Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Knee Surg ; 20(3): 241-4, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17665788

RESUMEN

The Anatomic Modular Knee (AMK; Depuy, Warsaw, Ind) was one of the first designs to incorporate a modular locking mechanism for the tibial insert; fixation was secured using a screw-in tibial tray-locking pin. This case report describes a patient who presented with instability and worsening knee pain 15 years following a primary total knee arthroplasty using the AMK prosthesis. Radiographs and intraoperative assessment revealed proximal migration of the tibial tray-locking pin into the medial femoral condyle resulting in a large osteolytic defect.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Clavos Ortopédicos/efectos adversos , Fémur/diagnóstico por imagen , Migración de Cuerpo Extraño/complicaciones , Osteólisis Esencial/etiología , Artralgia/etiología , Artralgia/cirugía , Artroplastia de Reemplazo de Rodilla/instrumentación , Fémur/cirugía , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/cirugía , Humanos , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteólisis Esencial/diagnóstico por imagen , Osteólisis Esencial/cirugía , Falla de Prótesis , Radiografía , Reoperación
2.
J Arthroplasty ; 22(3): 356-62, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17400091

RESUMEN

Currently, there are several femoral stem designs available for use, but few have an extended track record. We have previously reported on 10- and 15-year outcome studies of total hip arthroplasty (THA) using a cemented normalized and proportionalized femoral stem from a single surgeon series. This is a follow-up study reporting the minimum 20-year outcome of this femoral stem design. The study began with THA performed in a consecutive series of 184 patients; stem fixation was achieved using first-generation cementing techniques. The overall early complication rate was 10%. There were 23 patients (31 hips) who had been followed-up for a minimum 20-year period (average 21.3 years). Mean d'Aubigne and Postel scores improved from 5.9 to 11.3; mean Harris hip scores improved from 43.8 to 92.8. Kaplan-Meier survivorship was 93% at 20 years (95% confidence interval); there were no stem failures. The use of a cemented normalized and proportionalized femoral stem in primary THA provides satisfactory long-term clinical and radiological outcomes in patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Adulto , Anciano , Análisis de Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Diseño de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA