Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Rev Med Chil ; 146(2): 190-195, 2018 Feb.
Artículo en Español | MEDLINE | ID: mdl-29999155

RESUMEN

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. AIM: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. MATERIAL AND METHODS: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). RESULTS: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was -0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and -0.9 mmHg (95% CI -1.7 to -0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. CONCLUSIONS: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea , Hipertensión/diagnóstico , Determinación de la Presión Sanguínea/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
2.
Rev Med Chil ; 141(11): 1420-6, 2013 Nov.
Artículo en Español | MEDLINE | ID: mdl-24718468

RESUMEN

BACKGROUND: Patients who have suffered multiple traumatic injuries, have a serious risk for death. Hypothermia, acidosis and coagulopathy are three complications in these patients, whose presence is known as lethal triad and indicates bad prognosis. AIM: To determine if the lethal triad in multiple trauma patients is associated with higher mortality and Injury Score Severity (ISS). MATERIAL AND METHODS: One hundred multiple trauma patients aged 26 to 56 years (90 males), admitted to an emergency room, were studied. Body temperature, prothrombin time, partial thromboplastin time, platelet count and blood gases were determined on admission. RESULTS: Twenty six patients had the lethal triad and 15% died in the emergency room within the first 6 hours. No death was recorded among the 74 patients without the lethal triad. The mean ISS among patients with and without the lethal triad was 31.7 and 25.6, respectively (p < 0.05). CONCLUSIONS: The presence of the lethal triad among patients with multiple trauma is associated with a higher mortality and ISS.


Asunto(s)
Acidosis/etiología , Trastornos de la Coagulación Sanguínea/etiología , Hipotermia/etiología , Traumatismo Múltiple/complicaciones , Acidosis/mortalidad , Adolescente , Adulto , Trastornos de la Coagulación Sanguínea/mortalidad , Servicio de Urgencia en Hospital , Femenino , Humanos , Hipotermia/mortalidad , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Traumatismo Múltiple/mortalidad , Pronóstico , Factores de Riesgo , Análisis de Supervivencia , Adulto Joven
3.
Healthcare (Basel) ; 10(10)2022 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-36292451

RESUMEN

Background: Muscle wasting, also known as myopenia, is frequent in rheumatoid arthritis (RA). To date, it is still unknown if the failure of pharmacologic therapies increases the risk of myopenia in RA. Objective: To identify if treatment failure with conventional synthetic DMARDs (csDMARDs) constitutes an independent risk factor of muscle wasting in women with RA. Methods: This was a cross-sectional study. We included 277 women with RA. Assessments in RA patients included: clinical, epidemiological, and therapeutic variables. The skeletal muscle index (SMI) was estimated by DXA, and myopenia was diagnosed if they had an SMI < 5.45 kg/m2. Multivariable logistic regression models identified risk factors of myopenia. Results: Muscle wasting was observed in 28.2% of patients with RA. The risk factors of myopenia in RA were menopausal (OR: 4.45, 95% CI: 1.86 to 10.64) and failure of combined therapy with csDMARDs (OR: 2.42, 95% CI: 1.15 to 5.07). The increased body mass index was protective (OR:0.81, 95% CI: 0.75 to 0.87). Conclusions: Around one of four patients with RA presented muscle wasting. Muscle wasting is related to treatment failure of combined csDMARDs; other factors influencing the presence of muscle wasting is being postmenopausal, whereas, the body mass index was a protective factor.

4.
Sci Rep ; 12(1): 1877, 2022 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-35115601

RESUMEN

There is a significant rate of therapeutic failure in rheumatoid arthritis (RA) patients treated with leflunomide (LEF). This study investigates the utility values of teriflunomide levels (A77 1726) in identifying RA patients who remained with moderate or severe disease activity after the treatment with LEF. In this cross-sectional study, we compared: (a) RA patients who achieved a DAS28-ESR ≤ 3.2, and (b) RA patients who maintained a DAS28-ESR > 3.2 after treatment. ROC curves determined the cut-off of A77 1726 with the better performance to identify patients achieving a DAS28-ESR ≤ 3.2. Of the 115 patients treated with LEF, 69 (60%) remained with moderate/severe disease activity and 46 (40%) achieved low disease activity/remission. Higher A77 1726 levels showed a negative correlation with DAS28-ESR (r = - 0.42, p < 0.001) and other parameters of disease activity. We obtained the following utility values with the cut-off of A77 1726 > 10 µg/mL to identify RA patients who achieved a DAS28-ESR ≤ 3.2: sensitivity of 91.31%; specificity of 73.91%; positive predictive value of 70.00%; and negative predictive value of 92.73%. Serum A77 1726 discriminated between RA patients who remained with moderate/severe disease activity despite the treatment with LEF both as monotherapy and LEF as combo therapy.


Asunto(s)
Antirreumáticos/uso terapéutico , Artritis Reumatoide/tratamiento farmacológico , Crotonatos/uso terapéutico , Hidroxibutiratos/uso terapéutico , Leflunamida/uso terapéutico , Nitrilos/uso terapéutico , Toluidinas/uso terapéutico , Adulto , Anciano , Antirreumáticos/efectos adversos , Antirreumáticos/sangre , Artritis Reumatoide/sangre , Artritis Reumatoide/diagnóstico , Estudios Transversales , Crotonatos/efectos adversos , Crotonatos/sangre , Monitoreo de Drogas , Quimioterapia Combinada , Femenino , Humanos , Hidroxibutiratos/efectos adversos , Hidroxibutiratos/sangre , Leflunamida/efectos adversos , Leflunamida/sangre , Masculino , Persona de Mediana Edad , Nitrilos/efectos adversos , Nitrilos/sangre , Valor Predictivo de las Pruebas , Inducción de Remisión , Índice de Severidad de la Enfermedad , Factores de Tiempo , Toluidinas/efectos adversos , Toluidinas/sangre , Resultado del Tratamiento
5.
J Immunol Res ; 2020: 8982163, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32377539

RESUMEN

BACKGROUND: Neuropeptide Y (NPY) is a sympathetic neurotransmitter with effects on the regulation of inflammatory cells. The role of NPY on autoimmune inflammatory diseases such as rheumatoid arthritis (RA) is not completely understood. Therefore, we evaluate if NPY levels are markers of disease activity in RA and if there is a correlation between NPY levels and tumor necrosis factor-alpha (TNF-α), leptin, and interleukin 6 (IL-6) levels. METHODS: Cross-sectional design, including 108 women with RA. We assessed disease activity by DAS28-ESR (considering active disease a score of ≥2.6). Serum NPY levels and anti-CCP2 antibody, TNF-α, IL-6, and leptin levels were quantified (ELISA). RESULTS: Sixty-eight RA had an active disease (RA-active), and 40 were in remission (RA-remission). RA-active patients had higher NPY levels vs. RA-remission (22.8 ± 13.6 vs. 17.8 ± 10.3; p = 0.04). NPY levels correlated with increased TNF-α levels (r = 0.32, p = 0.001). Leptin or IL-6 did not correlate with NPY levels. In the logistic regression analysis, NPY increased the risk of disease activity (OR: 1.04, 95% CI 1.006-1.09, and p = 0.03). CONCLUSION: Higher NPY levels are an independent marker of disease activity in RA. This study encourages the quantification of NPY levels as a surrogate marker for RA-active. Future studies evaluating the role of NPY levels interacting with other proinflammatory cytokines are required.


Asunto(s)
Artritis Reumatoide/inmunología , Enfermedades Autoinmunes/inmunología , Biomarcadores/sangre , Neuropéptido Y/sangre , Factor de Necrosis Tumoral alfa/sangre , Adulto , Anciano , Artritis Reumatoide/diagnóstico , Enfermedades Autoinmunes/diagnóstico , Proteína C-Reactiva/metabolismo , Estudios Transversales , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis de Regresión , Factor de Necrosis Tumoral alfa/metabolismo
6.
Blood Press Monit ; 22(6): 375-378, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28945665

RESUMEN

OBJECTIVE: The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. PARTICIPANTS AND METHODS: The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). RESULTS: The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea , Esfigmomanometros/normas , Adulto , Anciano , Instituciones de Atención Ambulatoria , Brazo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Autocuidado/instrumentación
7.
J Plast Surg Hand Surg ; 50(4): 222-6, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26982891

RESUMEN

Background Reparation of large nasal septum perforations continues to be challenging. Bipedicled mucoperichondrial and inter-positional grafts currently show the most promising results. New implants have emerged to be used as a support membrane to carry on the mucosal cells, taking advantage of the innate proliferative properties of the mucosal tissue. Objective To compare the effectiveness of two kinds of material; non-absorbable dimethylsiloxane (silicone elastomers) and absorbable porcine small intestinal submucosa (Surgisis), both used as an inter-positional graft without neighbouring flaps to close nasal septal perforations in an experimental model. Methods Fifteen dogs were divided into three groups. One group received Surgisis, the other sheets of dimethylsiloxane and the last group a sham group. The dogs were followed for 6 weeks. Results The initial perforation of the nasal septum showed complete mucosal closure in the dimethylsiloxane group. The Surgisis group, on the other hand, had a smaller reduction than that at the beginning (final mean area = 23.0 ± 5.4 mm(2) (p < 0.05); however, complete closure was not achieved. Sham animals showed an inconstant and slight reduction in dimension from 100 mm(2) to 70 ± 16 mm(2) of mucosa and cartilage, but closure was not achieved. A significantly higher number of capillaries were observed in the Surgisis group compared to the dimethylsiloxane group (p < 0.05) without differences in inflammation, fibrosis, or necrosis. Conclusions The non-absorbable implant; dimethylsiloxane facilitates a better closure of the nasal septum.


Asunto(s)
Implantes Absorbibles , Colágeno , Dimetilpolisiloxanos , Perforación del Tabique Nasal/cirugía , Tabique Nasal/cirugía , Prótesis e Implantes , Animales , Perros , Mucosa Intestinal , Modelos Animales , Mucosa Nasal/anatomía & histología , Rinoplastia/métodos , Porcinos
9.
Rev. méd. Chile ; 146(2): 190-195, feb. 2018. tab, graf
Artículo en Español | LILACS | ID: biblio-961377

RESUMEN

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. Aim: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. Material and Methods: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). Results: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was −0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and −0.9 mmHg (95% CI −1.7 to −0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. Conclusions: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea , Hipertensión/diagnóstico , Determinación de la Presión Sanguínea/métodos , Estudios Transversales , Reproducibilidad de los Resultados
10.
Rev. méd. Chile ; 141(11): 1420-1426, nov. 2013. tab
Artículo en Español | LILACS | ID: lil-704569

RESUMEN

Background: Patients who have suffered multiple traumatic injuries, have a serious risk for death. Hypothermia, acidosis and coagulopathy are three complications in these patients, whose presence is known as lethal triad and indicates bad prognosis.Aim: To determine if the lethal triad in multiple trauma patients is associated withhigher mortality and Injury Score Severity (ISS). Material and Methods: Onehundred multiple trauma patients aged 26 to 56 years (90 males), admitted toan emergency room, were studied. Body temperature, prothrombin time, partialthromboplastin time, platelet count and blood gases were determined on admission.Results: Twenty six patients had the lethal triad and 15% died in the emergencyroom within the first 6 hours. No death was recorded among the 74 patients withoutthe lethal triad. The mean ISS among patients with and without the lethal triad was31.7 and 25.6, respectively (p < 0.05). Conclusions: The presence of the lethal triadamong patients with multiple trauma is associated with a higher mortality and ISS.


Asunto(s)
Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Acidosis/etiología , Trastornos de la Coagulación Sanguínea/etiología , Hipotermia/etiología , Traumatismo Múltiple/complicaciones , Acidosis/mortalidad , Trastornos de la Coagulación Sanguínea/mortalidad , Servicio de Urgencia en Hospital , Hipotermia/mortalidad , Puntaje de Gravedad del Traumatismo , Traumatismo Múltiple/mortalidad , Pronóstico , Factores de Riesgo , Análisis de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA