Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Electrocardiol ; 76: 66-70, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36442389

RESUMEN

Deterioration of atrial fibrillation into ventricular fibrillation has frequently been described in patients with pre-excitation of the ventricles. We report two cases of atrial fibrillation without pre-excitation leading to rapid ventricular tachycardias and recurrent implantable cardioverter defibrillator therapy in young idiopathic ventricular fibrillation patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Ventricular , Humanos , Nodo Atrioventricular/cirugía , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Electrocardiografía
2.
Europace ; 23(6): 887-897, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33582797

RESUMEN

AIMS: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. METHODS AND RESULTS: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. CONCLUSION: Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.


Asunto(s)
Desfibriladores Implantables , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Estudios de Cohortes , Muerte Súbita Cardíaca/prevención & control , Humanos , Prevención Primaria , Factores de Riesgo
3.
Eur Heart J ; 41(36): 3437-3447, 2020 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-32372094

RESUMEN

AIMS: The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter-Defibrillators (EU-CERT-ICD), a prospective investigator-initiated, controlled cohort study, was conducted in 44 centres and 15 European countries. It aimed to assess current clinical effectiveness of primary prevention ICD therapy. METHODS AND RESULTS: We recruited 2327 patients with ischaemic cardiomyopathy (ICM) or dilated cardiomyopathy (DCM) and guideline indications for prophylactic ICD implantation. Primary endpoint was all-cause mortality. Clinical characteristics, medications, resting, and 12-lead Holter electrocardiograms (ECGs) were documented at enrolment baseline. Baseline and follow-up (FU) data from 2247 patients were analysable, 1516 patients before first ICD implantation (ICD group) and 731 patients without ICD serving as controls. Multivariable models and propensity scoring for adjustment were used to compare the two groups for mortality. During mean FU of 2.4 ± 1.1 years, 342 deaths occurred (6.3%/years annualized mortality, 5.6%/years in the ICD group vs. 9.2%/years in controls), favouring ICD treatment [unadjusted hazard ratio (HR) 0.682, 95% confidence interval (CI) 0.537-0.865, P = 0.0016]. Multivariable mortality predictors included age, left ventricular ejection fraction (LVEF), New York Heart Association class

Asunto(s)
Desfibriladores Implantables , Anciano , Estudios de Cohortes , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Europa (Continente) , Humanos , Prevención Primaria , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
4.
Europace ; 20(6): 963-970, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29016784

RESUMEN

Aims: Therapy with an implantable cardioverter defibrillator (ICD) is established for the prevention of sudden cardiac death (SCD) in high risk patients. We aimed to determine the effectiveness of primary prevention ICD therapy by analysing registry data from 14 centres in 11 European countries compiled between 2002 and 2014, with emphasis on outcomes in women who have been underrepresented in all trials. Methods and results: Retrospective data of 14 local registries of primary prevention ICD implantations between 2002 and 2014 were compiled in a central database. Predefined primary outcome measures were overall mortality and first appropriate and first inappropriate shocks. A multivariable model enforcing a common hazard ratio for sex category across the centres, but allowing for centre-specific baseline hazards and centre specific effects of other covariates, was adjusted for age, the presence of ischaemic cardiomyopathy or a CRT-D, and left ventricular ejection fraction ≤25%. Of the 5033 patients, 957 (19%) were women. During a median follow-up of 33 months (IQR 16-55 months) 129 women (13%) and 807 men (20%) died (HR 0.65; 95% CI: [0.53, 0.79], P-value < 0.0001). An appropriate ICD shock occurred in 66 women (8%) and 514 men (14%; HR 0.61; 95% CI: 0.47-0.79; P = 0.0002). Conclusion: Our retrospective analysis of 14 local registries in 11 European countries demonstrates that fewer women than men undergo ICD implantation for primary prevention. After multivariate adjustment, women have a significantly lower mortality and receive fewer appropriate ICD shocks.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica , Factores Sexuales , Anciano , Arritmias Cardíacas/complicaciones , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/métodos , Falla de Equipo/estadística & datos numéricos , Europa (Continente)/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Prevención Primaria/métodos , Sistema de Registros/estadística & datos numéricos , Estudios Retrospectivos
5.
Pacing Clin Electrophysiol ; 40(7): 873-882, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28543106

RESUMEN

BACKGROUND: Previous reports suggest that biventricular pacing (BiVp) fused with intrinsic conduction (BiVp-fusion, triple wavefront fusion) is associated with improved resynchronization compared to pure-BiVp in cardiac resynchronization therapy (CRT). This study aimed to assess the association between acute hemodynamic benefit of CRT and signs of BiVp-fusion by using a novel electrogram (EGM)-based method. METHODS: In 17 patients undergoing CRT implantation, 28 combinations of atrioventricular (AV) and interventricular (VV) delays were applied while invasively measuring acute hemodynamic response based on maximum rate of left ventricular (LV) pressure rise (LV dP/dtmax ) to assess optimal BiVp settings. BiVp-fusion was noted if farfield signal (caused by first intrinsic ventricular depolarization) was seen prior to right ventricular (RV) pacing (RVp) artifact on integrated bipolar RV EGM, or QRS morphology changed compared to pure-BiVp (short AV-delay) as seen on electrocardiogram (ECG). RESULTS: Mean optimal RVp timing was at 98 ± 17% of intrinsic right atrial (RA)-RVfarfield (interval from right atrial pace or sense to RV farfield signal) interval, while preactivating the LV at 50 ± 11% of RA-RVsense (interval from right atrial pace or sense to RV sense interval) interval. BiVp-fusion was noted in 16 of 17 (94%) patients on ECG during optimal BiVp. Eight of these patients showed intrinsic farfield signal prior to RVp artifact on RV EGM. In the remaining eight, the RVp was paced just within the RA-RVfarfield interval with a mean of 25 ± 14 ms prior to the onset; therefore, the intrinsic farfield was masked. CONCLUSION: Optimal hemodynamic BiVp facilitates triple wavefront fusion, by pacing the RV around the onset of intrinsic farfield signal on RV EGM, while preactivating the LV. Aiming at BiVp-fusion could be a target for noninvasive EGM-based CRT device setting optimization.


Asunto(s)
Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Insuficiencia Cardíaca/terapia , Hemodinámica/fisiología , Adulto , Anciano , Algoritmos , Terapia de Resincronización Cardíaca/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
Eur Heart J ; 36(7): 425-33, 2015 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-25176942

RESUMEN

AIM: The neural cardiac therapy for heart failure (NECTAR-HF) was a randomized sham-controlled trial designed to evaluate whether a single dose of vagal nerve stimulation (VNS) would attenuate cardiac remodelling, improve cardiac function and increase exercise capacity in symptomatic heart failure patients with severe left ventricular (LV) systolic dysfunction despite guideline recommended medical therapy. METHODS: Patients were randomized in a 2 : 1 ratio to receive therapy (VNS ON) or control (VNS OFF) for a 6-month period. The primary endpoint was the change in LV end systolic diameter (LVESD) at 6 months for control vs. therapy, with secondary endpoints of other echocardiography measurements, exercise capacity, quality-of-life assessments, 24-h Holter, and circulating biomarkers. RESULTS: Of the 96 implanted patients, 87 had paired datasets for the primary endpoint. Change in LVESD from baseline to 6 months was -0.04 ± 0.25 cm in the therapy group compared with -0.08 ± 0.32 cm in the control group (P = 0.60). Additional echocardiographic parameters of LV end diastolic dimension, LV end systolic volume, left ventricular end diastolic volume, LV ejection fraction, peak V02, and N-terminal pro-hormone brain natriuretic peptide failed to show superiority compared to the control group. However, there were statistically significant improvements in quality of life for the Minnesota Living with Heart Failure Questionnaire (P = 0.049), New York Heart Association class (P = 0.032), and the SF-36 Physical Component (P = 0.016) in the therapy group. CONCLUSION: Vagal nerve stimulation as delivered in the NECTAR-HF trial failed to demonstrate a significant effect on primary and secondary endpoint measures of cardiac remodelling and functional capacity in symptomatic heart failure patients, but quality-of-life measures showed significant improvement.


Asunto(s)
Insuficiencia Cardíaca/terapia , Estimulación del Nervio Vago/métodos , Electrocardiografía Ambulatoria , Tolerancia al Ejercicio/fisiología , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Calidad de Vida , Resultado del Tratamiento , Estimulación del Nervio Vago/efectos adversos , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia , Remodelación Ventricular/fisiología
7.
Heart Rhythm O2 ; 4(1): 9-17, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36713038

RESUMEN

Background: Image guidance to assist left ventricular (LV) lead placement may improve outcome after cardiac resynchronization therapy (CRT), but previous approaches and results varied greatly, and multicenter feasibility is lacking altogether. Objective: We sought to investigate the multicenter feasibility of image guidance for periprocedural assistance of LV lead placement for CRT. Methods: In 30 patients from 3 hospitals, cardiac magnetic resonance imaging was performed within 3 months prior to CRT to identify myocardial scar and late mechanical activation (LMA). LMA was determined using radial strain, plotted over time. Segments without scar but clear LMA were classified as optimal for LV lead placement, according to an accurate 36-segment model of the whole heart. LV leads were navigated using image overlay with periprocedural fluoroscopy. After 6 months, volumetric response and super-response were defined as ≥15% or ≥30% reduction in LV end-systolic volume, respectively. Results: Periprocedural image guidance was successfully performed in all CRT patients (age 66 ± 10 years; 59% men, 62% with nonischemic cardiomyopathy, 69% with left bundle branch block). LV leads were placed as follows: within (14%), adjacent (62%), or remote (24%) from the predefined target. According to the conventional 18-segment model, a remote position occurred only once (3%). On average, 86% of patients demonstrated a volumetric response (mean LV end-systolic volume reduction 36 ± 29%), and 66% of all patients were super-responders. Conclusion: On-screen image guidance for LV lead placement in CRT was feasible in a multicenter setting. Efficacy will be further investigated in the randomized controlled ADVISE (Advanced Image Supported Lead Placement in Cardiac Resynchronization Therapy) trial (NCT05053568).

8.
J Cardiovasc Electrophysiol ; 23(11): 1237-45, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22734629

RESUMEN

INTRODUCTION: The aims of this study were to compare ECG signs of biventricular electrical resynchronization during cardiac resynchronization therapy (CRT) with various interventricular (VV) delays and to correlate these and other ECG characteristics with the acute hemodynamic benefit of CRT. METHODS AND RESULTS: Thirty-four patients with heart failure and a left bundle branch block (LBBB) pattern were prospectively enrolled. A 12-lead surface ECG and the relative improvement in left ventricular (LV) dP/dt(max) (the maximum rate of pressure rise) were recorded at baseline and during CRT with VV delays varying from 80 ms LV preactivation to 40 ms right ventricular (RV) preactivation. Rightward QRS-axis shift occurred in 71-80% among all VV delays. Activation reversal to dominant negative in leads I/aVL was progressively observed at increasing LV preactivation (53-65%) and less (18-22%) during RV preactivation. Activation reversal to dominant positive in leads V1/V2 was observed in 21-27% during LV preactivation and in 6-15% during RV preactivation. Higher acute response to CRT was independently predicted by a complete LBBB at baseline (regression coefficient B = 7.7 [0.3-15.0], P = 0.042), later timing of LV depolarization within the QRS at baseline (Q-LVsense: B = 0.2 [0.1-0.3], P = 0.002), and biventricular electrical resynchronization during CRT as evidenced by activation reversal in leads I/aVL (B = 9.9 [3.2-16.6], P = 0.005). CONCLUSION: ECG signs of biventricular electrical resynchronization are present over a wide range of LV preactivated VV delays but to a lesser extent during RV preactivation. The presence of complete LBBB and longer Q-LVsense at baseline and signs of biventricular electrical resynchronization during CRT predict higher acute hemodynamic response.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Electrocardiografía , Insuficiencia Cardíaca/terapia , Hemodinámica , Función Ventricular Izquierda , Función Ventricular Derecha , Potenciales de Acción , Anciano , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Distribución de Chi-Cuadrado , Técnicas Electrofisiológicas Cardíacas , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Presión Ventricular
9.
Europace ; 14(12): 1746-53, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22753868

RESUMEN

AIMS: This study aimed to determine the additional acute haemodynamic effect of atrioventricular (AV) and interventricular (VV) delay optimization compared with current nominal cardiac resynchronization therapy (CRT) device settings, and to explore whether clinical characteristics correlate to the effect of optimization. METHODS AND RESULTS: Fifty CRT patients were prospectively enrolled. The optimal AV and VV delays were guided by relative improvement in maximum rate of left ventricular (LV) pressure rise (%dP/dt(max)). A significant improvement in %dP/dt(max) was obtained by optimization in 23-33% (sensed AV delay), 32-57% (paced AV delay), and 45% of patients (VV delay). Adjustment of the device nominal VV delay from 0 to 40 ms LV pre-activation would diminish the proportion of patients with additional effect of individual optimization from 45 to 15%. Heart failure aetiology [ischaemic 2 ± 2 vs. non-ischaemic 1 ± 1 percentage points (PP) %dP/dt(max), P= 0.013], gender (men 2 ± 2 vs. women 1 ± 1 PP %dP/dt(max), P= 0.012) and intrinsic PR interval (R= 0.49, P= 0.002) correlated to the degree of effect of AV delay optimization. Women yielded more effect of VV delay optimization (4 ± 3 vs. 2 ± 1 PP %dP/dt(max), P= 0.026). CONCLUSION: Compared with the best of the currently available device nominal AV and VV delays, 23-45% of CRT patients can yield additional acute haemodynamic effect by individual optimization of the delays. A new nominal VV delay of 40 ms LV pre-activation is recommended. Male gender, ischaemic aetiology, and longer PR interval are associated with a larger effect of individual optimization.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/prevención & control , Terapia Asistida por Computador/métodos , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/prevención & control , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
10.
Front Cardiovasc Med ; 8: 698336, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34490367

RESUMEN

Aims: The presence of transvenous leads for cardiac device therapy may increase the risk of venous thromboembolisms. The epidemiology of these complications has not yet been determined systematically. Therefore, this study aims to determine (I) the incidence of symptomatic upper extremity deep vein thrombosis (UEDVT) and (II) the prevalence of asymptomatic upper extremity vein occlusion in patients with transvenous leads, both after the initial 2 months following lead implantation. Methods: PubMed, EMBASE, and Cochrane Library were searched until March 31, 2020 to identify studies reporting incidence of UEDVT and prevalence of asymptomatic vein occlusion after the initial 2 months after implantation in adult patients with transvenous leads. Incidence per 100 patient years of follow-up (PY) and proportions (%) were calculated to derive pooled estimates of incidence and prevalence. Results: Search and selection yielded 20 and 24 studies reporting on UEDVT and asymptomatic vein occlusion, respectively. The overall pooled incidence of UEDVT was 0.9 (95% CI 0.5-1.4) per 100PY after 2 months after lead implantation. High statistical heterogeneity was present among studies (I2 = 82.4%; P = < 0.001) and only three studies considered to be at low risk of bias. The overall pooled prevalence of asymptomatic upper extremity vein occlusion was 8.6% (95% CI 6.0-11.5) with high heterogeneity (I2 = 81.4%; P = <0.001). Meta-regression analysis showed more leads to be associated with a higher risk of UEDVT. Conclusion: Transvenous leads are an important risk factor for symptomatic UEDVT, which may occur up to multiple years after initial lead implantation. Existing data on UEDVT after lead implantation is mostly of poor quality, which emphasizes the need for high quality prospective research. Asymptomatic vein occlusion is present in a substantial proportion of patients and may complicate any future lead addition. Clinical Trial Registration: (URL: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42020178136, Identifier: PROSPERO 2020 CRD42020178136).

11.
J Am Heart Assoc ; 10(7): e018063, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33787324

RESUMEN

Background One third of primary prevention implantable cardioverter-defibrillator patients receive appropriate therapy, but all remain at risk of defibrillator complications. Information on these complications in contemporary cohorts is limited. This study assessed complications and their risk factors after defibrillator implantation in a Dutch nationwide prospective registry cohort and forecasts the potential reduction in complications under distinct scenarios of updated indication criteria. Methods and Results Complications in a prospective multicenter registry cohort of 1442 primary implantable cardioverter-defibrillator implant patients were classified as major or minor. The potential for reducing complications was derived from a newly developed prediction model of appropriate therapy to identify patients with a low probability of benefitting from the implantable cardioverter-defibrillator. During a follow-up of 2.2 years (interquartile range, 2.0-2.6 years), 228 complications occurred in 195 patients (13.6%), with 113 patients (7.8%) experiencing at least one major complication. Most common ones were lead related (n=93) and infection (n=18). Minor complications occurred in 6.8% of patients, with lead-related (n=47) and pocket-related (n=40) complications as the most prevailing ones. A surgical reintervention or additional hospitalization was required in 53% or 61% of complications, respectively. Complications were strongly associated with device type. Application of stricter implant indication results in a comparable proportional reduction of (major) complications. Conclusions One in 13 patients experiences at least one major implantable cardioverter-defibrillator-related complication, and many patients undergo a surgical reintervention. Complications are related to defibrillator implantations, and these should be discussed with the patient. Stricter implant indication criteria and careful selection of device type implanted may have significant clinical and financial benefits.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica , Complicaciones Posoperatorias , Implantación de Prótesis/efectos adversos , Anciano , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/clasificación , Desfibriladores Implantables/estadística & datos numéricos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/métodos , Análisis de Falla de Equipo/métodos , Análisis de Falla de Equipo/estadística & datos numéricos , Femenino , Humanos , Masculino , Evaluación de Necesidades , Países Bajos/epidemiología , Selección de Paciente , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Sistema de Registros/estadística & datos numéricos , Reoperación/estadística & datos numéricos , Medición de Riesgo , Factores de Riesgo
12.
J Am Heart Assoc ; 9(23): e018133, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33215550

RESUMEN

Background Short-term variability of the QT interval (STVQT) has been proposed as a novel electrophysiological marker for the prediction of imminent ventricular arrhythmias in animal models. Our aim is to study whether STVQT can predict imminent ventricular arrhythmias in patients. Methods and Results In 2331 patients with primary prophylactic implantable cardioverter defibrillators, 24-hour ECG Holter recordings were obtained as part of the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter Defibrillators) study. ECG Holter recordings showing ventricular arrhythmias of >4 consecutive complexes were selected for the arrhythmic groups (n=170), whereas a control group was randomly selected from the remaining Holter recordings (n=37). STVQT was determined from 31 beats with fiducial segment averaging and calculated as [Formula: see text], where Dn represents the QT interval. STVQT was determined before the ventricular arrhythmia or 8:00 am in the control group and between 1:30 and 4:30 am as baseline. STVQT at baseline was 0.84±0.47 ms and increased to 1.18±0.74 ms (P<0.05) before the ventricular arrhythmia, whereas the STVQT in the control group remained unchanged. The arrhythmic patients were divided into three groups based on the severity of the arrhythmia: (1) nonsustained ventricular arrhythmia (n=32), (2) nonsustained ventricular tachycardia (n=134), (3) sustained ventricular tachycardia (n=4). STVQT increased before nonsustained ventricular arrhythmia, nonsustained ventricular tachycardia, and sustained ventricular tachycardia from 0.80±0.43 ms to 1.18±0.78 ms (P<0.05), from 0.90±0.49 ms to 1.14±0.70 ms (P<0.05), and from 1.05±0.22 ms to 2.33±1.25 ms (P<0.05). This rise in STVQT was significantly higher in sustained ventricular tachycardia compared with nonsustained ventricular arrhythmia (+1.28±1.05 ms versus +0.24±0.57 ms [P<0.05]) and compared with nonsustained ventricular arrhythmia (+0.34±0.87 ms [P<0.05]). Conclusions STVQT increases before imminent ventricular arrhythmias in patients, and the extent of the increase is associated with the severity of the ventricular arrhythmia.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Desfibriladores Implantables , Anciano , Arritmias Cardíacas/prevención & control , Estudios de Cohortes , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía Ambulatoria , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Factores de Tiempo
13.
BMJ Open Sci ; 3(1): e000006, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-35047679

RESUMEN

BACKGROUND: Commonly used strategies for cell delivery to the heart are intramyocardial injection and intracoronary (IC) infusion, both having their advantages and disadvantages. Therefore, alternative strategies, such as retrograde coronary venous infusion (RCVI), are explored. The aim of this confirmatory study was to compare cardiac cell retention between RCVI and IC infusion. As a secondary end point, the procedural safety of RCVI is assessed. METHODS: Four weeks after myocardial infarction, 12 pigs were randomised to receive mesenchymal stromal cells, labelled with Indium-111, via RCVI (n=6) or IC infusion (n=6). Four hours after cell administration, nuclear imaging was performed to determine the number of cells retained in the heart both in vivo and ex vivo. Procedure-related safety measures were reported. RESULTS: Cardiac cell retention is significantly lower after RCVI compared with IC infusion (in vivo: RCVI: median 2.89% vs IC: median 13.74%, p=0.002, ex vivo: RCVI: median 2.55% vs IC: median 39.40%, p=0.002). RCVI led to development of pericardial fluid and haematomas on the frontal wall of the heart in three cases. Coronary venous dissection after RCVI was seen in three pigs, of which one also developed pericardial fluid and a haematoma. IC infusion led to no flow in one pig. CONCLUSION: RCVI is significantly less efficient in delivering cells to the heart compared with IC infusion. RCVI led to more procedure-related safety issues than IC infusion, with multiple cases of venous dissection and development of haematomas and pericardial fluid collections.

14.
Int J Cardiovasc Imaging ; 35(7): 1327-1337, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30847659

RESUMEN

This study was performed to evaluate the feasibility of intra-procedural visualization of optimal pacing sites and image-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT). In fifteen patients (10 males, 68 ± 11 years, 7 with ischemic cardiomyopathy and ejection fraction of 26 ± 5%), optimal pacing sites were identified pre-procedurally using cardiac imaging. Cardiac magnetic resonance (CMR) derived scar and dyssynchrony maps were created for all patients. In six patients the anatomy of the left phrenic nerve (LPN) and coronary sinus ostium was assessed via a computed tomography (CT) scan. By overlaying the CMR and CT dataset onto live fluoroscopy, aforementioned structures were visualized during LV lead implantation. In the first nine patients, the platform was tested, yet, no real-time image-guidance was implemented. In the last six patients real-time image-guided LV lead placement was successfully executed. CRT implant and fluoroscopy times were similar to previous procedures and all leads were placed close to the target area but away from scarred myocardium and the LPN. Patients that received real-time image-guided LV lead implantation were paced closer to the target area compared to patients that did not receive real-time image-guidance (8 mm [IQR 0-22] vs 26 mm [IQR 17-46], p = 0.04), and displayed marked LV reverse remodeling at 6 months follow up with a mean LVESV change of -30 ± 10% and a mean LVEF improvement of 15 ± 5%. Real-time image-guided LV lead implantation is feasible and may prove useful for achieving the optimal LV lead position.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Cardiomiopatías/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Imagen por Resonancia Magnética Intervencional/métodos , Tomografía Computarizada Multidetector , Imagen Multimodal/métodos , Radiografía Intervencional/métodos , Anciano , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Diseño de Equipo , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
15.
ESC Heart Fail ; 6(1): 182-193, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30299600

RESUMEN

AIMS: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value. METHODS AND RESULTS: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non-randomized control group). The primary endpoint is all-cause mortality; the co-primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost-effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12-lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years. CONCLUSIONS: The EU-CERT-ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers.


Asunto(s)
Cardiomiopatía Dilatada/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Prevención Primaria/métodos , Medición de Riesgo , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/mortalidad , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Europa (Continente)/epidemiología , Estudios de Seguimiento , Humanos , Selección de Paciente , Estudios Prospectivos , Calidad de Vida , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
16.
Int J Cardiol ; 272: 102-107, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29983251

RESUMEN

BACKGROUND AND OBJECTIVE: We prospectively investigated combinations of risk stratifiers including multiple EP diagnostics in a cohort study of ICD patients. METHODS: For 672 enrolled patients, we collected history, LVEF, EP study and T-wave alternans testing, 24-h Holter, NT-proBNP, and the eGFR. All-cause mortality and first appropriate ICD shock were predefined endpoints. RESULTS: The 635 patients included in the final analyses were 63 ±â€¯13 years old, 81% were male, LVEF averaged 40 ±â€¯14%, 20% were inducible at EP study, 63% had a primary prophylactic ICD. During follow-up over 4.3 ±â€¯1.5 years, 108 patients died (4.0% per year), and appropriate shock therapy occurred in n = 96 (3.9% per year). In multivariate regression, age (p < 0.001), LVEF (p < 0.001), NYHA functional class (p = 0.007), eGFR (p = 0.024), a history of atrial fibrillation (p = 0.011), and NT-pro-BNP (p = 0.002) were predictors of mortality. LVEF (p = 0.002), inducibility at EP study (p = 0.007), and secondary prophylaxis (p = 0.002) were identified as independent predictors of appropriate shocks. A high annualized risk of shocks of about 10% per year was prevalent in the upper quintile of the shock score. In contrast, a low annual risk of shocks (1.8% per year) was found in the lower two quintiles of the shock score. The lower two quintiles of the mortality score featured an annual mortality <0.6%. CONCLUSIONS: In a prospective ICD patient cohort, a very good approximation of mortality versus arrhythmic risk was possible using a multivariable diagnostic strategy. EP stimulation is the best test to assess risk of arrhythmias resulting in ICD shocks.


Asunto(s)
Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables/tendencias , Desfibriladores/tendencias , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/sangre , Estudios de Cohortes , Muerte Súbita Cardíaca/prevención & control , Desfibriladores/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Análisis Multivariante , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Estudios Prospectivos , Factores de Riesgo
17.
Data Brief ; 21: 2110-2116, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30533459

RESUMEN

This data article features supplementary figures and tables related to the article "Differential Multivariable risk prediction of appropriate shock vs. competing mortality - a prospective cohort study to estimate benefits from implantable cardioverter defibrillator therapy" (Bergau et al., 2018) [1]. The figures show the clinical study CONSORT graph (data that show the number of patients not-analyzable as well as a distribution of patients by outcomes) and the correlation scatter plot for risk scores of appropriate shock vs. mortality (data that show the calculated score values of the two scores plotted against each other). The tables show the results for the univariate Cox regressions for prediction of mortality and appropriate shock. For further information, please see Bergau et al. (2018) [1].

18.
PLoS One ; 12(8): e0183199, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28827816

RESUMEN

OBJECTIVE: Short-term variability of the QT-interval (STV-QT) was shown to be associated with an increased risk of ventricular arrhythmias. We aimed at investigating (a) whether STV-QT exhibits circadian pattern, and (b) whether such pattern differs between patients with high and low arrhythmia risk. METHODS: As part of the ongoing EU-CERT-ICD study, 24h high resolution digital ambulatory 12-lead Holter recordings are collected prior to ICD implantation for primary prophylactic indication. Presently available patients were categorized based on their arrhythmia score (AS), a custom-made weighted score of the number of arrhythmic events on the recording. STV-QT was calculated every hour in 30 patients of which 15 and 15 patients had a high and a low AS, respectively. RESULTS: The overall dynamicity of STV-QT showed high intra- and inter-individual variability with different circadian patterns associated with low and high AS. High AS patients showed a prominent peak both at 08:00 and 18:00. At these times, STV-QT was significantly higher in the high AS patients compared to the low AS patients (1.22ms±0.55ms vs 0.60ms±0.24ms at 08:00 and 1.12ms±0.39ms vs 0.64ms±0.29ms at 18:00, both p < 0.01). CONCLUSION: In patients with high AS, STV-QT peaks in the early morning and late afternoon. This potentially reflects increased arrhythmia risk at these times. Prospective STV-QT determination at these times might thus be more sensitive to identify patients at high risk of ventricular arrhythmias.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Ritmo Circadiano , Electroencefalografía/métodos , Anciano , Electroencefalografía/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Prevención Primaria
19.
Int J Cardiol ; 244: 229-234, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-28663046

RESUMEN

BACKGROUND: The NECTAR-HF study evaluated safety and feasibility of vagal nerve stimulation (VNS) for the treatment of heart failure patients. The first six-month randomized phase of the study did not show improvement in left ventricular remodelling in response to VNS. This study reports the 18-month results and provides novel findings aiming to understand the lack of efficacy of VNS, including a new technique assessing the effects of VNS. METHODS: Ninety-six patients were randomized 2:1 to active or inactive VNS for 6months, thereafter VNS was activated for all patients. The primary safety endpoint was 18-month all-cause mortality. RESULTS: Ninety-one patients continued in the long-term evaluation with active VNS. The on-therapy survival estimate at 18months was 95% with a 95% one-sided lower confidence limit of 91%, (better than the predefined criterion). Left ventricular systolic volume decreased in the crossover group (VNS OFF→ON; 144±37 to 139±40, p<0.05) after VNS activation; LVESD (5.02±0.77 to 4.96±0.82, p>0.05) and LVEF (33.2±4.9 to 33.3±6.5, p>0.05) did not change. A new technique to detect subtle heart rate changes during Holter recordings, i.e. "heat maps", revealed that VNS evoked heart rate response in only 13/106 studies (12%) at 6 and 12months with active VNS. CONCLUSIONS: Although a favourable long-term safety profile was found, improvements in the efficacy endpoints were not seen with VNS. A new technique for detecting acute heart rate responses to VNS suggests that the recruitment of nerve fibres responsible for heart rate changes were substantially lower in NECTAR-HF than in pre-clinical models.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Estimulación del Nervio Vago/tendencias , Anciano , Electrocardiografía Ambulatoria/mortalidad , Electrocardiografía Ambulatoria/tendencias , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Estimulación del Nervio Vago/mortalidad
20.
Int J Cardiol ; 95(1): 101-8, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15159046

RESUMEN

BACKGROUND: Maze surgery is a final solution for intractable atrial fibrillation (AF), but an adverse effect on postoperative sinus node function has been reported. Whether this also applies to other types of cardiac surgery is unclear. METHODS: We assessed postoperative rhythm by means of repeated exercise tolerance testing, ambulatory electrocardiography, and non-invasive testing of autonomic function between 1 and 12 months after four types of cardiac surgery. Fourteen patients without structural cardiac disease and medically refractory AF underwent the maze III procedure, 11 patients with mitral valve disease and preoperative AF underwent valvar surgery combined with a (simplified) maze III procedure, and 8 patients with mitral valve disease in sinus rhythm (SR) underwent isolated valvar surgery. The control group consisted of eight patients with sinus rhythm who underwent coronary artery bypass surgery (CABG). RESULTS: One month after surgery, the chronotropic response to exercise was depressed, mean heart rate was high, and heart rate variability (HRV) was low, especially after maze III, combined surgery, and isolated valvar surgery. Twelve months after surgery, moderate improvements were observed. After CABG, considerably fewer abnormalities were observed, and HRV parameters recovered to a large extent. Non-invasive testing of autonomic function indicated disturbed vagal modulation of heart rate in all three groups with atrial incision. CONCLUSION: Thus, attenuation of HRV and vagal modulation of sinus node function are not confined to maze surgery but also apply to isolated mitral valve surgery. Atrial incision therefore appears to be crucial and presumably produces autonomic nervous damage followed by partial reinnervation. Nevertheless, cardiac surgery in general seems initially to impair sinus node function with partial recovery in the consecutive 12 months.


Asunto(s)
Función Atrial/fisiología , Procedimientos Quirúrgicos Cardíacos , Nodo Sinoatrial/fisiología , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Puente Cardiopulmonar , Electrocardiografía Ambulatoria , Prueba de Esfuerzo , Tolerancia al Ejercicio/fisiología , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA