Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiothorac Vasc Anesth ; 35(12): 3677-3680, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33478883

RESUMEN

OBJECTIVES: Patients with Williams-Beuren syndrome are associated with a high risk of hemodynamic collapse during sedation and/or anesthesia, presumably due to occult coronary obstruction. The objective of this study was to determine the association between transthoracic echocardiogram findings and the presence of coronary obstruction to examine if coronary obstruction can be predicted by transthoracic echocardiogram before anesthesia. DESIGN: Retrospective data analysis of patients with Williams-Beuren syndrome who underwent transthoracic echocardiogram, cardiac catheterization, and/or surgical interventions to determine the correlation between echocardiogram findings and the presence of coronary obstruction determined by cardiac catheterization and/or surgery. SETTING: Single-center university teaching hospital. PARTICIPANTS: The study included 49 patients with Williams-Beuren syndrome who underwent transthoracic echocardiogram, cardiac catheterization, and/or surgical interventions. MEASUREMENTS AND MAIN RESULTS: The only variable associated with coronary artery obstruction was the maximum instantaneous gradient (MIG) across the left ventricular outflow tract (LVOT) on a transthoracic echocardiogram. LVOT MIG ≥ 75 mmHg as the optimal cutoff value was associated with coronary artery obstruction (area under the curve 0.659, odds ratio 6.71, 95% CI 1.31-34.35, p = 0.022). CONCLUSION: LVOT gradient can serve as a good predictor of the presence of coronary obstruction in patients with Williams-Beuren syndrome.


Asunto(s)
Obstrucción del Flujo Ventricular Externo , Síndrome de Williams , Cateterismo Cardíaco , Niño , Vasos Coronarios , Humanos , Estudios Retrospectivos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Síndrome de Williams/complicaciones , Síndrome de Williams/diagnóstico por imagen
3.
Oxf Med Case Reports ; 2015(6): 303-5, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26069842

RESUMEN

Ultrasound-guided cannulation of a central venous catheter into the internal jugular vein (IJV) was performed in the intensive care unit for a critically ill patient. The catheter was inserted into the subclavian artery distally, despite prior ultrasound confirmation of the guidewire position using both the in-plane and out-of-plane views. The catheter was removed successfully by the interventional radiologist with a closure device. To our knowledge, there have been previous case reports of subclavian artery injury during IJV cannulation with ultrasound guidance, but rarely in the setting whereby the guidewire was visualized before dilatation and railroading of the catheter. This case demonstrates that the confirmation of the guidewire in the proximal segment of the vein is insufficient to exclude arterial cannulation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA