Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Opt Lett ; 47(8): 1945-1948, 2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35427307

RESUMEN

Propagation-based phase-contrast x-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the x-ray attenuation  ß and refraction  δ, components of the complex refractive index of distinct materials within an unknown sample. The method involves curve fitting an error-function-based model to a phase-retrieved interface in a PB-PCXI tomographic reconstruction, which is obtained when Paganin-type phase retrieval is applied with incorrect values of δ and ß. The fit parameters can then be used to calculate true δ and ß values for composite materials. This approach requires no a priori sample information, making it broadly applicable. Our PB-PCXI reconstruction is single-distance, requiring only one exposure per tomographic angle, which is important for radiosensitive samples. We apply this approach to a breast-tissue sample, recovering the refraction component  Î´, with 0.6-2.4% accuracy compared with theoretical values.


Asunto(s)
Tomografía Computarizada por Rayos X , Tomografía , Algoritmos , Imagenología Tridimensional , Tomografía Computarizada por Rayos X/métodos , Rayos X
2.
J Periodontal Res ; 51(1): 112-24, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26094874

RESUMEN

BACKGROUND AND OBJECTIVE: In the present study, the early stages of in vitro bone formation in collagenated porcine scaffolds cultured with human periodontal ligament cells were investigated. The comparison between the osteogenic potential of this structure in basal and differentiating culture media was explored to predict the mechanism of its biological behavior as graft in human defect. Results were validated by synchrotron radiation X-Ray phase contrast computed microtomography (micro-CT). As the periodontal disease plays a key role in systemic and oral diseases, it is crucial to find advanced therapeutic clinical interventions to repair periodontal defects. This has been recently explored using cells and tissues developed in vitro that should ideally be immunologically, functionally, structurally and mechanically identical to the native tissue. MATERIAL AND METHODS: In vitro cultures of human periodontal ligament cells, easily obtained by scraping of alveolar crestal and horizontal fibers of the periodontal ligament, were seeded on to collagenated porcine blocks constituted by natural cancellous and cortical bone. 3D images were obtained by synchrotron radiation micro-CT and processed with a phase-retrieval algorithm based on the transport of intensity equation. RESULTS: Starting from the second week of culture, newly formed mineralized bone was detected in all the scaffolds, both in basal and differentiating media. Bone mineralization was proved to occur preferentially in the trabecular portion and in differentiating media. CONCLUSION: The chosen method, supported by phase contrast micro-CT analysis, successfully and quantitatively monitored the early stages of bone formation and the rate of the bioscaffold resorption in basal and differentiating culture media.


Asunto(s)
Ligamento Periodontal , Proceso Alveolar , Animales , Células Cultivadas , Humanos , Osteogénesis , Células Madre , Porcinos , Sincrotrones
3.
Int J Biol Macromol ; 272(Pt 2): 132883, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38838898

RESUMEN

Glycyrrhiza glabra extract is widely known for its antioxidant and anti-inflammatory properties and can improve the wound healing process. The aim of this work was to shorten the time of the healing process by using an eco-sustainable wound dressing based on Spanish broom flexible cellulosic fabric by impregnation with G. glabra extract-loaded ethosomes. Chemical analysis of G. glabra extract was performed by LC-DAD-MS/MS and its encapsulation into ethosomes was obtained using the ethanol injection method. Lipid vesicles were characterized in terms of size, polydispersity index, entrapment efficiency, zeta potential, and stability. In vitro release studies, biocompatibility, and scratch test on 3T3 fibroblasts were performed. Moreover, the structure of Spanish broom dressing and its ability to absorb wound exudate was characterized by Synchrotron X-ray phase contrast microtomography (SR-PCmicroCT). Ethosomes showed a good entrapment efficiency, nanometric size, good stability over time and a slow release of polyphenols compared to the free extract, and were not cytotoxic. Lastly, the results revealed that Spanish broom wound dressing loaded with G. glabra ethosomes is able to accelerate wound closure by reducing wound healing time. To sum up, Spanish broom wound dressing could be a potential new green tool for biomedical applications.


Asunto(s)
Vendajes , Celulosa , Glycyrrhiza , Extractos Vegetales , Spartium , Cicatrización de Heridas , Animales , Ratones , Glycyrrhiza/química , Extractos Vegetales/química , Extractos Vegetales/farmacología , Cicatrización de Heridas/efectos de los fármacos , Celulosa/química , Celulosa/farmacología , Spartium/química , Células 3T3
4.
Radiol Med ; 118(1): 89-100, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22744351

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the feasibility of phase-contrast mammography with synchrotron radiation using a high-resolution computed radiology (CR) system devoted to mammography. MATERIALS AND METHODS: The study was performed at the Synchrotron Radiation for Medical Physics (SYRMEP) beamline of the Elettra synchrotron radiation (SR) facility in Trieste (Italy); X-ray beams were in the range 16-22 keV with a high degree of monochromaticity and spatial coherence. The CR system evaluated is the FCR Profect CS by Fujifilm Global. The first images were obtained from test objects and surgical breast specimens. Images obtained using SR and both screen-film and the CR system were compared with images of the same samples acquired with digital mammography equipment. In view of the good quality of the results obtained, the CR system was used in two mammographic examinations with SR. RESULTS: Images acquired using SR and both screen-film and CR were obtained with the same level of delivered dose. Image quality obtained with CR was similar or superior to that of screen-film images. Moreover, the digital images obtained with SR were always better than those acquired using the digital mammography system. CONCLUSIONS: Phase-contrast mammography with SR using the studied CR system is a feasible option.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Sincrotrones , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Estudios de Factibilidad , Femenino , Humanos , Mastectomía , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador
5.
Phys Med ; 112: 102640, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37441823

RESUMEN

Phase-contrast imaging techniques address the issue of poor soft-tissue contrast encountered in traditional X-ray imaging. This can be accomplished with the propagation-based phase-contrast technique by employing a coherent photon beam, which is available at synchrotron facilities, as well as long sample-to-detector distances. This study demonstrates the optimization of propagation-based phase-contrast computed tomography (CT) techniques for multiscale X-ray imaging of the breast at the Elettra synchrotron facility (Trieste, Italy). Two whole breast mastectomy samples were acquired with propagation-based breast-CT using a monochromatic synchrotron beam at a pixel size of 60 µm. Paraffin-embedded blocks sampled from the same tissues were scanned with propagation-based micro-CT imaging using a polychromatic synchrotron beam at a pixel size of 4 µm. Images of both methodologies and of the same sample were spatially registered. The resulting images showed the transition from whole breast imaging with propagation-based breast-CT methodology to virtual histology with propagation-based micro-CT imaging of the same sample. Additionally, conventional histological images were matched to virtual histology images. Phase-contrast images offer a high resolution with low noise, which allows for a highly precise match between virtual and conventional histology. Furthermore, those techniques allow a clear discernment of breast structures, lesions, and microcalcifications, being a promising clinically-compatible tool for breast imaging in a multiscale approach, to either assist in the detection of cancer in full volume breast samples or to complement structure identification in paraffin-embedded breast tissue samples.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Microtomografía por Rayos X , Rayos X , Neoplasias de la Mama/diagnóstico por imagen , Mastectomía , Mama/diagnóstico por imagen
6.
Med Phys ; 39(9): 5621-34, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22957628

RESUMEN

PURPOSE: This study investigates the image quality of tomosynthesis slices obtained from several acquisition sets with synchrotron radiation using a breast phantom incorporating details that mimic various breast lesions, in a heterogeneous background. METHODS: A complex Breast phantom (MAMMAX) with a heterogeneous background and thickness that corresponds to 4.5 cm compressed breast with an average composition of 50% adipose and 50% glandular tissue was assembled using two commercial phantoms. Projection images using acquisition arcs of 24°, 32°, 40°, 48°, and 56° at incident energy of 17 keV were obtained from the phantom with the synchrotron radiation for medical physics beamline at ELETTRA Synchrotron Light Laboratory. The total mean glandular dose was set equal to 2.5 mGy. Tomograms were reconstructed with simple multiple projection algorithm (MPA) and filtered MPA. In the latter case, a median filter, a sinc filter, and a combination of those two filters were applied on the experimental data prior to MPA reconstruction. Visual inspection, contrast to noise ratio, contrast, and artifact spread function were the figures of merit used in the evaluation of the visualisation and detection of low- and high-contrast breast features, as a function of the reconstruction algorithm and acquisition arc. To study the benefits of using monochromatic beams, single projection images at incident energies ranging from 14 to 27 keV were acquired with the same phantom and weighted to synthesize polychromatic images at a typical incident x-ray spectrum with W target. RESULTS: Filters were optimised to reconstruct features with different attenuation characteristics and dimensions. In the case of 6 mm low-contrast details, improved visual appearance as well as higher contrast to noise ratio and contrast values were observed for the two filtered MPA algorithms that exploit the sinc filter. These features are better visualized at extended arc length, as the acquisition arc of 56° with 15 projection images demonstrates the highest image reconstruction quality. For microcalcifications, filtered MPA implemented with a combination of median and sinc filters indicates better feature appearance due to efficient suppression of background tissue. The image quality of these features is less sensitive to the acquisition arc. Calcifications with size ranging from 170 to 500 µm, like the ones presently studied, are well identified and visualized for all arcs used. The comparison of single projection images obtained under different beam conditions showed that the use of monochromatic beam can produce an image with higher contrast and contrast to noise ratio compared to an image corresponding to a polychromatic beam even when the latter is acquired with double incident exposure. CONCLUSIONS: Filter optimization in respect to the type of feature characteristics is important before the reconstruction. The MPA combined with median and sinc filters results in improved reconstruction of microcalcifications and low-contrast features. The latter are better visualized at extended arc length, while microcalcifications are less sensitive to this acquisition parameter. Use of monochromatic beams may result in tomographic images with higher contrast acquired at lower incident exposures.


Asunto(s)
Mamografía/instrumentación , Sincrotrones , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Control de Calidad
7.
Phys Med Biol ; 67(9)2022 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-35395648

RESUMEN

Objective.To introduce the optimization of a customized GPU-based simultaneous algebraic reconstruction technique (cSART) in the field of phase-contrast breast computed tomography (bCT). The presented algorithm features a 3D bilateral regularization filter that can be tuned to yield optimal performance for clinical image visualization and tissues segmentation.Approach.Acquisitions of a dedicated test object and a breast specimen were performed at Elettra, the Italian synchrotron radiation (SR) facility (Trieste, Italy) using a large area CdTe single-photon counting detector. Tomographic images were obtained at 5 mGy of mean glandular dose, with a 32 keV monochromatic x-ray beam in the free-space propagation mode. Three independent algorithms parameters were optimized by using contrast-to-noise ratio (CNR), spatial resolution, and noise texture metrics. The results obtained with the cSART algorithm were compared with conventional SART and filtered back projection (FBP) reconstructions. Image segmentation was performed both with gray scale-based and supervised machine-learning approaches.Main results.Compared to conventional FBP reconstructions, results indicate that the proposed algorithm can yield images with a higher CNR (by 35% or more), retaining a high spatial resolution while preserving their textural properties. Alternatively, at the cost of an increased image 'patchiness', the cSART can be tuned to achieve a high-quality tissue segmentation, suggesting the possibility of performing an accurate glandularity estimation potentially of use in the realization of realistic 3D breast models starting from low radiation dose images.Significance.The study indicates that dedicated iterative reconstruction techniques could provide significant advantages in phase-contrast bCT imaging. The proposed algorithm offers great flexibility in terms of image reconstruction optimization, either toward diagnostic evaluation or image segmentation.


Asunto(s)
Compuestos de Cadmio , Puntos Cuánticos , Algoritmos , Telurio , Tomografía Computarizada por Rayos X/métodos
8.
Med Phys ; 37(4): 1893-903, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20443511

RESUMEN

PURPOSE: In this article, the image quality of reconstructed volumes by four algorithms for digital tomosynthesis, applied in the case of breast, is investigated using synchrotron radiation. METHODS: An angular data set of 21 images of a complex phantom with heterogeneous tissue-mimicking background was obtained using the SYRMEP beamline at ELETTRA Synchrotron Light Laboratory, Trieste, Italy. The irradiated part was reconstructed using the multiple projection algorithm (MPA) and the filtered backprojection with ramp followed by hamming windows (FBR-RH) and filtered backprojection with ramp (FBP-R). Additionally, an algorithm for reducing the noise in reconstructed planes based on noise mask subtraction from the planes of the originally reconstructed volume using MPA (MPA-NM) has been further developed. The reconstruction techniques were evaluated in terms of calculations and comparison of the contrast-to-noise ratio (CNR) and artifact spread function. RESULTS: It was found that the MPA-NM resulted in higher CNR, comparable with the CNR of FBP-RH for high contrast details. Low contrast objects are well visualized and characterized by high CNR using the simple MPA and the MPA-NM. In addition, the image quality of the reconstructed features in terms of CNR and visual appearance as a function of the initial number of projection images and the reconstruction arc was carried out. Slices reconstructed with more input projection images result in less reconstruction artifacts and higher detail CNR, while those reconstructed from projection images acquired in reduced angular range causes pronounced streak artifacts. CONCLUSIONS: Of the reconstruction algorithms implemented, the MPA-NM and MPA are a good choice for detecting low contrast objects, while the FBP-RH, FBP-R, and MPA-NM provide high CNR and well outlined edges in case of microcalcifications.


Asunto(s)
Neoplasias de la Mama/patología , Neoplasias de la Mama/radioterapia , Mama/patología , Sincrotrones , Algoritmos , Artefactos , Medios de Contraste/farmacología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Programas Informáticos , Factores de Tiempo , Tomografía/métodos
9.
Anal Bioanal Chem ; 398(2): 1095-107, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20628874

RESUMEN

Double-pulse laser-induced breakdown spectroscopy (DP-LIBS) was optimized for microspatial analyses of fossil and recent snake vertebrae. As complimentary techniques, solution analysis by inductively coupled plasma mass spectrometry and synchrotron radiation X-ray microtomography was utilized in order to determine the overall concentration of the selected elements in the samples and to visualize nondestructively the fossil sample microstructure, respectively. Elemental mapping of pathological bony tissue by DP-LIBS has been proven as a powerful tool for considering the osteitis deformans phases in fossil vertebrae.


Asunto(s)
Huesos/anatomía & histología , Huesos/patología , Fósiles , Serpientes/anatomía & histología , Análisis Espectral/métodos , Animales , Rayos Láser , Microtomografía por Rayos X/métodos
10.
Sci Rep ; 10(1): 18934, 2020 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-33144603

RESUMEN

Amphibians are models for studying applied ecological issues such as habitat loss, pollution, disease, and global climate change due to their sensitivity and vulnerability to changes in the environment. Developmental series of amphibians are informative about their biology, and X-ray based 3D reconstruction holds promise for quantifying morphological changes during growth-some with a direct impact on the possibility of an experimental investigation on several of the ecological topics listed above. However, 3D resolution and discrimination of their soft tissues have been difficult with traditional X-ray computed tomography, without time-consuming contrast staining. Tomographic data were initially performed (pre-processing and reconstruction) using the open-source software tool SYRMEP Tomo Project. Data processing and analysis of the reconstructed tomography volumes were conducted using the segmentation semi-automatic settings of the software Avizo Fire 8, which provide information about each investigated tissues, organs or bone elements. Hence, volumetric analyses were carried out to quantify the development of structures in different tadpole developmental stages. Our work shows that synchrotron X-ray microtomography using phase-contrast mode resolves the edges of the internal tissues (as well as overall tadpole morphology), facilitating the segmentation of the investigated tissues. Reconstruction algorithms and segmentation software played an important role in the qualitative and quantitative analysis of each target structure of the Thoropa miliaris tadpole at different stages of development, providing information on volume, shape and length. The use of the synchrotron X-ray microtomography setup of the SYRMEP beamline of Elettra Synchrotron, in phase-contrast mode, allows access to volumetric data for bone formation, eye development, nervous system and notochordal changes during the development (ontogeny) of tadpoles of a cycloramphid frog Thoropa miliaris. As key elements in the normal development of these and any other frog tadpole, the application of such a comparative ontogenetic study, may hold interest to researchers in experimental and environmental disciplines.


Asunto(s)
Anuros/crecimiento & desarrollo , Larva/ultraestructura , Microtomografía por Rayos X/veterinaria , Algoritmos , Animales , Procesamiento de Imagen Asistido por Computador , Larva/crecimiento & desarrollo , Sincrotrones
11.
Sci Rep ; 9(1): 13762, 2019 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-31551475

RESUMEN

In this study we demonstrate the first direct comparison between synchrotron x-ray propagation-based CT (PB-CT) and cone-beam breast-CT (CB-CT) on human mastectomy specimens (N = 12) including different benign and malignant lesions. The image quality and diagnostic power of the obtained data sets were compared and judged by two independent expert radiologists. Two cases are presented in detail in this paper including a comparison with the corresponding histological evaluation. Results indicate that with PB-CT it is possible to increase the level of contrast-to-noise ratio (CNR) keeping the same level of dose used for the CB-CT or achieve the same level of CNR reached by CB-CT at a lower level of dose. In other words, PB-CT can achieve a higher diagnostic potential compared to the commercial breast-CT system while also delivering a considerably lower mean glandular dose. Therefore, we believe that PB-CT technique, if translated to a clinical setting, could have a significant impact in improving breast cancer diagnosis.


Asunto(s)
Neoplasias de la Mama/patología , Mama/patología , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada por Rayos X/métodos , Estudios de Factibilidad , Femenino , Humanos , Mastectomía/métodos , Fantasmas de Imagen , Dosis de Radiación , Sincrotrones
12.
Med Phys ; 46(12): 5478-5487, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31574166

RESUMEN

PURPOSE: Propagation-based phase-contrast computed tomography (PB-CT) is a method for three-dimensional x-ray imaging that utilizes refraction, as well as absorption, of x rays in the tissues to increase the signal-to-noise ratio (SNR) in the resultant images, in comparison with equivalent conventional absorption-only x-ray tomography (CT). Importantly, the higher SNR is achieved without sacrificing spatial resolution or increasing the radiation dose delivered to the imaged tissues. The present work has been carried out in the context of the current development of a breast CT imaging facility at the Australian Synchrotron. METHODS: Seven unfixed complete mastectomy samples with and without breast cancer lesions have been imaged using absorption-only CT and PB-CT techniques under controlled experimental conditions. The radiation doses delivered to the mastectomy samples during the scans were comparable to those approved for mammographic screening. Physical characteristics of the reconstructed images, such as spatial resolution and SNR, have been measured and compared with the results of the radiological quality assessment of the complete absorption CT and PB-CT image stacks. RESULTS: Despite the presence of some image artefacts, the PB-CT images have outperformed comparable absorption CT images collected at the same radiation dose, in terms of both the measured objective image characteristics and the radiological image scores. The outcomes of these experiments are shown to be consistent with predictions of the theory of PB-CT imaging and previous reported experimental studies of this imaging modality. CONCLUSIONS: The results presented in this paper demonstrate that PB-CT holds a high potential for improving on the quality and diagnostic value of images obtained using existing medical x-ray technologies, such as mammography and digital breast tomosynthesis (DBT). If implemented at suitable synchrotron imaging facilities, PB-CT can be used to complement existing imaging modalities, leading to more accurate breast cancer diagnosis.


Asunto(s)
Mastectomía , Sincrotrones , Tomografía Computarizada por Rayos X/instrumentación , Mama/diagnóstico por imagen , Mama/cirugía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador
13.
Mol Imaging Biol ; 20(5): 732-741, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29968183

RESUMEN

Histology and immunohistochemistry of thin tissue sections have been the standard diagnostic procedure in many diseases for decades. This method is highly specific for particular tissue regions or cells, but mechanical sectioning of the specimens is required, which destroys the sample in the process and can lead to non-uniform tissue deformations. In addition, regions of interest cannot be located beforehand and the analysis is intrinsically two-dimensional. Micro X-ray computed tomography (µCT) on the other hand can provide 3D images at high resolution and allows for quantification of tissue structures, as well as the localization of small regions of interest. These advantages advocate the use of µCT for virtual histology tool with or without subsequent classical histology. This review summarizes the most recent examples of virtual histology and provides currently known possibilities of improving contrast and resolution of µCT. Following a background in µCT imaging, ex vivo staining procedures for contrast enhancement are presented as well as label-free virtual histology approaches and the technologies, which could rapidly advance it, such as phase-contrast CT. Novel approaches such as zoom tomography and nanoparticulate contrast agents will also be considered. The current evidence suggests that virtual histology may present a valuable addition to the workflow of histological analysis, potentially reducing the workload in pathology, refining tissue classification, and supporting the detection of small malignancies.


Asunto(s)
Histología , Imagenología Tridimensional , Interfaz Usuario-Computador , Animales , Humanos , Nanopartículas/química , Coloración y Etiquetado , Rayos X
14.
J Tissue Eng Regen Med ; 12(3): 750-761, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28593731

RESUMEN

Bone repair/regeneration is usually investigated through X-ray computed microtomography (µCT) supported by histology of extracted samples, to analyse biomaterial structure and new bone formation processes. Magnetic resonance imaging (µMRI) shows a richer tissue contrast than µCT, despite at lower resolution, and could be combined with µCT in the perspective of conducting non-destructive 3D investigations of bone. A pipeline designed to combine µMRI and µCT images of bone samples is here described and applied on samples of extracted human jawbone core following bone graft. We optimized the coregistration procedure between µCT and µMRI images to avoid bias due to the different resolutions and contrasts. Furthermore, we used an Adaptive Multivariate Clustering, grouping homologous voxels in the coregistered images, to visualize different tissue types within a fused 3D metastructure. The tissue grouping matched the 2D histology applied only on 1 slice, thus extending the histology labelling in 3D. Specifically, in all samples, we could separate and map 2 types of regenerated bone, calcified tissue, soft tissues, and/or fat and marrow space. Remarkably, µMRI and µCT alone were not able to separate the 2 types of regenerated bone. Finally, we computed volumes of each tissue in the 3D metastructures, which might be exploited by quantitative simulation. The 3D metastructure obtained through our pipeline represents a first step to bridge the gap between the quality of information obtained from 2D optical microscopy and the 3D mapping of the bone tissue heterogeneity and could allow researchers and clinicians to non-destructively characterize and follow-up bone regeneration.


Asunto(s)
Regeneración Ósea/fisiología , Huesos/diagnóstico por imagen , Huesos/fisiología , Imagenología Tridimensional , Imagen por Resonancia Magnética , Microtomografía por Rayos X , Anciano , Calcificación Fisiológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Osteogénesis
15.
Microsc Res Tech ; 70(2): 147-53, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17131357

RESUMEN

This article reports on the utilization of X-ray microradiography and laser induced breakdown spectroscopy (LIBS) techniques for investigation of the metal accumulation in different part of leaf samples. The potential of the LIBS-analysis for finding the proper plant species for phytoremediation is compared with the results of microradiography measurements at the HERCULES source at ENEA, Rome (Italy) and X-ray microradiography experiments at the ELETTRA Synchrotron, Trieste (Italy).


Asunto(s)
Cadmio/análisis , Helianthus/química , Rayos Láser , Plomo/análisis , Hojas de la Planta/química , Raíces de Plantas/química , Microrradiografía , Dispersión de Radiación , Análisis Espectral , Sincrotrones/instrumentación , Rayos X
16.
Phys Med Biol ; 52(14): 4171-87, 2007 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-17664601

RESUMEN

Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (<100 microm), whilst quantitative phase and attenuation information can be extracted using just two images when the approximations of geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/métodos , Óptica y Fotónica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Sci Rep ; 7(1): 2858, 2017 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-28588216

RESUMEN

Correlative approaches are a powerful tool in the investigation of biological samples, but require specific preparation procedures to maintain the strength of the employed methods. Here we report the optimization of the embedding protocol of nervous system samples for a correlative synchrotron X-ray computed microtomography (micro-CT) and transmission electron microscopy (TEM) approach. We demonstrate that it is possible to locate, with the micrometric resolution of micro-CT, specific volumes of interest for a further ultrastructural characterization to be performed with TEM. This approach can be applied to samples of different size and morphology up to several cm. Our optimized method represents an invaluable tool for investigating those pathologies in which microscopic alterations are localized in few confined regions, rather than diffused in entire tissues, organs or systems. We present a proof of concept of our method in a mouse model of Globoid Cells Leukodistrophy.


Asunto(s)
Microscopía Electrónica de Transmisión , Sistema Nervioso/diagnóstico por imagen , Sistema Nervioso/ultraestructura , Microtomografía por Rayos X , Animales , Modelos Animales de Enfermedad , Imagenología Tridimensional , Leucodistrofia de Células Globoides/diagnóstico por imagen , Leucodistrofia de Células Globoides/patología , Ratones , Sistema Nervioso/patología , Ratas , Médula Espinal/diagnóstico por imagen , Médula Espinal/patología , Médula Espinal/ultraestructura , Microtomografía por Rayos X/métodos
18.
Phys Med Biol ; 62(6): 2315-2332, 2017 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-28140377

RESUMEN

The aim of this study was to optimise the experimental protocol and data analysis for in-vivo breast cancer x-ray imaging. Results are presented of the experiment at the SYRMEP beamline of Elettra Synchrotron using the propagation-based phase-contrast mammographic tomography method, which incorporates not only absorption, but also x-ray phase information. In this study the images of breast tissue samples, of a size corresponding to a full human breast, with radiologically acceptable x-ray doses were obtained, and the degree of improvement of the image quality (from the diagnostic point of view) achievable using propagation-based phase-contrast image acquisition protocols with proper incorporation of x-ray phase retrieval into the reconstruction pipeline was investigated. Parameters such as the x-ray energy, sample-to-detector distance and data processing methods were tested, evaluated and optimized with respect to the estimated diagnostic value using a mastectomy sample with a malignant lesion. The results of quantitative evaluation of images were obtained by means of radiological assessment carried out by 13 experienced specialists. A comparative analysis was performed between the x-ray and the histological images of the specimen. The results of the analysis indicate that, within the investigated range of parameters, both the objective image quality characteristics and the subjective radiological scores of propagation-based phase-contrast images of breast tissues monotonically increase with the strength of phase contrast which in turn is directly proportional to the product of the radiation wavelength and the sample-to-detector distance. The outcomes of this study serve to define the practical imaging conditions and the CT reconstruction procedures appropriate for low-dose phase-contrast mammographic imaging of live patients at specially designed synchrotron beamlines.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Tomografía por Rayos X/métodos , Femenino , Humanos , Mamografía/normas , Tomografía por Rayos X/normas , Rayos X
19.
Med Phys ; 43(1): 583, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26745950

RESUMEN

PURPOSE: This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18-46.5 keV. METHODS: Pieces of XR-QA2 films were irradiated, in a plane transverse to the beam axis, with a monochromatic beam of energy in the range 18-40 keV at the ELETTRA synchrotron radiation facility (Trieste, Italy) and with a polychromatic beam from a laboratory x-ray tube operated at 80, 100, and 120 kV. The film calibration curve was expressed as air kerma (measured free-in-air with an ionization chamber) versus the net optical reflectance change (netΔR) derived from the red channel of the RGB scanned film image. Four functional relationships (rational, linear exponential, power, and logarithm) were tested to evaluate the best curve for fitting the calibration data. The adequacy of the various fitting functions was tested by using the uncertainty analysis and by assessing the average of the absolute air kerma error calculated as the difference between calculated and delivered air kerma. The sensitivity of the film was evaluated as the ratio of the change in net reflectance to the corresponding air kerma. RESULTS: The sensitivity of XR-QA2 films increased in the energy range 18-39 keV, with a maximum variation of about 170%, and decreased in the energy range 38-46.5 keV. The present results confirmed and extended previous findings by this and other groups, as regards the dose response of the radiochromic film XR-QA2 to monochromatic and polychromatic x-ray beams, respectively. CONCLUSIONS: The XR-QA2 radiochromic film response showed a strong dependence on beam energy for both monochromatic and polychromatic beams in the range of half value layer values from 0.55 to 6.1 mm Al and corresponding effective energies from 18 to 46.5 keV. In this range, the film response varied by 170%, from a minimum sensitivity of 0.0127 to a maximum sensitivity of 0.0219 at 10 mGy air kerma in air. The more suitable function for air kerma calibration of the XR-QA2 radiochromic film was the power function. A significant batch-to-batch variation, up to 55%, in film response at 120 kV (46.5 keV effective energy) was observed in comparison with published data.


Asunto(s)
Dosimetría por Película/métodos , Calibración , Rayos X
20.
Phys Med Biol ; 61(2): 569-87, 2016 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-26683710

RESUMEN

The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy). A Geant4 Monte Carlo code was implemented, simulating the photon irradiation from a synchrotron radiation source in the energetic range from 8 to 50 keV with 1 keV intervals, to evaluate the MGD. The code was validated with literature data, in terms of mammographic normalized glandular dose coefficients (DgN) and with ad hoc experimental data, in terms of computed tomography dose index (CTDI). Simulated cylindrical phantoms of different sizes (diameter at phantom base 8, 10, 12, 14 or 16 cm, axial length 1.5 times the radius) and glandular fraction by weight (0%, 14.3%, 25%, 50%, 75% and 100%) were implemented into the code. The validation of the code shows an excellent agreement both with previously published work and in terms of DgN and CDTI measurements. The implemented simulations show a dependence of the glandular dose estimate on the vertical dimension of the irradiated zone when a partial organ irradiation was implemented. Specific normalized coefficients for calculating the MGD to the whole breast or to the single irradiated slice were reported.


Asunto(s)
Neoplasias de la Mama/radioterapia , Glándulas Mamarias Humanas/efectos de la radiación , Fotones , Planificación de la Radioterapia Asistida por Computador/métodos , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Fantasmas de Imagen , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA