Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Heart Vessels ; 35(4): 451-462, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31562554

RESUMEN

Cholesterol crystals (CCs) are frequently found in high-risk plaques, such as thin-capped fibroatheromas. The purpose of this study was to investigate the associations of CCs, plaque morphologies, and post-stent optical frequency domain imaging (OFDI) findings with periprocedural cardiac troponin (cTn) elevation in patients treated with percutaneous coronary intervention (PCI). This study consists of 119 patients with stable coronary artery disease (CAD) with normal cTn levels who underwent OFDI-guided PCI. Periprocedural cTn elevation was defined as an elevation of cTn ≥ × 5 times the upper reference limit after PCI. Pre- and post-stent OFDI findings, including fibrous cap thickness (FCT), presence of CCs, and parameters for lipid and calcification were analyzed. A total of 37 (31%) patients were classified into the periprocedural cTn elevation group. Compared with lesions without CCs, lesions exhibiting CCs had thinner FCT, larger lipid arc, and longer lipid length, and were more likely to have irregular protrusion and in-stent thrombus (all p < 0.05). For pre-stent OFDI features, FCT < 82 µm [odds ratio (OR) 4.11; p = 0.003] and CCs (OR 3.23; p = 0.017) were associated with periprocedural cTn elevation. For post-stent OFDI features, in-stent dissection (OR 3.08; p = 0.035) and in-stent thrombus (OR 7.98; p = 0.002) were independent predictors of cTn elevation. The combination of CCs and FCT < 82 µm showed increased risk of periprocedural cTn elevation (OR 7.22; p = 0.002). OFDI-guided PCI provides unique insight into the mechanism for periprocedural cTn elevation in CAD patients.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Intervención Coronaria Percutánea , Placa Aterosclerótica/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/sangre , Placa Aterosclerótica/cirugía , Pronóstico , Stents , Troponina I/sangre
2.
Heart Vessels ; 34(5): 735-744, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30386919

RESUMEN

Renal dysfunction and its change pattern are associated with short- and long-term mortality. However, it remains to be investigated whether or not worsening renal function (WRF) defined by baseline renal function identified from different time points would provide prognostic implication on outcomes in acute coronary syndrome (ACS) patients. This study consists of 334 ACS patients (mean age 68 ± 11 years, 75% male) treated with emergent percutaneous coronary intervention (PCI). Estimated glomerular filtration rate (eGFR) was evaluated on baseline, during hospitalization, at discharge, and at 3-month follow-up. WRF was defined as a relative decrease of eGFR > 20% at 3 months using baseline eGFR identified from different time points. The primary end point was a composite event of major cardiovascular events (MACE), including all-cause death, ACS, and heart failure hospitalization. The associations of chronic kidney disease (CKD), acute kidney injury (AKI), and WRF with MACE were evaluated. During a mean follow-up of 3.3 ± 1.7 years, a total of 64 MACE were observed. Multivariable analysis revealed that CKD (hazard ratio 2.16; p = 0.018) and AKI (hazard ratio 1.95; p = 0.030) were independent predictors of MACE, but WRF did not remain as an independent predictor of MACE (p = 0.208). The highest risk was observed in AKI patients with CKD when stratified by the presence or absence of CKD and AKI. In ACS patients treated with emergent PCI, this study demonstrated that CKD and AKI were independent predictors of MACE, while there was no independent relationship between WRF and MACE.


Asunto(s)
Síndrome Coronario Agudo/fisiopatología , Riñón/fisiopatología , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica/etiología , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/cirugía , Lesión Renal Aguda/etiología , Anciano , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Hospitalización , Humanos , Japón , Masculino , Persona de Mediana Edad , Mortalidad , Análisis Multivariante , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Análisis de Supervivencia , Función Ventricular Izquierda
3.
Osaka City Med J ; 59(2): 69-78, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24575582

RESUMEN

BACKGROUND: Bicuspid aortic valve (BAV) is associated with an increased risk of aortic valve (AV) dysfunction, aortic dissection, and infective endocarditis. Therefore, its accurate diagnosis is critical. The morphological features of AVs are generally evaluated by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE), however, the difference in the diagnostic capability of these imaging modalities for detecting BAV remains unclear. Here, we compared these 2 methods to determine their accuracy, and to clarify each role in the diagnosis of BAV. METHODS: This blind study evaluated 126 patients (age, 70.3 +/- 7.8 years) who subsequently underwent AV replacement. The number of AV cusps of each patient was estimated by TTE and TEE and compared to the number of AV written in the operative record. Patients with poor echocardiographic images were not excluded. RESULTS: Surgical findings showed 97 tricuspid AVs and 29 BAVs. The sensitivity, specificity, and accuracy for the diagnosis of BAV were 61%, 81%, and 77%, respectively, for TTE and 86%, 90%, and 89%, respectively, for TEE. The accuracy of TEE was significantly higher than that of TTE (p = 0.016). In non-calcified AVs, the accuracy of TTE was similar to that of TEE (96%, each) whereas in calcified AVs, TTE had a lower accuracy than TEE (72% vs 87%, p = 0.011). The feasibility was significantly higher for TEE than for TTE (98% vs 90%, p = 0.003). CONCLUSIONS: TEE provides higher accuracy and feasibility than TTE in the diagnosis of BAV, and it should therefore be indicated when morphological features of AVs cannot be evaluated by TTE.


Asunto(s)
Válvula Aórtica/anomalías , Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Enfermedades de las Válvulas Cardíacas/patología , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad
4.
Am J Cardiol ; 110(1): 93-7, 2012 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-22497679

RESUMEN

Recently, an aortic valve area (AVA) index (AVAI) <0.6 cm(2)/m(2) was proposed as an indicator of severe aortic stenosis. The purpose of the present study was to clarify the prognostic value of the AVAI. We identified 103 consecutive asymptomatic patients (mean age 72 ± 11 years) with severe aortic stenosis, defined by an AVA of <1.0 cm(2), who had not undergone aortic valve replacement on initial evaluation. During follow-up (median 36 ± 27 months), 31 aortic valve replacements and 20 cardiac deaths occurred. Multivariate analysis revealed that an AVAI <0.6 cm(2)/m(2) (hazard ratio 2.6, 95% confidence interval 1.1 to 6.3; p = 0.03) and peak aortic jet velocity (Vp) >4.0 m/s (hazard ratio 2.6, 95% confidence interval 1.2 to 5.8; p = 0.02) were associated with cardiac events but that an AVA <0.75 cm(2) was not. The event-free survival of patients with an AVAI of ≥0.6 cm(2)/m(2) was better than that for those with an AVAI <0.6 cm(2)/m(2) (86% vs 41% at 3 years, p <0.01). Furthermore, patients with an AVAI of ≥0.6 cm(2)/m(2) and Vp of ≤4.0 m/s showed an excellent prognosis, but those without these findings had poorer outcomes. In conclusion, AVAI is a powerful predictor of adverse events in asymptomatic patients with severe aortic stenosis. Furthermore, the combination of AVAI and Vp provides additional prognostic information. Watchful observations are required for timely aortic valve replacement in patients with an AVAI of <0.6 cm(2)/m(2) or a Vp >4.0 m/s.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía/métodos , Anciano , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Japón/epidemiología , Masculino , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA