Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Infect Dis ; 210(7): 1052-61, 2014 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-24719474

RESUMEN

BACKGROUND: We report the first-in-human safety and immunogenicity assessment of a prototype hexon chimeric adenovirus (Ad) serotype 5 (Ad5) vector containing the hexon hypervariable regions of Ad serotype 48 (Ad48) and expressing human immunodeficiency virus (HIV) type 1 EnvA. METHODS: Forty-eight Ad5 and Ad48 seronegative, HIV-uninfected subjects were enrolled in a randomized, double-blind, placebo-controlled, dose escalation phase 1 study. Four groups of 12 subjects received 10(9) to 10(11) viral particles (vp) of the Ad5HVR48.EnvA.01 vaccine (n = 10 per group) or placebo (n = 2 per group) at week 0 or weeks 0, 4, and 24. Safety and immunogenicity were assessed. RESULTS: Self-limited reactogenicity was observed after the initial immunization in the highest (10(11) vp) dose group. Responses in vaccinees included Ad48 neutralizing antibody (nAb) titers higher than Ad5 nAb titers, EnvA-specific enzyme-linked immunosorbent assay titers, and EnvA-specific enzyme-linked immunospot assay responses, and these responses generally persisted at week 52. At week 28 in the 10(9), 10(10), and 10(11) vp 3-dose groups, geometric mean EnvA enzyme-linked immunosorbent assay titers were 5721, 10 929, and 3420, respectively, and Ad48 nAb titers were a median of 1.7-fold higher than for Ad5. CONCLUSIONS: Ad5HVR48.ENVA.01 was safe, well tolerated, and immunogenic at all doses tested. Vector-elicited nAb responses were greater for Ad48 than Ad5, confirming that Ad-specific nAbs in humans are primarily, but not exclusively, directed against the hexon hypervariable regions. Clinical Trials Registration. NCT00695877.


Asunto(s)
Vacunas contra el SIDA/efectos adversos , Vacunas contra el SIDA/inmunología , Adenovirus Humanos/genética , Proteínas de la Cápside/genética , Expresión Génica , VIH-1/genética , Productos del Gen env del Virus de la Inmunodeficiencia Humana/genética , Vacunas contra el SIDA/administración & dosificación , Vacunas contra el SIDA/genética , Adolescente , Adulto , Anticuerpos Neutralizantes/sangre , Método Doble Ciego , Portadores de Fármacos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/epidemiología , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/patología , Ensayo de Inmunoadsorción Enzimática , Ensayo de Immunospot Ligado a Enzimas , Femenino , Vectores Genéticos , Anticuerpos Anti-VIH/sangre , Humanos , Leucocitos Mononucleares/inmunología , Masculino , Persona de Mediana Edad , Placebos/administración & dosificación , Vacunas Sintéticas/administración & dosificación , Vacunas Sintéticas/efectos adversos , Vacunas Sintéticas/genética , Vacunas Sintéticas/inmunología , Adulto Joven
2.
J Infect Dis ; 207(2): 240-7, 2013 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-23125444

RESUMEN

BACKGROUND: We report the first-in-human safety and immunogenicity assessment of a prototype Ad26 vector-based human immunodeficiency virus (HIV) vaccine in humans. METHODS: Sixty Ad26-seronegative, healthy, HIV-uninfected subjects were enrolled in a randomized, double-blinded, placebo-controlled, dose-escalation phase 1 study. Five groups of 12 subjects received 10(9)-10(11) vp of the Ad26-EnvA vaccine (N = 10/group) or placebo (N = 2/group) at weeks 0 and 24 or weeks 0, 4, and 24. Safety and immunogenicity were assessed. RESULTS: Self-limited reactogenicity was observed after the initial immunization at the highest (10(11) vp) dose. No product-related SAEs were observed. All subjects who received the Ad26-EnvA vaccine developed Ad26 NAb titers, EnvA-specific enzyme-linked immunosorbent assays (ELISA) titers, and EnvA-specific enzyme-linked immunospot assays (ELISPOT) responses. These responses persisted at week 52. At week 28 in the 10(9), 10(10), 10(11) vp 3-dose and the 10(10) and 5 × 10(10) vp 2-dose groups, geometric mean EnvA ELISA titers were 6113, 12 470, 8545, 3470, and 9655 and mean EnvA ELISPOT responses were 397, 178, 736, 196, and 1311 SFC/10(6) peripheral blood mononuclear cells, respectively. CONCLUSION: This Ad26 vectored vaccine was generally safe and immunogenic at all doses tested. Reactogenicity was minimal with doses of 5 × 10(10) vp or less. Ad26 is a promising new vaccine vector for HIV-1. CLINICAL TRIALS REGISTRATION: NCT00618605.


Asunto(s)
Vacunas contra el SIDA/efectos adversos , Vacunas contra el SIDA/inmunología , Adenovirus Humanos/genética , Productos del Gen env/inmunología , Infecciones por VIH/prevención & control , VIH-1/inmunología , Vacunas contra el SIDA/administración & dosificación , Adenovirus Humanos/clasificación , Método Doble Ciego , Femenino , Productos del Gen env/genética , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/inmunología , Humanos , Leucocitos Mononucleares/inmunología , Masculino , Resultado del Tratamiento , Vacunas Sintéticas/administración & dosificación , Vacunas Sintéticas/efectos adversos , Vacunas Sintéticas/inmunología
3.
Infect Control Hosp Epidemiol ; 43(12): 1942-1944, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34530944

RESUMEN

We assessed the extent to which healthcare workers report more favorable hand hygiene rates when observing members of their own professional group versus other groups' observations of them. Healthcare workers consistently reported higher compliance rates for their own group compared to others' observations of them (97 vs 92%; P ≤ .001).


Asunto(s)
Infección Hospitalaria , Higiene de las Manos , Humanos , Adhesión a Directriz , Personal de Salud , Sesgo , Hospitales , Desinfección de las Manos , Infección Hospitalaria/prevención & control , Control de Infecciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA