Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Infect Dis ; 19(1): 83, 2019 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-30678651

RESUMEN

BACKGROUND: The understanding of early events following TB exposure is limited by traditional tests that rely on detection of an immune response to infection, which is delayed, or on imaging tests with low sensitivity for early disease. We investigated for evidence of lung abnormalities in heavily exposed TB contacts using PET/MRI. METHODS: 30 household contacts of 20 index patients underwent clinical assessment, IGRA testing, chest x-ray and PET/MRI scan using 18-F-FDG. MRI images were examined by a radiology/nuclear medicine dual-qualified physician using a standardised report form, while PET/MRI images were examined independently by another radiology/nuclear medicine dual-qualified physician using a similar form. Standardised uptake value (SUV) was quantified for each abnormal lesion. RESULTS: IGRA was positive in 40%. PET/MRI scan was abnormal in 30%, predominantly FDG uptake in hilar or mediastinal lymph nodes and lung apices. We did not identify any relationship between PET/MRI findings and degree of exposure or IGRA status. CONCLUSION: PET-based imaging may provide important insights into the natural history following exposure to TB that may not be available from traditional tests of TB immune response or imaging. The clinical significance of the abnormalities is uncertain and merits further investigation in longitudinal studies.


Asunto(s)
Tuberculosis Pulmonar/diagnóstico por imagen , Adulto , Anciano , Trazado de Contacto , Composición Familiar , Femenino , Fluorodesoxiglucosa F18/administración & dosificación , Humanos , Ganglios Linfáticos/patología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Radiofármacos/administración & dosificación , Tuberculosis Pulmonar/diagnóstico , Tuberculosis Pulmonar/transmisión , Adulto Joven
2.
J Nucl Cardiol ; 25(6): 2001-2011, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-28500539

RESUMEN

BACKGROUND: Following an acute coronary syndrome, combined CT and PET with 18F-NaF can identify coronary atherosclerotic plaques that have ruptured or eroded. However, the processes behind 18F-NaF uptake in vulnerable plaques remain unclear. METHODS AND RESULTS: Ten patients with STEMI were scanned after 18F-NaF injection, for 75 minutes in a Siemens PET/MR scanner using delayed enhancement (LGE). They were then scanned in a Siemens PET/CT scanner for 10 minutes. Tissue-to-background ratio (TBR) was compared between the culprit lesion in the IRA and remote non-culprit lesions in an effort to independently validate prior studies. Additionally, we performed a proof-of-principle study comparing TBR in scar tissue and remote myocardium using LGE images and PET/MR or PET/CT data. From the 33 coronary lesions detected on PET/CT, TBRs for culprit lesions were higher than for non-culprit lesions (TBR = 2.11 ± 0.45 vs 1.46 ± 0.48; P < 0.001). Interestingly, the TBR measured on the PET/CT was higher for infarcted myocardium than for remote myocardium (TBR = 0.81 ± 0.10 vs 0.71 ± 0.05; P = 0.003). These results were confirmed using the PET/MR data (TBR = 0.81 ± 0.10 for scar, TBR = 0.71 ± 0.06 for healthy myocardium, P = 0.03). CONCLUSIONS: We confirmed the potential of 18F-NaF PET/CT imaging to detect vulnerable coronary lesions. Moreover, we demonstrated proof-of-principle that 18F-NaF concurrently detects myocardial scar tissue.


Asunto(s)
Cicatriz/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Infarto del Miocardio/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Femenino , Radioisótopos de Flúor , Humanos , Masculino , Persona de Mediana Edad , Fluoruro de Sodio
3.
Eur J Nucl Med Mol Imaging ; 43(13): 2374-2380, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27557845

RESUMEN

PURPOSE: To dynamically detect and characterize 18F-fluorodeoxyglucose (FDG) dose infiltrations and evaluate their effects on positron emission tomography (PET) standardized uptake values (SUV) at the injection site and in control tissue. METHODS: Investigational gamma scintillation sensors were topically applied to patients with locally advanced breast cancer scheduled to undergo limited whole-body FDG-PET as part of an ongoing clinical study. Relative to the affected breast, sensors were placed on the contralateral injection arm and ipsilateral control arm during the resting uptake phase prior to each patient's PET scan. Time-activity curves (TACs) from the sensors were integrated at varying intervals (0-10, 0-20, 0-30, 0-40, and 30-40 min) post-FDG and the resulting areas under the curve (AUCs) were compared to SUVs obtained from PET. RESULTS: In cases of infiltration, observed in three sensor recordings (30 %), the injection arm TAC shape varied depending on the extent and severity of infiltration. In two of these cases, TAC characteristics suggested the infiltration was partially resolving prior to image acquisition, although it was still apparent on subsequent PET. Areas under the TAC 0-10 and 0-20 min post-FDG were significantly different in infiltrated versus non-infiltrated cases (Mann-Whitney, p < 0.05). When normalized to control, all TAC integration intervals from the injection arm were significantly correlated with SUVpeak and SUVmax measured over the infiltration site (Spearman ρ ≥ 0.77, p < 0.05). Receiver operating characteristic (ROC) analyses, testing the ability of the first 10 min of post-FDG sensor data to predict infiltration visibility on the ensuing PET, yielded an area under the ROC curve of 0.92. CONCLUSIONS: Topical sensors applied near the injection site provide dynamic information from the time of FDG administration through the uptake period and may be useful in detecting infiltrations regardless of PET image field of view. This dynamic information may also complement the static PET image to better characterize the true extent of infiltrations.


Asunto(s)
Neoplasias de la Mama/metabolismo , Fluorodesoxiglucosa F18/administración & dosificación , Fluorodesoxiglucosa F18/farmacocinética , Radiofármacos/farmacocinética , Conteo por Cintilación/instrumentación , Absorción Fisiológica , Neoplasias de la Mama/diagnóstico por imagen , Sistemas de Computación , Monitoreo de Drogas/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Inyecciones , Tasa de Depuración Metabólica , Dosis de Radiación , Radiofármacos/administración & dosificación , Reproducibilidad de los Resultados , Conteo por Cintilación/métodos , Sensibilidad y Especificidad , Distribución Tisular
4.
Blood ; 116(13): 2241-4, 2010 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-20522711

RESUMEN

Care of patients with AL amyloidosis currently is limited by the lack of objective means to document disease extent, as well as therapeutic options that expedite removal of pathologic deposits. To address these issues, we have initiated a Phase I Exploratory IND study to determine the biodistribution of the fibril-reactive, amyloidolytic murine IgG1 mAb 11-1F4 labeled with I-124. Patients were infused with less than 1 mg (∼ 74 MBq) of GMP-grade antibody and imaged by PET/CT scan 48 and 120 hours later. Among 9 of 18 subjects, there was striking uptake of the reagent in liver, lymph nodes, bone marrow, intestine, or, unexpectedly, spleen (but not kidneys or heart). Generally, positive or negative results correlated with those obtained immunohistochemically using diagnostic tissue biopsy specimens. Based on these findings, we posit that (124)I-mAb m11-1F4 can be used to identify AL candidates for passive immunotherapy using the chimeric form of the antibody.


Asunto(s)
Amiloide/metabolismo , Amiloidosis/diagnóstico por imagen , Amiloidosis/metabolismo , Anciano , Animales , Anticuerpos Monoclonales , Drogas en Investigación , Femenino , Humanos , Inmunoglobulina G , Radioisótopos de Yodo , Masculino , Ratones , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Radioinmunodetección , Distribución Tisular
5.
Phys Med ; 81: 285-294, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33341375

RESUMEN

PURPOSE: To conduct a simplified lesion-detection task of a low-dose (LD) PET-CT protocol for frequent lung screening using 30% of the effective PETCT dose and to investigate the feasibility of increasing clinical value of low-statistics scans using machine learning. METHODS: We acquired 33 SD PET images, of which 13 had actual LD (ALD) PET, and simulated LD (SLD) PET images at seven different count levels from the SD PET scans. We employed image quality transfer (IQT), a machine learning algorithm that performs patch-regression to map parameters from low-quality to high-quality images. At each count level, patches extracted from 23 pairs of SD/SLD PET images were used to train three IQT models - global linear, single tree, and random forest regressions with cubic patch sizes of 3 and 5 voxels. The models were then used to estimate SD images from LD images at each count level for 10 unseen subjects. Lesion-detection task was carried out on matched lesion-present and lesion-absent images. RESULTS: LD PET-CT protocol yielded lesion detectability with sensitivity of 0.98 and specificity of 1. Random forest algorithm with cubic patch size of 5 allowed further 11.7% reduction in the effective PETCT dose without compromising lesion detectability, but underestimated SUV by 30%. CONCLUSION: LD PET-CT protocol was validated for lesion detection using ALD PET scans. Substantial image quality improvement or additional dose reduction while preserving clinical values can be achieved using machine learning methods though SUV quantification may be biased and adjustment of our research protocol is required for clinical use.


Asunto(s)
Neoplasias Pulmonares , Tomografía Computarizada por Tomografía de Emisión de Positrones , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Aprendizaje Automático , Tomografía de Emisión de Positrones
6.
J Nucl Med ; 50(8): 1315-23, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19617317

RESUMEN

UNLABELLED: Time-of-flight (TOF) PET uses very fast detectors to improve localization of events along coincidence lines-of-response. This information is then utilized to improve the tomographic reconstruction. This work evaluates the effect of TOF upon an observer's performance for detecting and localizing focal warm lesions in noisy PET images. METHODS: An advanced anthropomorphic lesion-detection phantom was scanned 12 times over 3 days on a prototype TOF PET/CT scanner (Siemens Medical Solutions). The phantom was devised to mimic whole-body oncologic (18)F-FDG PET imaging, and a number of spheric lesions (diameters 6-16 mm) were distributed throughout the phantom. The data were reconstructed with the baseline line-of-response ordered-subsets expectation-maximization algorithm, with the baseline algorithm plus point spread function model (PSF), baseline plus TOF, and with both PSF+TOF. The lesion-detection performance of each reconstruction was compared and ranked using localization receiver operating characteristics (LROC) analysis with both human and numeric observers. The phantom results were then subjectively compared to 2 illustrative patient scans reconstructed with PSF and with PSF+TOF. RESULTS: Inclusion of TOF information provides a significant improvement in the area under the LROC curve compared to the baseline algorithm without TOF data (P = 0.002), providing a degree of improvement similar to that obtained with the PSF model. Use of both PSF+TOF together provided a cumulative benefit in lesion-detection performance, significantly outperforming either PSF or TOF alone (P < 0.002). Example patient images reflected the same image characteristics that gave rise to improved performance in the phantom data. CONCLUSION: Time-of-flight PET provides a significant improvement in observer performance for detecting focal warm lesions in a noisy background. These improvements in image quality can be expected to improve performance for the clinical tasks of detecting lesions and staging disease. Further study in a large clinical population is warranted to assess the benefit of TOF for various patient sizes and count levels, and to demonstrate effective performance in the clinical environment.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Eur J Nucl Med Mol Imaging ; 36 Suppl 1: S15-29, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19104808

RESUMEN

INTRODUCTION: Since their introduction in 2001, PET/CT systems have gained wide acceptance primarily due to their inherent ability to combine functional and structural information about the underlying disease state of the patient in a single imaging session. Their significance has also been documented with regard to their short imaging times, which minimize patient anxiety and image blurring due to patient motion. In the past seven years, PET/CT systems have replaced dedicated PET systems as the imaging modality of choice for diagnostic evaluation of oncology patients. OBJECTIVES: The purpose of this article is to review the evolution of PET/CT systems and document their current status. DISCUSSION: Recent improvements in instrumentation are highlighted together with some outstanding issues that arise for specific PET/CT applications. These are followed by a description of some of the more common clinical applications of PET/CT imaging such as staging malignant disease, treatment planning, and monitoring therapy response. Finally, the future developments of PET/CT systems with regard to sensitivity, resolution, and new radiopharmaceuticals are discussed. The article concludes by presenting some issues concerning the next stage in the future of PET imaging, namely PET/MRI.


Asunto(s)
Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Diseño de Equipo , Humanos , Imagen por Resonancia Magnética/tendencias , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/tendencias , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/tendencias
8.
Harmful Algae ; 88: 101656, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31582158

RESUMEN

The toxic diatom genus Pseudo-nitzschia is a growing presence in the Gulf of Maine (GOM), where regionally unprecedented levels of domoic acid (DA) in 2016 led to the first Amnesic Shellfish Poisoning closures in the region. However, factors driving GOM Pseudo-nitzschia dynamics, DA concentrations, and the 2016 event are unclear. Water samples were collected at the surface and at depth in offshore transects in summer 2012, 2014, and 2015, and fall 2016, and a weekly time series of surface water samples was collected in 2013. Temperature and salinity data were obtained from NERACOOS buoys and measurements during sample collection. Samples were processed for particulate DA (pDA), dissolved nutrients (nitrate, ammonium, silicic acid, and phosphate), and cellular abundance. Species composition was estimated via Automated Ribosomal Intergenic Spacer Analysis (ARISA), a semi-quantitative DNA finger-printing tool. Pseudo-nitzschia biogeography was consistent in the years 2012, 2014, and 2015, with greater Pseudo-nitzschia cell abundance and P. plurisecta dominance in low-salinity inshore samples, and lower Pseudo-nitzschia cell abundance and P. delicatissima and P. seriata dominance in high-salinity offshore samples. During the 2016 event, pDA concentrations were an order of magnitude higher than in previous years, and inshore-offshore contrasts in biogeography were weak, with P. australis present in every sample. Patterns in temporal and spatial variability confirm that pDA increases with the abundance and the cellular DA of Pseudo-nitzschia species, but was not correlated with any one environmental factor. The greater pDA in 2016 was caused by P. australis - the observation of which is unprecedented in the region - and may have been exacerbated by low residual silicic acid. The novel presence of P. australis may be due to local growth conditions, the introduction of a population with an anomalous water mass, or both factors. A definitive cause of the 2016 bloom remains unknown, and continued DA monitoring in the GOM is warranted.


Asunto(s)
Diatomeas , Intoxicación por Mariscos , Humanos , Maine , Nitratos , Estaciones del Año
9.
J Nucl Med Technol ; 47(4): 326-331, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31182666

RESUMEN

PET/CT radiotracer infiltration is not uncommon and is often outside the imaging field of view. Infiltration can negatively affect image quality, image quantification, and patient management. Until recently, there has not been a simple way to routinely practice PET radiopharmaceutical administration quality control and quality assurance. Our objectives were to quantify infiltration rates, determine associative factors for infiltration, and assess whether rates could be reduced at multiple centers and then sustained. Methods: A "design, measure, analyze, improve, and control" quality improvement methodology requiring novel technology was used to try to improve PET/CT injection quality. Teams were educated on the importance of quality injections. Baseline infiltration rates were measured, center-specific associative factors were analyzed, team meetings were held, improvement plans were established and executed, and rates remeasured. To ensure that injection-quality gains were retained, real-time feedback and ongoing monitoring were used. Sustainability was assessed. Results: Seven centers and 56 technologists provided data on 5,541 injections. The centers' aggregated baseline infiltration rate was 6.2% (range, 2%-16%). On the basis of their specific associative factors, 4 centers developed improvement plans and reduced their aggregated infiltration rate from 8.9% to 4.6% (P < 0.0001). Ongoing injection monitoring showed sustainability. Significant variation was found in center- and technologist-level infiltration rates (P < 0.0001 and P = 0.0020, respectively). Conclusion: A quality improvement approach with new technology can help centers measure infiltration rates, determine associative factors, implement interventions, and improve and sustain injection quality. Because PET/CT images help guide patient management, the monitoring and improvement of radiotracer injection quality are important.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones/instrumentación , Humanos , Inyecciones , Control de Calidad , Dosis de Radiación
10.
J Nucl Med ; 49(6): 938-55, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18483101

RESUMEN

The extensive development of image fusion techniques over the past 20 y has shown that the fusion of images from complementary modalities offers a more complete and accurate assessment of disease than do images from a single modality. Although software techniques have been successful in fusing images of the brain from different modalities, they have achieved rather limited success for other parts of the body. The recent introduction of technology that can acquire both anatomic and functional images in a single scan has addressed many of the limitations of software fusion. The combination of CT and PET was introduced commercially in 2001, followed by CT and SPECT in 2004. Clinical adoption of PET/CT has been surprisingly rapid, and despite continuing debate, the new technology has advanced the use of clinical molecular imaging, particularly for oncology.


Asunto(s)
Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Tomografía de Emisión de Positrones/tendencias , Técnica de Sustracción/tendencias , Tomografía Computarizada por Rayos X/tendencias , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/métodos , Técnica de Sustracción/instrumentación , Evaluación de la Tecnología Biomédica , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
11.
Semin Nucl Med ; 38(3): 152-66, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18396176

RESUMEN

Accurate anatomical localization of functional abnormalities obtained with the use of positron emission tomography (PET) is known to be problematic. Although tracers such as (18)F-fluorodeoxyglucose ((18)F-FDG) visualize certain normal anatomical structures, the spatial resolution is generally inadequate for accurate anatomic localization of pathology. Combining PET with a high-resolution anatomical imaging modality such as computed tomography (CT) can resolve the localization issue as long as the images from the two modalities are accurately coregistered. However, software-based registration techniques have difficulty accounting for differences in patient positioning and involuntary movement of internal organs, often necessitating labor-intensive nonlinear mapping that may not converge to a satisfactory result. Acquiring both CT and PET images in the same scanner obviates the need for software registration and routinely provides accurately aligned images of anatomy and function in a single scan. A CT scanner positioned in line with a PET scanner and with a common patient couch and operating console has provided a practical solution to anatomical and functional image registration. Axial translation of the couch between the 2 modalities enables both CT and PET data to be acquired during a single imaging session. In addition, the CT images can be used to generate essentially noiseless attenuation correction factors for the PET emission data. By minimizing patient movement between the CT and PET scans and accounting for the axial separation of the two modalities, accurately registered anatomical and functional images can be obtained. Since the introduction of the first PET/CT prototype more than 6 years ago, numerous patients with cancer have been scanned on commercial PET/CT devices worldwide. The commercial designs feature multidetector spiral CT and high-performance PET components. Experience has demonstrated an increased level of accuracy and confidence in the interpretation of the combined study as compared with studies acquired separately, particularly in distinguishing pathology from normal, physiologic tracer uptake and precisely localizing abnormal foci. Combined PET/CT scanners represent an important evolution in technology that has helped to bring molecular imaging to the forefront in cancer diagnosis, staging and therapy monitoring.


Asunto(s)
Artefactos , Tomografía de Emisión de Positrones/tendencias , Técnica de Sustracción/instrumentación , Tomografía Computarizada por Rayos X/tendencias , Protocolos Antineoplásicos , Humanos , Procesamiento de Imagen Asistido por Computador/tendencias , Movimiento (Física) , Estadificación de Neoplasias/instrumentación , Estadificación de Neoplasias/tendencias , Neoplasias/diagnóstico por imagen , Medicina Nuclear/tendencias , Tomografía de Emisión de Positrones/instrumentación , Radiofármacos/farmacocinética , Tecnología Radiológica/instrumentación , Tecnología Radiológica/tendencias , Tomógrafos Computarizados por Rayos X/tendencias , Tomografía Computarizada por Rayos X/instrumentación
12.
Harmful Algae ; 8(1): 39-53, 2008 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-19956363

RESUMEN

Coastal waters of the United States (U.S.) are subject to many of the major harmful algal bloom (HAB) poisoning syndromes and impacts. These include paralytic shellfish poisoning (PSP), neurotoxic shellfish poisoning (NSP), amnesic shellfish poisoning (ASP), ciguatera fish poisoning (CFP) and various other HAB phenomena such as fish kills, loss of submerged vegetation, shellfish mortalities, and widespread marine mammal mortalities. Here, the occurrences of selected HABs in a selected set of regions are described in terms of their relationship to eutrophication, illustrating a range of responses. Evidence suggestive of changes in the frequency, extent or magnitude of HABs in these areas is explored in the context of the nutrient sources underlying those blooms, both natural and anthropogenic. In some regions of the U.S., the linkages between HABs and eutrophication are clear and well documented, whereas in others, information is limited, thereby highlighting important areas for further research.

13.
Semin Ultrasound CT MR ; 29(4): 232-5, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18795489

RESUMEN

The 1990s witnessed the development of the first dual-modality imaging devices for clinical applications. A combined PET-CT prototype underwent clinical evaluation from mid-1998 onward. The results from the three-year evaluation program stimulated the demand for commercial designs and in 2001 the first commercial PET-CT scanner was installed in the clinic. The availability of designs from all the major vendors of medical imaging equipment was followed by a rapid adoption of the technology and today, over 2500 PET-CT scanners are in clinical operation world-wide. This article briefly summarizes the short history of PET-CT, and reviews the current status of the technology.


Asunto(s)
Tomografía de Emisión de Positrones/historia , Tomografía Computarizada por Rayos X/historia , Historia del Siglo XX , Historia del Siglo XXI , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos
14.
Front Med (Lausanne) ; 5: 303, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30443549

RESUMEN

Background: Infiltrations of 18F-fluorodeoxyglucose (FDG) injections affect positron emission tomography/computed tomography (PET/CT) image quality and quantification. A device using scintillation sensors (Lucerno Dynamics, Cary, NC) provides dynamic measurements acquired during FDG uptake to identify and characterize radioactivity near the injection site prior to patient imaging. Our aim was to compare sensor measurements against dynamic PET image acquisition, our proposed reference in assessing injection quality during the uptake period. Methods: Subjects undergoing routine FDG PET/CT imaging were eligible for this Institutional Review Board approved prospective study. After providing informed consent, subjects had sensors topically placed on their arms. FDG was injected into subjects' veins directly on the PET imaging table. Dynamic images of the injection site were acquired during 45 min of the uptake period. These dynamic image acquisitions and subjects' routine standard static images were evaluated by nuclear medicine physicians for abnormal FDG accumulation near the injection site. Sensor measurements were interpreted independently by Lucerno staff. Dynamic image acquisition interpretation results were compared to the sensor measurement interpretations and to static image interpretations. Results: Twenty-four subjects were consented and enrolled. Data from 21 subjects were gathered. During dynamic image acquisition review, physicians interpreted 4 subjects with no FDG accumulation at the injection site, whereas 17 showed evidence of accumulation. In 10 of the 17 cases that showed FDG accumulation, the FDG presence at the injection site resolved completely during uptake corresponding to venous stasis, the temporary sequestration of blood from circulation. Static image interpretation agreed with dynamic images interpretation in 11/21 (52%) subjects. Sensor measurement interpretations agreed with the dynamic images interpretations in 18/21 (86%) subjects. Conclusions: Sensor measurements can be an effective way to identify and characterize infiltrations and venous stasis. Comparable to an infiltration, venous stasis may produce spurious and clinically meaningful measurement bias and possibly even scan misinterpretation. Since the quality and quantification of PET/CT studies are of clinical importance, sensor measurements acquired during the FDG uptake may prove to be a useful quality control measure to reduce infiltration rates and potentially improve patient care. Registration: Clinicaltrials.gov, Identifier: NCT03041090.

15.
J Nucl Med ; 59(11): 1761-1767, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29653974

RESUMEN

Head motion occurring during brain PET studies leads to image blurring and to bias in measured local quantities. The objective of this work was to implement a correction method for PET data acquired with the mMR synchronous PET/MR scanner. Methods: A list-mode-based motion-correction approach has been designed. The developed rebinner chronologically reads the recorded events from the Siemens list-mode file, applies the estimated geometric transformations, and frames the detected counts into sinograms. The rigid-body motion parameters were estimated from an initial dynamic reconstruction of the PET data. We then optimized the correction for 11C-Pittsburgh compound B (11C-PIB) scans using simulated and actual data with well-controlled motion. Results: An efficient list-mode-based motion correction approach has been implemented, fully optimized, and validated using simulated and actual PET data. The average spatial resolution loss induced by inaccuracies in motion parameter estimates and by the rebinning process was estimated to correspond to a 1-mm increase in full width at half maximum with motion parameters estimated directly from the PET data with a temporal frequency of 20 s. The results show that the rebinner can be safely applied to the 11C-PIB scans, allowing almost complete removal of motion-induced artifacts. The application of the correction method to a large cohort of 11C-PIB scans led to the following observations: first, that more than 21% of the scans were affected by motion greater than 10 mm (39% for subjects with Mini-Mental State Examination scores below 20), and second, that the correction led to quantitative changes in Alzheimer-specific cortical regions of up to 30%. Conclusion: The rebinner allows accurate motion correction at a cost of minimal resolution reduction. Application of the correction to a large cohort of 11C-PIB scans confirmed the necessity of systematically correcting for motion to obtain quantitative results.


Asunto(s)
Benzotiazoles , Tomografía de Emisión de Positrones/estadística & datos numéricos , Radiofármacos , Compuestos de Anilina , Encéfalo/diagnóstico por imagen , Radioisótopos de Carbono , Estudios de Cohortes , Simulación por Computador , Movimientos de la Cabeza , Humanos , Interpretación de Imagen Asistida por Computador/estadística & datos numéricos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/estadística & datos numéricos , Movimiento (Física) , Imagen Multimodal/instrumentación , Imagen Multimodal/estadística & datos numéricos , Neuroimagen/instrumentación , Neuroimagen/estadística & datos numéricos , Tomografía de Emisión de Positrones/instrumentación , Tiazoles
16.
Am J Clin Nutr ; 107(1): 62-70, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29381803

RESUMEN

Background: Capsinoids are reported to increase energy expenditure (EE) via brown adipose tissue (BAT) stimulation. However, imaging of BAT activation by capsinoids remains limited. Because BAT activation is a potential therapeutic strategy for obesity and related metabolic disorders, we sought to prove that capsinoid-induced BAT activation can be visualized by 18-fluorine fluorodeoxyglucose (18F-FDG) positron emission tomography (PET). Objective: We compared capsinoids and cold exposure on BAT activation and whole-body EE. Design: Twenty healthy participants (8 men, 12 women) with a mean age of 26 y (range: 21-35 y) and a body mass index (kg/m2) of 21.7 (range: 18.5-26.0) underwent 18F-FDG PET and whole-body calorimetry after ingestion of 12 mg capsinoids or ≤2 h of cold exposure (∼14.5°C) in a crossover design. Mean standardized uptake values (SUVs) of the region of interest and BAT volumes were calculated. Blood metabolites were measured before and 2 h after each treatment. Results: All of the participants showed negligible 18F-FDG uptake post-capsinoid ingestion. Upon cold exposure, 12 participants showed avid 18F-FDG uptake into supraclavicular and lateral neck adipose tissues (BAT-positive group), whereas the remaining 8 participants (BAT-negative group) showed undetectable uptake. Capsinoids and cold exposure increased EE, although cold induced a 2-fold increase in whole-body EE and higher fat oxidation, insulin sensitivity, and HDL cholesterol compared with capsinoids. Conclusions: Capsinoids only increased EE in BAT-positive participants, which suggests that BAT mediates EE evoked by capsinoids. This implies that capsinoids stimulate BAT to a lesser degree than cold exposure as evidenced by 18F-FDG uptake below the presently accepted SUV thresholds defining BAT activation. This trial was registered at www.clinicaltrials.gov as NCT02964442.


Asunto(s)
Tejido Adiposo Pardo/efectos de los fármacos , Adiposidad , Capsicum/química , Metabolismo Energético , Fluorodesoxiglucosa F18/farmacocinética , Tomografía de Emisión de Positrones , Tejido Adiposo Pardo/metabolismo , Adulto , Índice de Masa Corporal , Calorimetría Indirecta , Frío , Estudios Cruzados , Femenino , Fluorodesoxiglucosa F18/administración & dosificación , Humanos , Masculino , Ensayos Clínicos Controlados no Aleatorios como Asunto , Extractos Vegetales/administración & dosificación , Adulto Joven
17.
J Nucl Med ; 48(5): 744-51, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17475962

RESUMEN

UNLABELLED: PET and (18)F-FDG have the potential to follow the early metabolic response to chemotherapy in patients with non-small cell lung cancer and to predict success or failure of the therapy. METHODS: We studied 16 patients with non-small cell lung cancer as they followed 2 courses of docetaxel and carboplatin. Each patient was studied weekly for 7 wk, and tissue activity was assessed by the amount of radioactivity retained 90 min after the intravenous injection of (18)F-FDG. In a prospective analysis, the linear least-squares method was used to evaluate the time course of metabolic activity in tumor and liver, bone marrow, and unaffected lung tissues; a metabolic response was defined as a response in which the slope of the regression was negative and significantly different from zero. Our hypothesis was that patients who exhibited a tumor metabolic response would survive longer than those who did not. In a retrospective examination of our data, we grouped our patients into those who survived <6 mo and those who survived longer and calculated the difference in the standardized uptake value (SUV) between day 7 and subsequent time points to determine the most appropriate timing of 2 PET studies in predicting response to therapy. RESULTS: Fifteen of 16 patients completed the study. In the prospective study, 8 patients were classified as nonresponders as the slope of the regression of tumor SUV versus time was not different from zero; they all died within 35 wk of the end of their study. Seven patients were classified as responders; 5 survived and 2 died, one at 25 wk and the other at 76 wk. In the retrospective study, a decrease of 0.5 SUV between studies performed at 1 and 3 wk after the initiation of chemotherapy was predictive of those patients who survived >6 mo and in whom chemotherapy was presumably successful. CONCLUSION: Patients with non-small cell lung cancer who had a positive outcome, as exhibited by prolonged survival, were those who showed a tumor metabolic response assessed using weekly (18)F-FDG PET studies. (18)F-FDG PET studies performed at 1 and 3 wk after the initiation of chemotherapy allowed prediction of the response to therapy.


Asunto(s)
Antineoplásicos/administración & dosificación , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/tratamiento farmacológico , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Carboplatino/administración & dosificación , Docetaxel , Femenino , Humanos , Masculino , Pronóstico , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Taxoides/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
18.
J Oral Maxillofac Surg ; 65(12): 2524-35, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18022480

RESUMEN

PURPOSE: To investigate the role of 18-fluorine-fluorodeoxyglucose positron emission tomography/computerized tomography ((18)F-FDG PET/CT) in the preoperative prediction of the presence and extent of neck disease in patients with oral/head and neck cancer. PATIENTS AND METHODS: Seventy patients were enrolled in the study, 47 of whom had a clinically negative neck (N0), 19 of whom had a clinically positive unilateral neck (N+), and 4 of whom were negative on 1 side of the neck and positive on the other. Each patient underwent a PET/CT study before undergoing selective neck dissection for N0 disease or modified radical neck dissection for N+ disease. Tissues were submitted for histopathologic examination and were oriented for the pathologist as to the oncologic levels so as to permit correlation between histopathologic findings and the imaging results. RESULTS: The sensitivity and specificity of the PET/CT procedure were 79% and 82% for the N0 neck, and 95% and 25% for the N+ neck. One hundred ninety-two (11.4%) of the 1,678 nodes identified at histopathology were positive for metastases. The overall nodal sensitivity and specificity were 48% and 99%, respectively. CONCLUSION: In patients with clinically negative necks, a negative test would not help the surgeon in the management strategy of the patient because of the rate of false-negative results, but a positive test can diagnose metastatic deposits with a high positive predictive value. In patients with clinically positive necks, a positive test will confirm the presence of disease, although false-negative lymph nodes were additionally identified in these clinically positive necks. With respect to nodes, the sensitivity of the imaging procedure is such that the results could not help the surgeon in deciding which level to dissect and which to spare. In the final analysis, the head and neck oncologic surgeon should not depend on the results of the PET/CT scan to determine which patients will benefit from neck dissection. Rather, time-honored principles of neck surgery should be followed, particularly with regard to the liberal execution of prophylactic neck dissections in patients with clinically N0 necks.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias Mandibulares/diagnóstico por imagen , Neoplasias de la Boca/diagnóstico por imagen , Estadificación de Neoplasias/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/patología , Reacciones Falso Negativas , Femenino , Neoplasias de Cabeza y Cuello/patología , Humanos , Metástasis Linfática , Masculino , Neoplasias Mandibulares/patología , Persona de Mediana Edad , Neoplasias de la Boca/patología , Disección del Cuello , Estadificación de Neoplasias/instrumentación , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Neoplasias de la Lengua/diagnóstico por imagen , Neoplasias de la Lengua/patología
19.
Nucl Med Commun ; 38(11): 971-978, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28885539

RESUMEN

PURPOSE: PET/computed tomography (CT) has been shown to detect lesions in patients with pulmonary tuberculosis (PTB) and may be useful for assessing PTB disease in clinical research studies. However, radiation dose is of concern for clinical research in individuals with an underlying curable disease. This study aimed to determine whether PET/MR is equivalent to PET/CT in PTB. MATERIALS AND METHODS: Ten patients with microbiologically confirmed PTB were recruited. Patients received 129.0±4.1 MBq of fluorine-18-fluorodeoxyglucose. Five of the 10 patients underwent a PET/MR scan, followed by PET/CT. The remaining five were first imaged on the PET/CT, followed by the PET/MRI. PET acquisition began at 66.7±14.4 min (mean±SD) after injection when performing PET/MR first (PET/CT: 117.2±5.6 min) and 92.4±7.6 min when patients were imaged on PET/MR second (PET/CT: 61.1±3.9 min). PET data were reconstructed iteratively with Ordinary-Poisson Ordered-Subset Expectation-Maximization and reconstruction parameters were matched across the two scanners. A visual lesion detection task and a standardized uptake value (SUV) analysis were carried out. The CT Hounsfield unit values of PTB lesions were also compared with MR-based attenuation correction mu-map tissue classes. RESULTS: A total of 108 PTB lesions were detected on PET/MR and 112 on PET/CT. SUV analysis was carried out on 50 of these lesions that were observed with both modalities. Mean standardized uptake value (SUVmean) and maximum standardized uptake value (SUVmax) were significantly lower on PET/MR (SUVmean: 2.6±1.4; SUVmax: 4.3±2.5) than PET/CT (SUVmean: 3.5±1.5; SUVmax: 5.3±2.4). CONCLUSION: PET/MR visual performance was shown to be comparable to PET/CT in terms of the number of PTB lesions detected. SUVs were significantly lower on PET/MR. Dixon-based attenuation correction underestimates the linear attenuation coefficient of PTB lesions, resulting in lower SUVs compared with PET/CT. However, the use of PET/MR to measure the response of lung lesions to assess response to treatment in research studies is unlikely to be affected by these differences in quantification.


Asunto(s)
Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tuberculosis Pulmonar/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
20.
J Nucl Med ; 58(3): 399-405, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27688481

RESUMEN

Lung cancer remains responsible for more deaths worldwide than any other cancer, but recently there has been a significant shift in the clinical paradigm regarding the initial management of subjects at high risk for this disease. Low-dose CT has demonstrated significant improvements over planar x-ray screening for patient prognoses and is now performed in the United States. Specificity of this modality, however, is poor, and the additional information from PET has the potential to improve its accuracy. Routine screening requires consideration of the effective dose delivered to the patient, and this work investigates image quality of PET for low-dose conditions, in the context of lung lesion detectability. Reduced radiotracer doses were simulated by randomly discarding counts from clinical lung cancer scans acquired in list-mode. Bias and reproducibility of lesion activity values were relatively stable even at low total counts of around 5 million trues. Additionally, numeric observer models were developed and trained with the results of 2 physicians and 3 postdoctoral researchers with PET experience in a detection task; detection sensitivity of the observers was well correlated with lesion signal-to-noise ratio. The models were used prospectively to survey detectability of lung cancer lesions, and the findings suggested a lower limit around 10 million true counts for maximizing performance. Under the acquisition parameters used in this study, this translates to an effective patient dose of less than 0.4 mSv, potentially allowing a complete low-dose PET/CT lung screening scan to be obtained under 1 mSv.


Asunto(s)
Detección Precoz del Cáncer/métodos , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Exposición a la Radiación/análisis , Protección Radiológica/métodos , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA