RESUMEN
Background: Impressions that maintain their dimensional stability after autoclaving effectively control cross-infection and contamination resulting from a patient's oral secretions. Purpose: The study aimed to assess the dimensional stability of autoclavable polyvinyl siloxanes after disinfection and sterilization. Methods: A stainless steel metal model containing three full veneer crown preparations was fabricated according to ANSI/ADA specification No. 19. Reference grooves were established on the occlusal and axial surfaces of the abutments for accurate measurements. Forty impressions were created from the master model using single-step impression technique monophase polyvinyl siloxane material (AFFINIS, Coltene/Whaledent, Altstatten, Switzerland). The impressions were categorized into four groups: Group A (control, ten untreated impressions), Group B (ten disinfected impressions with 5.25 % sodium hypochlorite [NaOCl]), Group C (ten disinfected impressions with 2 % glutaraldehyde), and Group D (ten autoclaved impressions at 134 °C for 18 min). Subsequently, stone casts were produced using type IV gypsum products (Gelstone R, BK Giulini Chemie, Ludwigshafen/Rh., Germany). The dimensional accuracy of the obtained casts was assessed by measuring the inter-abutment measurements (between the abutments) and the intra-abutment measurements (diameter and height of the abutments). These measurements were performed using a universal measuring microscope (Olympus stereomicroscope B061 Imaging Corp. Tokyo, Japan) with a precision of 0.001 mm. The dimensions of the stone casts from the study groups were then compared to those of the control group. Data analysis was performed using a one-way ANOVA with a significance level of α = 0.05. Results: AFFINIS impressions subjected to chemical disinfection in 5.25 % NaOCl and 2 % glutaraldehyde with different immersion times showed slight expansion in the intra- and inter-abutment measurements. The impressions autoclaved at 134 °C for 18 min showed slight shrinkage in the intra- and inter-abutment measurements. The dimensional change was statistically non-significant, and the percent of dimensional changes within the experimental groups was within the clinically accepted limit (α < 0.5). Conclusion: AFFINIS polyvinyl siloxanes retain dimensional stability suitable for clinical use when subjected to chemical disinfection and steam autoclaving.
RESUMEN
Urine-derived stem cells (USCs) have gained the attention of researchers in the biomedical field in the past few years . Regarding the several varieties of cells that have been used for this purpose, USCs have demonstrated mesenchymal stem cell-like properties, such as differentiation and immunomodulation. Furthermore, they could be differentiated into several lineages. This is very interesting for regenerative techniques based on cell therapy. This review will embark on describing their separation, and profiling. We will specifically describe the USCs characteristics, in addition to their differentiation potential. Then, we will introduce and explore the primary uses of USCs. These involve thier utilization as a platform to produce stem cells, however, we shall concentrate on the utilization of USCs for therapeutic, and regenerative orofacial applications, providing an in-depth evaluation of this purpose. The final portion will address the limitations and challenges of their implementation in regenerative dentistry.
Asunto(s)
Medicina Regenerativa , Células Madre , Humanos , Células Madre/citología , Medicina Regenerativa/métodos , Animales , Orina/citología , Diferenciación Celular , Procedimientos de Cirugía Plástica/métodos , Regeneración/fisiología , Trasplante de Células Madre/métodos , Ingeniería de Tejidos/métodos , Células Madre Mesenquimatosas/citologíaRESUMEN
Nano carriers have gained more attention for their possible medical and technological applications. Tailored nanomaterials can transport medications efficiently to targeted areas and allow for sustained medication discharge, reducing undesirable toxicities while boosting curative effectiveness. Nonetheless, transitioning nanomedicines from experimental to therapeutic applications has proven difficult, so different pharmaceutical incorporation approaches in nano scaffolds are discussed. Then numerous types of nanobiomaterials implemented as carriers and their manufacturing techniques are explored. This article is also supported by various applications of nanobiomaterials in the biomedical field.
Asunto(s)
Materiales Biocompatibles , Sistemas de Liberación de Medicamentos , Ingeniería de Tejidos , Ingeniería de Tejidos/métodos , Humanos , Materiales Biocompatibles/química , Sistemas de Liberación de Medicamentos/métodos , Animales , Nanoestructuras/química , Nanomedicina/métodos , Portadores de Fármacos/química , Andamios del Tejido/químicaRESUMEN
Periodontitis is an inflammation-related condition, caused by an infectious microbiome and host defense that causes damage to periodontium. The natural processes of the mouth, like saliva production and eating, significantly diminish therapeutic medication residency in the region of periodontal disease. Furthermore, the complexity and diversity of pathological mechanisms make successful periodontitis treatment challenging. As a result, developing enhanced local drug delivery technologies and logical therapy procedures provides the foundation for effective periodontitis treatment. Being biocompatible, biodegradable, and easily administered to the periodontal tissues, hydrogels have sparked substantial an intense curiosity in the discipline of periodontal therapy. The primary objective of hydrogel research has changed in recent years to intelligent thermosensitive hydrogels, that involve local adjustable sol-gel transformations and regulate medication release in reaction to temperature, we present a thorough introduction to the creation and efficient construction of new intelligent thermosensitive hydrogels for periodontal regeneration. We also address cutting-edge smart hydrogel treatment options based on periodontitis pathophysiology. Furthermore, the problems and prospective study objectives are reviewed, with a focus on establishing effective hydrogel delivery methods and prospective clinical applications.
RESUMEN
Honeybees have been helpful insects since ancient centuries, and this benefit is not limited to being a honey producer only. After the bee stings a person, pain, and swelling occur in this place, due to the effects of bee venom (BV). This is not a poison in the total sense of the word because it has many benefits, and this is due to its composition being rich in proteins, peptides, enzymes, and other types of molecules in low concentrations that show promise in the treatment of numerous diseases and conditions. BV has also demonstrated positive effects against various cancers, antimicrobial activity, and wound healing versus the human immunodeficiency virus (HIV). Even though topical BV therapy is used to varying degrees among countries, localized swelling or itching are common side effects that may occur in some patients. This review provides an in-depth analysis of the complex chemical composition of BV, highlighting the diverse range of bioactive compounds and their therapeutic applications, which extend beyond the well-known anti-inflammatory and pain-relieving effects, showcasing the versatility of BV in modern medicine. A specific search strategy was followed across various databases; Web of sciences, Scopus, Medline, and Google Scholar including in vitro and in vivo clinical studies.to outline an overview of BV composition, methods to use, preparation requirements, and Individual consumption contraindications. Furthermore, this review addresses safety concerns and emerging approaches, such as the use of nanoparticles, to mitigate adverse effects, demonstrating a balanced and holistic perspective. Importantly, the review also incorporates historical context and traditional uses, as well as a unique focus on veterinary applications, setting it apart from previous works and providing a valuable resource for researchers and practitioners in the field.
RESUMEN
OBJECTIVE: The current study was designed to assess the bonding strength of EndoSeal MTA and AH Plus sealers after using three irrigation protocols as follows: (1) 17% Ethylenediamine tetraacetic acid, (2) 7% maleic acid, and (3) 37% phosphoric acid. MATERIALS AND METHODS: Push-out bond strength was evaluated for 60 middle root slices of 1-mm thickness each. They were horizontally cut from freshly extracted single-rooted human teeth. A hole in the root canal was made using a carbide round bur of 1.1 mm in diameter in a middle third root slice. Specimens were dipped in 2.5% NaOCl, and then they were grouped into three groups; G1: 17% EDTA, G2: 7% maleic acid, and G3: 37% phosphoric acid as a final irrigant for 3 minutes. Each group was subdivided into two subgroups, according to the type of sealer, either EndoSeal MTA or AH Plus. STATISTICAL ANALYSIS: After the full set of the sealer, the bond strength was evaluated with the push-out test by applying a force to each slice using a plunger with a 1-mm diameter. The one-way Tukey's post hoc test, analysis of variance (ANOVA) test, and Student's t-test were utilized to gather data and statistically evaluate it. RESULTS: The irrigation protocol used exhibited significant influence on the bond strength of EndoSeal MTA and AH Plus sealers. AH Plus sealer subgroups showed the highest bond strength with 7% maleic acid, followed by 37% phosphoric acid, and 17% EDTA. While in the EndoSeal MTA sealer subgroups, the highest bond strength was shown with the 17% EDTA followed by 7% maleic acid and 37% phosphoric acid, respectively. CONCLUSION: The present study revealed that the type of the final irrigant significantly impacts the bond strength of the sealer used. The AH Plus sealer bond strength was improved by using the 7% maleic acid as a final irrigant. In contrast, the EndoSeal MTA sealer showed the best results with the 17% EDTA as a final irrigant.
RESUMEN
Pressable ceramic restorations have been introduced and investigated, and found comparable to CAD/CAM ceramic in terms of mechanical properties; however, the effect of toothbrushing on the pressable ceramic has not been thoroughly investigated. The objective of the current study was to assess the effect of artificial toothbrushing simulation on the surface roughness, microhardness, and color stability of different ceramic materials. Three lithium disilicate-based ceramics (IPS Emax CAD [EC], IPS Emax Press [EP]; (Ivoclar Vivadent AG), and LiSi Press [LP] (GC Corp, Tokyo, Japan)) were examined. For each ceramic material, eight bar-shaped specimens were prepared and subjected to 10,000 brushing cycles. Surface roughness, microhardness, and color stability (∆E) were measured before and after brushing. Scanning electron microscopy (SEM) was used for surface profile analysis. The results were analyzed using one-way ANOVA, Tukey's post hoc test, and paired sample t-test α = 0.05. The findings revealed a non-significant decrease in the surface roughness of EC, EP, and LP groups (p > 0.05), and both LP and EP have the lowest surface roughness values (0.64 ± 0.13, 0.64 ± 0.08 µm) after brushing, respectively. Toothbrushing showed a decrease in the microhardness of the three groups: EC and LP, p < 0.001; EP, p = 0.012). EP showed the lowest hardness value after brushing (862.45 ± 273.83). No significant changes (∆E) were observed in all groups (p > 0.05); however, the EC group was found to be considerably affected by color changes, in comparison to the EC and LP groups. Toothbrushing had no effect on surface roughness and color stability of all tested materials, but it decreased the microhardness. Material type, surface treatments, and glazing of ceramic materials contributed to the surface changes in the ceramic materials, necessitating further investigations in terms of the toothbrushing effect with different glazing as variables.
RESUMEN
Background: Successful root canal treatment is influenced by the apical extent of root canal preparation and the eventual root canal filling. Achieving the full working length until the apical constriction, which is usually 0.5 - 1 mm shorter than the anatomical apex, is crucial. Electronic apex locators were used to detect the working length more accurately. There are six generations of electronic apex locators in the market. The selection of the appropriate irrigation with each apex locator for accurate working length determination is not fully investigated. Methods: The actual working lengths of 120 freshly extracted human single-rooted teeth were measured and compared with their working lengths using 3 rd generation (Root ZX) followed by 6 th generation (Raypex 6) apex locators in dry medium, presence of 5.25% sodium hypochlorite, and 2% chlorhexidine, without coronal pre-flaring and after coronal pre-flaring using the same irrigating media. Data were collected, tabulated, and afterward analyzed using one-way ANOVA with post-hoc to evaluate the significant difference in average working length between actual working length, Root ZX, and Raypex 6 apex locator working lengths accuracy. Results: The significant results were shown in roots that were coronally pre-flared and their working lengths were measured in a dry medium using Raypex 6 apex locator. While using the Root ZX apex locator, the most accurate results were shown in roots that were coronally pre-flared and their working lengths were measured while using a chlorhexidine irrigating solution. Conclusions: It is concluded that it is very important to know the specific irrigating medium to be used with each specific electronic apex locator to achieve the most accurate working length results.
Asunto(s)
Clorhexidina , Ápice del Diente , Humanos , Cavidad Pulpar , Odontometría , ElectrónicaRESUMEN
Three-dimensionally (3D)-printed fabricated denture bases have shown inferior strength to conventional and subtractively fabricated ones. Several factors could significantly improve the strength of 3D-printed denture base resin, including the addition of nanoparticles and post-curing factors. This study evaluated the effect of TiO2 nanoparticle (TNP) addition and the post-curing time (PCT) on the flexural properties and hardness of three-dimensionally (3D)-printed denture base resins. A total of 360 specimens were fabricated, with 180 specimens from each type of resin. For evaluating the flexural properties, bar-shaped specimens measuring 64 × 10 × 3.3 mm were used, while, for the hardness testing, disc-shaped specimens measuring 15 × 2 mm were employed. The two 3D-printed resins utilized in this study were Asiga (DentaBASE) and NextDent (Vertex Dental B.V). Each resin was modified by adding TNPs at 1% and 2% concentrations, forming two groups and an additional unmodified group. Each group was divided into three subgroups according to the PCT (15, 60, and 90 min). All the specimens were subjected to artificial aging (5000 cycles), followed by testing of the flexural strength and elastic modulus using a universal testing machine, and the hardness using the Vickers hardness test. A three-way ANOVA was used for the data analysis, and a post hoc Tukey's test was used for the pairwise comparisons (α = 0.05). Scanning electron microscopy (SEM) was used for the fracture surface analysis. The addition of the TNPs increased the flexural strength in comparison to the unmodified groups (p < 0.001), while there was no significant difference in the elastic modulus and hardness with the 1% TNP concentration. Among the TNP groups, the 2% TNP concentration significantly decreased the elastic modulus and hardness (p < 0.001). The SEM showed a homogenous distribution of the TNPs, and the more irregular fracture surface displayed ductile fractures. The PCT significantly increased the flexural strength, elastic modulus, and hardness (p < 0.001), and this increase was time-dependent. The three-way ANOVA results revealed a significant difference between the material types, TNP concentrations, and PCT interactions (p < 0.001). Both concentrations of the TNPs increased the flexural strength, while the 2% TNP concentration decreased the elastic modulus and hardness of the 3D-printed nanocomposites. The flexural strength and hardness increased as the PCT increased. The material type, TNP concentration, and PCT are important factors that affect the strength of 3D-printed nanocomposites and could improve their mechanical performance.
RESUMEN
Polyether-ether-ketone (PEEK) biomaterial has been increasingly employed for orthopedic, trauma, spinal, and dental implants due to its biocompatibility and in vivo stability. However, a lack of bioactivity and binding ability to natural bone tissue has significantly limited PEEK for many challenging dental implant applications. In this work, nanocomposites based on PEEK reinforced with bioactive silicate-based bioceramics (forsterite or bioglass) as nanofillers were prepared using high energy ball milling followed by melt blending and compression molding. The influence of nanofillers type and content (10, 20 and 30 wt.%) on the crystalline structure, morphology, surface roughness, hydrophilicity, microhardness, elastic compression modulus, and flexural strength of the nanocomposites was investigated. The scanning electron microscopy images of the nanocomposites with low nanofillers content showed a homogenous surface with uniform dispersion within the PEEK matrix with no agglomerates. All nanocomposites showed an increased surface roughness compared to pristine PEEK. It was found that the incorporation of 20 wt.% forsterite was the most effective in the nanocomposite formulation compared with bioglass-based nanocomposites; it has significantly improved the elastic modulus, flexural strength, and microhardness. In vitro bioactivity evaluation, which used biomimetic simulated body fluid indicated the ability of PEEK nanocomposites loaded with forsterite or bioglass nanofillers to precipitate calcium and phosphate bone minerals on its surface. These nanocomposites are expected to be used in long-term load-bearing implant applications and could be recommended as a promising alternative to titanium and zirconia when used as a dental implant material.