Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
6.
Diagnostics (Basel) ; 11(10)2021 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-34679556

RESUMEN

BACKGROUND: Pancreatic cancer (PC) exhibits extremely rapid growth; however, it remains largely unknown whether the early stages of PC also exhibit rapid growth speed equivalent to advanced PC. This study aimed to investigate the natural history of early PCs through retrospectively assessing pre-diagnostic images. METHODS: We examined the data of nine patients, including three patients with carcinoma in situ (CIS), who had undergone magnetic resonance cholangiopancreatography (MRCP) to detect solitary main pancreatic duct (MPD) stenosis >1 year before definitive PC diagnosis. We retrospectively analyzed the time to diagnosis and first-time tumor detection from the estimated time point of first-time MPD stenosis detection without tumor lesion. RESULTS: The median tumor size at diagnosis and the first-time tumor detection size were 14 and 7.5 mm, respectively. The median time to diagnosis and first-time tumor detection were 26 and 49 months, respectively. CONCLUSIONS: No studies have investigated the PC history, especially that of early PCs, including CIS, based on the initial detection of MPD stenosis using MRCP. Assessment of a small number of patients showed that the time to progression can take several years in the early PC stages. Understanding this natural history is very important in the clinical setting.

7.
World J Gastrointest Pharmacol Ther ; 12(4): 79-89, 2021 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-34316385

RESUMEN

BACKGROUND: Preparation for colon capsule endoscopy (CCE) requires a large liquid laxative volume for capsule excretion, which compromises the procedure's tolerability. AIM: To assess the safety and utility of castor oil-boosted bowel preparation. METHODS: This prospective cohort study including 20 patients (age range, 16-80 years; six men and 14 women) suspected of having colorectal disease was conducted at Kindai University Hospital from September 2017 to August 2019. All patients underwent CCE because of the following inclusion criteria: previous incomplete colonoscopy in other facility (n = 20), history of abdominal surgery (n = 7), or organ abnormalities such as multiple diverticulum (n = 4) and adhesion after surgery (n = 6). The exclusion criteria were as follows: Dysphagia, history of allergic reactions to the drugs used in this study (magnesium citrate, polyethylene glycol, metoclopramide, and castor oil), possibility of pregnancy, possibility of bowel obstruction or stenosis based on symptoms, or scheduled magnetic resonance imaging within 2 wk after CCE. The primary outcome was the capsule excretion rate within the battery life, as evaluated by the total large bowel observation rate, large bowel transit time, and bowel creasing level using a five-grade scale in different colorectal segments. The secondary outcomes were complications, colorectal lesion detection rates, and patients' tolerability. RESULTS: The castor oil-based regimen was implemented in 17 patients. Three patients cancelled CCE because they could tolerate castor oil, but not liquid laxatives. The capsule excretion rate within the battery life was 88% (15/17). The mean large bowel transit time was 236 min. Approximately 70% of patients had satisfactory colon cleansing levels. CCE detected colon polyps (14/17, 82%) and colonic diverticulum (4/12, 33%). The sensitivity, specificity, and diagnostic accuracy rates for detecting colorectal polyps (size ≥ 6 mm) were 76.9%, 75.0%, and 76.4%, respectively. The sensitivity, specificity, and diagnostic accuracy rates for detection of diverticulum were 100% each. Twelve patients (71%) rated CCE as more than "good", confirming the new regimen's tolerability. No serious adverse events occurred during this study. CONCLUSION: The castor oil-based regimen could reduce bowel preparation dose and improve CCE tolerability.

8.
J Clin Med ; 10(13)2021 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-34203200

RESUMEN

Unsuccessful stent replacement in transpapillary biliary drainage with plastic stents (PSs) has a significant impact on patient prognosis; thus, a safe and reliable replacement method is required. We aimed to compare the snare-over-the-guidewire (SOG) method, wherein the PS lumen is used as an access route to the biliary tract and the PS is removed with a snare inserted via the inserted guidewire, with the conventional side-of-stent (SOS) method, wherein the biliary approach is performed from the side of the PS. This retrospective single-center study included 244 consecutive patients who underwent biliary PS replacement between January 2018 and July 2020. The procedural success rates were compared between the two methods. A predictive analysis of unsuccessful PS replacement was also performed. The procedural success rate in the SOG group was significantly higher than that in the SOS group (p = 0.026). In the proximal biliary stenosis lesion, the same trend was observed (p = 0.025). Multivariate analysis also showed that the SOS method (p = 0.0038), the presence of proximal biliary stenosis (p < 0.0001), and parapapillary diverticulum (p = 0.0007) were predictors of unsuccessful PS replacement. The SOG method may be useful for biliary PS replacement, especially in cases of proximal hilar bile duct stenosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA