Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Environ Res ; 251(Pt 2): 118629, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38490626

RESUMEN

BACKGROUND: A knowledge gap exists regarding longitudinal assessment of personal radio-frequency electromagnetic field (RF-EMF) exposures globally. It is unclear how the change in telecommunication technology over the years translates to change in RF-EMF exposure. This study aims to evaluate longitudinal trends of micro-environmental personal RF-EMF exposures in Australia. METHODS: The study utilised baseline (2015-16) and follow-up (2022) data on personal RF-EMF exposure (88 MHz-6 GHz) measured across 18 micro-environments in Melbourne. Simultaneous quantile regression analysis was conducted to compare exposure data distribution percentiles, particularly median (P50), upper extreme value (P99) and overall exposure trends. RF-EMF exposures were compared across six exposure source types: mobile downlink, mobile uplink, broadcast, 5G-New Radio, Others and Total (of the aforementioned sources). Frequency-specific exposures measured at baseline and follow-up were compared. Total exposure across different groups of micro-environment types were also compared. RESULTS: For all micro-environmental data, total (median and P99) exposure levels did not significantly change at follow-up. Overall exposure trend of total exposure increased at follow-up. Mobile downlink contributed the highest exposure among all sources showing an increase in median exposure and overall exposure trend. Of seven micro-environment types, five of them showed total exposure levels (median and P99) and overall exposure trend increased at follow-up.


Asunto(s)
Campos Electromagnéticos , Exposición a Riesgos Ambientales , Ondas de Radio , Campos Electromagnéticos/efectos adversos , Ondas de Radio/efectos adversos , Humanos , Estudios Longitudinales , Victoria , Australia
2.
Risk Anal ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38774944

RESUMEN

There is an unprecedented exposure of living organisms to mobile communications radiofrequency electromagnetic field (RF-EMF) emissions. Guidelines on exposure thresholds to limit thermal effects from these emissions are restricted to humans. However, tissue heating can occur in all living organisms that are exposed. In addition, exposure at millimetric frequencies used by 5G may impact surface tissues and organs of plants and small-size species. It is also expected that the addition of 5G to existing networks will intensify radiofrequency absorption by living organisms. A European Parliament report proposed policy options on the effects of RF-EMF exposure of plants, animals, and other living organisms in the context of 5G: funding more research, implementing monitoring networks, accessing more information from operators on antennas and EMF emissions, and developing compliance studies when antennas are installed. However, there is no evidence on the preferences of relevant stakeholders regarding these policy options. This paper reports the findings of a survey of key European stakeholders' policy option preferences based on the European Parliament's report. It reveals a broad consensus on funding more research on the effects of exposure of plants, animals, and other living organisms to EMFs. It also highlights the need for deliberation concerning the other policy options that could provide solutions for regulatory authorities, central administrations, the private sector, nongovernmental associations and advocates, and academics. Such deliberation would pave the way for effective solutions, focusing on long-term output from funding research, and enabling short-term socially and economically acceptable actions for all parties concerned.

3.
Sensors (Basel) ; 24(4)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38400278

RESUMEN

Commercial, high-tech upper limb prostheses offer a lot of functionality and are equipped with high-grade control mechanisms. However, they are relatively expensive and are not accessible to the majority of amputees. Therefore, more affordable, accessible, open-source, and 3D-printable alternatives are being developed. A commonly proposed approach to control these prostheses is to use bio-potentials generated by skeletal muscles, which can be measured using surface electromyography (sEMG). However, this control mechanism either lacks accuracy when a single sEMG sensor is used or involves the use of wires to connect to an array of multiple nodes, which hinders patients' movements. In order to mitigate these issues, we have developed a circular, wireless s-EMG array that is able to collect sEMG potentials on an array of electrodes that can be spread (not) uniformly around the circumference of a patient's arm. The modular sEMG system is combined with a Bluetooth Low Energy System on Chip, motion sensors, and a battery. We have benchmarked this system with a commercial, wired, state-of-the-art alternative and found an r = 0.98 (p < 0.01) Spearman correlation between the root-mean-squared (RMS) amplitude of sEMG measurements measured by both devices for the same set of 20 reference gestures, demonstrating that the system is accurate in measuring sEMG. Additionally, we have demonstrated that the RMS amplitudes of sEMG measurements between the different nodes within the array are uncorrelated, indicating that they contain independent information that can be used for higher accuracy in gesture recognition. We show this by training a random forest classifier that can distinguish between 6 gestures with an accuracy of 97%. This work is important for a large and growing group of amputees whose quality of life could be improved using this technology.


Asunto(s)
Amputados , Miembros Artificiales , Humanos , Electromiografía , Calidad de Vida , Músculo Esquelético/fisiología , Gestos , Mano/fisiología
4.
PLoS Comput Biol ; 17(10): e1009460, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34710086

RESUMEN

Fifth generation networks (5G) will be associated with a partial shift to higher carrier frequencies, including wavelengths comparable in size to insects. This may lead to higher absorption of radio frequency (RF) electromagnetic fields (EMF) by insects and could cause dielectric heating. The yellow fever mosquito (Aedes aegypti), a vector for diseases such as yellow and dengue fever, favors warm climates. Being exposed to higher frequency RF EMFs causing possible dielectric heating, could have an influence on behavior, physiology and morphology, and could be a possible factor for introduction of the species in regions where the yellow fever mosquito normally does not appear. In this study, the influence of far field RF exposure on A. aegypti was examined between 2 and 240 GHz. Using Finite Difference Time Domain (FDTD) simulations, the distribution of the electric field in and around the insect and the absorbed RF power were found for six different mosquito models (three male, three female). The 3D models were created from micro-CT scans of real mosquitoes. The dielectric properties used in the simulation were measured from a mixture of homogenized A. aegypti. For a given incident RF power, the absorption increases with increasing frequency between 2 and 90 GHz with a maximum between 90 and 240 GHz. The absorption was maximal in the region where the wavelength matches the size of the mosquito. For a same incident field strength, the power absorption by the mosquito is 16 times higher at 60 GHz than at 6 GHz. The higher absorption of RF power by future technologies can result in dielectric heating and potentially influence the biology of this mosquito.


Asunto(s)
Aedes , Mosquitos Vectores , Ondas de Radio , Aedes/fisiología , Aedes/efectos de la radiación , Animales , Femenino , Calor , Masculino , Mosquitos Vectores/fisiología , Mosquitos Vectores/efectos de la radiación , Fiebre Amarilla/transmisión
5.
Environ Res ; 204(Pt C): 112291, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34757029

RESUMEN

OBJECTIVE: To investigate the association of estimated all-day and evening whole-brain radiofrequency electromagnetic field (RF-EMF) doses with sleep disturbances and objective sleep measures in preadolescents. METHODS: We included preadolescents aged 9-12 years from two population-based birth cohorts, the Dutch Generation R Study (n = 974) and the Spanish INfancia y Medio Ambiente Project (n = 868). All-day and evening overall whole-brain RF-EMF doses (mJ/kg/day) were estimated for several RF-EMF sources including mobile and Digital Enhanced Cordless Telecommunications (DECT) phone calls (named phone calls), other mobile phone uses, tablet use, laptop use (named screen activities), and far-field sources. We also estimated all-day and evening whole-brain RF-EMF doses in these three groups separately (i.e. phone calls, screen activities, and far-field). The Sleep Disturbance Scale for Children was completed by mothers to assess sleep disturbances. Wrist accelerometers together with sleep diaries were used to measure sleep characteristics objectively for 7 consecutive days. RESULTS: All-day whole-brain RF-EMF doses were not associated with self-reported sleep disturbances and objective sleep measures. Regarding evening doses, preadolescents with high evening whole-brain RF-EMF dose from phone calls had a shorter total sleep time compared to preadolescents with zero evening whole-brain RF-EMF dose from phone calls [-11.9 min (95%CI -21.2; -2.5)]. CONCLUSIONS: Our findings suggest the evening as a potentially relevant window of RF-EMF exposure for sleep. However, we cannot exclude that observed associations are due to the activities or reasons motivating the phone calls rather than the RF-EMF exposure itself or due to chance finding.


Asunto(s)
Teléfono Celular , Campos Electromagnéticos , Encéfalo , Niño , Campos Electromagnéticos/efectos adversos , Exposición a Riesgos Ambientales , Humanos , Ondas de Radio/efectos adversos , Sueño
6.
Sensors (Basel) ; 22(18)2022 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-36146205

RESUMEN

This paper describes the exploration of the combined antenna-channel model for a horse hoof. An antenna of 25 mm × 40 mm is designed in the ISM 868 MHz band. During the characterization and design of the antenna, the dynamic and harsh environment of the horse hoof is taken into account throughout every step of the procedure because it is impossible to de-embed the antenna from its environment. The antenna and channel model are verified extensively by measurements in phantom and ex vivo. The antenna is verified to be robust against changes in the morphology of the horse's hoof up to 50%. The dynamic environment was captured by considering different soil types and air, and the design was verified to be resilient against changes herein. The antenna performs well within the targeted band, with a fractional bandwidth of 8% and a gain of -2 dBi. Furthermore, a path loss model was constructed for a typical barn environment, and the antenna reaches a range of 250 m in the studied environment based on the LoRa technology. This research is important for monitoring horse health.


Asunto(s)
Pezuñas y Garras , Tecnología Inalámbrica , Animales , Diseño de Equipo , Caballos , Fantasmas de Imagen , Suelo
7.
Sensors (Basel) ; 22(5)2022 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-35270862

RESUMEN

In an increasingly wireless world, spatiotemporal monitoring of the exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) is crucial to appease public uncertainty and anxiety about RF-EMF. However, although the advent of smart city infrastructures allows for dense networks of distributed sensors, the costs of accurate RF sensors remain high, and dedicated RF monitoring networks remain rare. This paper describes a comprehensive study comprising the design of a low-cost RF-EMF sensor node capable of monitoring four frequency bands used by wireless telecommunications with an unparalleled temporal resolution, its application in a small-scale distributed sensor network consisting of both fixed (on building façades) and mobile sensor nodes (on postal vans), and the subsequent analysis of over a year of data between January 2019 and May 2020, during which slightly less than 10 million samples were collected. From the fixed nodes' results, the potential errors were determined that are induced when sampling at lower speeds (e.g., one sample per 15 min) and measuring for shorter periods of time (e.g., a few weeks), as well as an adequate resolution (30 min) for diurnal and weekly temporal profiles which sufficiently preserves short-term variations. Furthermore, based on the correlation between the sensors, an adequate density of 100 sensor nodes per km2 was deduced for future networks. Finally, the mobile sensor nodes were used to identify potential RF-EMF exposure hotspots in a previously unattainable area of more than 60 km2. In summary, through the analysis of a small number of RF-EMF sensor nodes (both fixed and mobile) in an urban area, this study offers invaluable insights applicable to future designs and deployments of distributed RF-EMF sensor networks.


Asunto(s)
Teléfono Celular , Campos Electromagnéticos , Ciudades , Exposición a Riesgos Ambientales/análisis , Ondas de Radio
8.
Environ Res ; 193: 110505, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33245886

RESUMEN

BACKGROUND: Little is known about radiofrequency electromagnetic fields (RF) from mobile technology and resulting dose in young people. We describe modeled integrated RF dose in European children and adolescents combining own mobile device use and surrounding sources. METHODS: Using an integrated RF model, we estimated the daily RF dose in the brain (whole-brain, cerebellum, frontal lobe, midbrain, occipital lobe, parietal lobe, temporal lobes) and the whole-body in 8358 children (ages 8-12) and adolescents (ages 14-18) from the Netherlands, Spain, and Switzerland during 2012-2016. The integrated model estimated RF dose from near-field sources (digital enhanced communication technology (DECT) phone, mobile phone, tablet, and laptop) and far-field sources (mobile phone base stations via 3D-radiowave modeling or RF measurements). RESULTS: Adolescents were more frequent mobile phone users and experienced higher modeled RF doses in the whole-brain (median 330.4 mJ/kg/day) compared to children (median 81.8 mJ/kg/day). Children spent more time using tablets or laptops compared to adolescents, resulting in higher RF doses in the whole-body (median whole-body dose of 81.8 mJ/kg/day) compared to adolescents (41.9 mJ/kg/day). Among brain regions, temporal lobes received the highest RF dose (medians of 274.9 and 1786.5 mJ/kg/day in children and adolescents, respectively) followed by the frontal lobe. In most children and adolescents, calling on 2G networks was the main contributor to RF dose in the whole-brain (medians of 31.1 and 273.7 mJ/kg/day, respectively). CONCLUSION: This first large study of RF dose to the brain and body of children and adolescents shows that mobile phone calls on 2G networks are the main determinants of brain dose, especially in temporal and frontal lobes, whereas whole-body doses were mostly determined by tablet and laptop use. The modeling of RF doses provides valuable input to epidemiological research and to potential risk management regarding RF exposure in young people.


Asunto(s)
Teléfono Celular , Campos Electromagnéticos , Adolescente , Encéfalo , Niño , Comunicación , Exposición a Riesgos Ambientales , Humanos , Países Bajos , Ondas de Radio , España , Suiza
9.
Environ Health ; 20(1): 36, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33794922

RESUMEN

BACKGROUND: The general population is exposed to Radio-Frequency Electromagnetic Fields (RF-EMFs) used by telecommunication networks. Previous studies developed methods to assess this exposure. These methods will be inadequate to accurately assess exposure in 5G technologies or other wireless technologies using adaptive antennas. This is due to the fact that 5G NR (new radio) base stations will focus actively on connected users, resulting in a high spatio-temporal variations in the RF-EMFs. This increases the measurement uncertainty in personal measurements of RF-EMF exposure. Furthermore, a user's exposure from base stations will be dependent on the amount of data usage, adding a new component to the auto-induced exposure, which is often omitted in current studies. GOALS: The objective of this paper is to develop a general study protocol for future personal RF-EMF exposure research adapted to 5G technologies. This protocol will include the assessment of auto-induced exposure of both a user's own devices and the networks' base stations. METHOD: This study draws from lessons learned from previous RF-EMF exposure research and current knowledge on 5G technologies, including studies simulating 5G NR base stations and measurements around 5G NR test sites. RESULTS: To account for auto-induced exposure, an activity-based approach is introduced. In survey studies, an RF-EMF sensor is fixed on the participants' mobile device(s). Based on the measured power density, GPS data and movement and proximity sensors, different activities can be clustered and the exposure during each activity is evaluated. In microenvironmental measurements, a trained researcher performs measurements in predefined microenvironments with a mobile device equipped with the RF-EMF sensor. The mobile device is programmed to repeat a sequence of data transmission scenarios (different amounts of uplink and downlink data transmissions). Based on simulations, the amount of exposure induced in the body when the user device is at a certain location relative to the body, can be evaluated. CONCLUSION: Our protocol addresses the main challenges to personal exposure measurement introduced by 5G NR. A systematic method to evaluate a user's auto-induced exposure is introduced.


Asunto(s)
Redes de Comunicación de Computadores , Campos Electromagnéticos , Monitoreo del Ambiente/métodos , Ondas de Radio , Computadoras de Mano , Humanos
10.
Environ Res ; 175: 351-366, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31150934

RESUMEN

Personal exposure to Radio-Frequency Electromagnetic Fields (RF-EMFs) was studied using personal measurements in five different microenvironments in each of five cities (Brussels, Antwerp, Ghent, Bruges and Hasselt) in Flanders, Belgium. These measurements were carried out by two researchers using on-body calibrated personal exposimeters. In three out of the five studied cities (Brussels, Ghent and Bruges), temporal aspects of personal exposure to RF-EMFs were studied as well. Measurements during and outside of rush hours (7:00-9:15 and 16:30-19:00) were compared. Likewise, measurements were executed during night time and compared to the ones measured during working hours. Representativeness and repeatability of the measurement method was studied as well. The highest mean total exposure was found in Brussels (2.63 mW/m2), the most densely populated city in this study. However, we measured higher downlink exposure in Antwerp than in Brussels, which might be an effect of the stronger legislation on base stations in Brussels. The measurements and used protocol were found to be both repeatable over time (r = 0.95 for median total exposure) and representative for the studied microenvironments in terms of path selection (r = 0.88 for median total exposure). Finally, in 10 out of the 13 on-body calibrated frequency bands we found that the measurement devices underestimate the intensity of the incident RF-EMFs with median underestimations up to 68%.


Asunto(s)
Campos Electromagnéticos , Exposición a Riesgos Ambientales , Ondas de Radio , Bélgica , Teléfono Celular , Ciudades
11.
Environ Res ; 175: 1-10, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31096087

RESUMEN

When making phone calls, cellphone and smartphone users are exposed to radio-frequency (RF) electromagnetic fields (EMFs) and sound pressure simultaneously. Speech intelligibility during mobile phone calls is related to the sound pressure level of speech relative to potential background sounds and also to the RF-EMF exposure, since the signal quality is correlated with the RF-EMF strength. Additionally, speech intelligibility, sound pressure level, and exposure to RF-EMFs are dependent on how the call is made (on speaker, held at the ear, or with headsets). The relationship between speech intelligibility, sound exposure, and exposure to RF-EMFs is determined in this study. To this aim, the transmitted RF-EMF power was recorded during phone calls made by 53 subjects in three different, controlled exposure scenarios: calling with the phone at the ear, calling in speaker-mode, and calling with a headset. This emitted power is directly proportional to the exposure to RF EMFs and is translated into specific absorption rate using numerical simulations. Simultaneously, sound pressure levels have been recorded and speech intelligibility has been assessed during each phone call. The results show that exposure to RF-EMFs, quantified as the specific absorption in the head, will be reduced when speaker-mode or a headset is used, in comparison to calling next to the ear. Additionally, personal exposure to sound pressure is also found to be highest in the condition where the phone is held next to the ear. On the other hand, speech perception is found to be the best when calling with a phone next to the ear in comparison to the other studied conditions, when background noise is present.


Asunto(s)
Teléfono Celular , Campos Electromagnéticos , Ondas de Radio , Inteligibilidad del Habla , Teléfono Celular/instrumentación , Teléfono Celular/normas , Humanos , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control
12.
Environ Res ; 162: 81-96, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29289859

RESUMEN

The aims of this study were to: i) investigate the repeatability and representativeness of personal radio frequency-electromagnetic fields (RF-EMFs) exposure measurements, across different microenvironments, ii) perform simultaneous evaluations of personal RF-EMF exposures for the whole body and the head, iii) validate the data obtained with a head-worn personal distributed exposimeter (PDE) against those obtained with an on-body worn personal exposimeter (PEM). Data on personal and head RF-EMF exposures were collected by performing measurements across 15 microenvironments in Melbourne, Australia. A body-worn PEM and a head-worn PDE were used for measuring body and head exposures, respectively. The summary statistics obtained for total RF-EMF exposure showed a high representativeness (r2 > 0.66 for two paths in the same area) and a high repeatability over time (r2 > 0.87 for repetitions of the same path). The median head exposure in the 900MHz downlink band ranged between 0.06V/m and 0.31V/m. The results obtained during simultaneous measurements using the two devices showed high correlations (0.42 < r2 < 0.94). The highest mean total RF-EMF exposure was measured in Melbourne's central business district (0.89V/m), whereas the lowest mean total exposure was measured in a suburban residential area (0.05V/m). This study shows that personal RF-EMF microenvironmental measurements in multiple microenvironments have high representativeness and repeatability over time. The personal RF-EMF exposure levels (i.e. body and head exposures) demonstrated moderate to high correlations.


Asunto(s)
Campos Electromagnéticos , Exposición a Riesgos Ambientales , Monitoreo del Ambiente , Australia , Vivienda , Ondas de Radio , Reproducibilidad de los Resultados
13.
Sensors (Basel) ; 18(12)2018 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-30486453

RESUMEN

While there exists a wide variety of radio frequency (RF) technologies amenable for usage in Wireless Body Area Networks (WBANs), which have been studied separately before, it is currently still unclear how their performance compares in true on-body scenarios. In this paper, a single reference on-body scenario-that is, propagation along the arm-is used to experimentally compare six distinct RF technologies (between 420 MHz and 2.4 GHz) in terms of path loss. To further quantify on-body path loss, measurements for five different on-body scenarios are presented as well. To compensate for the effect of often large path losses, two mitigation strategies to (dynamically) improve on-body links are introduced and experimentally verified: beam steering using a phased array, and usage of on-body RF repeaters. The results of this study can serve as a tool for WBAN designers to aid in the selection of the right RF frequency and technology for their application.

14.
Sensors (Basel) ; 18(1)2018 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-29346280

RESUMEN

A multi-band Body-Worn Distributed exposure Meter (BWDM) calibrated for simultaneous measurement of the incident power density in 11 telecommunication frequency bands, is proposed. The BDWM consists of 22 textile antennas integrated in a garment and is calibrated on six human subjects in an anechoic chamber to assess its measurement uncertainty in terms of 68% confidence interval of the on-body antenna aperture. It is shown that by using multiple antennas in each frequency band, the uncertainty of the BWDM is 22 dB improved with respect to single nodes on the front and back of the torso and variations are decreased to maximum 8.8 dB. Moreover, deploying single antennas for different body morphologies results in a variation up to 9.3 dB, which is reduced to 3.6 dB using multiple antennas for six subjects with various body mass index values. The designed BWDM, has an improved uncertainty of up to 9.6 dB in comparison to commercially available personal exposure meters calibrated on body. As an application, an average incident power density in the range of 26.7-90.8 µW·m - 2 is measured in Ghent, Belgium. The measurements show that commercial personal exposure meters underestimate the actual exposure by a factor of up to 20.6.


Asunto(s)
Ondas de Radio , Bélgica , Calibración , Campos Electromagnéticos , Humanos , Monitoreo de Radiación , Incertidumbre
15.
Bioelectromagnetics ; 38(4): 295-306, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28240792

RESUMEN

In the future, wireless radiofrequency (RF) telecommunications networks will provide users with gigabit-per-second data rates. Therefore, these networks are evolving toward hybrid networks, which will include commonly used macro- and microcells in combination with local ultra-high density access networks consisting of so-called attocells. The use of attocells requires a proper compliance assessment of exposure to RF electromagnetic radiation. This paper presents, for the first time, such a compliance assessment of an attocell operating at 3.5 GHz with an input power of 1 mW, based on both root-mean-squared electric field strength (Erms ) and peak 10 g-averaged specific absorption rate (SAR10g ) values. The Erms values near the attocell were determined using finite-difference time-domain (FDTD) simulations and measurements by a tri-axial probe. They were compared to the International Commission on Non-Ionizing Radiation Protection's (ICNIRP) reference levels. All measured and simulated Erms values above the attocell were below 5.9 V/m and lower than reference levels. The SAR10g values were measured in a homogeneous phantom, which resulted in an SAR10g of 9.7 mW/kg, and used FDTD simulations, which resulted in an SAR10g of 7.2 mW/kg. FDTD simulations of realistic exposure situations were executed using a heterogeneous phantom, which yielded SAR10g values lower than 2.8 mW/kg. The studied dosimetric quantities were in compliance with ICNIRP guidelines when the attocell was fed an input power <1 mW. The deployment of attocells is thus a feasible solution for providing broadband data transmission without drastically increasing personal RF exposure. Bioelectromagnetics. 38:295-306, 2017. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Redes de Comunicación de Computadores , Exposición a la Radiación/análisis , Ondas de Radio , Absorción de Radiación , Humanos , Modelos Teóricos , Fantasmas de Imagen , Tecnología Inalámbrica
16.
Environ Res ; 151: 547-563, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27588949

RESUMEN

The purposes of this study were: i) to demonstrate the assessment of personal exposure from various RF-EMF sources across different microenvironments in Australia and Belgium, with two on-body calibrated exposimeters, in contrast to earlier studies which employed single, non-on-body calibrated exposimeters; ii) to systematically evaluate the performance of the exposimeters using (on-body) calibration and cross-talk measurements; and iii) to compare the exposure levels measured for one site in each of several selected microenvironments in the two countries. A human subject took part in an on-body calibration of the exposimeter in an anechoic chamber. The same subject collected data on personal exposures across 38 microenvironments (19 in each country) situated in urban, suburban and rural regions. Median personal RF-EMF exposures were estimated: i) of all microenvironments, and ii) across each microenvironment, in two countries. The exposures were then compared across similar microenvironments in two countries (17 in each country). The three highest median total exposure levels were: city center (4.33V/m), residential outdoor (urban) (0.75V/m), and a park (0.75V/m) [Australia]; and a tram station (1.95V/m), city center (0.95V/m), and a park (0.90V/m) [Belgium]. The exposures across nine microenvironments in Melbourne, Australia were lower than the exposures across corresponding microenvironments in Ghent, Belgium (p<0.05). The personal exposures across urban microenvironments were higher than those for rural or suburban microenvironments. Similarly, the exposure levels across outdoor microenvironments were higher than those for indoor microenvironments.


Asunto(s)
Campos Electromagnéticos , Monitoreo del Ambiente/instrumentación , Ondas de Radio , Australia , Bélgica , Humanos
17.
Bioelectromagnetics ; 37(3): 195-199, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26969843

RESUMEN

For the first time, a method to assess radiofrequency (RF) electromagnetic field (EMF) exposure of the general public in real environments with a true free-space antenna system is presented. Using lightweight electronics and multiple antennas placed on a drone, it is possible to perform exposure measurements. This technique will enable researchers to measure three-dimensional RF-EMF exposure patterns accurately in the future and at locations currently difficult to access. A measurement procedure and appropriate measurement settings have been developed. As an application, outdoor measurements are performed as a function of height up to 60 m for Global System for Mobile Communications (GSM) 900 MHz base station exposure. Bioelectromagnetics. 37:195-199, 2016. © 2016 Wiley Periodicals, Inc.

18.
Bioelectromagnetics ; 37(5): 298-309, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27121268

RESUMEN

For the first time, response of personal exposimeters (PEMs) is studied under diffuse field exposure in indoor environments. To this aim, both numerical simulations, using finite-difference time-domain method, and calibration measurements were performed in the range of 880-5875 MHz covering 10 frequency bands in Belgium. Two PEMs were mounted on the body of a human male subject and calibrated on-body in an anechoic chamber (non-diffuse) and a reverberation chamber (RC) (diffuse fields). This was motivated by the fact that electromagnetic waves in indoor environments have both specular and diffuse components. Both calibrations show that PEMs underestimate actual incident electromagnetic fields. This can be compensated by using an on-body response. Moreover, it is shown that these responses are different in anechoic chamber and RC. Therefore, it is advised to use an on-body calibration in an RC in future indoor PEM measurements where diffuse fields are present. Using the response averaged over two PEMs reduced measurement uncertainty compared to single PEMs. Following the calibration, measurements in a realistic indoor environment were done for wireless fidelity (WiFi-5G) band. Measured power density values are maximally 8.9 mW/m(2) and 165.8 µW/m(2) on average. These satisfy reference levels issued by the International Commission on Non-Ionizing Radiation Protection in 1998. Power density values obtained by applying on-body calibration in RC are higher than values obtained from no body calibration (only PEMs) and on-body calibration in anechoic room, by factors of 7.55 and 2.21, respectively. Bioelectromagnetics. 37:298-309, 2016. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Ambiente , Monitoreo de Radiación/métodos , Ondas de Radio , Calibración , Difusión , Humanos , Masculino , Modelos Teóricos , Monitoreo de Radiación/instrumentación
19.
Sensors (Basel) ; 16(2): 180, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26840320

RESUMEN

This paper describes, for the first time, the procedure for the full design, calibration, uncertainty analysis, and practical application of a personal, distributed exposimeter (PDE) for the detection of personal exposure in the Global System for Mobile Communications (GSM) downlink (DL) band around 900 MHz (GSM 900 DL). The PDE is a sensor that consists of several body-worn antennas. The on-body location of these antennas is investigated using numerical simulations and calibration measurements in an anechoic chamber. The calibration measurements and the simulations result in a design (or on-body setup) of the PDE. This is used for validation measurements and indoor radio frequency (RF) exposure measurements in Ghent, Belgium. The main achievements of this paper are: first, the demonstration, using both measurements and simulations, that a PDE consisting of multiple on-body textile antennas will have a lower measurement uncertainty for personal RF exposure than existing on-body sensors; second, a validation of the PDE, which proves that the device correctly estimates the incident power densities; and third, a demonstration of the usability of the PDE for real exposure assessment measurements. To this aim, the validated PDE is used for indoor measurements in a residential building in Ghent, Belgium, which yield an average incident power density of 0.018 mW/m².

20.
Bioelectromagnetics ; 35(4): 296-308, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24523232

RESUMEN

In this paper, different methods for practical numerical radio frequency exposure compliance assessments of radio base station products were investigated. Both multi-band base station antennas and antennas designed for multiple input multiple output (MIMO) transmission schemes were considered. For the multi-band case, various standardized assessment methods were evaluated in terms of resulting compliance distance with respect to the reference levels and basic restrictions of the International Commission on Non-Ionizing Radiation Protection. Both single frequency and multiple frequency (cumulative) compliance distances were determined using numerical simulations for a mobile communication base station antenna transmitting in four frequency bands between 800 and 2600 MHz. The assessments were conducted in terms of root-mean-squared electromagnetic fields, whole-body averaged specific absorption rate (SAR) and peak 10 g averaged SAR. In general, assessments based on peak field strengths were found to be less computationally intensive, but lead to larger compliance distances than spatial averaging of electromagnetic fields used in combination with localized SAR assessments. For adult exposure, the results indicated that even shorter compliance distances were obtained by using assessments based on localized and whole-body SAR. Numerical simulations, using base station products employing MIMO transmission schemes, were performed as well and were in agreement with reference measurements. The applicability of various field combination methods for correlated exposure was investigated, and best estimate methods were proposed. Our results showed that field combining methods generally considered as conservative could be used to efficiently assess compliance boundary dimensions of single- and dual-polarized multicolumn base station antennas with only minor increases in compliance distances.


Asunto(s)
Campos Electromagnéticos/efectos adversos , Exposición a Riesgos Ambientales/análisis , Adulto , Humanos , Exposición Profesional , Monitoreo de Radiación/métodos , Ondas de Radio/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA