Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 34(2): 1065-1076, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37580601

RESUMEN

OBJECTIVE: The purpose of this study was thus to compare capabilities for quantitative differentiation of non- and minimally invasive adenocarcinomas from other of pulmonary MRIs with ultra-short TE (UTE) obtained with single- and dual-echo techniques (UTE-MRISingle and UTE-MRIDual) and thin-section CT for stage IA lung cancer patients. METHODS: Ninety pathologically diagnosed stage IA lung cancer patients who underwent thin-section standard-dose CT, UTE-MRISingle, and UTE-MRIDual, surgical treatment and pathological examinations were included in this retrospective study. The largest dimension (Dlong), solid portion (solid Dlong), and consolidation/tumor (C/T) ratio of each nodule were assessed. Two-tailed Student's t-tests were performed to compare all indexes obtained with each method between non- and minimally invasive adenocarcinomas and other lung cancers. Receiver operating characteristic (ROC)-based positive tests were performed to determine all feasible threshold values for distinguishing non- or minimally invasive adenocarcinoma (MIA) from other lung cancers. Sensitivity, specificity, and accuracy were then compared by means of McNemar's test. RESULTS: Each index showed significant differences between the two groups (p < 0.0001). Specificities and accuracies of solid Dlong for UTE-MRIDual2nd echo and CTMediastinal were significantly higher than those of solid Dlong for UTE-MRISingle and UTE-MRIDual1st echo and all C/T ratios except CTMediastinal (p < 0.05). Moreover, the specificities and accuracies of solid Dlong and C/T ratio were significantly higher than those of Dlong for each method (p < 0.05). CONCLUSION: Pulmonary MRI with UTE is considered at least as valuable as thin-section CT for quantitative differentiation of non- and minimally invasive adenocarcinomas from other stage IA lung cancers. CLINICAL RELEVANCE STATEMENT: Pulmonary MRI with UTE's capability for quantitative differentiation of non- and minimally invasive adenocarcinomas from other lung cancers in stage IA lung cancer patients is equal or superior to that of thin-section CT. KEY POINTS: • Correlations were excellent for pathologically examined nodules with the largest dimensions (Dlong) and a solid component (solid Dlong) for all indexes (0.95 ≤ r ≤ 0.99, p < 0.0001). • Pathologically examined Dlong and solid Dlong obtained with all methods showed significant differences between non- and minimally invasive adenocarcinomas and other lung cancers (p < 0.0001). • Solid tumor components are most accurately measured by UTE-MRIDual2nd echo and CTMediastinal, whereas the ground-glass component is imaged by UTE-MRIDual1st echo and CTlung with high accuracy. UTE-MRIDual predicts tumor invasiveness with 100% sensitivity and 87.5% specificity at a C/T threshold of 0.5.


Asunto(s)
Adenocarcinoma , Enfermedades Pulmonares , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/patología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Pulmón/patología , Adenocarcinoma/patología , Imagen por Resonancia Magnética/métodos
2.
J Magn Reson Imaging ; 58(1): 174-186, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36971493

RESUMEN

BACKGROUND: Amide proton transfer (APT) weighted chemical exchange saturation transfer CEST (APTw/CEST) magnetic resonance imaging (MRI) has been suggested as having the potential for assessing the therapeutic effect of brain tumors or rectal cancer. Moreover, diffusion-weighted imaging (DWI) and positron emission tomography fused with computed tomography by means of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG-PET/CT) have been suggested as useful in same setting. PURPOSE: To compare the capability of APTw/CEST imaging, DWI, and FDG-PET/CT for predicting therapeutic effect of chemoradiotherapy (CRT) on stage III non-small cell lung cancer (NSCLC) patients. STUDY TYPE: Prospective. POPULATION: Eighty-four consecutive patients with Stage III NSCLC, 45 men (age range, 62-75 years; mean age, 71 years) and 39 women (age range, 57-75 years; mean age, 70 years). All patients were then divided into two groups (Response Evaluation Criteria in Solid Tumors [RECIST] responders, consisting of the complete response and partial response groups, and RECIST non-responders, consisting of the stable disease and progressive disease groups). FIELD STRENGTH/SEQUENCE: 3 T, echo planar imaging or fast advanced spin-echo (FASE) sequences for DWI and 2D half Fourier FASE sequences with magnetization transfer pulses for CEST imaging. ASSESSMENT: Magnetization transfer ratio asymmetry (MTRasym ) at 3.5 ppm, apparent diffusion coefficient (ADC), and maximum standard uptake value (SUVmax, ) on PET/CT were assessed by means of region of interest (ROI) measurements at primary tumor. STATISTICAL TESTS: Kaplan-Meier method followed by log-rank test and Cox proportional hazards regression analysis with multivariate analysis. A P value <0.05 was considered statistically significant. RESULTS: Progression-free survival (PFS) and overall survival (OS) had significant difference between two groups. MTRasym at 3.5 ppm (hazard ratio [HR] = 0.70) and SUVmax (HR = 1.41) were identified as significant predictors for PFS. Tumor staging (HR = 0.57) was also significant predictors for OS. DATA CONCLUSION: APTw/CEST imaging showed potential performance as DWI and FDG-PET/CT for predicting the therapeutic effect of CRT on stage III NSCLC patients. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/patología , Fluorodesoxiglucosa F18 , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Quimioradioterapia , Radiofármacos
3.
J Magn Reson Imaging ; 57(1): 259-272, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35753082

RESUMEN

BACKGROUND: Computed diffusion-weighted imaging (cDWI) is a mathematical computation technique that generates DWIs for any b-value by using actual DWI (aDWI) data with at least two different b-values and may improve differentiation of metastatic from nonmetastatic lymph nodes. PURPOSE: To determine the appropriate b-value for cDWI to achieve a better diagnostic capability for lymph node staging (N-staging) in non-small cell lung cancer (NSCLC) patients compared to aDWI, short inversion time (TI) inversion recovery (STIR) imaging, or positron emission tomography with 2-[fluorine-18] fluoro-2-deoxy-d-glucose combined with computed tomography (FDG-PET/CT). STUDY TYPE: Prospective. SUBJECTS: A total of 245 (127 males and 118 females; mean age 72 years) consecutive histopathologically confirmed NSCLC patients. FIELD STRENGTH/SEQUENCE: A 3 T, half-Fourier single-shot turbo spin-echo sequence, electrocardiogram (ECG)-triggered STIR fast advanced spin-echo (FASE) sequence with black blood and STIR acquisition and DWI obtained by FASE with b-values of 0 and 1000 sec/mm2 . ASSESSMENT: From aDWIs with b-values of 0 and 1000 (aDWI1000 ) sec/mm2 , cDWI using 400 (cDWI400 ), 600 (cDWI600 ), 800 (cDWI800 ), and 2000 (cDWI2000 ) sec/mm2 were generated. Then, 114 metastatic and 114 nonmetastatic nodes (mediastinal and hilar lymph nodes) were selected and evaluated with a contrast ratio (CR) for each cDWI and aDWI, apparent diffusion coefficient (ADC), lymph node-to-muscle ratio (LMR) on STIR, and maximum standard uptake value (SUVmax ). STATISTICAL TESTS: Receiver operating characteristic curve (ROC) analysis, Youden index, and McNemar's test. RESULTS: Area under the curve (AUC) of CR600 was significantly larger than the CR400 , CR800 , CR2000 , aCR1000 , and SUVmax . Comparison of N-staging accuracy showed that CR600 was significantly higher than CR400 , CR2000 , ADC, aCR1000 , and SUVmax , although there were no significant differences with CR800 (P = 0.99) and LMR (P = 0.99). DATA CONCLUSION: cDWI with b-value at 600 sec/mm2 may have potential to improve N-staging accuracy as compared with aDWI, STIR, and PET/CT. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Masculino , Femenino , Humanos , Anciano , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Tomografía de Emisión de Positrones/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Desoxiglucosa , Fluorodesoxiglucosa F18 , Radiofármacos , Estadificación de Neoplasias
4.
Radiology ; 302(3): 697-706, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34846203

RESUMEN

Background Pulmonary MRI with ultrashort echo time (UTE) has been compared with chest CT for nodule detection and classification. However, direct comparisons of these methods' capabilities for Lung CT Screening Reporting and Data System (Lung-RADS) evaluation remain lacking. Purpose To compare the capabilities of pulmonary MRI with UTE with those of standard- or low-dose thin-section CT for Lung-RADS classification. Materials and Methods In this prospective study, standard- and low-dose chest CT (270 mA and 60 mA, respectively) and MRI with UTE were used to examine consecutive participants enrolled between January 2017 and December 2020 who met American College of Radiology Appropriateness Criteria for lung cancer screening with low-dose CT. Probability of nodule presence was assessed for all methods with a five-point visual scoring system by two board-certified radiologists. All nodules were then evaluated in terms of their Lung-RADS classification using each method. To compare nodule detection capability of the three methods, consensus for performances was rated by using jackknife free-response receiver operating characteristic analysis, and sensitivity was compared by means of the McNemar test. In addition, weighted κ statistics were used to determine the agreement between Lung-RADS classification obtained with each method and the reference standard generated from standard-dose CT evaluated by two radiologists who were not included in the image analysis session. Results A total of 205 participants (mean age: 64 years ± 7 [standard deviation], 106 men) with 1073 nodules were enrolled. Figure of merit (FOM) (P < .001) had significant differences among three modalities (standard-dose CT: FOM = 0.91, low-dose CT: FOM = 0.89, pulmonary MRI with UTE: FOM = 0.94), with no evidence of false-positive findings in participants with all modalities (P > .05). Agreements for Lung-RADS classification between all modalities and the reference standard were almost perfect (standard-dose CT: κ = 0.82, P < .001; low-dose CT: κ = 0.82, P < .001; pulmonary MRI with UTE: κ = 0.82, P < .001). Conclusion In a lung cancer screening population, ultrashort echo time pulmonary MRI was comparable to standard- or low-dose CT for Lung CT Screening Reporting and Data System classification. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Detección Precoz del Cáncer , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
AJR Am J Roentgenol ; 218(5): 899-908, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34877872

RESUMEN

BACKGROUND. Whole-body MRI and FDG PET/MRI have shown encouraging results for staging of thoracic malignancy but are poorly studied for staging of small cell lung cancer (SCLC). OBJECTIVE. The purpose of our study was to compare the performance of conventional staging tests, FDG PET/CT, whole-body MRI, and FDG PET/MRI for staging of SCLC. METHODS. This prospective study included 98 patients (64 men, 34 women; median age, 74 years) with SCLC who underwent conventional staging tests (brain MRI; neck, chest, and abdominopelvic CT; and bone scintigraphy), FDG PET/CT, and whole-body MRI within 2 weeks before treatment; coregistered FDG PET/MRI was generated. Two nuclear medicine physicians independently reviewed conventional tests and FDG PET/CT examinations in separate sessions, and two chest radiologists independently reviewed whole-body MRI and FDG PET/MRI examinations in separate sessions. Readers assessed T, N, and M categories; TNM stage; and Veterans Administration Lung Cancer Study Group (VALSG) stage. Reader pairs subsequently reached consensus. Stages determined clinically during tumor board sessions served as the reference standard. RESULTS. Accuracy for T category was higher (p < .05) for whole-body MRI (94.9%) and FDG PET/MRI (94.9%) than for FDG PET/CT (85.7%). Accuracy for N category was higher (p < .05) for whole-body MRI (84.7%), FDG PET/MRI (83.7%), and FDG PET/CT (81.6%) than for conventional staging tests (75.5%). Accuracy for M category was higher (p < .05) for whole-body MRI (94.9%), FDG PET/MRI (94.9%), and FDG PET/CT (94.9%) than for conventional staging tests (84.7%). Accuracy for TNM stage was higher (p < .05) for whole-body MRI (88.8%) and FDG PET/MRI (86.7%) than for FDG PET/CT (77.6%) and conventional staging tests (72.4%). Accuracy for VALSG stage was higher (p < .05) for whole-body MRI (95.9%), FDG PET/MRI (95.9%), and FDG PET/CT (98.0%) than for conventional staging tests (82.7%). Interobserver agreement, expressed as kappa coefficients, ranged from 0.81 to 0.94 across imaging tests and staging endpoints. CONCLUSION. FDG PET/CT, whole-body MRI, and coregistered FDG PET/MRI outperformed conventional tests for various staging endpoints in patients with SCLC. Whole-body MRI and FDG PET/MRI outperformed FDG PET/CT for T category and thus TNM stage, indicating the utility of MRI for assessing extent of local invasion in SCLC. CLINICAL IMPACT. Incorporation of either MRI approach may improve initial staging evaluation in SCLC.


Asunto(s)
Neoplasias Pulmonares , Carcinoma Pulmonar de Células Pequeñas , Anciano , Femenino , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética/métodos , Masculino , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Radiofármacos , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen , Carcinoma Pulmonar de Células Pequeñas/patología , Imagen de Cuerpo Entero/métodos
6.
Acta Radiol ; 63(10): 1363-1373, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34636644

RESUMEN

BACKGROUND: The need for quantitative assessment of interstitial lung involvement on thin-section computed tomography (CT) has arisen in interstitial lung diseases including connective tissue disease (CTD). PURPOSE: To evaluate the capability of machine learning (ML)-based CT texture analysis for disease severity and treatment response assessments in comparison with qualitatively assessed thin-section CT for patients with CTD. MATERIAL AND METHODS: A total of 149 patients with CTD-related ILD (CTD-ILD) underwent initial and follow-up CT scans (total 364 paired serial CT examinations), pulmonary function tests, and serum KL-6 level tests. Based on all follow-up examination results, all paired serial CT examinations were assessed as "Stable" (n = 188), "Worse" (n = 98) and "Improved" (n = 78). Next, quantitative index changes were determined by software, and qualitative disease severity scores were assessed by consensus of two radiologists. To evaluate differences in each quantitative index as well as in disease severity score between paired serial CT examinations, Tukey's honestly significant difference (HSD) test was performed among the three statuses. Stepwise regression analyses were performed to determine changes in each pulmonary functional parameter and all quantitative indexes between paired serial CT scans. RESULTS: Δ% normal lung, Δ% consolidation, Δ% ground glass opacity, Δ% reticulation, and Δdisease severity score showed significant differences among the three statuses (P < 0.05). All differences in pulmonary functional parameters were significantly affected by Δ% normal lung, Δ% reticulation, and Δ% honeycomb (0.16 ≤r2 ≤0.42; P < 0.05). CONCLUSION: ML-based CT texture analysis has better potential than qualitatively assessed thin-section CT for disease severity assessment and treatment response evaluation for CTD-ILD.


Asunto(s)
Enfermedades del Tejido Conjuntivo , Enfermedades Pulmonares Intersticiales , Enfermedades del Tejido Conjuntivo/diagnóstico , Enfermedades del Tejido Conjuntivo/tratamiento farmacológico , Humanos , Pulmón/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/terapia , Aprendizaje Automático , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos
7.
J Magn Reson Imaging ; 53(4): 1042-1051, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33205499

RESUMEN

BACKGROUND: Oxygen (O2 )-enhanced MRI is mainly performed by a 2D sequence using 1.5T MR systems but trying to be obtained by a 3D sequence using a 3T MR system. PURPOSE: To compare the capability of 3D O2 -enhanced MRI and that of thin-section computed tomography (CT) for pulmonary functional loss assessment and clinical stage classification of chronic obstructive pulmonary disease (COPD) in smokers. STUDY TYPE: Prospective study. POPULATION: Fifty six smokers were included. FIELD STRENGTH/ SEQUENCE: 3T, 3D O2 -enhanced MRIs were performed with a 3D T1 -weighted fast field echo pulse sequence using the multiple flip angles. ASSESSMENTS: Smokers were classified into four stages ("Without COPD," "Mild COPD," "Moderate COPD," "Severe or very severe COPD"). Maps of regional changes in T1 values were generated from O2 -enhanced MR data. Regions of interest (ROIs) were then placed over the lung on all slices and averaged to determine mean T1 value change (ΔT1 ). Quantitative CT used the percentage of low attenuation areas within the entire lung (LAA%). STATISTICAL TESTS: ΔT1 and LAA% were correlated with pulmonary functional parameters, and compared for four stages using Tukey's Honestly Significant Difference test. Discrimination analyses were performed and McNemar's test was used for a comparison of the accuracy of the indexes. RESULTS: There were significantly higher correlations between ΔT1 and pulmonary functional parameters (-0.83 ≤ r ≤ -0.71, P < 0.05) than between LAA% and the same pulmonary functional parameters (-0.76 ≤ r ≤ -0.69, P < 0.05). ΔT1 and LAA% of the "Mild COPD" and "Moderate COPD" groups were significantly different from those of the "Severe or Very Severe COPD" group (P < 0.05). Discriminatory accuracy of ΔT1 (62.5%) and ΔT1 with LAA% (67.9%) was significantly greater than that of LAA% (48.2%, P < 0.05). DATA CONCLUSION: Compared with thin-section CT, 3D O2 -enhanced MRI has a similar capability for pulmonary functional assessment but better potential for clinical stage classification in smokers. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Fumadores , Humanos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Oxígeno , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Pruebas de Función Respiratoria , Fumar , Tomografía Computarizada por Rayos X
8.
Radiology ; 296(2): 432-443, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32452736

RESUMEN

Background Deep learning may help to improve computer-aided detection of volume (CADv) measurement of pulmonary nodules at chest CT. Purpose To determine the efficacy of a deep learning method for improving CADv for measuring the solid and ground-glass opacity (GGO) volumes of a nodule, doubling time (DT), and the change in volume at chest CT. Materials and Methods From January 2014 to December 2016, patients with pulmonary nodules at CT were retrospectively reviewed. CADv without and with a convolutional neural network (CNN) automatically determined total nodule volume change per day and DT. Area under the curves (AUCs) on a per-nodule basis and diagnostic accuracy on a per-patient basis were compared among all indexes from CADv with and without CNN for differentiating benign from malignant nodules. Results The CNN training set was 294 nodules in 217 patients, the validation set was 41 nodules in 32 validation patients, and the test set was 290 nodules in 188 patients. A total of 170 patients had 290 nodules (mean size ± standard deviation, 11 mm ± 5; range, 4-29 mm) diagnosed as 132 malignant nodules and 158 benign nodules. There were 132 solid nodules (46%), 106 part-solid nodules (36%), and 52 ground-glass nodules (18%). The test set results showed that the diagnostic performance of the CNN with CADv for total nodule volume change per day was larger than DT of CADv with CNN (AUC, 0.94 [95% confidence interval {CI}: 0.90, 0.96] vs 0.67 [95% CI: 0.60, 0.74]; P < .001) and CADv without CNN (total nodule volume change per day: AUC, 0.69 [95% CI: 0.62, 0.75]; P < .001; DT: AUC, 0.58 [95% CI: 0.51, 0.65]; P < .001). The accuracy of total nodule volume change per day of CADv with CNN was significantly higher than that of CADv without CNN (P < .001) and DT of both methods (P < .001). Conclusion Convolutional neural network is useful for improving accuracy of computer-aided detection of volume measurement and nodule differentiation capability at CT for patients with pulmonary nodules. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Redes Neurales de la Computación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Pulmonares/clasificación , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/clasificación , Estudios Retrospectivos , Sensibilidad y Especificidad
9.
AJR Am J Roentgenol ; 215(5): 1191-1198, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32960670

RESUMEN

OBJECTIVE. The purpose of this study was to compare diagnostic accuracy of TNM stage for whole-body MRI and coregistered PET/MRI using 1.5-T and 3-T MRI systems and PET/CT in patients with non-small cell lung cancer (NSCLC). SUBJECTS AND METHODS. A total of 104 patients with pathologically diagnosed NSCLC underwent whole-body MRI at 1.5 T and 3T and integrated PET/CT, as well as a combination of surgical, pathologic, or follow-up examinations. Whole-body MR images obtained by the five sequences were combined with the PET part of the PET/CT using proprietary software for the PET/MRI studies. The TNM stage obtained with all methods was visually assessed. Kappa statistics were used to determine agreement between TNM stage assessment and final diagnoses, and the McNemar test was used to compare diagnostic accuracy of all methods. RESULTS. Findings of TNM stage on whole-body MRI using 3-T (κ, 0.87; p < 0.0001) and 1.5-T (κ, 0.83; p < 0.0001) systems and for coregistered PET/MRI using a 3-T system (PET/MRI3T; κ, 0.85; p < 0.0001) were rated as significant and almost perfect, and findings for coregistered PET/MRI using a 1.5-T system (PET/MRI1.5T; κ, 0.80; p < 0.0001) and PET/CT (κ, 0.73; p < 0.0001) were rated significant and substantial. Diagnostic accuracy of whole-body MRI using the 3-T system was 88.5% (92/104; p = 0.0002, and using the 1.5-T system it was 84.6% (88/104; p = 0.004); results for PET/MRI3T and PET/MRI1.5T were 86.5% (90/104; p = 0.001) and 81.7% (85/104; p = 0.03), respectively, which were both significantly better than accuracy of results for PET/CT at 76.0% (79/104). Moreover, diagnostic accuracy of whole-body MRI using a 3-T system was significantly higher than that of PET/MRI using a 1.5-T system (p = 0.02). CONCLUSION. Whole-body MRI and coregistered PET/MRI using 3-T and 1.5-T systems are as accurate or more accurate than PET/CT, whereas differences between 3-T and 1.5-T MRI systems are not considered significant.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética/métodos , Imagen Multimodal , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos , Anciano , Femenino , Humanos , Masculino , Estadificación de Neoplasias , Estudios Prospectivos , Reproducibilidad de los Resultados
10.
Kyobu Geka ; 72(13): 1072-1075, 2019 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-31879382

RESUMEN

A 69-year-old man with hypertension was referred for an abnormal shadow detected on chest computed tomography(CT) at a medical checkup. Enhanced CT showed a highly enhanced posterior mediastinal tumor of 34×27 mm. Magnetic resonance imaging (MRI) revealed a low signal intensity on T1-weighted images and high signal intensity on T2-weighted images. Thus, a neurogenic tumor was suspected and the surgery was performed. The tumor was carefully dissected as it was hyper-vascular and hemorrhagic. Immediately after tumor resection, the patient's blood pressure rapidly decreased, and phenylephrine hydrochloride was needed to maintain the blood pressure. The pathological diagnosis was paraganglioma.


Asunto(s)
Neoplasias del Mediastino , Paraganglioma , Anciano , Humanos , Imagen por Resonancia Magnética , Masculino , Mediastino , Tomografía Computarizada por Rayos X
11.
AJR Am J Roentgenol ; 210(2): W45-W53, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29220212

RESUMEN

OBJECTIVE: The objective of this study was to compare the capability of xenon-enhanced area-detector CT (ADCT) performed with a subtraction technique and coregistered 81mKr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity in smokers. SUBJECTS AND METHODS: Forty-six consecutive smokers (32 men and 14 women; mean age, 67.0 years) underwent prospective unenhanced and xenon-enhanced ADCT, 81mKr-ventilation SPECT/CT, and pulmonary function tests. Disease severity was evaluated according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification. CT-based functional lung volume (FLV), the percentage of wall area to total airway area (WA%), and ventilated FLV on xenon-enhanced ADCT and SPECT/CT were calculated for each smoker. All indexes were correlated with percentage of forced expiratory volume in 1 second (%FEV1) using step-wise regression analyses, and univariate and multivariate logistic regression analyses were performed. In addition, the diagnostic accuracy of the proposed model was compared with that of each radiologic index by means of McNemar analysis. RESULTS: Multivariate logistic regression showed that %FEV1 was significantly affected (r = 0.77, r2 = 0.59) by two factors: the first factor, ventilated FLV on xenon-enhanced ADCT (p < 0.0001); and the second factor, WA% (p = 0.004). Univariate logistic regression analyses indicated that all indexes significantly affected GOLD classification (p < 0.05). Multivariate logistic regression analyses revealed that ventilated FLV on xenon-enhanced ADCT and CT-based FLV significantly influenced GOLD classification (p < 0.0001). The diagnostic accuracy of the proposed model was significantly higher than that of ventilated FLV on SPECT/CT (p = 0.03) and WA% (p = 0.008). CONCLUSION: Xenon-enhanced ADCT is more effective than 81mKr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Fumadores , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Criptón , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Pruebas de Función Respiratoria , Índice de Severidad de la Enfermedad , Xenón
12.
Jpn J Clin Oncol ; 48(1): 89-93, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29036303

RESUMEN

BACKGROUND: The optimal chemotherapy regimen for non-small cell lung cancer patients with interstitial lung disease is unclear. We therefore investigated the safety and efficacy of carboplatin plus nab-paclitaxel as a first-line regimen for non-small cell lung cancer in patients with interstitial lung disease. METHODS: We retrospectively reviewed advanced non-small cell lung cancer patients with interstitial lung disease who received carboplatin plus nab-paclitaxel as a first-line chemotherapy regimen at Hyogo Cancer Center between February 2013 and August 2016. interstitial lung disease was diagnosed according to the findings of pretreatment chest high-resolution computed tomography. RESULTS: Twelve patients were included (male, n = 11; female, n = 1). The overall response rate was 67% and the disease control rate was 100%. The median progression free survival was 5.1 months (95% CI: 2.9-8.3 months) and the median overall survival was 14.9 months (95% CI: 4.8-not reached). A chemotherapy-related acute exacerbation of interstitial lung disease was observed in one patient; the extent of this event was Grade 2. There were no treatment-related deaths. CONCLUSIONS: Carboplatin plus nab-paclitaxel, as a first-line chemotherapy regimen for non-small cell lung cancer, showed favorable efficacy and safety in patients with preexisting interstitial lung disease.


Asunto(s)
Albúminas/uso terapéutico , Carboplatino/efectos adversos , Carboplatino/uso terapéutico , Carcinoma de Pulmón de Células no Pequeñas/complicaciones , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Enfermedades Pulmonares Intersticiales/complicaciones , Neoplasias Pulmonares/tratamiento farmacológico , Nanopartículas/uso terapéutico , Paclitaxel/uso terapéutico , Adulto , Anciano , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Carboplatino/administración & dosificación , Supervivencia sin Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Enfermedades Pulmonares Intersticiales/inducido químicamente , Masculino , Persona de Mediana Edad , Nanopartículas/administración & dosificación , Estudios Retrospectivos , Resultado del Tratamiento
13.
Radiology ; 284(2): 562-573, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28263700

RESUMEN

Purpose To compare the capability of pulmonary thin-section magnetic resonance (MR) imaging with ultrashort echo time (UTE) with that of standard- and reduced-dose thin-section computed tomography (CT) in nodule detection and evaluation of nodule type. Materials and Methods The institutional review board approved this study, and written informed consent was obtained from each patient. Standard- and reduced-dose chest CT (60 and 250 mA) and MR imaging with UTE were used to examine 52 patients; 29 were men (mean age, 66.4 years ± 7.3 [standard deviation]; age range, 48-79 years) and 23 were women (mean age, 64.8 years ± 10.1; age range, 42-83 years). Probability of nodule presence was assessed for all methods with a five-point visual scoring system. All nodules were then classified as missed, ground-glass, part-solid, or solid nodules. To compare nodule detection capability of the three methods, consensus for performances was rated by using jackknife free-response receiver operating characteristic analysis, and κ analysis was used to compare intermethod agreement for nodule type classification. Results There was no significant difference (F = 0.70, P = .59) in figure of merit between methods (standard-dose CT, 0.86; reduced-dose CT, 0.84; MR imaging with UTE, 0.86). There was no significant difference in sensitivity between methods (standard-dose CT vs reduced-dose CT, P = .50; standard-dose CT vs MR imaging with UTE, P = .50; reduced-dose CT vs MR imaging with UTE, P >.99). Intermethod agreement was excellent (standard-dose CT vs reduced-dose CT, κ = 0.98, P < .001; standard-dose CT vs MR imaging with UTE, κ = 0.98, P < .001; reduced-dose CT vs MR imaging with UTE, κ = 0.99, P < .001). Conclusion Pulmonary thin-section MR imaging with UTE was useful in nodule detection and evaluation of nodule type, and it is considered at least as efficacious as standard- or reduced-dose thin-section CT. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/patología , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Técnicas de Imagen Sincronizada Respiratorias
15.
J Magn Reson Imaging ; 43(2): 512-32, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26223818

RESUMEN

BACKGROUND: To determine the accuracy of pulmonary MR imaging with ultrashort echo time (UTE) for lung and mediastinum assessments using computed tomography (CT) as the reference standard, for various pulmonary parenchyma diseases. METHODS: Eight-five consecutive patients (46 males: mean age, 69 years and 39 females: mean age, 69 years) with various pulmonary parenchyma diseases were examined with chest standard- and low-dose CTs and pulmonary MR imaging with UTE. This was followed by visual assessment using a 5-point system of the presence of nodules or masses, ground-glass opacity, micronodules, nodules, patchy shadow or consolidation, emphysema or bullae, bronchiectasis, reticular opacity, and honeycomb and traction bronchiectasis. Presence of aneurysms, pleural or pericardial effusions, pleural thickening or tumor, and lymph adenopathy was also evaluated using a 5-point system. To compare the capability of the methods for lung parenchyma and mediastinum evaluation, intermethod agreement was evaluated by means of kappa statistics and χ2 test. Receiver operating characteristic analyses were used to compare diagnostic performance of all methods. RESULTS: Intermethod agreements between pulmonary MR imaging and standard-dose and low-dose CT were significant and either substantial or almost perfect (0.67 ≤ κ ≤ 0.98; P < 0.0001). Areas under the curve for emphysema or bullae, bronchiectasis or traction bronchiectasis and reticular opacity on standard-dose CT were significantly larger than those on low-dose CT (emphysema or bullae: P = 0.0002; reticular opacity: P < 0.0001) and pulmonary MR imaging (emphysema or bullae: P < 0.0001; bronchiectasis: P = 0.008; reticular opacity: P < 0.0001). CONCLUSION: Pulmonary MR imaging with UTE is useful for lung and mediastinum assessment and evaluation of radiological findings for patients with various pulmonary parenchyma diseases.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/patología , Imagen por Resonancia Magnética/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
16.
Radiology ; 275(3): 849-61, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25584709

RESUMEN

PURPOSE: To prospectively compare the capabilities for TNM classification and assessment of clinical stage and operability among whole-body magnetic resonance (MR) imaging, coregistered positron emission tomographic (PET)/MR imaging with and without MR signal intensity (SI) assessment, and integrated fluorine 18 fluorodeoxyglucose (FDG) PET/computed tomography (CT) in non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS: The institutional review board approved this study, and written informed consent was obtained from each patient. One hundred forty consecutive NSCLC patients (75 men, 65 women; mean age, 72 years) prospectively underwent whole-body MR imaging, FDG PET/CT, conventional radiologic examinations, and surgical, pathologic, and/or follow-up examinations. All factors and clinical stage and operability were then visually assessed. All PET/MR examinations were assessed with and without SI assessment. One examination used anatomic, metabolic, and relaxation-time information, and the other used only anatomic and metabolic information. κ statistics were used for assessment of all factors and clinical stages with final diagnoses. McNemar test was used to compare the capability of all methods to assess operability. RESULTS: Agreements of assessment of every factor (κ = 0.63-0.97) and clinical stage (κ = 0.65-0.90) were substantial or almost perfect. Regarding capability to assess operability, accuracy of whole-body MR imaging and PET/MR imaging with SI assessment (97.1% [136 of 140]) was significantly higher than that of MR/PET without SI assessment and integrated FDG PET/CT (85.0% [119 of 140]; P < .001). CONCLUSION: Accuracies of whole-body MR imaging and PET/MR imaging with SI assessment are superior to PET/MR without SI assessment and PET/CT for identification of TNM factor, clinical stage, and operability evaluation of NSCLC patients.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico , Imagen por Resonancia Magnética , Imagen Multimodal , Tomografía de Emisión de Positrones , Radiofármacos , Imagen de Cuerpo Entero/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos
17.
J Magn Reson Imaging ; 42(2): 340-53, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26192552

RESUMEN

PURPOSE: To compare predictive capabilities of non-contrast-enhanced (CE)- and dynamic CE-perfusion MRIs, thin-section multidetector computed tomography (CT) (MDCT), and perfusion scan for postoperative lung function in non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS: Sixty consecutive pathologically diagnosed NSCLC patients were included and prospectively underwent thin-section MDCT, non-CE-, and dynamic CE-perfusion MRIs and perfusion scan, and had their pre- and postoperative forced expiratory volume in one second (FEV1 ) measured. Postoperative percent FEV1 (po%FEV1 ) was then predicted from the fractional lung volume determined on semiquantitatively assessed non-CE- and dynamic CE-perfusion MRIs, from the functional lung volumes determined on quantitative CT, from the number of segments observed on qualitative CT, and from uptakes detected on perfusion scans within total and resected lungs. Predicted po%FEV1 s were then correlated with actual po%FEV1 s, which were %FEV1 s measured postoperatively. The limits of agreement were also determined. RESULTS: All predicted po%FEV1 s showed significant correlation (0.73 ≤ r ≤ 0.93, P < 0.0001) and limits of agreement with actual po%FEV1 (non-CE-perfusion MRI: 0.3 ± 10.0%, dynamic CE-perfusion MRI: 1.0 ± 10.8%, perfusion scan: 2.2 ± 14.1%, quantitative CT: 1.2 ± 9.0%, qualitative CT: 1.5 ± 10.2%). CONCLUSION: Non-CE-perfusion MRI may be able to predict postoperative lung function more accurately than qualitatively assessed MDCT and perfusion scan.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirugía , Angiografía por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Técnicas de Imagen Sincronizada Cardíacas/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Pronóstico , Reproducibilidad de los Resultados , Pruebas de Función Respiratoria/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Sensibilidad y Especificidad , Resultado del Tratamiento
18.
Radiology ; 270(3): 834-41, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24475844

RESUMEN

PURPOSE: To explore any correlation between the number of previous gadolinium-based contrast material administrations and high signal intensity (SI) in the dentate nucleus and globus pallidus on unenhanced T1-weighted magnetic resonance (MR) images. MATERIALS AND METHODS: The institutional review board approved this study, waiving the requirement to obtain written informed consent. A group of 381 consecutive patients who had undergone brain MR imaging was identified for cross-sectional analysis. For longitudinal analysis, 19 patients who had undergone at least six contrast-enhanced examinations were compared with 16 patients who had undergone at least six unenhanced examinations. The mean SIs of the dentate nucleus, pons, globus pallidus, and thalamus were measured on unenhanced T1-weighted images. The dentate nucleus-to-pons SI ratio was calculated by dividing the SI in the dentate nucleus by that in the pons, and the globus pallidus-to-thalamus SI ratio was calculated by dividing the SI in the globus pallidus by that in the thalamus. Stepwise regression analysis was undertaken in the consecutive patient group to detect any relationship between the dentate nucleus-to-pons or globus pallidus-to-thalamus SI ratio and previous gadolinium-based contrast material administration or other factors. A random coefficient model was used to evaluate for longitudinal analysis. RESULTS: The dentate nucleus-to-pons SI ratio showed a significant correlation with the number of previous gadolinium-based contrast material administrations (P < .001; regression coefficient, 0.010; 95% confidence interval [CI]: 0.009, 0.011; standardized regression coefficient, 0.695). The globus pallidus-to-thalamus SI ratio showed a significant correlation with the number of previous gadolinium-based contrast material administrations (P < .001; regression coefficient, 0.004; 95% CI: 0.002, 0.006; standardized regression coefficient, 0.288), radiation therapy (P = .009; regression coefficient, -0.014; 95% CI: -0.025, -0.004; standardized regression coefficient, -0.151), and liver function (P = .031; regression coefficient, 0.023; 95% CI: 0.002, 0.044; standardized regression coefficient, 0.107). The dentate nucleus-to-pons and globus pallidus-to-thalamus SI ratios in patients who had undergone contrast-enhanced examinations were significantly greater than those of patients who had undergone unenhanced examinations (P < .001 for both). CONCLUSION: High SI in the dentate nucleus and globus pallidus on unenhanced T1-weighted images may be a consequence of the number of previous gadolinium-based contrast material administrations.


Asunto(s)
Encefalopatías/diagnóstico , Núcleos Cerebelosos/patología , Globo Pálido/patología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Encefalopatías/patología , Medios de Contraste/administración & dosificación , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
19.
Radiol Phys Technol ; 17(3): 610-619, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38805078

RESUMEN

The purpose of this study was to investigate the spatial resolution of non-contrast-enhanced (CE) T2prep multi-shot gradient echo planar imaging (MSG-EPI) magnetic resonance angiography (MRA) required to identify peroneal artery perforators and demonstrate its effectiveness in preoperative simulation. Twenty-six legs of 13 volunteers were scanned using non-CE T2prep MSG-EPI-MRA at three spatial resolutions: 1.0-, 0.8-, and 0.6-mm isotropic voxels. The location and number of peroneal artery perforators that could be candidates for free fibula flaps were identified by consensus among three plastic surgeons. Surgeons distinguished between septocutaneous and musculocutaneous perforators using MRA, and confirmed the accuracy of their presence and identification using ultrasonography (US). The ability to detect hypoplasia or stenosis of the anterior tibial, posterior tibial, and peroneal arteries was evaluated by confirming the consistency between the MRA and US results. The number of cutaneous perforators identified using MRA and confirmed using US was 39, 51, and 52 at each respective resolution. The discrimination accuracies between septocutaneous and musculocutaneous perforators were 92.3%, 96.1%, and 96.2%. The number of identified septocutaneous perforators was 1.3 ± 0.6, 1.6 ± 0.8, and 1.7 ± 0.8 at 1.0-, 0.8-, and 0.6-mm data, respectively. All the MRA results, including hypoplasia and stenosis, were consistent with the US results. Non-CE T2prep MSG-EPI-MRA with a spatial resolution of 0.8 mm or less shows promise for identifying septocutaneous perforators of the peroneal artery, suggesting its potential as an alternative to conventional imaging methods for the preoperative planning of free fibula osteocutaneous flap transfers.


Asunto(s)
Imagen Eco-Planar , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Adulto , Femenino , Masculino , Imagen Eco-Planar/métodos , Arterias/diagnóstico por imagen , Adulto Joven , Persona de Mediana Edad
20.
Clin Chest Med ; 45(2): 505-529, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38816103

RESUMEN

Many promising study results as well as technical advances for chest magnetic resonance imaging (MRI) have demonstrated its academic and clinical potentials during the last few decades, although chest MRI has been used for relatively few clinical situations in routine clinical practice. However, the Fleischner Society as well as the Japanese Society of Magnetic Resonance in Medicine have published a few white papers to promote chest MRI in routine clinical practice. In this review, we present clinical evidence of the efficacy of chest MRI for 1) thoracic oncology and 2) pulmonary vascular diseases.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico , Neoplasias Torácicas/diagnóstico por imagen , Neoplasias Torácicas/diagnóstico , Neoplasias Torácicas/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA