Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Imaging Radiat Oncol ; 5: 102-107, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33458378

RESUMEN

BACKGROUND AND PURPOSE: During radiotherapy, prostate motion changes over time. Quantifying and accounting for this motion is essential. This study aimed to assess intra-fraction prostate motion and derive duration-dependent planning margins for two treatment techniques. MATERIAL AND METHODS: A four-dimension (4D) transperineal ultrasound Clarity® system was used to track prostate motion. We analysed 1913 fractions from 60 patients undergoing volumetric-modulated arc therapy (VMAT) to the prostate. The mean VMAT treatment duration was 3.4 min. Extended monitoring was conducted weekly to simulate motion during intensity-modulated radiation therapy (IMRT) treatment (an additional seven minutes). A motion-time trend analysis was conducted and the mean intra-fraction motion between VMAT and IMRT treatments compared. Duration-dependent margins were calculated and anisotropic margins for VMAT and IMRT treatments were derived. RESULTS: There were statistically significant differences in the mean intra-fraction motion between VMAT and the simulated IMRT duration in the inferior (0.1 mm versus 0.3 mm) and posterior (-0.2 versus -0.4 mm) directions respectively (p ≪ 0.01). An intra-fraction motion trend inferiorly and posteriorly was observed. The recommended minimum anisotropic margins are 1.7 mm/2.7 mm (superior/inferior); 0.8 mm (left/right), 1.7 mm/2.9 mm (anterior/posterior) for VMAT treatments and 2.9 mm/4.3 mm (superior/inferior), 1.5 mm (left/right), 2.8 mm/4.8 mm (anterior/posterior) for IMRT treatments. Smaller anisotropic margins were required for VMAT compared to IMRT (differences ranging from 1.2 to 1.6 mm superiorly/inferiorly, 0.7 mm laterally and 1.1-1.9 mm anteriorly/posteriorly). CONCLUSIONS: VMAT treatment is preferred over IMRT as prostate motion increases with time. Larger margins should be employed in the inferior and posterior directions for both treatment durations. Duration-dependent margins should be applied in the presence of prolonged imaging and verification time.

2.
Artículo en Inglés | MEDLINE | ID: mdl-32095569

RESUMEN

BACKGROUND AND PURPOSE: Inconsistent bladder and rectal volumes have been associated with motion uncertainties during prostate radiotherapy. This study investigates the impact of these volumes to determine the optimal bladder volume. MATERIALS AND METHODS: 60 patients from two Asian hospitals were recruited prospectively. 1887 daily cone-beam computed tomography (CBCT) images were analysed. Intra-fraction motion of the prostate was monitored real-time using a four-dimension transperineal ultrasound (4D TPUS) Clarity® system. The impact of planned bladder volume, adequacy of daily bladder filling, and rectum volume on mean intra-fraction motion of the prostate was analysed. Patients' ability to comply with the full bladder hydration protocol and level of frustration was assessed using a questionaire. Acute side effects were assessed using the Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 and quality of life (QoL) assessed using the International Prostate Symptom Score (IPSS). RESULTS: The mean (SD) bladder and rectum volumes achieved during daily treatment were 139.7 cm3 (82.4 cm3) and 53.3 cm3 (18 cm3) respectively. Mean (SD) percentage change from planned CT volumes in bladder volume was reduced by 8.2% (48.7%) and rectum volume was increased by 12.4% (42.2%). Linear Mixed effect model analysis revealed a reduction in intra-fraction motion in both the Sup/Inf (p = 0.008) and Ant/Post (p = 0.0001) directions when the daily bladder was filled between 82 and 113% (3rd Quartiles) of the planned CT volumes. A reduction in intra-fraction motion of the prostate in the Ant/Post direction (z-plane) (p = 0.03) was observed when the planned bladder volume was greater than 200 ml. Patients complied well with the hydration protocol with minimal frustration (mean (SD) scores of 2.1 (1.4) and 1.8 (1.2) respectively). There was a moderate positive correlation (0.496) between mean bladder volume and IPSS reported post-treatment urinary straining (p = 0.001). CONCLUSIONS: A planned bladder volume >200 cm3 and daily filling between 82 and 113%, reduced intra-fraction motion of the prostate. The hydration protocol was well tolerated.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA