Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
AJNR Am J Neuroradiol ; 40(4): 694-698, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30846433

RESUMEN

BACKGROUND AND PURPOSE: Flow diversion is an established method to treat complex intracranial aneurysms. The natural history of flow-diversion treatment failure resulting in aneurysm remnants is not well-defined. We aimed to delineate the clinical and angiographic features of this entity. MATERIALS AND METHODS: Review of a prospectively maintained Pipeline Embolization Device data base from inception to October 2017 was performed for aneurysms that demonstrated residual filling on follow-up imaging. Procedural and follow-up clinical details were recorded. Independent, blinded, angiographic assessment of occlusion was performed on the basis of the O'Kelly-Marotta scale. Aggregated outcomes were analyzed using the Fisher exact and Mann-Whitney U tests for categoric and continuous variables, respectively (statistical significance, α = .05). RESULTS: During the study period, 283 sequential patients were treated; 87% (246/283) were women. The median patient age was 55 years (interquartile range, 47-65 years). Six-month follow-up imaging was available in 83.7% (237/283) of patients, which showed 62.4% (148/237) complete occlusion (class D, O'Kelly-Marotta grading scale). Adjunctive coiling (P = .06), on-label Pipeline Embolization Device use (P = .04), and multiple device constructs (P = .02) had higher rates of complete occlusion at 6 months. Aneurysm remnants were identified in 25 cases on long-term follow-up imaging (median, 16 months; interquartile range, 12-24 months). No patient with an aneurysm remnant after flow diversion presented with delayed rupture or other clinical sequelae, with a median clinical follow-up of 31 months (interquartile range, 23-33 months). CONCLUSIONS: Aneurysm remnants after flow diversion are infrequent with minimal clinical impact. When appropriate, the presence of overlapping devices and possibly adjunctive coiling may result in higher rates of complete occlusion.


Asunto(s)
Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/patología , Aneurisma Intracraneal/terapia , Adulto , Anciano , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
2.
AJNR Am J Neuroradiol ; 28(7): 1415-7, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17698555

RESUMEN

This report describes a series of patients for whom dural arteriovenous fistulae (DAVFs) of the cavernous sinus were successfully embolized using a percutaneous, transorbital technique to directly cannulate the cavernous sinus. A vascular access needle and catheter are percutaneously advanced along the inferolateral aspect of the orbit to access the cavernous sinus via the superior orbital fissure. Safe and effective embolization is achieved without the need for a surgical cut-down.


Asunto(s)
Seno Cavernoso/anomalías , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Duramadre/irrigación sanguínea , Duramadre/cirugía , Embolización Terapéutica/métodos , Órbita/cirugía , Punciones/métodos , Anciano de 80 o más Años , Duramadre/anomalías , Femenino , Humanos , Masculino , Resultado del Tratamiento
3.
AJNR Am J Neuroradiol ; 28(5): 808-15, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17494648

RESUMEN

BACKGROUND AND PURPOSE: After an initial series of basilar artery stent angioplasty indicated a high technical success rate and minimal morbidity, subsequent reports suggested significant procedural risks. We retrospectively reviewed our experience with basilar artery stent placement to assess complications and clinical outcomes. MATERIALS AND METHODS: Ten consecutive patients with symptomatic intracranial athero-occlusive disease underwent stent placement of the basilar artery at our institution (1999-2003). We collected clinical data by chart review and determined outcomes (modified Rankin Scale [mRS]) by telephone interview. Angiographic data were analyzed by 2 blinded investigators. Clinical and angiographic variables were tested for correlation with outcome and complications using the Pearson correlation test. RESULTS: Of 10 patients (mean follow-up time, 31 months), 4 patients suffered 6 ischemic complications that were immediate in 1, early delayed (<2 weeks) in 4, and late delayed (>2 weeks) in 1. Complications included basilar artery rupture in 1 patient, access site complications in 1 patient, and other non-neurologic complications in 5. Symptomatic restenosis occurred in 1 patient. Outcomes (mRS) were excellent (0-2) in 5 patients, good (3) in 4, and poor (4-6) in 1 patient, who died. Ischemic complications were associated with lesion lumen 45 degrees (P<.05). Less favorable clinical outcomes were associated with few ischemic complications and the presence of fewer than 2 patent vertebral arteries (P<.05). CONCLUSIONS: Despite a significant incidence of ischemic and nonischemic complications after basilar artery stent placement, most patients in this small series achieved freedom from vertebrobasilar ischemia and good to excellent clinical outcomes at late midterm follow-up (12-46 months). Ischemic complications usually had an early delayed presentation and procedural risks correlated with lesion characteristics.


Asunto(s)
Angioplastia/métodos , Complicaciones Posoperatorias/epidemiología , Stents , Insuficiencia Vertebrobasilar/epidemiología , Insuficiencia Vertebrobasilar/cirugía , Anciano , Anciano de 80 o más Años , Aneurisma Roto/epidemiología , Aneurisma Roto/cirugía , Isquemia Encefálica/epidemiología , Isquemia Encefálica/prevención & control , Femenino , Fibrinolíticos/uso terapéutico , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Morbilidad , Complicaciones Posoperatorias/prevención & control , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
4.
AJNR Am J Neuroradiol ; 36(12): 2354-9, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26381560

RESUMEN

BACKGROUND AND PURPOSE: Current nonhuman primate stroke models are limited by either stroke variability or survivability. A new nonhuman primate stroke model was developed by using endovascular trapping techniques to limit collateral vessels with serial MR imaging and neurologic assessments. MATERIALS AND METHODS: Eight adult rhesus monkeys (female, 7-13 years of age) underwent MR imaging and Spetzler neurologic assessment followed by endovascular stroke induction consisting of superselective endovascular placement of surgical silk sutures into the right MCA by using a trapping technique. Two initial subjects were euthanized immediately following postocclusion MR imaging. The subsequent 6 subjects recovered and underwent follow-up MR imaging and Spetzler neurologic assessments at 48 hours, with 4 being followed to 96 hours. Stroke infarct volumes were measured, and the longitudinal Spetzler clinical neurologic scores were assessed. The brain tissues were harvested and prepared with hematoxylin-eosin staining. RESULTS: Focal permanent cerebral ischemia was induced in the targeted right MCA territory in all subjects. The volumes of the ischemic lesions at 6, 48, and 96 hours were 3.18 ± 1.007 mL (standard error of the mean) (n = 8), 6.70 ± 1.666 mL (standard error of the mean) (n = 6), and 7.23 ± 1.371 mL (standard error of the mean) (n = 4). For the survival animals, the immediate postsurgical Spetzler grading score improved from 60.7 at 24 hours to 68.7 at 48 hours. CONCLUSIONS: We report a trapping modification to an established endovascular suture stroke model that yielded reproducible ischemia and clinically quantifiable neurologic deficits with no strokes in nontarget areas. This technique may be useful in evaluating translational stroke and penumbral imaging research in addition to preclinical testing of neuroprotective therapies.


Asunto(s)
Modelos Animales de Enfermedad , Infarto de la Arteria Cerebral Media/patología , Animales , Procedimientos Endovasculares , Femenino , Macaca mulatta , Imagen por Resonancia Magnética
5.
AJNR Am J Neuroradiol ; 22(9): 1764-7, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11673176

RESUMEN

We describe four cases in which abciximab was used as a thrombolytic rescue agent in the setting of thrombotic events complicating interventional neuroradiologic procedures. After IV administration of abciximab, the thrombus resolved within 30 min in three cases, whereas no thrombolysis occurred in the fourth case despite the addition of intraarterial tissue plasminogen activator. Further evaluation of glycoprotein IIb-IIIa inhibitors in patients with cerebral thromboembolic events is necessary to prove clinical efficacy.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Embolia Intracraneal/tratamiento farmacológico , Trombosis Intracraneal/tratamiento farmacológico , Neurorradiografía/efectos adversos , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Radiografía Intervencional/efectos adversos , Terapia Trombolítica , Abciximab , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Embolia Intracraneal/etiología , Trombosis Intracraneal/etiología
6.
AJNR Am J Neuroradiol ; 21(9): 1750-2, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11039360

RESUMEN

Occlusion of an internal carotid artery stent was identified immediately post placement in a patient who had restenosis after prior angioplasty. An IV dose of abciximab was administered, and serial angiograms were performed. This resulted in partial resolution of the thrombus at 10 minutes and complete resolution at 20 minutes.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Estenosis Carotídea/tratamiento farmacológico , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/uso terapéutico , Stents , Trombosis/tratamiento farmacológico , Abciximab , Enfermedad Aguda , Adulto , Angioplastia de Balón , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/patología , Estenosis Carotídea/diagnóstico , Estenosis Carotídea/diagnóstico por imagen , Humanos , Angiografía por Resonancia Magnética , Masculino , Radiografía , Recurrencia
7.
AJNR Am J Neuroradiol ; 21(7): 1312-4, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10954285

RESUMEN

A three-dimensional Guglielmi detachable coil (3D-GDC) has been developed that is designed specifically to bridge the neck of an aneurysm with coil loops, thereby facilitating retention of additional coils placed within the aneurysm. Nine wide-necked cerebral aneurysms were successfully embolized using the 3D-GDC, provided that the dome-to-neck ratio was 1.5 or greater.


Asunto(s)
Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/terapia , Anciano , Anciano de 80 o más Años , Angiografía Cerebral , Diseño de Equipo , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad
8.
J Clin Neurosci ; 7(3): 244-53, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10833624

RESUMEN

Endovascular therapy for intracranial aneurysms has evolved since Serbinenko pioneered embolisation with latex balloons in the 1970s. The focus of modern endovascular therapy has shifted to the use of Guglielmi Detachable Coils (GDC; Boston Scientific Corporation, Natick, MA, USA) which are retrievable until the operator is satisfied with placement and they are detached. GDC therapy has been shown to be most efficacious in smaller aneurysms with relatively large dome:neck ratios which allow maximal coil packing within the aneurysm lumen. Wide neck aneurysms with dome:neck ratios of less than 2.0 and large aneurysms have a significantly lower incidence of complete treatment, with higher rates of repeat rupture following GDC therapy. The geometry of wide neck aneurysms is less favourable for retention of coils within the aneurysm lumen, resulting in greater risk of parent vessel compromise from coil herniation and difficulty obtaining maximal coil packing. This chapter will summarise GDC therapy for intracranial aneurysms including newer techniques designed to address the problem of wide neck aneurysms.


Asunto(s)
Angioplastia de Balón/métodos , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Aneurisma Intracraneal/terapia , Angioplastia de Balón/efectos adversos , Angiografía Cerebral , Embolización Terapéutica/efectos adversos , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/patología , Selección de Paciente , Stents
9.
AJNR Am J Neuroradiol ; 35(11): 2112-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24994828

RESUMEN

BACKGROUND AND PURPOSE: Endovascular reconstruction and flow diversion by using the Pipeline Embolization Device is an effective treatment for complex cerebral aneurysms. Accurate noninvasive alternatives to DSA for follow-up after Pipeline Embolization Device treatment are desirable. This study evaluated the accuracy of contrast-enhanced time-resolved MRA for this purpose, hypothesizing that contrast-enhanced time-resolved MRA will be comparable with DSA and superior to 3D-TOF MRA. MATERIALS AND METHODS: During a 24-month period, 37 Pipeline Embolization Device-treated intracranial aneurysms in 26 patients underwent initial follow-up by using 3D-TOF MRA, contrast-enhanced time-resolved MRA, and DSA. MRA was performed on a 1.5T unit by using 3D-TOF and time-resolved imaging of contrast kinetics. All patients underwent DSA a median of 0 days (range, 0-68) after MRA. Studies were evaluated for aneurysm occlusion, quality of visualization of the reconstructed artery, and measurable luminal diameter of the Pipeline Embolization Device, with DSA used as the reference standard. RESULTS: The sensitivity, specificity, and positive and negative predictive values of contrast-enhanced time-resolved MRA relative to DSA for posttreatment aneurysm occlusion were 96%, 85%, 92%, and 92%. Contrast-enhanced time-resolved MRA demonstrated superior quality of visualization (P = .0001) and a higher measurable luminal diameter (P = .0001) of the reconstructed artery compared with 3D-TOF MRA but no significant difference compared with DSA. Contrast-enhanced time-resolved MRA underestimated the luminal diameter of the reconstructed artery by 0.965 ± 0.497 mm (27% ± 13%) relative to DSA. CONCLUSIONS: Contrast-enhanced time-resolved MRA is a reliable noninvasive method for monitoring intracranial aneurysms following flow diversion and vessel reconstruction by using the Pipeline Embolization Device.


Asunto(s)
Angiografía Cerebral/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Angiografía de Substracción Digital/métodos , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Resultado del Tratamiento
10.
AJNR Am J Neuroradiol ; 30(9): 1657-64, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19696140

RESUMEN

BACKGROUND AND PURPOSE: Denser coil packing in intracranial aneurysms is believed to result in lower recanalization rates. Hydrogel-coated expandable coils (HydroCoil) improve volumetric packing of aneurysms in animal models and clinical studies, but data from large clinical series are limited. The objective of this retrospective analysis was to analyze immediate and follow-up angiographic results as well as complications in a large consecutive series of patients treated with HydroCoils at a single institution. MATERIALS AND METHODS: Retrospective analysis was performed of periprocedural complications, immediate and follow-up angiograms, and retreatments of the first 200 consecutive intracranial aneurysms treated at Emory University Hospital. RESULTS: One hundred eighty-seven patients with 200 intracranial aneurysms were treated with HydroCoils during a 3-year period. Immediate angiograms showed complete aneurysmal obliteration in 58.4% of small aneurysms and 42.7% of large aneurysms. Periprocedural complications included early rebleeding and thromboembolic events resulting in permanent neurologic morbidity and mortality in 6% of cases. Follow-up angiography during an average of 16.3 months demonstrated recanalization in 17.7% of small aneurysms and 28.6% of large aneurysms, requiring retreatment in 6.3% and 19.0% of cases, respectively. During the same time period, there was delayed angiographic improvement in aneurysm obliteration in 26.6% of small aneurysms and 26.2% of large aneurysms. CONCLUSIONS: First-generation HydroCoil treatment of intracranial aneurysms has a favorable rate of recanalization compared with most large series of pure platinum coils with similar complication rates.


Asunto(s)
Materiales Biocompatibles Revestidos/uso terapéutico , Embolización Terapéutica/instrumentación , Embolización Terapéutica/estadística & datos numéricos , Hidrogeles/uso terapéutico , Aneurisma Intracraneal/epidemiología , Aneurisma Intracraneal/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Cerebral/estadística & datos numéricos , Niño , Preescolar , Femenino , Georgia/epidemiología , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
11.
Interv Neuroradiol ; 8(3): 299-304, 2002 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-20594488

RESUMEN

SUMMARY: We present a case of recurrent carotid-cavernous fistula after prior ipsilateral carotid artery ligation. Due to lack of endovascular access, embolization was performed by direct puncture of the cavernous sinus via a transorbital approach. Operative technique and an anatomical basis for treatment are described.

12.
Interv Neuroradiol ; 8(2): 209-12, 2002 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-20594532

RESUMEN

SUMMARY: A 74-year-old woman with a direct carotidcavernous fistula secondary to aneurysm rupture was treated by endovascular balloon occlusion of the fistula. Two days later, she suffered an intracerebral hemorrhage ipsilateral to the treated carotid cavernous fistula, perhaps due to normal perfusion pressure breakthrough. Normal perfusion pressure breakthrough has been described as a cause of hemorrhage following treatment of arteriovenous malformations (1) and carotid stenosis (2,3). We report an unusual case of therapeutic endovascular occlusion of a direct carotid-cavernous fistula complicated by hemorrhage presumably caused by normal pressure perfusion breakthrough.

13.
J Vasc Surg ; 34(5): 939-42, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11700498

RESUMEN

Thrombin injection as a means of inducing thrombus formation has recently received wide attention as an alternative treatment for pseudoaneurysm. We present a case of a 67-year-old man in whom a large mycotic pseudoaneurysm developed in the ascending aorta because of sternal osteomyelitis and mediastinitis after coronary artery bypass grafting. Transcatheter intra-arterial thrombin injection was performed, and it successfully induced pseudoaneurysm thrombosis. However, the procedure was complicated by a sudden transient ischemic attack caused by thrombus propagation into the cerebral circulation. Complete thrombus dissolution in the cerebral circulation with the resolution of neurologic symptoms was achieved by means of intravenous abciximab.


Asunto(s)
Aneurisma Falso/tratamiento farmacológico , Aneurisma Infectado/tratamiento farmacológico , Anticuerpos Monoclonales/uso terapéutico , Aneurisma de la Aorta Torácica/tratamiento farmacológico , Hemostáticos/administración & dosificación , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Ataque Isquémico Transitorio/tratamiento farmacológico , Ataque Isquémico Transitorio/etiología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Trombina/administración & dosificación , Abciximab , Anciano , Hemostáticos/uso terapéutico , Humanos , Inyecciones Intraarteriales , Masculino , Trombina/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA