Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 162
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Orthop Relat Res ; 482(2): 352-358, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37603308

RESUMEN

BACKGROUND: Massive modular endoprostheses have become a primary means of reconstruction after oncologic resection of a lower extremity tumor. These implants are commonly made with cobalt-chromium alloys that can undergo wear and corrosion, releasing cobalt and chromium ions into the surrounding tissue and blood. However, there are few studies about the blood metal levels in these patients. QUESTION/PURPOSE: What is the whole blood cobalt and chromium ion level in patients with massive modular endoprostheses? METHODS: We performed a cross-sectional study of our total joints registry to identify patients with a history of an endoprosthetic reconstruction performed at our institution. Patients who were alive at the time of our review in addition to those undergoing an endoprosthetic reconstruction after an oncologic resection were included. Whole blood samples were obtained from 27 (14 male and 13 female) patients with a history of a lower extremity oncologic endoprosthesis. The median time from surgery to blood collection was 8 years (range 6 months to 32 years). Blood samples were collected and stored in metal-free ethylenediaminetetraacetic acid tubes. Samples were analyzed on an inductively coupled plasma mass spectrometer in an International Organization for Standardization seven-class clean room using polytetrafluoroethylene-coated instruments to reduce the risk of metal contamination. The analytical measuring range was 1 to 200 ng/mL for chromium and cobalt. Cobalt and chromium levels were considered elevated when the blood level was ≥ 1 ppb. RESULTS: Cobalt levels were elevated in 59% (16 of 27) of patients, and chromium levels were elevated in 26% (seven of 27). In patients with elevated metal ion values, 15 of 17 patients had a reconstruction using a Stryker/Howmedica Global Modular Replacement System implant. CONCLUSION: Blood metal levels were elevated in patients who received reconstructions using modular oncology endoprostheses Future work is needed to establish appropriate follow-up routines and determine whether and when systemic complications occur because of elevated metal levels and how to potentially address these elevated levels when complications occur. Prospective and retrospective collaboration between multiple centers and specialty societies will be necessary to address these unknown questions in this potentially vulnerable patient group. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Masculino , Femenino , Estudios Retrospectivos , Estudios Prospectivos , Estudios Transversales , Diseño de Prótesis , Cromo , Cobalto , Artroplastia de Reemplazo de Cadera/efectos adversos , Falla de Prótesis
2.
J Arthroplasty ; 39(3): 727-733.e4, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37619804

RESUMEN

BACKGROUND: This study introduces THA-Net, a deep learning inpainting algorithm for simulating postoperative total hip arthroplasty (THA) radiographs from a single preoperative pelvis radiograph input, while being able to generate predictions either unconditionally (algorithm chooses implants) or conditionally (surgeon chooses implants). METHODS: The THA-Net is a deep learning algorithm which receives an input preoperative radiograph and subsequently replaces the target hip joint with THA implants to generate a synthetic yet realistic postoperative radiograph. We trained THA-Net on 356,305 pairs of radiographs from 14,357 patients from a single institution's total joint registry and evaluated the validity (quality of surgical execution) and realism (ability to differentiate real and synthetic radiographs) of its outputs against both human-based and software-based criteria. RESULTS: The surgical validity of synthetic postoperative radiographs was significantly higher than their real counterparts (mean difference: 0.8 to 1.1 points on 10-point Likert scale, P < .001), but they were not able to be differentiated in terms of realism in blinded expert review. Synthetic images showed excellent validity and realism when analyzed with already validated deep learning models. CONCLUSION: We developed a THA next-generation templating tool that can generate synthetic radiographs graded higher on ultimate surgical execution than real radiographs from training data. Further refinement of this tool may potentiate patient-specific surgical planning and enable technologies such as robotics, navigation, and augmented reality (an online demo of THA-Net is available at: https://demo.osail.ai/tha_net).


Asunto(s)
Artroplastia de Reemplazo de Cadera , Aprendizaje Profundo , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Radiografía , Estudios Retrospectivos
3.
J Arthroplasty ; 39(4): 966-973.e17, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37770007

RESUMEN

BACKGROUND: Revision total hip arthroplasty (THA) requires preoperatively identifying in situ implants, a time-consuming and sometimes unachievable task. Although deep learning (DL) tools have been attempted to automate this process, existing approaches are limited by classifying few femoral and zero acetabular components, only classify on anterior-posterior (AP) radiographs, and do not report prediction uncertainty or flag outlier data. METHODS: This study introduces Total Hip Arhtroplasty Automated Implant Detector (THA-AID), a DL tool trained on 241,419 radiographs that identifies common designs of 20 femoral and 8 acetabular components from AP, lateral, or oblique views and reports prediction uncertainty using conformal prediction and outlier detection using a custom framework. We evaluated THA-AID using internal, external, and out-of-domain test sets and compared its performance with human experts. RESULTS: THA-AID achieved internal test set accuracies of 98.9% for both femoral and acetabular components with no significant differences based on radiographic view. The femoral classifier also achieved 97.0% accuracy on the external test set. Adding conformal prediction increased true label prediction by 0.1% for acetabular and 0.7 to 0.9% for femoral components. More than 99% of out-of-domain and >89% of in-domain outlier data were correctly identified by THA-AID. CONCLUSIONS: The THA-AID is an automated tool for implant identification from radiographs with exceptional performance on internal and external test sets and no decrement in performance based on radiographic view. Importantly, this is the first study in orthopedics to our knowledge including uncertainty quantification and outlier detection of a DL model.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Aprendizaje Profundo , Prótesis de Cadera , Humanos , Incertidumbre , Acetábulo/cirugía , Estudios Retrospectivos
4.
J Arthroplasty ; 39(9S2): S459-S463, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38548235

RESUMEN

BACKGROUND: Previous studies have suggested that wound complications may differ by surgical approach after total hip arthroplasty (THA), with particular attention toward the direct anterior approach (DAA). However, there is a paucity of data documenting wound complication rates by surgical approach and the impact of concomitant patient factors, namely body mass index (BMI). This investigation sought to determine the rates of wound complications by surgical approach and identify BMI thresholds that portend differential risk. METHODS: This multicenter study retrospectively evaluated all primary THA patients from 2010 to 2023. Patients were classified by skin incision as having a laterally based approach (posterior or lateral approach) or DAA (longitudinal incision). We identified 17,111 patients who had 11,585 laterally based (68%) and 5,526 (32%) DAA THAs. The mean age was 65 years (range, 18 to 100), 8,945 patients (52%) were women, and the mean BMI was 30 (range, 14 to 79). Logistic regression and cut-point analyses were performed to identify an optimal BMI cutoff, overall and by approach, with respect to the risk of wound complications at 90 days. RESULTS: The 90-day risk of wound complications was higher in the DAA group versus the laterally based group, with an absolute risk of 3.6% versus 2.6% and a multivariable adjusted odds ratio of 1.5 (P < .001). Cut-point analyses demonstrated that the risk of wound complications increased steadily for both approaches, but most markedly above a BMI of 33. CONCLUSIONS: Wound complications were higher after longitudinal incision DAA THA compared to laterally based approaches, with a 1% higher absolute risk and an adjusted odds ratio of 1.5. Furthermore, BMI was an independent risk factor for wound complications regardless of surgical approach, with an optimal cut-point BMI of 33 for both approaches. These data can be used by surgeons to help consider the risks and benefits of approach selection. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Índice de Masa Corporal , Infección de la Herida Quirúrgica , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Anciano de 80 o más Años , Adulto , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/epidemiología , Factores de Riesgo , Adolescente , Adulto Joven , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
5.
J Arthroplasty ; 39(9S1): S97-S100, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38735544

RESUMEN

BACKGROUND: Our previously reported randomized clinical trial of direct anterior approach (DAA) versus mini-posterior approach (MPA) total hip arthroplasty showed slightly faster initial recovery for patients who had a DAA and no differences in complications or clinical or radiographic outcomes beyond 8 weeks. The aims of the current study were to determine if early advantages of DAA led to meaningful clinical differences beyond 5 years and to identify differences in midterm complications. METHODS: Of the 101 original patients, 93 were eligible for follow-up at a mean of 7.5 years (range, 2.1 to 10). Clinical outcomes were compared with Harris Hip, 12-Item Short Form Health Survey, and Hip Disability and Osteoarthritis Outcomes Scores (HOOS) scores and subscores, complications, reoperations, and revisions. RESULTS: Harris Hip scores were similar (95.3 ± 6.0 versus 93.5 ± 10.3 for DAA and MPA, respectively, P = .79). The 12-Item Short Form Health Survey physical and mental scores were similar (46.2 ± 9.3 versus 46.2 ± 10.6, P = .79, and 52.3 ± 7.1 versus 55.2 ± 4.5, P = .07 in the DAA and MPA groups, respectively). The HOOS scores were similar (97.4 ± 7.9 versus 96.3 ± 6.7 for DAA and MPA, respectively, P = .07). The HOOS quality of life subscores were 96.9 ± 10.8 versus 92.3 ± 16.0 for DAA and MPA, respectively (P = .046). No clinical outcome met the minimally clinically important difference. There were 4 surgical complications in the DAA group (1 femoral loosening requiring revision, 1 dislocation treated closed, and 2 wound dehiscences requiring debridement), and 6 surgical complications in the MPA group (3 dislocations, 2 treated closed, and 1 revised to dual mobility; 2 intraoperative fractures treated with a cable; and 1 wound dehiscence treated nonoperatively). CONCLUSIONS: At a mean of 7.5 years, this randomized clinical trial demonstrated no clinically meaningful differences in outcomes, complications, reoperations, or revisions between DAA and MPA total hip arthroplasty. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Osteoartritis de la Cadera/cirugía , Reoperación/estadística & datos numéricos , Estudios de Seguimiento , Complicaciones Posoperatorias/etiología , Articulación de la Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen , Recuperación de la Función
6.
J Arthroplasty ; 39(9S1): S3-S8, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38479635

RESUMEN

BACKGROUND: Intraprosthetic dissociation (IPD) is a complication unique to dual mobility (DM) implants where the outer polyethylene head dissociates from the inner femoral head. Increasing reports of IPD at the time of closed reduction of large head DM dislocations prompted this biomechanical study evaluating the assembly and dissociation forces of DM heads. METHODS: We tested 17 polyethylene DM heads from 5 vendors. Of the heads, 12 were highly cross-linked polyethylene (4 vendors) and 5 were infused with vitamin E (2 vendors). Heads were between 46 and 47 mm in diameter, accepting a 28 mm-inner ceramic head. Implants were assembled and disassembled using a servohydraulic machine that recorded the forces and torques applied during testing. Dissociation was tested via both axial pull-out and lever-out techniques, where lever-out simulated stem-on-acetabular component impingement. RESULTS: The initial maximum assembly force was significantly different between all vendors (P < .01) and decreased for all implants with subsequent assembly. Vendor 4-E (Link with vitamin E) heads required the highest assembly force (1,831.9 ± 81.95 N), followed by Vendor 3 (Smith & Nephew), Vendor 5 (DePuy Synthes), Vendor 1-E (Zimmer Biomet with vitamin E), Vendor 2 (Stryker), and Vendor 1 (Zimmer Biomet Arcom). Vendor 4-E implants showed the greatest dissociation resistance in both pull-out (2,059.89 N, n = 1) and lever-out (38.95 ± 2.79 Nm) tests. Vendor 1-E implants with vitamin E required higher assembly force, dissociation force, and energy than Vendor 1 heads without vitamin E. CONCLUSIONS: There were notable differences in DM assembly and dissociation forces between implants. Diminishing force was required for assembly with each additional trial across vendors. Vendor 4-E DM heads required the highest assembly and dissociation forces. Vitamin E appeared to increase the assembly and dissociation forces. Based on these results, DM polyethylene heads should not be reimplanted after dissociation, and there may be a role for establishing a minimum dissociation energy standard to minimize IPD risk.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Ensayo de Materiales , Diseño de Prótesis , Falla de Prótesis , Fenómenos Biomecánicos , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Polietileno/química , Distinciones y Premios , Cabeza Femoral , Vitamina E
7.
J Arthroplasty ; 2024 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-39284396

RESUMEN

INTRODUCTION: Soft tissue management in total hip arthroplasty (THA) includes appropriate restoration and/or alteration of leg length and offset to re-establish natural hip biomechanics. The purpose of this study was to evaluate the effect of leg length and offset-derived variables in a multivariable survival model for dislocation. METHODS: Clinical, surgical, and radiographic data was retrospectively acquired for 12,582 patients undergoing primary THA at a single institution from 1998 to 2018. There were twelve variables derived from preoperative and postoperative radiographs related to leg length and offset that were measured using a validated automated algorithm. These measurements, as well as other modifiable and non-modifiable surgical, clinical, and demographic factors, were used to determine hazard ratios (HR) for dislocation risk. RESULTS: None of the leg length or offset variables conferred significant risk or protective benefit for dislocation risk. By contrast, all other variables included in the multivariable model demonstrated a statistically significant effect on dislocation risk with a minimum effect size of 28% (range 0.72 to 1.54) (sex, surgical approach, acetabular liner type, femoral head size, neurologic disease, spine disease, and prior spine surgery). CONCLUSION: Contrary to traditional teaching and our hypothesis, operative changes in leg length and offset did not demonstrate any clinically or statistically significant effect in this large and well-characterized cohort. This does not imply that these variables are not important in individual cases, but rather suggests the overall impact of leg length and offset changes is relatively minor for dislocation risk compared to other variables that were found to be highly clinically and statistically significant in this population. These results may also suggest that surgeons do a good job of restoring native leg length and offset for patients, which may mitigate their analyzed impact.

8.
Int Orthop ; 48(4): 997-1010, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38224400

RESUMEN

PURPOSE: The purpose of this review is to evaluate the current status of research on the application of artificial intelligence (AI)-based three-dimensional (3D) templating in preoperative planning of total joint arthroplasty. METHODS: This scoping review followed the PRISMA, PRISMA-ScR guidelines, and five stage methodological framework for scoping reviews. Studies of patients undergoing primary or revision joint arthroplasty surgery that utilised AI-based 3D templating for surgical planning were included. Outcome measures included dataset and model development characteristics, AI performance metrics, and time performance. After AI-based 3D planning, the accuracy of component size and placement estimation and postoperative outcome data were collected. RESULTS: Nine studies satisfied inclusion criteria including a focus on computed tomography (CT) or magnetic resonance imaging (MRI)-based AI templating for use in hip or knee arthroplasty. AI-based 3D templating systems reduced surgical planning time and improved implant size/position and imaging feature estimation compared to conventional radiographic templating. Several components of data processing and model development and testing were insufficiently covered in the studies included in this scoping review. CONCLUSIONS: AI-based 3D templating systems have the potential to improve preoperative planning for joint arthroplasty surgery. This technology offers more accurate and personalized preoperative planning, which has potential to improve functional outcomes for patients. However, deficiencies in several key areas, including data handling, model development, and testing, can potentially hinder the reproducibility and reliability of the methods proposed. As such, further research is needed to definitively evaluate the efficacy and feasibility of these systems.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Inteligencia Artificial , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Cirugía Asistida por Computador/métodos , Cuidados Preoperatorios/métodos
9.
Artículo en Inglés | MEDLINE | ID: mdl-38874764

RESUMEN

BACKGROUND: Achieving adequate alignment has traditionally been an important goal in total knee arthroplasty to achieve long-term implant survival. While accelerometer-based hand-held navigation systems (ABN) has been introduced as a way to achieve alignment, there is a limited body of evidence on its accuracy, especially in patients under 65 years with differing etiologies for knee arthritis. This study aimed to assess the precision of a specific ABN system in restoring the mechanical axis and report surgical variables and complications, with particular attention to younger patients. METHODS: We conducted a retrospective review of 310 primary TKA performed with ABN from May 2016 to February 2021. The mean patient age was 67.4 (SD 8.9) years, with 43% under 65 years and mean body mass index of 33.2 (SD 6.8). The average surgical time was 96.8 min (57-171) and the average follow-up was 3.3 years (1.9-6.7). Data regarding length of stay, pain, range of motion (ROM), complications, and reinterventions were collected from the institutional joint arthroplasty registry and the medical records. Preoperative mechanical axis measurements and postoperative radiological data, including mechanical axis, component alignment and mechanical alignment outliers were analyzed. RESULTS: The mean preoperative mechanical axis was 175.4° (SD 7.6), with 248 knees (80%) in preoperative varus. The mean postoperative mechanical axis was 179.5° (SD 1.96) with 98% of knees falling within ± 3° of the neutral mechanical axis. Only 6 knees (2 varus, 4 valgus) fell outside the ± 3° range. And 3 knees (1 varus, 2 valgus) fell outside the ± 5° range. In the sagittal plane, 296 knees (95.5%) knees were within ± 3° of goal of 3 degrees of femoral flexion and 302 (97.4%) knees were within ± 2° of goal 1° of slope for tibial component. Far outliers (alignment outside ± 5° of targeted position) were found in 3 knees. Factors such as posttraumatic arthrosis, previous surgery, presence of retained hardware, and age below 65 years were not associated with increase in alignment outliers and far outliers. No complications related to the navigation system were observed. There were 22 complications and 20 reoperations, including 2 revisions for periprosthetic joint infection and 1 revision for flexion instability. Patients that required knee manipulation achieved an ultimate flexion of 110° (SD 14.1). CONCLUSIONS: The ABN system proved to be user-friendly and accurate in reducing alignment outliers in both coronal and sagittal planes in all patient populations. It offers a straightforward navigation solution while preserving surgeon autonomy and the use of traditional surgical tools. These findings advocate for the integration of this navigation system as a valuable tool to enhance the precision of TKA surgery in all patient groups.

10.
J Arthroplasty ; 38(10): 2051-2059.e2, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36265720

RESUMEN

BACKGROUND: Implementing tools that identify cost-saving opportunities for ambulatory orthopaedic surgeries can improve access to value-based care. We developed and internally validated a machine learning (ML) algorithm to predict cost drivers of total charges after ambulatory unicompartmental knee arthroplasty (UKA). METHODS: We queried the New York State Ambulatory Surgery and Services database to identify patients who underwent ambulatory, defined as <24 hours of care before discharge, elective UKA between 2014 and 2016. A total of 1,311 patients were included. The median costs after ambulatory UKA were $14,710. Patient demographics and intraoperative parameters were entered into 4 candidate ML algorithms. The most predictive model was selected following internal validation of candidate models, with conventional linear regression as a benchmark. Global variable importance and partial dependence curves were constructed to determine the impact of each input parameter on total charges. RESULTS: The gradient-boosted ensemble model outperformed all candidate algorithms and conventional linear regression. The major differential cost drivers of UKA identified (in decreasing order of magnitude) were increased operating room time, length of stay, use of regional and adjunctive periarticular analgesia, utilization of computer-assisted navigation, and routinely sending resected tissue to pathology. CONCLUSION: We developed and internally validated a supervised ML algorithm that identified operating room time, length of stay, use of computer-assisted navigation, regional primary anesthesia, adjunct periarticular analgesia, and routine surgical pathology as essential cost drivers of UKA. Following external validation, this tool may enable surgeons and health insurance providers optimize the delivery of value-based care to patients receiving outpatient UKA. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Pacientes Ambulatorios , Alta del Paciente , Aprendizaje Automático , Seguro de Salud , Osteoartritis de la Rodilla/cirugía , Resultado del Tratamiento , Articulación de la Rodilla/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA