión Sanguínea , Trasplante de Corazón , Corazón Artificial , Transductores de Presión , Resistencia Vascular , Hemodinámica , Humanos , Hipertensión Pulmonar/fisiopatología , Masculino , Prótesis e Implantes , Arteria Pulmonar/fisiopatología , Adulto Joven