Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 200
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Heart Lung Circ ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38971645

RESUMEN

BACKGROUND: Single-lead electrocardiogram (ECG) devices may allow detection and diagnosis of cardiac rhythms. However, data on their accuracy for detecting cardiac arrhythmias beyond atrial fibrillation are limited. We aimed to determine the accuracy of the AliveCor KardiaMobile (AC) (AliveCor Inc, Mountain View, CA, USA) for the diagnosis of arrhythmias against gold standard cardiac electrophysiology study (EPS). METHOD: Patients undergoing clinically indicated EPS underwent simultaneous rhythm recording with an AC, standard 12-lead ECG, and EP catheters for intracardiac electrograms. Rhythms recorded during EPS were classified based on electrogram, 12-lead ECG, and clinical findings. Blinded reviewers provided differential diagnoses for the single-lead AC tracings; a separate reviewer compared diagnoses made between the AC tracings and EPS findings. RESULTS: In 49 patients, 843 cardiac rhythms were captured during 502 AC recordings. Analysis of tracings containing sinus rhythm (n=273) returned an overall accuracy of 92%, with sensitivity and specificity values of 93% and 92%, respectively. Accuracy for tracings per rhythm was atrial fibrillation 91% (n=51); supraventricular tachycardia accuracy was 89% (n=191), ventricular tachycardia 91% (n=198), ventricular fibrillation 98% (n=11), and asystole 100% (n=5). Accuracy for supraventricular ectopy was 93% (n=28) and for premature ventricular complexes was 91% (n=86). Overall accuracy was 94% for solitary rhythms and 93% in tracings from patients with baseline bundle branch block. CONCLUSIONS: When compared against the gold standard EPS diagnosis, the interpretation of arrhythmias recorded by an AliveCor single-lead ECG device had reasonable diagnostic accuracy.

2.
Heart Lung Circ ; 33(6): 828-881, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38702234

RESUMEN

Catheter ablation for atrial fibrillation (AF) has increased exponentially in many developed countries, including Australia and New Zealand. This Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation from the Cardiac Society of Australia and New Zealand (CSANZ) recognises healthcare factors, expertise and expenditure relevant to the Australian and New Zealand healthcare environments including considerations of potential implications for First Nations Peoples. The statement is cognisant of international advice but tailored to local conditions and populations, and is intended to be used by electrophysiologists, cardiologists and general physicians across all disciplines caring for patients with AF. They are also intended to provide guidance to healthcare facilities seeking to establish or maintain catheter ablation for AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Sociedades Médicas , Fibrilación Atrial/cirugía , Humanos , Ablación por Catéter/métodos , Ablación por Catéter/normas , Nueva Zelanda , Australia , Cardiología/normas , Guías de Práctica Clínica como Asunto
3.
J Adv Nurs ; 79(9): 3622-3631, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37209266

RESUMEN

AIM: The aim of the study was to investigate why registered nurses seek forensic mental health employment and explore their initial impressions of this setting. DESIGN: Explanatory sequential mixed methods. METHODS: Registered nurses employed in a forensic mental health hospital completed an online survey about their reasons for seeking work in forensic mental health and their transition into the setting. To fully explore findings, semi-structured interviews were conducted with a sub-group of survey respondents. Descriptive statistics were used to analyse survey data, and thematic analysis was used to analyse the interviews. RESULTS: Sixty-nine respondents completed the survey, and 11 interviews were conducted. Prior interest in forensic mental health and encouragement from hospital staff were considered important influences in seeking forensic mental health employment. New knowledge, changes in clinical responsibility, exposure to patients' background offences and security processes overwhelmed some participants initially. However, participants reported that the initial challenges of their transition revealed opportunities to develop genuine connections with patients. CONCLUSION: This study provides a new understanding of the reasons why nurses seek employment in forensic mental health and the challenges and opportunities experienced when first working in this setting. Such professional and personal elements need to be considered by organizations to strengthen recruitment strategies and support future nurses' transition into forensic mental health settings. IMPACT: This study provides new knowledge about recruiting and supporting nurses' transition into forensic mental health employment. As such, it informs policymakers, clinical services and managers about strategies needed to attract and retain this workforce. PATIENT OR PUBLIC CONTRIBUTION: No public or patient involvement.


Asunto(s)
Salud Mental , Enfermeras y Enfermeros , Humanos , Atención a la Salud , Recursos Humanos , Empleo/psicología
4.
Heart Lung Circ ; 32(2): 184-196, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36599791

RESUMEN

IMPORTANCE: Randomised trials have shown that catheter ablation (CA) is superior to medical therapy for ventricular tachycardia (VT) largely in patients with ischaemic heart disease. Whether this translates to patients with all forms and stages of structural heart disease (SHD-e.g., non-ischaemic heart disease) is unclear. This trial will help clarify whether catheter ablation offers superior outcomes compared to medical therapy for VT in all patients with SHD. OBJECTIVE: To determine in patients with SHD and spontaneous or inducible VT, if catheter ablation is more efficacious than medical therapy in control of VT during follow-up. DESIGN: Randomised controlled trial including 162 patients, with an allocation ratio of 1:1, stratified by left ventricular ejection fraction (LVEF) and geographical region of site, with a median follow-up of 18-months and a minimum follow-up of 1 year. SETTING: Multicentre study performed in centres across Australia. PARTICIPANTS: Structural heart disease patients with sustained VT or inducible VT (n=162). INTERVENTION: Early treatment, within 30 days of randomisation, with catheter ablation (intervention) or initial treatment with antiarrhythmic drugs only (control). MAIN OUTCOMES, MEASURES, AND RESULTS: Primary endpoint will be a composite of recurrent VT, VT storm (≥3 VT episodes in 24 hrs or incessant VT), or death. Secondary outcomes will include each of the individual primary endpoints, VT burden (number of VT episodes in the 6 months preceding intervention compared to the 6 months after intervention), cardiovascular hospitalisation, mortality (including all-cause mortality, cardiac death, and non-cardiac death) and LVEF (assessed by transthoracic echocardiography from baseline to 6-, 12-, 24- and 36-months post intervention). CONCLUSIONS AND RELEVANCE: The Catheter Ablation versus Anti-arrhythmic Drugs for Ventricular Tachycardia (CAAD-VT) trial will help determine whether catheter ablation is superior to antiarrhythmic drug therapy alone, in patients with SHD-related VT. TRIAL REGISTRY: Australian New Zealand Clinical Trials Registry (ANZCTR) TRIAL REGISTRATION ID: ACTRN12620000045910 TRIAL REGISTRATION URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=377617&isReview=true.


Asunto(s)
Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Antiarrítmicos/uso terapéutico , Volumen Sistólico , Estudios Prospectivos , Resultado del Tratamiento , Función Ventricular Izquierda , Australia/epidemiología , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Isquemia Miocárdica/cirugía , Ablación por Catéter/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
5.
Sex Abuse ; 35(6): 667-686, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36380713

RESUMEN

Treatment programs for people with histories of sexual violence form a critical part of criminal justice service rehabilitation. Completion of these programs is often a precondition of release. Meta-analytic reviews suggest moderate benefit is associated with treatment completion, although effect sizes vary. This study examined whether commencement of open versus closed group programs was associated with treatment completion and recidivism. Participants were 426 adult men who commenced treatment between April 1, 2014, and December 31, 2017. Participants were followed-up until June 30, 2018. Programs varied by type (open versus closed), location (in-custody versus in-community) and intensity (moderate versus high). No significant differences were observed between open and closed programs for treatment completion but men who were treated in-custody were more likely to complete treatment when compared to those men who commenced treatment in the community. No significant differences were observed between open and closed programs for sexual or for any recidivism.


Asunto(s)
Criminales , Reincidencia , Delitos Sexuales , Masculino , Adulto , Humanos , Conducta Sexual , Derecho Penal
6.
Heart Lung Circ ; 31(8): 1064-1074, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35643798

RESUMEN

BACKGROUND: There are differences in substrate and ablation approaches for ventricular tachycardia (VT) in ischaemic (ICM) and non-ischaemic cardiomyopathy (NICM). OBJECTIVE: To perform a systematic review and meta-analysis comparing clinical and procedural characteristics/outcomes of VT ablation in ICM versus NICM. METHODS: Electronic databases were searched for comparative studies reporting outcomes of VT ablation in patients with ICM and NICM. Primary outcomes were acute procedural success, VT recurrence and long-term mortality. Meta-analyses were performed using random-effects modelling. RESULTS: Thirty-one (31) studies (7,473 patients; 4,418 ICM and 3,055 NICM) were included. Patients with ICM were significantly older (67.0 vs 55.3 yrs), more commonly male (89% vs 79%), had lower left ventricular ejection fraction (29% vs 38%) were less likely to undergo epicardial access (11% vs 36%) and were more likely to require haemodynamic support during ablation (relative risk [RR] 1.30; 95% CI 1.01-1.69). Acute procedural success (i.e. non-inducibility of VT) was higher in the ICM cohort (RR 1.10, 95% CI 1.05-1.15). Recurrence of VT at follow-up was significantly lower in the ICM cohort (RR 0.77; 95% CI 0.70-0.84). Peri-procedural mortality, incidence of procedural complications and long-term mortality were not significantly different between the cohorts. CONCLUSIONS: NICM and ICM patients undergoing VT ablation are fundamentally different in their clinical characteristics, ablation approaches, acute procedural outcomes and likelihood of VA recurrence. VT ablation in NICM has a lower likelihood of procedural success with increased risk of VA recurrence, consistent with known challenging arrhythmia substrate.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Cardiomiopatías/complicaciones , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Humanos , Masculino , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Recurrencia , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Heart Lung Circ ; 31(11): 1432-1449, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36109292

RESUMEN

Cardiac arrhythmias are associated with significant morbidity, mortality and economic burden on the health care system. Detection and surveillance of cardiac arrhythmias using medical grade non-invasive methods (electrocardiogram, Holter monitoring) is the accepted standard of care. Whilst their accuracy is excellent, significant limitations remain in terms of accessibility, ease of use, cost, and a suboptimal diagnostic yield (up to ∼50%) which is critically dependent on the duration of monitoring. Contemporary wearable and handheld devices that utilise photoplethysmography and the electrocardiogram present a novel opportunity for remote screening and diagnosis of arrhythmias. They have significant advantages in terms of accessibility and availability with the potential of enhancing the diagnostic yield of episodic arrhythmias. However, there is limited data on the accuracy and diagnostic utility of these devices and their role in therapeutic decision making in clinical practice remains unclear. Evidence is mounting that they may be useful in screening for atrial fibrillation, and anecdotally, for the diagnosis of other brady and tachyarrhythmias. Recently, there has been an explosion of patient uptake of such devices for self-monitoring of arrhythmias. Frequently, the clinician is presented such information for review and comment, which may influence clinical decisions about treatment. Further studies are needed before incorporation of such technologies in routine clinical practice, given the lack of systematic data on their accuracy and utility. Moreover, challenges with regulation of quality standards and privacy remain. This state-of-the-art review summarises the role of novel ambulatory, commercially available, heart rhythm monitors in the diagnosis and management of cardiac arrhythmias and their expanding role in the diagnostic and therapeutic paradigm in cardiology.


Asunto(s)
Fibrilación Atrial , Dispositivos Electrónicos Vestibles , Humanos , Electrocardiografía Ambulatoria/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Electrocardiografía
8.
J Appl Res Intellect Disabil ; 35(3): 789-799, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35158411

RESUMEN

BACKGROUND: While there is growing international evidence pointing to the increased risks of crime perpetration and victimisation for some people with an intellectual disability, the overlap between offending and victimisation (the victim-offender overlap) remains unclear. METHOD: This study utilised a data linkage methodology of 2600 people with an intellectual disability, exploring their contacts with public mental health services and the police in Victoria, Australia. RESULTS: Victim-offenders accounted for a small proportion of the sample (n = 148, 5.7%). The victim-offender overlap was evident for both violent and nonviolent nonsexual crimes, particularly for theft, burglary, and threat-related crimes. Key differences were also noted between males and females. CONCLUSIONS: People with an intellectual disability who are both victim and offenders comprise a small but particularly complex justice-involved population. Future research should explore the victim offender overlap for males and females separately, as well as any additional risks and vulnerabilities associated with specific mental health diagnoses.


Asunto(s)
Víctimas de Crimen , Criminales , Discapacidad Intelectual , Crimen , Femenino , Humanos , Discapacidad Intelectual/epidemiología , Masculino , Victoria/epidemiología
9.
Heart Lung Circ ; 30(4): 555-566, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33153905

RESUMEN

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) can provide circulatory support in high-risk patients undergoing drug refractory ventricular tachycardia (VT) ablation procedures. We report experience using VA-ECMO in a pre-emptive approach for high-risk patients with VT storm and previously ineffective ablation procedures. METHODS AND RESULTS: Four (4) patients with drug refractory ventricular tachycardia (mean age 61±3 years; left ventricular ejection fraction 21±5%) presenting for VT ablation had pre-emptive VA-ECMO. All patients during current admission had VT storm. Pre-ablation, 22 total monomorphic VTs (cycle length 402±69 ms) were induced or spontaneously observed (median of 4, IQR25-75% 1-6). At the end of the procedure, 86% of all inducible VTs were rendered non-inducible. Median hospitalisation following VA-ECMO supported ablation was 5 days (IQR25-75% 3-12). During follow-up (median 138 days [IQR25-75% 57-277]), VT recurred in one patient as an isolated episode reverted by anti-tachycardia pacing. There was a 99% reduction in VT burden post ablation. One (1) patient died of cardiogenic shock within 24 hours whilst still on VA-ECMO, all other patients were successfully weaned off support and discharged. Two (2) patients underwent cardiac transplantation at 199 and 512 days post ablation following implantation of ventricular assist devices for worsening heart failure. CONCLUSIONS: The pre-emptive use of VA-ECMO for high-risk patients undergoing catheter ablation for VT storm was found to be effective in maintaining haemodynamic status, and allowing successful mapping and catheter ablation for VT.


Asunto(s)
Ablación por Catéter , Oxigenación por Membrana Extracorpórea , Taquicardia Ventricular , Australia/epidemiología , Humanos , Persona de Mediana Edad , Volumen Sistólico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda
10.
Aust N Z J Psychiatry ; 54(3): 288-297, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31813230

RESUMEN

OBJECTIVE: Previous randomised, double-blind, placebo-controlled studies have shown that Kava (a South Pacific medicinal plant) reduced anxiety during short-term administration. The objective of this randomised, double-blind, placebo-controlled study was to perform a larger, longer-term trial assessing the efficacy and safety of Kava in the treatment of generalised anxiety disorder and to determine whether gamma-aminobutyric acid transporter (SLC6A1) single-nucleotide polymorphisms were moderators of response. METHODS: The trial was a phase III, multi-site, two-arm, 16-week, randomised, double-blind, placebo-controlled study investigating an aqueous extract of dried Kava root administered twice per day in tablet form (standardised to 120 mg of kavalactones twice/day) in 171 currently non-medicated anxious participants with diagnosed generalised anxiety disorder. The trial took place in Australia. RESULTS: An analysis of 171 participants revealed a non-significant difference in anxiety reduction between the Kava and placebo groups (a relative reduction favouring placebo of 1.37 points; p = 0.25). At the conclusion of the controlled phase, 17.4% of the Kava group were classified as remitted (Hamilton Anxiety Rating Scale score < 7) compared to 23.8% of the placebo group (p = 0.46). No SLC6A1 polymorphisms were associated with treatment response, while carriers of the rs2601126 T allele preferentially respond to placebo (p = 0.006). Kava was well tolerated aside from poorer memory (Kava = 36 vs placebo = 23; p = 0.044) and tremor/shakiness (Kava = 36 vs placebo = 23; p = 0.024) occurring more frequently in the Kava group. Liver function test abnormalities were significantly more frequent in the Kava group, although no participant met criteria for herb-induced hepatic injury. CONCLUSION: While research has generally supported Kava in non-clinical populations (potentially for more 'situational' anxiety as a short-term anxiolytic), this particular extract was not effective for diagnosed generalised anxiety disorder.


Asunto(s)
Ansiolíticos/uso terapéutico , Trastornos de Ansiedad/tratamiento farmacológico , Kava/química , Extractos Vegetales/uso terapéutico , Adulto , Ansiolíticos/efectos adversos , Trastornos de Ansiedad/genética , Australia , Método Doble Ciego , Femenino , Proteínas Transportadoras de GABA en la Membrana Plasmática/genética , Humanos , Masculino , Persona de Mediana Edad , Fitoterapia , Extractos Vegetales/efectos adversos , Raíces de Plantas/química , Polimorfismo de Nucleótido Simple , Escalas de Valoración Psiquiátrica , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
Heart Lung Circ ; 29(6): e57-e68, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32451232

RESUMEN

The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Pandemias , Neumonía Viral , Australia/epidemiología , COVID-19 , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/fisiopatología , Infecciones por Coronavirus/terapia , Humanos , Neumonía Viral/epidemiología , Neumonía Viral/fisiopatología , Neumonía Viral/terapia , SARS-CoV-2
13.
Heart Lung Circ ; 28(5): 707-718, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30509786

RESUMEN

BACKGROUND: Catheter ablation (CA) is highly efficacious for symptomatic atrial fibrillation (AF) but data predominantly comes from patients with preserved ventricular function. We performed an updated systematic review and meta-analysis of randomised controlled trials (RCT) comparing CA versus medical therapy for AF associated with heart failure (HF). METHODS: Medline, EMBASE, and Cochrane Central Register of Controlled Trials (CENTRAL) were searched for RCTs reporting clinical outcomes of CA versus medical therapy for AF in HF patients with ≥6 months' follow-up (atrioventricular-node ablation/device therapy studies excluded). Primary endpoint was change in left ventricular ejection fraction (LVEF). Secondary endpoints were 6-minute walk test (6MWT) distance, quality of life (QoL; measured by the Minnesota Living with Heart Failure Questionnaire [MLHFQ]), peri-procedural mortality, major peri-procedural complications and mid-term (≥1-year) survival. RESULTS: Six RCTs (n=772 patients; mean age 62±11years, LVEF 30±9%) were included. Catheter ablation, compared to medical therapy was associated with: greater improvement in LVEF (mean difference [MD] 5.67%; 95% Confidence Interval [CI], 3-8; I2=87%; p<0.001), greater increase in 6MWT distance (MD 25.1 metres; 95% CI, 0.6-50; I2=94%; p=0.04), improved QoL with greater reduction in MLHFQ scores (MD 9.03; 95% CI, 2.5-15.6; I2=47%; p=0.007), and significantly reduced mid-term mortality (relative risk 0.52; 95% CI, 0.4-0.8; I2=0%; p=0.001). Freedom from AF after ≥1 procedure was 71%; major complications occurred in 8% of patients. CONCLUSION: Catheter ablation is superior to medical therapy for AF in patients with heart failure resulting in greater improvement in LVEF, quality of life and functional status, with a survival benefit.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Nodo Atrioventricular/fisiopatología , Ablación por Catéter/métodos , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda/fisiología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
Australas Psychiatry ; 27(1): 32-35, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30293446

RESUMEN

OBJECTIVES:: To evaluate the therapeutic security characteristics of the secure forensic mental health inpatient units in New South Wales, Australia. METHODS:: This study evaluated all eight secure inpatient units in New South Wales using a validated tool, the Security Needs Assessment Profile. RESULTS:: A pattern of decreasing therapeutic security across the secure units was found, consistent with their intended security levels, from high security through to open security. However, important inconsistencies across and between levels of security were highlighted. CONCLUSIONS:: This study clarifies the therapeutic security structure of the New South Wales forensic mental health service, which is an essential first step in service development and reform.


Asunto(s)
Psiquiatría Forense/estadística & datos numéricos , Unidades Hospitalarias/estadística & datos numéricos , Hospitales Psiquiátricos/estadística & datos numéricos , Seguridad del Paciente/estadística & datos numéricos , Medidas de Seguridad/estadística & datos numéricos , Humanos , Nueva Gales del Sur
15.
J Appl Res Intellect Disabil ; 32(5): 1088-1095, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30990251

RESUMEN

BACKGROUND: Accumulating evidence internationally points to an increased risk of crime perpetration and victimization among people with an intellectual disability (ID). This study aimed to examine the impact that comorbid mental illness had on the association between intellectual disability, crime perpetration and criminal victimization. METHOD: A case linkage methodology involving 2,220 individuals with an intellectual disability from an Australian State. RESULTS: One in four (27%) had contacts with public mental health services; 8.2% had a comorbid mental illness. This "dual disability" group was between 2.97 and 3.22 times more likely than those with intellectual disability alone to have a history of criminal charges, and between 2.76 and 2.97 times more likely to have been a victim of crime. CONCLUSIONS: The extent of criminality and victimization found among people with dual disability indicates a potentially multiply stigmatized group for whom the need for a coordinated cross-agency service response remains paramount.


Asunto(s)
Víctimas de Crimen/estadística & datos numéricos , Crimen/estadística & datos numéricos , Personas con Discapacidad/estadística & datos numéricos , Discapacidad Intelectual/epidemiología , Trastornos Mentales/epidemiología , Adulto , Comorbilidad , Femenino , Humanos , Masculino , Victoria/epidemiología
16.
Psychiatr Psychol Law ; 26(2): 235-251, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31984075

RESUMEN

Police encounters with people experiencing mental illness are both common and problematic. While there is an international body of literature on police officers' perceptions of mental-health-related incidents, few studies have sought to understand these encounters from the perspectives of people experiencing mental illness. This pilot study recruited 26 people through a state-wide Consumer Advisory Group who completed an online survey regarding their encounters with police. Results indicated that when people perceived procedurally just treatment from police they were more likely to co-operate with them and to evaluate the encounter positively. The nature of police involvement and levels of internalised stigma moderated the association between perceived procedural justice and their evaluation. Prior contacts were also important in shaping participants' overall attitudes towards police. Findings highlight the importance of officers treating people experiencing mental illness fairly and respectfully to facilitate peaceful encounters and help foster more positive perceptions of the police.

17.
J Cardiovasc Electrophysiol ; 29(2): 345-352, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29178497

RESUMEN

Catheter ablation has become standard of care in patients with symptomatic atrial fibrillation (AF). Although there have been significant advances in our understanding and technology, a substantial proportion of patients have ongoing AF requiring repeat procedures. Pulmonary vein isolation (PVI) is the cornerstone of AF ablation; however, it is less effective in patients with persistent as opposed to paroxysmal atrial fibrillation. Left atrial posterior wall isolation (PWI) is commonly performed as an adjunct to PVI in patients with persistent AF with nonrandomized studies showing improved outcomes. Anatomical considerations and detailed outline of the various approaches and techniques to performing PWI are detailed, and advantages and pitfalls to assist the clinical electrophysiologist successfully and safely complete PWI are described.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Radiografía Intervencional , Resultado del Tratamiento
18.
Europace ; 20(suppl_2): ii11-ii21, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29722861

RESUMEN

Aims: Remote magnetic navigation (RMN) is a safe and effective means of performing ventricular tachycardia (VT) ablation. It may have advantages over manual catheter ablation due to ease of manoeuvrability and catheter stability. We sought to compare the safety and efficacy of RMN vs. manual VT ablation. Methods and results: Retrospective study of procedural outcomes of 139 consecutive VT ablation procedures (69 RMN, 70 manual ablation) in 113 patients between 2009 and 2015 was performed. Remote magnetic navigation was associated with overall higher acute procedural success (80% vs. 60%, P = 0.01), with a trend to fewer major complications (3% vs. 9% P = 0.09). Seventy-nine patients were followed up for a median of 17.0 [interquartile range (IQR) 3.0-41.0] months for the RMN group and 15.5 (IQR 6.5-30.0) months for manual ablation group. In the ischaemic cardiomyopathy subgroup, RMN was associated with longer survival from the composite endpoint of VT recurrence leading to defibrillator shock, re-hospitalization or repeat catheter ablation and all-cause mortality; single-procedure adjusted hazard ratio (HR) 0.240 (95% CI 0.070-0.821) P = 0.023, multi-procedure HR 0.170 (95% CI 0.046-0.632) P = 0.002. In patients with implanted defibrillators, multi-procedure VT-free survival was superior with RMN, HR 0.199 (95% CI 0.060-0.657) P = 0.003. Conclusion: Remote magnetic navigation may improve clinical outcomes after catheter ablation of VT in patients with ischaemic cardiomyopathy. Further prospective clinical studies are required to confirm these findings.


Asunto(s)
Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Magnetismo/métodos , Tecnología de Sensores Remotos/métodos , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Ablación por Catéter/mortalidad , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Magnetismo/instrumentación , Imanes , Masculino , Persona de Mediana Edad , Recurrencia , Tecnología de Sensores Remotos/instrumentación , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/mortalidad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
19.
BMC Psychiatry ; 18(1): 35, 2018 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-29415683

RESUMEN

BACKGROUND: Routine outcome measures are increasingly being mandated across mental health services in Australia and overseas. This requirement includes forensic mental health services, but their utility in such specialist services and the inter-relationships between the measures remain unclear. This study sought to characterise the risks, needs and stages of recovery of an entire cohort of forensic patients in one jurisdiction in Australia. METHODS: Local expert groups, comprising of members of the forensic patient treating teams, were formed to gather information about the status and needs of all forensic patients in the State of New South Wales, Australia. The expert groups provided demographic information and completed three assessment tools concerning the risks, needs and stages of recovery of each forensic patient. RESULTS: The cohort of 327 forensic patients in NSW appears to be typical of forensic mental health service populations internationally when considering factors such as gender, diagnosis, and index offence. A number of important differences across the three structured tools for forensic patients in different levels of secure service provision are presented. The DUNDRUM Quartet demonstrated interesting findings, particularly in terms of the therapeutic security needs, the treatment completion, and the stages of recovery for the forensic patients in the community. The CANFOR highlighted the level of needs across the forensic patient population, whilst the HCR-20 data showed there was no significant difference in the mean clinical and risk management scores between male forensic patients across levels of security. CONCLUSIONS: To the authors' knowledge this is the first study of its kind in New South Wales, Australia. We have demonstrated the utility of using a suite of measures to evaluate the risks, needs, and stages of recovery for an entire cohort of forensic patients. The data set helps inform service planning and development, together with providing various avenues for future research.


Asunto(s)
Criminales/psicología , Psiquiatría Forense/tendencias , Necesidades y Demandas de Servicios de Salud/tendencias , Trastornos Mentales/epidemiología , Trastornos Mentales/psicología , Recuperación de la Función , Adulto , Estudios de Cohortes , Femenino , Psiquiatría Forense/métodos , Humanos , Masculino , Trastornos Mentales/terapia , Servicios de Salud Mental/tendencias , Persona de Mediana Edad , Nueva Gales del Sur/epidemiología , Evaluación de Resultado en la Atención de Salud , Factores de Riesgo
20.
Heart Lung Circ ; 27(1): 114-121, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28457700

RESUMEN

BACKGROUND: Patch clamping studies using non-cardiomyocytes revealed that the human connexin40 mutations P88S, G38D, and A96S are associated with reduced gap junction conductances compared to wild type connexin40 (wtCx40). Their effects within myocytes however are unclear. We aimed to characterise P88S, G38D, and A96S after expression in rat hearts and primary cardiomyocyte cultures. METHODS: Adult Sprague-Dawley rat atria were transduced with a lentivector containing a transgene encoding wtCx40, P88S, G38D, A96S, or eGFP (n=6 per transgene). Electrophysiology studies (EPS) were performed just prior to and 7 days after surgery. Left atria were assessed for connexin expression, mRNA levels, inflammation and fibrosis. Primary cardiomyocyte cultures were also transduced with the abovementioned vectors (n=6 per transgene) and monolayer conduction velocities (CV) and protein expression were assessed at 96hours. RESULTS: At day 7 EPS, P wave and induced atrial fibrillation (AF) durations were significantly longer in the mutant groups when compared to wtCx40 controls (p<0.05). There were no significant differences in inflammation, fibrosis, or heart to body weight ratios. Monolayer CV's were reduced in the A96S group compared to the wtCx40 group. While similar to wtCx40 controls, P88S velocities were reduced compared to eGFP controls. G38D monolayers possessed spontaneous fibrillatory activity and could not be paced. Immunofluorescence revealed that P88S and G38D reduced native connexin43 myocyte coupling while A96S appeared to co-localise with connexin43 in gap junctions. Connexin43 mRNA levels were similar between groups. CONCLUSIONS: The A96S, G38D, and P88S Cx40 mutations slow conduction and increased the propensity for inducible AF.


Asunto(s)
Fibrilación Atrial/genética , Conexinas/genética , ADN/genética , Mutación , Miocitos Cardíacos/patología , Animales , Fibrilación Atrial/metabolismo , Fibrilación Atrial/patología , Western Blotting , Conexinas/metabolismo , Análisis Mutacional de ADN , Modelos Animales de Enfermedad , Uniones Comunicantes , Humanos , Miocitos Cardíacos/metabolismo , Ratas , Ratas Sprague-Dawley , Proteína alfa-5 de Unión Comunicante
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA