Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Wellcome Open Res ; 5: 162, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-35330938

RESUMEN

Background: The global COVID-19 outbreak relies on a quantitative real-time polymerase chain reaction (qRT-PCR) for the detection of severe acute respiratory syndrome coronavirus (SARS-CoV-2), to facilitate the roll-out of patient care and infection control measures. There are several qRT-PCR assays with little evidence on their comparability. We report alterations to the developers' recommendations to sustain the testing capability in our setting, where the supply of testing reagents is limited. Methods: Standards generated from a serially-diluted positive control and previously identified positive/negative samples were used to determine the optimal volumes of the qRT-PCR reagents and to evaluate the validity and performance of four assays: Charité Berlin and European Virus Archive - GLOBAL (EVAg) primer-probe sets, and DAAN and Beijing Genomics Institute (BGI) premixed commercial kits. A multiplex and singleplex RT-PCR kit was used with the two primer-probe sets and the recommended assay volumes of the two premixed kits were altered. Results: In comparison to the multiplex RT-PCR kit, the singleplex RT-PCR kit combined with the primer-probe sets yielded consistent cycle threshold (Ct) values across the different titrations tested. The DAAN premixed kit produced comparable Ct values across the titrations, while the BGI kit showed incomparable Ct values and inconsistent results between batches using the manufacturer's recommended volumes. Conclusion: We achieved a 2.5-fold and 4-fold increase in the number of tests/kit for the premixed kits and the primer-probe sets, respectively. The primer-probe set assays were reliable and consistent, and we preferred a combination of an EVAg and a Berlin target. Any inconclusive result was repeated by different individuals following the same protocol. DAAN was a consistent and reliable assay even at lower concentrations from the stated recommendations. BGI in contrast, required dilution to improve its performance and was hence an assay that was used in combination with EVAg or Berlin targets.

2.
Pan Afr Med J ; 23: 12, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27200121

RESUMEN

INTRODUCTION: Safe water for human consumption is important, but there is a limited supply. Mombasa County has water shortages making residences rely on other sources of water including boreholes and wells. Microbiological evaluation of drinking water is important to reduce exposure to water borne enteric diseases. This cross sectional study aimed at determining the frequency and characterization of Escherichia coli (E. coli) pathotypes from water samples collected from wells and boreholes in Mombasa County. METHODS: One hundred and fifty seven (157) water samples were collected from four divisions of the county and a questionnaire administered. The samples were inoculated to double strength MacConkey broth and incubated at 370C for up to 48 hours. Positive results were compared to the 3 tube McCrady MPN table. The E. coli were confirmed by Eijkman's test and antibiotic susceptibility carried out. Using polymerase chain reaction (PCR), the E. coli were characterized to establish pathotypes. RESULTS: One hundred and thirty one (n = 131; 83.4%) samples had coliform bacteria with only 79 (60.3%) samples having E. coli. Significant values (<0.05) were noted when coliforms were compared to variables with E. Coli showing no significance when compared to similar variables. E. coli (n = 77; 100%) tested were sensitive to Gentamicin, while all (n = 77; 100%) isolates were resistant to Ampicillin. PCR typed isolates as enteroinvasive E. Coli (EIEC). CONCLUSION: Findings suggest that coliforms and E. coli are major contaminants of wells and boreholes in Mombasa County. The isolates have a variety of resistant and sensitivity patterns to commonly used antibiotics.


Asunto(s)
Escherichia coli/aislamiento & purificación , Microbiología del Agua , Abastecimiento de Agua/normas , Pozos de Agua , Antibacterianos/farmacología , Estudios Transversales , Agua Potable/microbiología , Escherichia coli/efectos de los fármacos , Humanos , Kenia , Pruebas de Sensibilidad Microbiana , Reacción en Cadena de la Polimerasa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA