RESUMEN
BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estudios Prospectivos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Accidente Cerebrovascular/etiologíaRESUMEN
BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.
Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Factores de RiesgoRESUMEN
BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.
Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Incidencia , Factores de Riesgo , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , EcocardiografíaRESUMEN
Use of transcatheter mitral valve replacement (TMVR) using transcatheter aortic valves in clinical practice is limited to patients with failing bioprostheses and rings or mitral valve disease associated with severe mitral annulus calcification. Whereas the use of valve-in-valve TMVR appears to be a reasonable alternative to surgery in patients at high surgical risk, much less evidence supports valve-in-ring and valve-in-mitral annulus calcification interventions. Data on the results of TMVR in these settings are derived from small case series or voluntary registries. This review summarizes the current evidence on TMVR using transcatheter aortic valves in clinical practice from the characteristics of the TMVR candidates, screening process, performance of the procedure, and description of current results and future perspectives. TMVR using dedicated devices in native noncalcified mitral valve diseases is beyond the scope of the article.
Asunto(s)
Válvula Aórtica/cirugía , Calcinosis/cirugía , Implantación de Prótesis de Válvulas Cardíacas/normas , Prótesis Valvulares Cardíacas/normas , Válvula Mitral/cirugía , Diseño de Prótesis/normas , Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Cateterismo Cardíaco/tendencias , Prótesis Valvulares Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Válvula Mitral/diagnóstico por imagen , Anuloplastia de la Válvula Mitral/métodos , Anuloplastia de la Válvula Mitral/normas , Anuloplastia de la Válvula Mitral/tendencias , Diseño de Prótesis/métodos , Diseño de Prótesis/tendenciasRESUMEN
BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; Pâ =â .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; Pâ <â .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, Pâ <â .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padjâ <â 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.
Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversosRESUMEN
BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; Pâ =â .12), but the rate of early IE was lower in the CC (2.29 vs 4.89, Pâ <â .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; Pâ =â .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; Pâ =â .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; Pâ =â .036) and in-hospital (26.6% vs 36.4%; Pâ =â .016) and 1-year (37.8% vs 53.5%; Pâ <â .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (Pâ <â .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.
Asunto(s)
Endocarditis Bacteriana , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Incidencia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
OBJECTIVES: To evaluate the causes and predictors of mortality after valve-in-mitral annulus calcification (MAC) transcatheter mitral valve implantation (TMVI). BACKGROUND: Conventional surgical mitral valve replacement is associated with a high risk in patients with mitral valve disease associated with severe MAC. In this population, TMVI may be an attractive alternative option. However, its prognostic factors are poorly understood. METHODS: All patients undergoing valve-in-MAC TMVI from 2013 to 2018 in our center were included. Indication for TMVI relied on the judgment of the local heart team. Patients were followed at 30 days and 1 year. RESULTS: A total of 34 patients underwent valve-in-MAC TMVI. The mean age was 79 ± 11 years and 73% of patients were women. Their mean EuroSCORE 2 was 8 ± 7%. The transseptal approach was used in 79% of patients and a hybrid transatrial in 29%. Balloon expandable transcatheter heart valves were used in all the patients. Technical success was achieved in 76% of the patients. Thirty-day and 1-year all-cause mortality rates were 14.7% and 32.4%, respectively. The main two causes of 1-year mortality were congestive heart failure (8.8%) and infective endocarditis (5.9%). In multivariate analysis, the only predictor of 1-year mortality was the presence of periprothetic mitral regurgitation grade 2 (HR, 5.69; 95%CI, 1.59-27.88, p = 0.032). CONCLUSION: Early and mid-term mortality remains high after valve-in-MAC TMVI and seems to be associated with the presence of paravalvular mitral regurgitation. However, whether the latter is a prognostic factor or marker remains to be determined to improve clinical outcomes in this high-risk population.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del TratamientoRESUMEN
AIMS: We determined the incidence and type of arrhythmias at 2-year follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: Multicentre prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR (SAPIEN XT/3: 53; CoreValve/Evolut R: 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted before hospital discharge and patients had continuous monitoring for up to 2 years. Arrhythmic events were adjudicated in a central core lab. 1836 new arrhythmic events (tachyarrhythmias: 1655 and bradyarrhythmias: 181) occurred at 2 years. Of these, 283 (15%) occurred beyond 1 year (tachyarrhythmias 212, bradyarrhythmias 71) in 33 (36%) patients, without differences between valve type. Most late (>1 year) arrhythmic events were asymptomatic (94%) and led to a treatment change in 17 (19%) patients. A total of 71 late bradyarrhythmias [high-degree atrioventricular block (HAVB): 3, severe bradycardia: 68] were detected in 17 (21%) patients. At 2 years, 18 (17%) patients had received a permanent pacemaker (PPM) or implantable cardiac-defibrillator. PPM implantation due to HAVB predominated in the early phase post-TAVR, with only 1 HAVB event requiring PPM implantation after 1 year. CONCLUSION: Patients with new-onset LBBB post-TAVR exhibited a very high burden of arrhythmic events within the 2 years post-procedure. While new tachyarrhythmic events were homogeneously distributed over time, the vast majority of new HAVB episodes leading to PPM implantation occurred early after the procedure. These results should help to guide the management of this challenging group of patients. (clinicaltrials.gov: NCT02153307).
Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Humanos , Estudios Prospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.
Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Resultado del TratamientoRESUMEN
Transcatheter tricuspid valve-in-valve replacement (TTVR) represents an attractive therapeutic option in very high surgical risk patients with degenerated tricuspid bioprostheses. However, the procedural management of these patients might be challenging due to their comorbidities, long lasting heart valve disease and the presence of left-sided mechanical prostheses. Thus, a more "minimally disruptive" procedure would have several potential benefits in such a frail population. We present the cases of four patients admitted for congestive heart failure due to severe degeneration of their tricuspid bioprostheses who were treated with a minimalist TTVR. The protocol combined continuation of the oral anticoagulant treatment with no bridging therapy, the use of a single venous access with local anesthesia, rapid pacing via the stiff right ventricular wire, and transthoracic echocardiographic guidance and assessment, with no need for contrast injection. Our protocol aims at simplifying the TTVR procedure and might be a useful tool to avoid procedural complications and reduce hospital stay.
Asunto(s)
Bioprótesis , Cateterismo Cardíaco/instrumentación , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Cardiopatía Reumática/cirugía , Válvula Tricúspide/cirugía , Administración Oral , Adulto , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Cateterismo Cardíaco/efectos adversos , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Recuperación de la Función , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/fisiopatología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatologíaRESUMEN
Aims: We analysed the early and long-term clinical and haemodynamic outcomes of balloon-expandable transcatheter mitral valve implantation (TMVI) in an experienced centre. Methods and results: All patients undergoing TMVI from July 2010 to July 2017 in our centre were prospectively included. Indication for TMVI relied on the judgement of the local heart team. Patients were followed at 1 month, 1 year, and yearly thereafter. A total of 91 patients underwent TMVI. The median age was 73 (57-81) years and 70% of patients were women. Patients were at high risk for surgery with a median EuroSCORE II of 9.6 (4.0-14.6) %. Indication for TMVI was bioprosthesis failure (valve-in-valve) in 37.3%, annuloplasty failure (valve-in-ring) in 33.0%, and severe mitral annulus calcification (MAC) in 29.7%. The transseptal approach was used in 92.3% of patients and balloon-expandable valves were used in all patients. Technical success was achieved in 84.6% of patients, one patient died during the procedure and haemodynamically significant left ventricular outflow tract obstruction occurred in three patients (3.3%). At 30 days, 7.7% of patients had died, without significant differences between groups, and a major stroke occurred in 2.2% of patients. The cumulative rates of all-cause mortality at 1-year and 2-year follow-up were 21.0% [95% confidence interval (CI) 9.9-38.8] and 35.7% (95% CI 19.2-56.5), respectively, with a higher late mortality in patients with MAC. The 2-year rates of re-intervention and valve thrombosis were 8.8% and 14.4%, respectively. At 6 months to 1 year, 68.9% of patients were in New York Heart Association Class I or II, and 90.7% of patients had mild or less mitral regurgitation. The mean transmitral gradient decreased from 9.3 ± 3.9 mmHg at baseline to 6.0 ± 2.3 mmHg at discharge (P < 0.001) without changes at 6-month to 1-year follow-up. Conclusion: Transcatheter mitral valve implantation using balloon-expandable valves in selected patients with bioprosthesis or annuloplasty failure or severe MAC was associated with a low rate of peri-procedural complications and acceptable long-term outcomes.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
Transcatheter aortic valve replacement (TAVR) has become a well-accepted option for treating patients with aortic stenosis at intermediate to high or prohibitive surgical risk. TAVR-related conduction disturbances, mainly new-onset left bundle-branch block and advanced atrioventricular block requiring permanent pacemaker implantation, remain the most common complication of this procedure. Furthermore, improvements in TAVR technology, akin to the increasing experience of operators/centers, have translated to a major reduction in periprocedural complications, yet the incidence of conduction disturbances has remained relatively high, with perhaps an increasing trend over time. Several factors have been associated with a heightened risk of conduction disturbances and permanent pacemaker implantation after TAVR, with prior right bundle-branch block and transcatheter valve type and implantation depth being the most commonly reported. New-onset left bundle-branch block and the need for permanent pacemaker implantation may have a significant detrimental association with patients' prognosis. Consequently, strategies intended to reduce the risk and to improve the management of such complications are of paramount importance, particularly in an era when TAVR expansion toward treating lower-risk patients is considered inevitable. In this article, we review the available evidence on the incidence, predictive factors, and clinical association of conduction disturbances after TAVR and propose a strategy for the management of these complications.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/mortalidad , Arritmias Cardíacas/mortalidad , Bloqueo de Rama/mortalidad , Predicción , Humanos , Mortalidad/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Resultado del TratamientoRESUMEN
OBJECTIVES: This study aimed to assess the impact of pacemaker mode programming on clinical outcomes in patients with high-degree atrioventricular conduction disturbance (AVCD) after transcatheter aortic valve implantation (TAVI). BACKGROUND: Although high-degree AVCD after TAVI can receive pacemaker, recovery of the AVCD is often observed. Specific pacemaker algorithms (AAI-DDD mode switch) are available which favor spontaneous atrioventricular conduction. METHODS: Of 1,621 consecutive multi-center TAVI patients, 269 (16.4%) received pacemaker. We retrospectively included 91 patients with persistent high-degree AVCD at hospital discharge. Pacemaker dependency was defined as absence, inadequate intrinsic ventricular rhythm, or ventricular pacing time > 95% on pacemaker interrogation during follow-up. Comparison of heart failure hospitalization and death between conventional DDD (cDDD) and other modes was examined (AAI-DDD and VVI). RESULTS: During a mean follow-up duration of 13 months, the pacemaker dependency rate was 52.8%. Patients with cDDD mode (N = 36: 40.0%) had significantly more pacemaker dependency. Multivariate analysis showed that cDDD mode was independently associated with pacemaker dependency (odds ratio = 3.63, P = 0.03). Moreover, cDDD patients had a significant higher incidence of heart failure hospitalization (Hospitalization: cDDD vs. others = 45.4% vs. 18.2%, P = 0.03) and had a higher incidence of mortality (Death: cDDD vs. the others = 27.0% vs. 4.4%, P = 0.06). CONCLUSIONS: Up to half of patients implanted for high-degree AVCD after TAVI had conduction recovery. Patients with cDDD programming at hospital discharge had more pacemaker dependency and a worse cardiac prognosis. Thus, pacemaker mode should be systematically set to promote spontaneous atrioventricular conduction in patients with pacemaker implantation after TAVI.
Asunto(s)
Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Algoritmos , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/mortalidad , Bloqueo Atrioventricular/fisiopatología , Diseño de Equipo , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca , Hospitalización , Humanos , Masculino , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
Atrial fibrillation (AF) is a common arrhythmia in patients with aortic stenosis. When these patients are treated medically or by surgical aortic valve replacement, AF is associated with increased risk of adverse events including death. Growing evidence suggests a significant impact of AF on outcomes also in patients with aortic valve stenosis undergoing transcatheter aortic valve implantation (TAVI). Conversely, limited evidence is available regarding the optimal management of this condition. This review aims to summarize prevalence, pathophysiology, prognosis, and treatment of AF in patients undergoing TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fibrilación Atrial/etiología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Anticoagulantes/uso terapéutico , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Fibrilación Atrial/mortalidad , Fibrilación Atrial/terapia , Pérdida de Sangre Quirúrgica/estadística & datos numéricos , Femenino , Fibrinolíticos/uso terapéutico , Predicción , Humanos , Masculino , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Accidente Cerebrovascular/etiología , Resultado del TratamientoRESUMEN
OBJECTIVES: To evaluate the outcomes of the early experience of percutaneous alcohol septal ablation in patients with severe left ventricular outflow tract (LVOT) obstruction post transcatheter mitral valve replacement (TMVR). BACKGROUND: Severe LVOT obstruction with hemodynamic compromise is a complication of TMVR associated with high mortality. Percutaneous alcohol septal ablation has recently been described as a therapeutic option in this setting. METHODS: Multicenter retrospective review of clinical outcomes of patients undergoing alcohol septal ablation to treat LVOT obstruction after TMVR for severe mitral stenosis with severe mitral annular calcification. RESULTS: Six patients underwent percutaneous alcohol septal ablation to treat LVOT obstruction post-TMVR at six different centers. Five patients had immediate significant reduction in LVOT obstruction with improvement in hemodynamic status while one had persistent LVOT gradient but hemodynamic instability improved. The first patient died on postoperative day 4 due to complete heart block. One patient had initial improvement in LVOT gradient with recurrence on postoperative day 1 thought to be secondary to septal edema, was treated with surgical removal of the transcatheter valve and resection of the anterior mitral leaflet followed by transatrial TMVR and died 3 weeks later due to multi-organ failure. The remaining four patients improved clinically after alcohol septal ablation, were discharged from the hospital and were clinically stable at 30-day follow-up. CONCLUSIONS: Percutaneous alcohol ablation provides acute relief of TMVR-induced LVOT obstruction when septal hypertrophy is a contributing factor. This may be a safer alternative to bail-out surgery in this extremely high-risk patient population. © 2017 Wiley Periodicals, Inc.
Asunto(s)
Técnicas de Ablación , Calcinosis/cirugía , Cateterismo Cardíaco/efectos adversos , Etanol/administración & dosificación , Tabiques Cardíacos/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Cateterismo Cardíaco/métodos , Etanol/efectos adversos , Femenino , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/fisiopatología , Sistema de Registros , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatologíaRESUMEN
BACKGROUND: This study sought to evaluate the prevalence of previously undiagnosed arrhythmias in candidates for transcatheter aortic valve replacement (TAVR) and to determine the impact on therapy changes and arrhythmic events after the procedure. METHODS AND RESULTS: A total of 435 candidates for TAVR underwent 24-hour continuous ECG monitoring the day before the procedure. Newly diagnosed arrhythmias were observed in 70 patients (16.1%) before TAVR: paroxysmal atrial fibrillation (AF)/atrial tachycardia (AT) in 28, advanced atrioventricular block or severe bradycardia in 24, nonsustained ventricular tachycardia in 26, and intermittent left bundle-branch block in 3 patients. All arrhythmic events but one were asymptomatic and led to a therapy change in 43% of patients. In patients without known AF/AT, the occurrence of AF/AT during 24-hour ECG recording was associated with a higher rate of 30-day cerebrovascular events (7.1% versus 0.4%; P=0.030). Among the 53 patients with new-onset AF/AT after TAVR, 30.2% had newly diagnosed paroxysmal AF/AT before the procedure. In patients who needed permanent pacemaker implantation after the procedure (n=35), 31.4% had newly diagnosed advanced atrioventricular block or severe bradycardia before TAVR. New-onset persistent left bundle-branch block after TAVR occurred in 37 patients, 8.1% of whom had intermittent left bundle-branch block before the procedure. CONCLUSIONS: Newly diagnosed arrhythmias were observed in approximately a fifth of TAVR candidates, led to a higher rate of cerebrovascular events, and accounted for a third of arrhythmic events after the procedure. This high arrhythmia burden highlights the importance of an early diagnosis of arrhythmic events in such patients to implement the appropriate therapeutic measures earlier.
Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Arritmias Cardíacas/diagnóstico , Costo de Enfermedad , Electrocardiografía Ambulatoria/tendencias , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/fisiopatología , Comprensión , Femenino , Humanos , Masculino , Cuidados Preoperatorios/tendencias , Resultado del TratamientoRESUMEN
BACKGROUND: We aimed to determine the incidence, predictors, clinical characteristics, management, and outcomes of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: This multicenter registry included 53 patients (mean age, 79±8 years; men, 57%) who suffered IE after TAVI of 7944 patients after a mean follow-up of 1.1±1.2 years (incidence, 0.67%, 0.50% within the first year after TAVI). Mean time from TAVI was 6 months (interquartile range, 1-14 months). Orotracheal intubation (hazard ratio, 3.87; 95% confidence interval, 1.55-9.64; P=0.004) and the self-expandable CoreValve system (hazard ratio, 3.12; 95% confidence interval, 1.37-7.14; P=0.007) were associated with IE (multivariate analysis including 3067 patients with individual data). The most frequent causal microorganisms were coagulase-negative staphylococci (24%), followed by Staphylococcus aureus (21%) and enterococci (21%). Vegetations were present in 77% of patients (transcatheter valve leaflets, 39%; stent frame, 17%; mitral valve, 21%). At least 1 complication of IE occurred in 87% of patients (heart failure in 68%). However, only 11% of patients underwent valve intervention (valve explantation and valve-in-valve procedure in 4 and 2 patients, respectively). The mortality rate in hospital was 47.2% and increased to 66% at the 1-year follow-up. IE complications such as heart failure (P=0.037) and septic shock (P=0.002) were associated with increased in-hospital mortality. CONCLUSIONS: The incidence of IE at 1 year after TAVI was 0.50%, and the risk increased with the use of orotracheal intubation and a self-expandable valve system. Staphylococci and enterococci were the most common agents. Although most patients presented at least 1 complication of IE, valve intervention was performed in a minority of patients, and nearly half of the patients died during the hospitalization period.
Asunto(s)
Endocarditis Bacteriana/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Infecciones Relacionadas con Prótesis/etiología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Endocarditis Bacteriana/mortalidad , Endocarditis Bacteriana/cirugía , Enterococcus , Contaminación de Equipos , Femenino , Infecciones por Bacterias Grampositivas/etiología , Infecciones por Bacterias Grampositivas/cirugía , Insuficiencia Cardíaca/etiología , Mortalidad Hospitalaria , Humanos , Incidencia , Intubación Intratraqueal/efectos adversos , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Modelos de Riesgos Proporcionales , Infecciones Relacionadas con Prótesis/mortalidad , Infecciones Relacionadas con Prótesis/cirugía , Sistema de Registros , Estudios Retrospectivos , Riesgo , Infecciones Estafilocócicas/etiología , Infecciones Estafilocócicas/cirugía , Resultado del TratamientoAsunto(s)
Endocarditis Bacteriana , Mortalidad Hospitalaria , Complicaciones Posoperatorias/mortalidad , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana EdadRESUMEN
IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20â¯006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.